Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 409
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Chem Soc Rev ; 53(8): 3656-3686, 2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38502089

RESUMO

Advancements in nanochemistry have led to the development of engineered gold nanostructures (GNSs) with remarkable potential for a variety of dental healthcare applications. These innovative nanomaterials offer unique properties and functionalities that can significantly improve dental diagnostics, treatment, and overall oral healthcare applications. This review provides an overview of the latest advancements in the design, synthesis, and application of GNSs for dental healthcare applications. Engineered GNSs have emerged as versatile tools, demonstrating immense potential across different aspects of dentistry, including enhanced imaging and diagnosis, prevention, bioactive coatings, and targeted treatment of oral diseases. Key highlights encompass the precise control over GNSs' size, crystal structure, shape, and surface functionalization, enabling their integration into sensing, imaging diagnostics, drug delivery systems, and regenerative therapies. GNSs, with their exceptional biocompatibility and antimicrobial properties, have demonstrated efficacy in combating dental caries, periodontitis, peri-implantitis, and oral mucosal diseases. Additionally, they show great promise in the development of advanced sensing techniques for early diagnosis, such as nanobiosensor technology, while their role in targeted drug delivery, photothermal therapy, and immunomodulatory approaches has opened new avenues for oral cancer therapy. Challenges including long-term toxicity, biosafety, immune recognition, and personalized treatment are under rigorous investigation. As research at the intersection of nanotechnology and dentistry continues to thrive, this review highlights the transformative potential of engineered GNSs in revolutionizing dental healthcare, offering accurate, personalized, and minimally invasive solutions to address the oral health challenges of the modern era.


Assuntos
Ouro , Ouro/química , Humanos , Propriedades de Superfície , Nanopartículas Metálicas/química , Odontologia , Sistemas de Liberação de Medicamentos , Nanotecnologia/métodos
2.
Neuroimage ; 300: 120857, 2024 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-39299660

RESUMO

BACKGROUND: White matter (WM) fiber tracts in the brainstem communicate with various regions in the cerebrum, cerebellum, and spinal cord. Clinically, small lesions, malformations, or histopathological changes in the brainstem can cause severe neurological disorders. A direct and non-invasive assessment approach could bring valuable information about the intricate anatomical variations of the white matter fiber tracts and nuclei. Although tractography from diffusion tensor imaging has been commonly used to map the WM fiber tracts connectivity, it is difficult to differentiate the complex WM tracts anatomically. Both high field MRI methods and ultrahigh-field MRI methods at 7T and 11.7 T have been used to enhance the contrast of WM fiber tracts. Despite their promising results, it is still challenging to achieve wide clinical adoption at 3T. In this study, we explored a clinically feasible method using a proton density weighted (PDW) 3D gradient echo (GRE) sequence to directly image the WM fiber tracts in the brainstem at 3T in vivo. METHODS: We optimized a 3D high resolution, double echo, short TR, PDW GRE sequence on 5 healthy volunteers using a clinical 3T scanner to visualize the complicated anatomy of WM fiber tracts in the brain stem. Tissue properties including T1, proton density and T2* from in vivo quantitative MRI data were used for simulations to determine the optimal flip angle for the sequence. The visualization of multiple WM fiber tracts in the brainstem was assessed qualitatively and quantitatively using relative contrast and contrast-to-noise ratio (CNR). To improve the CNR, the final images were created by averaging over all echoes from two consecutive scans at the optimal flip angle. The results were compared to anatomical atlases and histology sections to identify the major fiber tracts. All the identified major fiber tracts were labeled on axial, sagittal and coronal slices. RESULTS: The WM fiber tracts were found to have distinct hypointense signal throughout the brainstem and most of the major WM fiber tracts, such as the corticospinal tract, medial lemniscus, medial longitudinal fasciculus, and central tegmental tract, in the brainstem up to and including the thalamus were identified in all subjects. Both qualitative and quantitative evaluations showed that the 3° scan offered the best contrast for WM fiber tracts for a TR of 20 ms. The average over the first two echo times and two consecutive 3° scans gave a CNR of 47.8 ± 6.2 for the pyramidal tracts in particular and CNRs values greater than 6.5 ± 2.4 for the rest of the fiber tracts. CONCLUSIONS: All the major fiber tracts in the brainstem could be visualized. Given the reasonably short scan time of 10 min at 3T, double echo PDW GRE sequence is a very practical approach for clinical adoption.


Assuntos
Tronco Encefálico , Imagem de Tensor de Difusão , Substância Branca , Humanos , Tronco Encefálico/diagnóstico por imagem , Tronco Encefálico/anatomia & histologia , Substância Branca/diagnóstico por imagem , Substância Branca/anatomia & histologia , Adulto , Masculino , Feminino , Imagem de Tensor de Difusão/métodos , Imageamento Tridimensional/métodos , Adulto Jovem , Imageamento por Ressonância Magnética/métodos
3.
Neuroimage ; 291: 120588, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38537765

RESUMO

BACKGROUND: Parkinson's disease (PD) is associated with the loss of neuromelanin (NM) and increased iron in the substantia nigra (SN). Magnetization transfer contrast (MTC) is widely used for NM visualization but has limitations in brain coverage and scan time. This study aimed to develop a new approach called Proton-density Enhanced Neuromelanin Contrast in Low flip angle gradient echo (PENCIL) imaging to visualize NM in the SN. METHODS: This study included 30 PD subjects and 50 healthy controls (HCs) scanned at 3T. PENCIL and MTC images were acquired. NM volume in the SN pars compacta (SNpc), normalized image contrast (Cnorm), and contrast-to-noise ratio (CNR) were calculated. The change of NM volume in the SNpc with age was analyzed using the HC data. A group analysis compared differences between PD subjects and HCs. Receiver operating characteristic (ROC) analysis and area under the curve (AUC) calculations were used to evaluate the diagnostic performance of NM volume and CNR in the SNpc. RESULTS: PENCIL provided similar visualization and structural information of NM compared to MTC. In HCs, PENCIL showed higher NM volume in the SNpc than MTC, but this difference was not observed in PD subjects. PENCIL had higher CNR, while MTC had higher Cnorm. Both methods revealed a similar pattern of NM volume in SNpc changes with age. There were no significant differences in AUCs between NM volume in SNpc measured by PENCIL and MTC. Both methods exhibited comparable diagnostic performance in this regard. CONCLUSIONS: PENCIL imaging provided improved CNR compared to MTC and showed similar diagnostic performance for differentiating PD subjects from HCs. The major advantage is PENCIL has rapid whole-brain coverage and, when using STAGE imaging, offers a one-stop quantitative assessment of tissue properties.


