Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 534
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
J Cardiovasc Electrophysiol ; 35(6): 1174-1184, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38867544

RESUMO

INTRODUCTION: The left ventricular summit (LVS) is the highest point on the epicardial surface of the left ventricle. A part of the LVS that is located between the left coronary arteries (lateral-LVS) is one of the major sites of idiopathic ventricular arrhythmia (VA) origins. Some idiopathic epicardial VAs can be ablated at endocardial sites adjacent to the epicardial area septal to the lateral-LVS (septal-LVS). This study examined the prevalence and electrocardiographic and electrophysiological characteristics of septal-LVS VAs. METHODS: We studied consecutive patients with idiopathic VAs originating from the LVS (67 patients) and aortic root (93 patients). RESULTS: Based on the ablation results, among 67 LVS VAs, 54 were classified as lateral and 13 as septal-LVS VAs. As compared with the lateral-LVS VAs, the septal-LVS VAs were characterized by a greater prevalence of left bundle branch block with left inferior-axis QRS pattern, later precordial transition, lower R-wave amplitude ratio in leads III to II, lower Q-wave amplitude ratio in leads aVL to aVR, and later local ventricular activation time relative to the QRS onset during VAs (V-QRS) in the great cardiac vein. The electrocardiographic and electrophysiological characteristics of the septal-LVS VAs were similar to those of the aortic root VAs. However, the V-QRS at the successful ablation site was significantly later during the septal-LVS VAs than aortic root VAs (p < .0001). The precordial transition was significantly later during the septal-LVS VAs than aortic root VAs (p < .05). CONCLUSIONS: Septal-LVS VAs are considered a distinct subgroup of idiopathic VAs originating from the left ventricular outflow tract.


Assuntos
Potenciais de Ação , Ablação por Cateter , Eletrocardiografia , Técnicas Eletrofisiológicas Cardíacas , Valor Preditivo dos Testes , Humanos , Feminino , Masculino , Prevalência , Pessoa de Meia-Idade , Adulto , Idoso , Resultado do Tratamento , Frequência Cardíaca , Ventrículos do Coração/fisiopatologia , Ventrículos do Coração/cirurgia , Taquicardia Ventricular/fisiopatologia , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Taquicardia Ventricular/epidemiologia , Estudos Retrospectivos , Fatores de Tempo
2.
Cardiovasc Diabetol ; 23(1): 121, 2024 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-38581024

RESUMO

BACKGROUND: This study investigates the relationship between triglyceride-glucose (TyG) index trajectories and the results of ablation in patients with stage 3D atrial fibrillation (AF). METHODS: A retrospective cohort study was carried out on patients who underwent AF Radiofrequency Catheter Ablation (RFCA) at the Cardiology Department of the Fourth Affiliated Hospital of Zhejiang University and Taizhou Hospital of Zhejiang Province from January 2016 to December 2022. The main clinical endpoint was determined as the occurrence of atrial arrhythmia for at least 30 s following a 3-month period after ablation. Using a latent class trajectory model, different trajectory groups were identified based on TyG levels. The relationship between TyG trajectory and the outcome of AF recurrence in patients was assessed through Kaplan-Meier survival curve analysis and multivariable Cox proportional hazards regression model. RESULTS: The study included 997 participants, with an average age of 63.21 ± 9.84 years, of whom 630 were males (63.19%). The mean follow-up period for the participants was 30.43 ± 17.75 months, during which 200 individuals experienced AF recurrence. Utilizing the minimum Bayesian Information Criterion (BIC) and the maximum Entropy principle, TyG levels post-AF RFCA were divided into three groups: Locus 1 low-low group (n = 791), Locus 2 low-high-low group (n = 14), and Locus 3 high-high group (n = 192). Significant differences in survival rates among the different trajectories were observed through the Kaplan-Meier curve (P < 0.001). Multivariate Cox regression analysis showed a significant association between baseline TyG level and AF recurrence outcomes (HR = 1.255, 95% CI: 1.087-1.448). Patients with TyG levels above 9.37 had a higher risk of adverse outcomes compared to those with levels below 8.67 (HR = 2.056, 95% CI: 1.335-3.166). Furthermore, individuals in Locus 3 had a higher incidence of outcomes compared to those in Locus 1 (HR = 1.580, 95% CI: 1.146-2). CONCLUSION: The TyG trajectories in patients with stage 3D AF are significantly linked to the outcomes of AF recurrence. Continuous monitoring of TyG levels during follow-up may help in identifying patients at high risk of AF recurrence, enabling the early application of effective interventions.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Feminino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/etiologia , Estudos Retrospectivos , Teorema de Bayes , Resultado do Tratamento , Fatores de Risco , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Recidiva
3.
BMC Cardiovasc Disord ; 24(1): 178, 2024 Mar 23.
Artigo em Inglês | MEDLINE | ID: mdl-38521897

RESUMO

AIMS: The current management of patients with atrial fibrillation (AF) and concomitant heart failure (HF) remains a significant challenge. Catheter ablation (CA) has been shown to improve left ventricular ejection fraction (LVEF) in these patients, but which patients can benefit from CA is still poorly understood. The aim of our study was to determine the predictors of improved ejection fraction in patients with persistent atrial fibrillation (PeAF) complicated with HF undergoing CA. METHODS AND RESULTS: A total of 435 patients with persistent AF underwent an initial CA between January 2019 and March 2023 in our hospital. We investigated consecutive patients with left ventricular systolic dysfunction (LVEF < 50%) measured by transthoracic echocardiography (TTE) within one month before CA. According to the LVEF changes at 6 months, these patients were divided into an improved group (fulfilling the '2021 Universal Definition of HF' criteria for LVEF recovery) and a nonimproved group. Eighty patients were analyzed, and the improvement group consisted of 60 patients (75.0%). In the univariate analysis, left ventricular end-diastolic diameter (P = 0.005) and low voltage zones in the left atrium (P = 0.043) were associated with improvement of LVEF. A receiver operating characteristic analysis determined that the suitable cutoff value for left ventricular end-diastolic diameter (LVDd) was 59 mm (sensitivity: 85.0%, specificity: 55.0%, area under curve: 0.709). A multivariate analysis showed that LVDd (OR = 0.85; 95% CI: 0.76-0.95, P = 0.005) and low voltage zones (LVZs) (OR = 0.26; 95% CI: 0.07-0.96, P = 0.043) were significantly independently associated with the improvement of LVEF. Additionally, parameters were significantly improved regarding the left atrial diameter, LVDd and ventricular rate after radiofrequency catheter ablation (all p < 0.05). CONCLUSIONS: The improvement of left ventricular ejection fraction (LVEF) occurred in 75.0% of patients. Our study provides additional evidence that LVDd < 59 mm and no low voltage zones in the left atrium can be used to jointly predict the improvement of LVEF after atrial fibrillation ablation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Insuficiência Cardíaca , Disfunção Ventricular Esquerda , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/complicações , Função Ventricular Esquerda , Volume Sistólico , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/complicações , Disfunção Ventricular Esquerda/etiologia , Disfunção Ventricular Esquerda/complicações , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Resultado do Tratamento
4.
Artigo em Inglês | MEDLINE | ID: mdl-38319640

RESUMO

A 60-year-old male patient suffered from frequent episodes of atrial tachycardia (AT), after the index procedure of catheter ablation for paroxysmal atrial fibrillation. During the repeat procedure, the activation map showed that the earliest activation site was located at the roof of left atrium. Multiple ablations at the earliest activation site on the roof failed to terminate the AT; however, ablation within the pulmonary artery at an adjacent anatomical site successfully eliminated the AT, even without recording distinct near-field potential.

5.
Echocardiography ; 41(3): e15779, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38477165

RESUMO

BACKGROUND: Radiofrequency catheter ablation (RFCA) is an effective method for controlling the heart rate of paroxysmal atrial fibrillation (PAF). However, recurrence is trouble under the RFCA. To gain a deeper understanding of the risk factors for recurrence in patients, we created a nomogram model to provide clinicians with treatment recommendations. METHODS: A total of two hundred thirty-three patients with PAF treated with RFCA at Guizhou Medical University Hospital between January 2021 and December 2022 were consecutively included in this study, and after 1 year of follow-up coverage, 166 patients met the nadir inclusion criteria. Patients with AF were divided into an AF recurrence group and a non-recurrence group. The nomogram was constructed using univariate and multivariate logistic regression analyses. By calculating the area under the curve, we analyzed the predictive ability of the risk scores (AUC). In addition, the performance of the nomogram in terms of calibration, discrimination, and clinical utility was evaluated. RESULTS: At the 12-month follow-up, 48 patients (28.92%) experienced a recurrence of AF after RFCA, while 118 patients (71.08%) maintained a sinus rhythm. In addition to age, sex, and TRV, LAD, and TTPG were independent predictors of recurrence of RFCA. The c-index of the nomogram predicted AF recurrence with an accuracy of .723, showing good decision curves and a calibrated nomogram, as determined by internal validation using a bootstrap sample size of 1000. CONCLUSION: We created a nomogram based on multifactorial logistic regression analysis to estimate the probability of recurrence in patients with atrial fibrillation 1 year after catheter ablation. This plot can be utilized by clinicians to predict the likelihood of recurrence.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Ablação por Radiofrequência , Humanos , Resultado do Tratamento , Nomogramas , Valor Preditivo dos Testes , Fatores de Risco , Ablação por Cateter/métodos , Catéteres , Recidiva
6.
Pediatr Cardiol ; 45(2): 368-376, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38071252