Assuntos
Doença de Parkinson , Humanos , Doença de Parkinson/diagnóstico por imagem , Substância Negra/diagnóstico por imagem , Parte Compacta da Substância Negra , Imageamento por Ressonância Magnética/métodos , Melaninas
4.
Radiology ; 312(3): e240038, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39315897

RESUMO

Background Traditional energy-integrating detector CT has limited utility in accurately quantifying liver fat due to protocol-induced CT value shifts, but this limitation can be addressed by using photon-counting detector (PCD) CT, which allows for a standardized CT value. Purpose To develop and validate a universal CT to MRI fat conversion formula to enhance fat quantification accuracy across various PCD CT protocols relative to MRI proton density fat fraction (PDFF). Materials and Methods In this prospective study, the feasibility of fat quantification was evaluated in phantoms with various nominal fat fractions. Five hundred asymptomatic participants and 157 participants with suspected metabolic dysfunction-associated steatotic liver disease (MASLD) were enrolled between September 2023 and March 2024. Participants were randomly assigned to six groups with different CT protocols regarding tube voltage (90, 120, or 140 kVp) and radiation dose (standard or low). Of the participants in the 120-kVp standard-dose asymptomatic group, 51% (53 of 104) were designated as the training cohort, with the rest of the asymptomatic group serving as the validation cohort. A CT to MRI fat quantification formula was derived from the training cohort to estimate the CT-derived fat fraction (CTFF). CTFF agreement with PDFF and its error were evaluated in the asymptomatic validation cohort and subcohorts stratified by tube voltage, radiation dose, and body mass index, and in the MASLD cohort. The factors influencing CTFF error were further evaluated. Results In the phantoms, CTFF showed excellent agreement with nominal fat fraction (intraclass correlation coefficient, 0.98; mean bias, 0.2%). A total of 412 asymptomatic participants and 122 participants with MASLD were included. A CT to MRI fat conversion formula was derived as follows: MRI PDFF (%) = -0.58 · CT (HU) + 43.1. Across all comparisons, CTFF demonstrated excellent agreement with PDFF (mean bias values < 1%). CTFF error was not influenced by tube voltage, radiation dose, body mass index, or PDFF. Agreement between CTFF and PDFF was also found in the MASLD cohort (mean bias, -0.2%). Conclusion Standardized CT value from PCD CT showed a robust and remarkable agreement with MRI PDFF across various protocols and may serve as a precise alternative for liver fat quantification. © RSNA, 2024 Supplemental material is available for this article. See also the editorial by Wildman-Tobriner in this issue.


Assuntos
Estudos de Viabilidade , Imageamento por Ressonância Magnética , Imagens de Fantasmas , Tomografia Computadorizada por Raios X , Humanos , Masculino , Feminino , Estudos Prospectivos , Tomografia Computadorizada por Raios X/métodos , Pessoa de Meia-Idade , Imageamento por Ressonância Magnética/métodos , Fígado/diagnóstico por imagem , Adulto , Fígado Gorduroso/diagnóstico por imagem , Idoso , Fótons
5.
Magn Reson Med ; 2024 Oct 20.
Artigo em Inglês | MEDLINE | ID: mdl-39428691

RESUMO

PURPOSES: To enhance the functional capability of MRI, this study aims to develop a novel MR elastography (MRE) sequence that achieves rapid acquisition without distortion artifacts. METHODS: A displacement-encoded stimulated echo (DENSE) with multiphase acquisition scheme was used to capture wave images. A center-out golden-angle stack-of-stars sampling pattern was introduced for improved SNR and data incoherence. A combination of Hadamard encoding and interleaved multislab acquisition schemes was used to increase the acquisition efficiency of MRE data with multiple directions and phase offsets. A generalized parallel-imaging and compressed-sensing method was further applied to accelerate the acquisition process. The imaging results of the proposed sequence were compared with those from six gradient echo (GRE)/EPI/DENSE-based MRE sequences via phantom and brain acquisitions. RESULTS: The proposed sequence achieved a 6-fold acceleration compared with GRE MRE. With the application of a conventional parallel-imaging and compressed-sensing algorithm, the scanning speed was further accelerated by 8-fold, matching the speed of EPI-based MRE. Phantom tests revealed small variances in stiffness measurements across the seven sequences (< 9.23%). The proposed sequence exhibited a higher contrast-to-noise ratio (1.38) than the two EPI-based sequences (0.61/0.76) and similar to GRE-based sequences (1.34/1.22/1.58). Brain imaging validated the effectiveness of the proposed sequence in accurate stiffness estimation and distortion artifact avoidance. CONCLUSION: A rapid DENSE-based MRE sequence with interleaved multislab acquisition and Hadamard encoding was developed at a speed matching EPI-based sequences, without compromising SNR or introducing distortion artifacts.

6.
J Magn Reson Imaging ; 60(5): 2207-2213, 2024 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-38376448

RESUMO

BACKGROUND: Diffusion-weighted imaging (DWI)-based virtual MR elastography (DWI-vMRE) in the assessment of breast lesions is still in the research stage. PURPOSE: To investigate the usefulness of elasticity values on DWI-vMRE in the evaluation of breast lesions, and the correlation with the values calculated from shear-wave elastography (SWE). STUDY TYPE: Prospective. POPULATION/SUBJECTS: 153 patients (mean age ± standard deviation: 55 ± 12 years) with 153 pathological confirmed breast lesions (24 benign and 129 malignant lesions). FIELD STRENGTH/SEQUENCE: 1.5-T MRI, multi-b readout segmented echo planar imaging (b-values of 0, 200, 800, and 1000 sec/mm2). ASSESSMENT: For DWI-vMRE assessment, lesions were manually segmented using apparent diffusion coefficient (ADC0-1000) map, then the region of interests were copied to the map of shifted-ADC (sADC200-800, sADC 200-1500). For SWE assessment, the shear modulus of the lesions was measured by US elastic modulus (µUSE). Intraclass/interclass kappa coefficients were calculated to measure the consistency. STATISTICAL TESTS: Pearson's correlation was used to assess the relationship between sADC and µUSE. A receiver operating characteristic analysis with the area under the curve (AUC) was performed to compare the diagnostic accuracy between benign and malignant breast lesions of sADC and µUSE. A P value <0.05 was considered statistically significant. RESULTS: There were significant differences between benign and malignant breast lesions of µUSE (24.17 ± 10.64 vs. 37.20 ± 12.61), sADC200-800 (1.38 ± 0.31 vs. 0.97 ± 0.18 × 10-3 mm2/sec), and sADC200-1500 (1.14 ± 0.30 vs. 0.78 ± 0.13 × 10-3 mm2/sec). In all breast lesions, a moderate but significant correlation was observed between µUSE and sADC200-800/sADC200-1500 (r = -0.49/-0.44). AUC values to differentiate benign from malignant lesions were as follows: µUSE, 0.78; sADC200-800, 0.89; sADC200-1500, 0.89. DATA CONCLUSIONS: Both SWE and DWI-vMRE could be used for the differentiation of benign versus malignant breast lesions. Furthermore, DWI-vMRE with the use of sADC show relatively higher AUC values than SWE. LEVEL OF EVIDENCE: 4 TECHNICAL EFFICACY: Stage 2.


Assuntos
Neoplasias da Mama , Mama , Imagem de Difusão por Ressonância Magnética , Técnicas de Imagem por Elasticidade , Humanos , Técnicas de Imagem por Elasticidade/métodos , Feminino , Pessoa de Meia-Idade , Neoplasias da Mama/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética/métodos , Estudos Prospectivos , Mama/diagnóstico por imagem , Idoso , Adulto , Reprodutibilidade dos Testes , Imagem Ecoplanar/métodos , Módulo de Elasticidade , Interpretação de Imagem Assistida por Computador/métodos , Curva ROC , Sensibilidade e Especificidade
7.
J Magn Reson Imaging ; 2024 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-38449389

RESUMO

BACKGROUND: Different MR elastography (MRE) systems may produce different stiffness measurements, making direct comparison difficult in multi-center investigations. PURPOSE: To assess the repeatability and reproducibility of liver stiffness measured by three typical MRE systems. STUDY TYPE: Prospective. POPULATION/PHANTOMS: Thirty volunteers without liver disease history (20 males, aged 21-28)/5 gel phantoms. FIELD STRENGTH/SEQUENCE: 3.0 T United Imaging Healthcare (UIH), 1.5 T Siemens Healthcare, 3.0 T General Electric Healthcare (GE)/Echo planar imaging-based MRE sequence. ASSESSMENT: Wave images of volunteers and phantoms were acquired by three MRE systems. Tissue stiffness was evaluated by two observers, while phantom stiffness was assessed automatically by code. The reproducibility across three MRE systems was quantified based on the mean stiffness of each volunteer and phantom. STATISTICAL TESTS: Intraclass correlation coefficients (ICC), coefficients of variation (CV), and Bland-Altman analyses were used to assess the interobserver reproducibility, the interscan repeatability, and the intersystem reproducibility. Paired t-tests were performed to assess the interobserver and interscan variation. Friedman tests with Dunn's multiple comparison correction were performed to assess the intersystem variation. P values less than 0.05 indicated significant difference. RESULTS: The reproducibility of stiffness measured by the two observers demonstrated consistency with ICC > 0.92, CV < 4.32%, Mean bias < 2.23%, and P > 0.06. The repeatability of measurements obtained using the electromagnetic system for the liver revealed ICC > 0.96, CV < 3.86%, Mean bias < 0.19%, P > 0.90. When considering the range of reproducibility across the three systems for liver evaluations, results ranged with ICCs from 0.70 to 0.87, CVs from 6.46% to 10.99%, and Mean biases between 1.89% and 6.30%. Phantom studies showed similar results. The values of measured stiffness differed across all three systems significantly. DATA CONCLUSION: Liver stiffness values measured from different MRE systems can be different, but the measurements across the three MRE systems produced consistent results with excellent reproducibility. EVIDENCE LEVEL: 1 TECHNICAL EFFICACY: Stage 2.