RESUMO

In verapamil-sensitive left posterior fascicular ventricular tachycardia (LPF-VT), radiofrequency catheter ablation (RFA) is performed targeting mid-to-late diastolic potential (P1) and presystolic potential (P2) during tachycardia. This study included four patients who had undergone electrophysiological study (EPS) and pediatric patients with verapamil-sensitive LPF-VT who had undergone RFA using high-density three-dimensional (3D) mapping. The included patients were 11-14 years old. During EPS, right bundle branch block and superior configuration VT were induced in all patients. VT mapping was performed via the transseptal approach. P1 and P2 during VT were recorded in three of the four patients. All patients initially underwent RFA via the transseptal approach. In three patients, P1 during VT was targeted, and VT was terminated. The lesion size indices in which VT was terminated were 4.6, 4.6, and 4.7. For one patient whose P1 could not be recorded, linear ablation was performed perpendicularly in the area where P2 was recorded during VT. Among the three patients in whom VT was terminated, linear ablation was performed in two to eliminate the ventricular echo beats. In all patients, VT became uninducible in the acute phase and had not recurred 8-24 months after RFA. High-density 3D mapping with an HD Grid Mapping Catheter allows recording of P1 and P2 during VT and may improve the success rate of RFA in pediatric patients with verapamil-sensitive LPF-VT.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Humanos , Criança , Adolescente , Taquicardia Ventricular/cirurgia , Eletrocardiografia , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/cirurgia , Bloqueio de Ramo , Ablação por Cateter/métodos , Verapamil/uso terapêutico , Resultado do Tratamento
7.
Medicina (Kaunas) ; 60(7)2024 Jul 03.
Artigo em Inglês | MEDLINE | ID: mdl-39064518

RESUMO

Background and Objectives: Radiofrequency catheter ablation (RFCA) is a highly successful intervention. By comparing the lesion changes in prostate parenchymal and striated muscle tissues after RFCA with and without cooling, it was possible to assess the correlation between the shape regularity, area, and perimeter of the thermal lesion, and to predict the geometric shape changes of the lesions. Materials and Methods: A standard prostate and striated muscle RFCA procedure was performed on 13 non-purebred dogs in two sessions: no cooling and cooling with 0.1% NaCl solution. Microtome-cut 2-3 µm sections of tissue samples were stained with haematoxylin and eosin and further examined. The quotient formula was employed to evaluate the geometric shape of the damage zones at the ablation site. Results: The extent of injury following RFCA in striated muscle tissue was comparable to that in prostate parenchymal tissue. Regression analysis indicated a strong and positive relationship between area and perimeter in all experimental groups. In the experimental groups of parenchymal tissues with and without cooling, an increase in the area or perimeter of the damage zone corresponded to an increase in the quotient value. A similar tendency was observed in the striated muscle group with cooling. However, in the striated muscle group without cooling, an increase in lesion area or perimeter lowered the quotient value. Standardised regression coefficients demonstrated that in the striated muscle with cooling, the damage zone shape was more determined by area than perimeter. However, in the parenchymal tissue, the perimeter had a more substantial impact on the damage zone shape than the area. Conclusions: The damage area and perimeter have predictive power on the overall shape regularity of damage zone geometry in both striated muscles and parenchymal tissue. This approach is employed to achieve a balance between the need for tumour eradication and the minimisation of ablation-induced complications to healthy tissue.


Assuntos
Ablação por Cateter , Músculo Estriado , Animais , Masculino , Ablação por Cateter/métodos , Ablação por Cateter/efeitos adversos , Cães , Tecido Parenquimatoso , Próstata/cirurgia , Próstata/patologia , Músculo Esquelético/lesões
8.
J Cardiovasc Electrophysiol ; 34(1): 189-196, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36349711

RESUMO

INTRODUCTION: This study aimed to elucidate the relationship between premature ventricular complexes (PVCs) and right ventricular (RV) dysfunction, and the effects of radiofrequency catheter ablation (RFCA) on RV function. METHODS: A total of 110 patients (age, 50.8 ± 14.4 years; 30 men) without structural heart disease who had undergone RFCA for RV outflow tract (RVOT) PVCs were retrospectively included. RV function was assessed using fractional area change (FAC) and global longitudinal strain (GLS) before and after RFCA. Clinical data were compared between the RV dysfunction (n = 63) and preserved RV function (n = 47) groups. The relationship between PVC burden and RV function was analyzed. Change in RV function before and after RFCA was compared between patients with successful and failed RFCA. RESULTS: PVC burden was significantly higher in the RV dysfunction group than in the preserved RV function group (p < .001). FAC and GLS were significantly worse in proportion to PVC burden (p < .001 and p < .001, respectively). The risk factor associated with RV dysfunction was PVC burden [odds ratio (95% confidence interval), 1.092 (1.052-1.134); p < .001]. Improvement in FAC (13.0 ± 8.7% and -2.5 ± 5.6%, respectively; p < .001) and GLS (-6.8 ± 5.7% and 2.1 ± 4.2%, respectively; p < .001) was significant in the patients with successful RFCA, compared to the patients in whom RFCA failed. CONCLUSIONS: Frequent RVOT PVCs are associated with RV dysfunction. RV dysfunction is reversible by successful RFCA.


Assuntos
Ablação por Cateter , Disfunção Ventricular Direita , Complexos Ventriculares Prematuros , Masculino , Humanos , Adulto , Pessoa de Meia-Idade , Idoso , Estudos Retrospectivos , Função Ventricular Direita , Resultado do Tratamento , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/cirurgia , Complexos Ventriculares Prematuros/diagnóstico , Complexos Ventriculares Prematuros/cirurgia , Complexos Ventriculares Prematuros/complicações , Ablação por Cateter/efeitos adversos , Disfunção Ventricular Direita/diagnóstico por imagem , Disfunção Ventricular Direita/etiologia , Disfunção Ventricular Direita/cirurgia
9.
J Cardiovasc Electrophysiol ; 34(6): 1350-1359, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36598422

RESUMO

INTRODUCTION: The Heliostar™ ablation system is a novel RF balloon ablation technology with an integrated three-dimensional mapping system. Here, we describe our early experience and procedural outcomes using this technology for atrial fibrillation catheter ablation. METHODS: We sought to comprehensively assess the first 60 consecutive patients undergoing pulmonary vein isolation using the novel HELISOTAR™ RF balloon technology including procedural outcomes. A comparison of the workflow between two different anaesthetic modalities (conscious sedation [CS] vs. general anaesthesia [GA]) was made. Procedural data were collected prospectively from two high-volume centers (Barts Heart Centre, UK and University Hospital of Zurich, Zurich). A standardized approach for catheter ablation was employed. RESULTS: A total of 35 patients had the procedure under CS and the remaining under GA. Mean procedural and fluoroscopy times were 84 ± 33 min and 1.1 min. The median duration of RF energy application was 7 (5-9.8) mins per patient. All veins were successfully isolated, and the median isolation time was 10 (7-15) seconds. Our cohort's rate of procedural complications was low, with no mortality within 30 days postprocedure. CONCLUSION: Our early experience shows that catheter ablation using the Heliostar™ technology can be performed efficiently and safely; however, long-term data is yet to be established. Low fluoroscopy requirements, short learning curves and use of this technology with CS is possible, including the use of an oesophageal temperature probe.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Resultado do Tratamento , Europa (Continente) , Eletrodos , Veias Pulmonares/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos
10.
J Cardiovasc Electrophysiol ; 34(1): 117-125, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36403284

RESUMO

INTRODUCTION: Intramural or epicardial locations of the arrhythmogenic substrate are regarded as one of the main reasons for radiofrequency (RF) catheter ablation failure. This study aims to conduct a comprehensive analysis of various factors including baseline impedance, irrigant and electrode configuration at similar ablation index (AI) value. METHODS: In 12 ex vivo swine hearts, RF ablation was performed at a target AI value of 500 and a multistep impedance load (100-180 Ω) in 4 settings: (1) conventional unipolar configuration with an irrigant of normal saline (NS); (2) conventional unipolar configuration with an irrigant of half normal saline (HNS); (3) bipolar configuration with an irrigant of NS; (4) sequential unipolar configuration with an irrigant of NS. The relationships between lesion dimensions and above factors were examined. RESULTS: Baseline impedance had a strong negative linear correlation with lesion dimensions at a certain AI. The correlation coefficient between baseline impedance and depth, width, and volume were R = -0.890, R = -0.755 and R = -0.813, respectively (p < .01). There were 10 (total: 10/100, 10%; bipolar: 10/25, 40%) transmural lesions during the whole procedure. Bipolar ablation resulted in significantly deeper lesion than other electrode configurations. Other comparisons in our experiment did not achieve statistical significance. CONCLUSION: There is a strong negative linear correlation between baseline impedance and lesion dimensions at a certain AI value. Baseline impedance has an influence on the overall lesion dimensions among irrigated fluid and ablation configurations. Over a threshold impedance of 150 Ω, the predictive accuracy of AI can be compromised.