8.
J Magn Reson Imaging ; 59(1): 297-308, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37165908

RESUMO

BACKGROUND: Computed diffusion-weighted images (cDWI) of random b value could be derived from acquired DWI (aDWI) with at least two different b values. However, its comparison between aDWI and cDWI images in locally advanced rectal cancer (LARC) patients after neoadjuvant therapy (NT) is needed. PURPOSE: To compare the cDWI and aDWI in image quality, restaging, and treatment response of LARC after NT. STUDY TYPE: Retrospective. POPULATION: Eighty-seven consecutive patients. FIELD STRENGTH/SEQUENCE: 3.0 T/DWI. ASSESSMENT: All patients underwent two DWI sequences, including conventional acquisition with b = 0 and 1000 s/mm2 (aDWIb1000 ) and another with b = 0 and 700 s/mm2 on a 3.0-T MR scanner. The images of the latter were used to compute the diffusion images with b = 1000 s/mm2 (cDWIb1000 ). Four radiologists with 3, 4, 14, and 25 years of experience evaluated the images to compare the image quality, TN restaging performance, and treatment response between aDWIb1000 and cDWIb1000 . STATISTICAL TESTS: Interclass correlation coefficients, weighted κ coefficient, paired Wilcoxon, and McNemar or Fisher test were used. A significance level of 0.05 was used. RESULTS: The cDWIb1000 images were superior to the aDWIb1000 ones in both subjective and objective image quality. In T restaging, the overall diagnostic accuracy of cDWIb1000 images was higher than that of aDWIb1000 images (57.47% vs. 49.43%, P = 0.289 for the inexperienced radiologist; 77.01% vs. 63.22%, significant for the experienced radiologist), with better sensitivity in determining ypT0-Tis tumors. Additionally, it increased the sensitivity in detecting ypT2 tumors for the inexperienced radiologist and ypT3 tumors for the experienced radiologist. N restaging and treatment response were found to be similar between two sequences for both radiologists. DATA CONCLUSION: Compared to aDWIb1000 images, the computed ones might serve as a wise approach, providing comparable or better image quality, restaging performance, and treatment response assessment for LARC after NT. LEVEL OF EVIDENCE: 3 TECHNICAL EFFICACY STAGE: 2.


Assuntos
Terapia Neoadjuvante , Neoplasias Retais , Humanos , Estudos Retrospectivos , Imagem de Difusão por Ressonância Magnética/métodos , Neoplasias Retais/diagnóstico por imagem , Neoplasias Retais/terapia , Reto/patologia
9.
J Magn Reson Imaging ; 60(5): 1904-1915, 2024 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-38236577

RESUMO

BACKGROUND: Nigrosome 1 (N1), the largest nigrosome region in the ventrolateral area of the substantia nigra pars compacta, is identifiable by the "N1 sign" in long echo time gradient echo MRI. The N1 sign's absence is a vital Parkinson's disease (PD) diagnostic marker. However, it is challenging to visualize and assess the N1 sign in clinical practice. PURPOSE: To automatically detect the presence or absence of the N1 sign from true susceptibility weighted imaging by using deep-learning method. STUDY TYPE: Prospective. POPULATION/SUBJECTS: 453 subjects, including 225 PD patients, 120 healthy controls (HCs), and 108 patients with other movement disorders, were prospectively recruited including 227 males and 226 females. They were divided into training, validation, and test cohorts of 289, 73, and 91 cases, respectively. FIELD STRENGTH/SEQUENCE: 3D gradient echo SWI sequence at 3T; 3D multiecho strategically acquired gradient echo imaging at 3T; NM-sensitive 3D gradient echo sequence with MTC pulse at 3T. ASSESSMENT: A neuroradiologist with 5 years of experience manually delineated substantia nigra regions. Two raters with 2 and 36 years of experience assessed the N1 sign on true susceptibility weighted imaging (tSWI), QSM with high-pass filter, and magnitude data combined with MTC data. We proposed NINet, a neural model, for automatic N1 sign identification in tSWI images. STATISTICAL TESTS: We compared the performance of NINet to the subjective reference standard using Receiver Operating Characteristic analyses, and a decision curve analysis assessed identification accuracy. RESULTS: NINet achieved an area under the curve (AUC) of 0.87 (CI: 0.76-0.89) in N1 sign identification, surpassing other models and neuroradiologists. NINet localized the putative N1 sign within tSWI images with 67.3% accuracy. DATA CONCLUSION: Our proposed NINet model's capability to determine the presence or absence of the N1 sign, along with its localization, holds promise for enhancing diagnostic accuracy when evaluating PD using MR images. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY: Stage 1.


Assuntos
Aprendizado Profundo , Imageamento por Ressonância Magnética , Doença de Parkinson , Substância Negra , Humanos , Feminino , Masculino , Doença de Parkinson/diagnóstico por imagem , Estudos Prospectivos , Pessoa de Meia-Idade , Imageamento por Ressonância Magnética/métodos , Idoso , Substância Negra/diagnóstico por imagem , Curva ROC , Adulto , Reprodutibilidade dos Testes , Interpretação de Imagem Assistida por Computador/métodos
10.
J Magn Reson Imaging ; 2024 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-38344910

RESUMO

BACKGROUND: Pretreatment identification of microvascular invasion (MVI) in hepatocellular carcinoma (HCC) is important when selecting treatment strategies. PURPOSE: To improve models for predicting MVI and recurrence-free survival (RFS) by developing nomograms containing three-dimensional (3D) MR elastography (MRE). STUDY TYPE: Prospective. POPULATION: 188 patients with HCC, divided into a training cohort (n = 150) and a validation cohort (n = 38). In the training cohort, 106/150 patients completed a 2-year follow-up. FIELD STRENGTH/SEQUENCE: 1.5T 3D multifrequency MRE with a single-shot spin-echo echo planar imaging sequence, and 3.0T multiparametric MRI (mp-MRI), consisting of diffusion-weighted echo planar imaging, T2-weighted fast spin echo, in-phase out-of-phase T1-weighted fast spoiled gradient-recalled dual-echo and dynamic contrast-enhanced gradient echo sequences. ASSESSMENT: Multivariable analysis was used to identify the independent predictors for MVI and RFS. Nomograms were constructed for visualization. Models for predicting MVI and RFS were built using mp-MRI parameters and a combination of mp-MRI and 3D MRE predictors. STATISTICAL TESTS: Student's t-test, Mann-Whitney U test, chi-squared or Fisher's exact tests, multivariable analysis, area under the receiver operating characteristic curve (AUC), DeLong test, Kaplan-Meier analysis and log rank tests. P < 0.05 was considered significant. RESULTS: Tumor c and liver c were independent predictors of MVI and RFS, respectively. Adding tumor c significantly improved the diagnostic performance of mp-MRI (AUC increased from 0.70 to 0.87) for MVI detection. Of the 106 patients in the training cohort who completed the 2-year follow up, 34 experienced recurrence. RFS was shorter for patients with MVI-positive histology than MVI-negative histology (27.1 months vs. >40 months). The MVI predicted by the 3D MRE model yielded similar results (26.9 months vs. >40 months). The MVI and RFS nomograms of the histologic-MVI and model-predicted MVI-positive showed good predictive performance. DATA CONCLUSION: Biomechanical properties of 3D MRE were biomarkers for MVI and RFS. MVI and RFS nomograms were established. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY: Stage 2.

11.
Eur Radiol ; 34(10): 6568-6577, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38676731

RESUMO

OBJECTIVES: This study aimed to compare the image quality and diagnostic performance of standard-resolution (SR) and ultra-high-resolution (UHR) coronary CT angiography (CCTA) based on photon-counting detector CT (PCD-CT) of coronary stents and explore the best reconstruction kernel for stent imaging. METHODS: From July 2023 to September 2023, patients were enrolled to undergo CCTA using a dual-source PCD-CT system after coronary angioplasty with stent placement. SR images with a slice thickness/increment of 0.6/0.4 mm were reconstructed using a vascular kernel (Bv48), while UHR images with a slice thickness/increment of 0.2/0.2 mm were reconstructed using vascular kernels of six sharpness levels (Bv48, Bv56, Bv60, Bv64, Bv72, and Bv76). The in-stent lumen diameters were evaluated. Subjective image quality was also evaluated by a 5-point Likert scale. Invasive coronary angiography was conducted in 12 patients (25 stents). RESULTS: Sixty-nine patients (68.0 [61.0, 73.0] years, 46 males) with 131 stents were included. All UHR images had significantly larger in-stent lumen diameter than SR images (p < 0.001). Specifically, UHR-Bv72 and UHR-Bv76 for in-stent lumen diameter (2.17 [1.93, 2.63] mm versus 2.20 [1.93, 2.59] mm) ranked the two best kernels. The subjective analysis demonstrated that UHR-Bv72 images had the most pronounced effect on reducing blooming artifacts, showcasing in-stent lumen and stent demonstration, and diagnostic confidence (p < 0.001). Furthermore, SR and UHR-Bv72 images showed a diagnostic accuracy of 78.3% (95% confidence interval [CI]: 56.3%-92.5%) and 88.0% (95%CI: 68.8%-97.5%), respectively. CONCLUSION: UHR CCTA by PCD-CT leads to significantly improved visualization and diagnostic performance of coronary stents, and Bv72 is the optimal reconstruction kernel showing the stent struts and in-stent lumen. CLINICAL RELEVANCE STATEMENT: The significantly improved visualization of coronary stents using ultra-high resolution CCTA could increase the diagnostic accuracy for in-stent restenosis and avoid unnecessary invasive quantitative coronary angiography, thus changing the clinical management for patients after percutaneous coronary intervention. KEY POINTS: Coronary stent imaging is challenging with energy-integrating detector CT due to "blooming artifacts." UHR images using a PCD-CT enhanced coronary stent visualization. UHR coronary stent imaging demonstrated improved diagnostic accuracy in clinical settings.


Assuntos
Angiografia por Tomografia Computadorizada , Angiografia Coronária , Stents , Humanos , Feminino , Masculino , Idoso , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Pessoa de Meia-Idade , Fótons , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia
12.
AJR Am J Roentgenol ; 222(5): e2330631, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38323783

RESUMO

BACKGROUND. Use of virtual monoenergetic images (VMIs) from multienergy CT scans can mitigate inconsistencies in traditional attenuation measurements that result from variation in scan-related factors. Photon-counting detector (PCD) CT systems produce VMIs as standard image output under flexible scanning conditions. OBJECTIVE. The purpose of this article was to evaluate the consistency of monoenergetic attenuation measurements obtained from a clinical PCD CT scanner across a spectrum of scanning paradigms. METHODS. A phantom with 10 tissue-simulating inserts was imaged using a clinical dual-source PCD CT scanner. Nine scanning paradigms were obtained across combinations of tube voltages (90, 120, and 140 kVp) and image quality (IQ) levels (80, 145, and 180). Images were reconstructed at VMI levels of 50, 60, 70, and 80 keV. Consistency of attenuation measurements was assessed, using the 120 kVp with IQ level of 145 scanning paradigm as the reference scan. RESULTS. For all scanning paradigms, attenuation measurements showed intra-class correlation of 0.999 and higher with respect to the reference scan. Across inserts, mean bias relative to the reference scan ranged from -14.9 to 13.6 HU, -2.7 to 1.7 HU, and -3.9 to 3.8 HU at tube voltages of 90, 120, and 140 kVp, respectively; and from -14.9 to 13.6 HU, -6.4 to 3.8 HU, -3.7 to 1.4 HU, and -7.2 to 4.3 HU at VMI levels of 50, 60, 70, and 80 keV, respectively. Thus, mean bias did not exceed 5 HU for any insert at tube potentials of 120 kVp and 140 kVp, nor for any insert at a VMI level of 70 keV. At a VMI level of 50 keV and tube potential of 90 kVp, mean bias exceeded 5 HU for 14 of 30 possible combinations of inserts and scanning paradigms and exceeded 10 HU for four of 30 such combinations. At VMI levels of both 60 and 80 keV, mean bias exceeded 5 HU for only two combinations of inserts and scanning paradigms, all at a tube potential of 90 kVp. CONCLUSION. PCD CT generally provided consistent attenuation measurements across combinations of scanning paradigms and VMI levels. CLINICAL IMPACT. PCD CT may facilitate quantitative applications of CT data in clinical practice.