Assuntos
Ablação por Cateter , Solução Salina , Suínos , Animais , Impedância Elétrica , Coração , Eletrodos , Arritmias Cardíacas , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos
11.
J Cardiovasc Electrophysiol ; 34(12): 2573-2580, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37890039

RESUMO

INTRODUCTION: Accessory pathway (AP) ablation is a straightforward approach with high success rates, but the fluoroscopy time (FT) is significantly longer in conventional technique. Electroanatomical mapping systems (EMS), reduce the FT, but anatomical and activation mapping may prolong the procedure time (PT). The fluoroscopy integration module (FIM) uses prerecorded fluoroscopy images and allows ablation similar to conventional technique without creating an anatomical map. In this study, we investigated the effects of combining the FIM with traditional technique on PT, success, and radiation exposure. METHODS: A total of 131 patients who had undergone AP ablation were included in our study. In 37 patients, right and left anterior oblique (RAO-LAO) images were acquired after catheter placement and integrated with the FIM. The ablation procedure was then similar to the conventional technique, but without the use of fluoroscopy. For the purpose of acceleration, anatomical and activation maps have not been created. Contact-force catheters were not used. 94 patients underwent conventional ablation using fluoroscopy only. RESULTS: FIM into AP ablation procedures led to a significant reduction in radiation exposure, lowering FT from 7.4 to 2.8 min (p < .001) and dose-area product from 12.47 to 5.8 µGym² (p < .001). While the FIM group experienced a reasonable longer PT (69 vs. 50 min p < .001). FIM reduces FT regardless of operator experience and location of APs CONCLUSION: Combining FIM integration with conventional AP ablation offers reduced radiation exposure without compromising success rates and complication.


Assuntos
Feixe Acessório Atrioventricular , Ablação por Cateter , Humanos , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Doses de Radiação , Feixe Acessório Atrioventricular/diagnóstico por imagem , Feixe Acessório Atrioventricular/cirurgia , Fatores de Tempo , Fluoroscopia/métodos , Resultado do Tratamento
12.
Europace ; 25(10)2023 Oct 05.
Artigo em Inglês | MEDLINE | ID: mdl-37695314

RESUMO

AIMS: Stereotactic arrhythmia radioablation (STAR) has been recently introduced for the management of therapy-refractory ventricular tachycardia (VT). VT recurrences have been reported after STAR but the mechanisms remain largely unknown. We analysed recurrences in our patients after STAR. METHODS AND RESULTS: From 09.2017 to 01.2020, 20 patients (68 ± 8 y, LVEF 37 ± 15%) suffering from refractory VT were enrolled, 16/20 with a history of at least one electrical storm. Before STAR, an invasive electroanatomical mapping (Carto3) of the VT substrate was performed. A mean dose of 23 ± 2 Gy was delivered to the planning target volume (PTV). The median ablation volume was 26 mL (range 14-115) and involved the interventricular septum in 75% of patients. During the first 6 months after STAR, VT burden decreased by 92% (median value, from 108 to 10 VT/semester). After a median follow-up of 25 months, 12/20 (60%) developed a recurrence and underwent a redo ablation. VT recurrence was located in the proximity of the treated substrate in nine cases, remote from the PTV in three cases and involved a larger substrate over ≥3 LV segments in two cases. No recurrences occurred inside the PTV. Voltage measurements showed a significant decrease in both bipolar and unipolar signal amplitude after STAR. CONCLUSION: STAR is a new tool available for the treatment of VT, allowing for a significant reduction of VT burden. VT recurrences are common during follow-up, but no recurrences were observed inside the PTV. Local efficacy was supported by a significant decrease in both bipolar and unipolar signal amplitude.

13.
Cardiovasc Drugs Ther ; 37(6): 1117-1129, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35731452

RESUMO

BACKGROUND: This study aimed to establish and assess a prediction model for patients with persistent atrial fibrillation (AF) treated with nifekalant during the first radiofrequency catheter ablation (RFCA). METHODS: In this study, 