Assuntos
Imagens de Fantasmas , Fótons , Tomografia Computadorizada por Raios X , Tomografia Computadorizada por Raios X/métodos , Humanos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Reprodutibilidade dos Testes
13.
AJR Am J Roentgenol ; 2024 Oct 09.
Artigo em Inglês | MEDLINE | ID: mdl-39382533

RESUMO

Background: Head and neck CTA requires fine detail evaluation, including characterization of potentially very small vessels and intrastent lumens. Blooming artifacts also hinder evaluation. Objectives: To evaluate image quality of ultra-high-resolution (UHR) photon-counting detector (PCD) CTA of the head and neck and to explore variation of such quality across reconstruction kernels. Methods: This prospective study included patients who underwent clinically indicated head and neck CTA from September 2023 to December 2023. Participants underwent PCD CTA in UHR mode. Reconstructions for each examination included a reference reconstruction (reflecting clinical protocols) using 0.8-mm slice thickness and Bv40 kernel, and six UHR reconstructions using 0.2-mm slice thickness and kernels of varying sharpness (Bv48-Bv80). Quantitative measures were recorded. Two radiologists independently evaluated qualitative measures using Likert scales (1=lowest quality; 5=highest quality). Results: The analysis included 103 participants (mean age, 61.3±13.0 years; 56 male, 48 female). Median vessel sharpness (in HU/mm) was 100.9 for reference reconstruction, and for UHR varied from 110.0 for Bv46 to 121.6 for Bv76 and 134.7 for Bv80. Median right internal carotid artery C2 luminal diameter was 3.8 mm for reference reconstruction, and for UHR increased from 4.1 mm for Bv48 to 4.9 mm for Bv80. For both readers, median overall image quality for reference reconstruction was 3, and for UHR was highest for Bv64 (5); calcified plaque blooming artifact for reference reconstruction was 1, and for UHR was highest for Bv72 (5) and Bv76 (5); stent blooming artifact for reference reconstruction was 1, and for UHR was highest for Bv76 (5) and Bv80 (5); soft-plaque delineation for reference reconstruction was 1, and for UHR was highest for Bv76 (5) or Bv80 (5); small-vessel visualization for reference reconstruction was 1, and for UHR was highest for Bv76 (5) or Bv80 (5). Conclusion: UHR-PCD CTA yielded reduced blooming artifact from calcified plaques or stents, and improved softplaque and small-vessel visualization. These advantages were more pronounced for strongest kernels, although subjective image quality was better for a weaker kernel. Clinical impact: The findings indicate benefits from use of UHR-PCD CTA for head and neck evaluation and may help guide such examinations' kernel selection.

14.
J Periodontal Res ; 59(1): 32-41, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37842947

RESUMO

OBJECTIVE: This study aimed to assess the association between the Mediterranean diet (MedDiet) and periodontitis in US adults and to further explore the mediating roles of obesity indicators in this association. BACKGROUND DATA: The relationship between MedDiet and periodontitis is controversial. And it is unclear whether obesity indicators are potential mediators of this relationship. METHODS: Using data derived from the National Health and Nutrition Examination Survey (2009-2014). Weighted binary logistic regression and restricted cubic spline were used to assess the association between MedDiet and periodontitis. Weighted ordinal logistic regression was performed to evaluate the relationship between MedDiet and periodontitis severity. The mediating roles of body mass index (BMI) and waist circumference in the relationship between the MedDiet and periodontitis were explored. Association analyses were further performed using mean clinical attachment loss (CAL) or mean periodontal probing depth (PPD) as dependent variables. The false discovery rate method was used to correct the p-values in the regression analyses. RESULTS: A total of 8290 eligible participants (4159 participants with periodontitis and 4131 without periodontitis) were included. A negative association between the MedDiet adherence score and periodontitis was observed in the binary logistic regression model (adjusted odds ratio = 0.94, 95% confidence interval: 0.90-0.97, p = .001). Restricted cubic spline regression revealed a dose-response relationship between the MedDiet adherence score and periodontitis. BMI and waist circumference significantly mediate this association, with mediation proportions of 9.7% (p = .032) and 9.3% (p = .012), respectively. Multivariable ordinal logistic regression showed that the MedDiet adherence score was negatively associated with the severity of periodontitis (all p < .05). Additionally, the MedDiet adherence score was negatively associated with mean PPD or mean CAL (all p < .05). CONCLUSIONS: This study suggests a significant negative association between adherence to the MedDiet and periodontitis and a possible mediating role of obesity indicators in this association. Furthermore, studies are still warranted to confirm our findings.


Assuntos
Dieta Mediterrânea , Periodontite , Adulto , Humanos , Inquéritos Nutricionais , Obesidade/complicações , Periodontite/epidemiologia , Periodontite/prevenção & controle , Periodontite/complicações , Índice de Massa Corporal
15.
Brain ; 146(7): 2780-2791, 2023 07 03.
Artigo em Inglês | MEDLINE | ID: mdl-36623929

RESUMO

Aberrant dynamic switches between internal brain states are believed to underlie motor dysfunction in Parkinson's disease. Deep brain stimulation of the subthalamic nucleus is a well-established treatment for the motor symptoms of Parkinson's disease, yet it remains poorly understood how subthalamic stimulation modulates the whole-brain intrinsic motor network state dynamics. To investigate this, we acquired resting-state functional magnetic resonance imaging time-series data from 27 medication-free patients with Parkinson's disease (mean age: 64.8 years, standard deviation: 7.6) who had deep brain stimulation electrodes implanted in the subthalamic nucleus, in both on and off stimulation states. Sixteen matched healthy individuals were included as a control group. We adopted a powerful data-driven modelling approach, known as a hidden Markov model, to disclose the emergence of recurring activation patterns of interacting motor regions (whole-brain intrinsic motor network states) via the blood oxygen level-dependent signal detected in the resting-state functional magnetic resonance imaging time-series data from all participants. The estimated hidden Markov model disclosed the dynamics of distinct whole-brain motor network states, including frequency of occurrence, state duration, fractional coverage and their transition probabilities. Notably, the data-driven decoding of whole-brain intrinsic motor network states revealed that subthalamic stimulation reshaped functional network expression and stabilized state transitions. Moreover, subthalamic stimulation improved motor symptoms by modulating key trajectories of state transition within whole-brain intrinsic motor network states. This modulation mechanism of subthalamic stimulation was manifested in three significant effects: recovery, relieving and remodelling effects. Significantly, recovery effects correlated with improvements in tremor and posture symptoms induced by subthalamic stimulation (P < 0.05). Furthermore, subthalamic stimulation was found to restore a relatively low level of fluctuation of functional connectivity in all motor regions to a level closer to that of healthy participants. Also, changes in the fluctuation of functional connectivity between motor regions were associated with improvements in tremor and gait symptoms (P < 0.05). These findings fill a gap in our knowledge of the role of subthalamic stimulation at the level of neural activity, revealing the regulatory effects of subthalamic stimulation on whole-brain inherent motor network states in Parkinson's disease. Our results provide mechanistic insight and explanation for how subthalamic stimulation modulates motor symptoms in Parkinson's disease.


Assuntos
Estimulação Encefálica Profunda , Doença de Parkinson , Núcleo Subtalâmico , Humanos , Pessoa de Meia-Idade , Tremor , Estimulação Encefálica Profunda/métodos , Imageamento por Ressonância Magnética
16.
BMC Cardiovasc Disord ; 24(1): 597, 2024 Oct 26.
Artigo em Inglês | MEDLINE | ID: mdl-39462356

RESUMO

BACKGROUND: To clarify the fat attenuation index (FAI) change trend of peri-saphenous vein graft (SVG) and determine the association between FAI and graft disease progression based on CCTA images. METHODS: Patients with venous coronary artery bypass grafts (CABGs) were consecutively enrolled in this retrospective study. In study 1, 72 patients who had undergone 1, 3, and 5 years of CCTA examinations without graft occlusion were recruited, and generalized estimation equation was used to analyze the peri-SVG FAI change trend over time. In study 2, 42 patients with graft disease progression and 84 patients as controls were propensity score-matched. Generalized linear mixed model and continuous net reclassification improvement (NRI) were used for assessing the associations with graft disease progression. Multivariable Cox regression analysis was used for assessing risk factors predicting cardiac events. RESULTS: In study 1, both the FAI of proximal right coronary artery and SVG decreased over time. In study 2, the 1-year CTA-derived FAI of grafts and graft anastomosis were independent indicators of graft disease progression at the 3-year CCTA follow-up (graft: odds ratio [OR] = 1.106; 95% confidence interval [CI] = 1.030-1.188, P = 0.006; graft anastomosis: OR = 1.170, 95% CI = 1.091-1.254, P < 0.001). Inclusion of the graft anastomosis FAI significantly improved reclassification compared with graft FAI (continuous NRI = 0.638, 95% CI: 0.345-0.931, P < 0.001). Moreover, The graft anastomosis FAI was found to be a risk factor for cardiac events after CABG and no statistically significant difference was found in the graft FAI (graft anastomosis: HR = 1.158, 95% CI = 1.034-1.297, P = 0.011; graft: HR = 1.116, 95% CI = 0.995-1.251, P = 0.061). CONCLUSIONS: A synchronism was found in the FAI change trend between native coronary artery and venous graft, which both decreased over time. The CCTA-derived FAI of venous grafts showed the potential of demonstrating SVG disease progression and graft anastomosis served as the optimal measured location.


Assuntos
Angiografia por Tomografia Computadorizada , Angiografia Coronária , Ponte de Artéria Coronária , Doença da Artéria Coronariana , Progressão da Doença , Oclusão de Enxerto Vascular , Valor Preditivo dos Testes , Veia Safena , Humanos , Masculino , Feminino , Ponte de Artéria Coronária/efeitos adversos , Ponte de Artéria Coronária/tendências , Estudos Retrospectivos , Pessoa de Meia-Idade , Idoso , Fatores de Tempo , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia , Veia Safena/transplante , Veia Safena/diagnóstico por imagem , Oclusão de Enxerto Vascular/etiologia , Oclusão de Enxerto Vascular/diagnóstico por imagem , Oclusão de Enxerto Vascular/fisiopatologia , Resultado do Tratamento , Fatores de Risco , Tecido Adiposo/diagnóstico por imagem , Tecido Adiposo/transplante , Medição de Risco
17.
J Clin Periodontol ; 51(8): 1054-1065, 2024 08.
Artigo em Inglês | MEDLINE | ID: mdl-38736143

RESUMO

AIM: To investigate the association between periodontal macrophage polarization states and the alveolar bone levels, and to assess whether glycosylated nano-hydroxyapatites (GHANPs) could improve bone regeneration in periodontitis by inducing macrophage M2 polarization. MATERIALS AND METHODS: The change of macrophage polarization state in inflammatory periodontal tissues (with bone loss) was examined using clinical gingival samples. The relationship between macrophage phenotype and bone level in periodontal bone loss and repair was evaluated using a mouse periodontitis model. The effect of GHANPs on macrophage polarization was assessed by the in vitro model of lipopolysaccharide (LPS)-stimulated inflammation. The polarization-related markers were detected by immunofluorescence staining, real-time polymerase chain reaction and enzyme-linked immunosorbent assay analysis. The therapeutic effect of GHANPs on alveolar bone loss was explored in experimental periodontitis by histological staining and micro-CT analysis. RESULTS: A lower macrophage M2/M1 ratio was observed in periodontitis-affected human gingival tissues. The results of animal experiments demonstrated a positive correlation between a lower Arg-1/iNOS ratio and accelerated alveolar bone loss; also, the proportion of Arg-1-positive macrophages increased during bone repair and regeneration. The administration of GHANPs partially restored M2 macrophage polarization after LPS stimulation. GHANPs increased alveolar bone repair and regeneration in experimental periodontitis induced by ligation, potentially related to their macrophage M2 transition regulation. CONCLUSIONS: The findings of this study indicate that the induction of macrophage M2 polarization can be considered a viable approach for enhancing inflammatory bone repair. Additionally, GHANPs show potential in the clinical treatment of periodontitis.


Assuntos
Perda do Osso Alveolar , Regeneração Óssea , Macrófagos , Periodontite , Animais , Regeneração Óssea/efeitos dos fármacos , Periodontite/terapia , Camundongos , Macrófagos/efeitos dos fármacos , Humanos , Modelos Animais de Doenças , Masculino , Glicosilação , Nanopartículas , Feminino , Camundongos Endogâmicos C57BL
18.
J Clin Periodontol ; 51(4): 441-451, 2024 04.
Artigo em Inglês | MEDLINE | ID: mdl-38158854

RESUMO

AIM: To explore the association between polycyclic aromatic hydrocarbons (PAHs) (measured using urinary metabolites) and periodontitis using data from the National Health and Nutrition Examination Survey 2009-2014. MATERIALS AND METHODS: Weighted binary logistic regression, Bayesian kernel machine regression (BKMR) and weighted quantile sum (WQS) regression were used to evaluate independent and joint associations between the six urinary monohydroxylated metabolites of PAHs (OH-PAHs) and periodontitis. RESULTS: In all, 3413 participants were included in this study. All six urinary OH-PAHs were present at higher levels in the periodontitis group compared with the non-periodontitis group (p < .001). Fully adjusted multivariable logistic regressions showed positive associations between the six urinary OH-PAHs and periodontitis (p < .05). Higher concentrations of OH-PAHs were also positively associated with attachment loss, periodontal pocket depth (PPD) and the number of tooth loss. BKMR and WQS regression yielded similar positive associations between OH-PAH mixtures and periodontitis. CONCLUSIONS: PAHs and their mixture are positively associated with periodontitis, which may provide novel insights into periodontitis prevention from an environmental exposure perspective.


Assuntos
Periodontite , Hidrocarbonetos Policíclicos Aromáticos , Humanos , Teorema de Bayes , Inquéritos Nutricionais , Periodontite/epidemiologia , Bolsa Periodontal , Hidrocarbonetos Policíclicos Aromáticos/efeitos adversos
19.
BMC Oral Health ; 24(1): 243, 2024 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-38360594

RESUMO

OBJECTIVES: To investigate the association between serum per- and polyfluoroalkyl substances (PFAS) and periodontitis, and further explore the possible mediating role of sex hormones in this association. METHODS: We extracted data from National Health and Nutrition Examination Survey (NHANES) 2009-2014. Univariable and multivariable logistic regression models were performed to investigate the association between serum levels of seven PFASs and periodontitis. Bayesian kernel machine regression (BKMR) was conducted to assess the joint effect of PFASs in mixtures. Mediation analyses were used to explore the potential mediating role of sex hormones. RESULTS: Participants with periodontitis had higher concentrations of serum perfluorooctane sulfonate (PFOS) and perfluorononanoic acid (PFNA) than those without periodontitis (both P < 0.05). In fully adjusted models, high serum concentrations of PFOS and PFNA were positively associated with periodontitis (tertile 3 vs. tertile 1: prevalence ratio (PR) = 1.19 for PFOS, 95% CI: 1.01-1.39; PR = 1.17 for PFNA, 95% CI: 1.02-1.34). The results from the BKMR models consistently showed a positive association between PFAS mixtures and periodontitis. Of note, testosterone and the ratio of testosterone to estradiol significantly mediated the relationship between high level of PFOS and periodontitis, accounting for 16.5% and 31.7% of the total effect, respectively. Sensitivity analyses yielded similar results when using periodontal clinical indices (mean loss of attachment, mean periodontal probing depth, and the number of teeth) as dependent variables. CONCLUSIONS: These findings provide evidence to support a positive association between certain PFASs and periodontitis, which might be partially mediated by sex hormones.


Assuntos
Ácidos Alcanossulfônicos , Poluentes Ambientais , Ácidos Graxos , Fluorocarbonos , Periodontite , Humanos , Inquéritos Nutricionais , Teorema de Bayes , Hormônios Esteroides Gonadais , Testosterona
20.
BMC Oral Health ; 24(1): 1025, 2024 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-39215278

RESUMO

BACKGROUND: Brominated flame retardants (BFRs) are widely utilized to mitigate the flammability of various materials. Previous studies have revealed the impact of BFRs exposure on hormonal disruption and bone metabolism which are closely related to periodontitis. However, it remains unknown the potential relationship between BFRs and periodontitis. This study aimed to explore the association between BFRs exposure and periodontitis in US adults. METHODS: The data analyzed in this study were obtained from the National Health and Nutrition Examination Survey (NHANES) 2009-2014. Twelve serum BFRs were quantified using isotope dilution gas chromatography high-resolution mass spectrometry. Univariable and multivariable logistic regression was employed to evaluate the association between serum BFRs and periodontitis. Bayesian kernel machine regression (BKMR) analyses were utilized to assess the association between mixtures of BFRs and periodontitis. RESULTS: A total of 3311 eligible participants were included. Serum BFRs (PBDE-47, PBDE-99, and PBDE-154) were significantly associated with periodontitis, and the odds ratios (ORs) and corresponding 95% confidence intervals(CIs) were 1.15(1.01,1.29), 1.10(1.01,1.20), and 1.12(1.01,1.25), respectively. Notably, these three BFRs were also significantly associated with the severity of periodontitis. Additionally, the BKMR model revealed a significant association between the mixture of all twelve BFRs and periodontitis. CONCLUSIONS: This preliminary study suggests a significant association between specific serum BFRs (PBDE-47, PBDE-99, and PBDE-154) and periodontitis and its severity. Further prospective and experimental studies are warranted to validate our findings.


Assuntos
Retardadores de Chama , Inquéritos Nutricionais , Periodontite , Humanos , Retardadores de Chama/análise , Periodontite/sangue , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Estados Unidos/epidemiologia , Éteres Difenil Halogenados/sangue , Teorema de Bayes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA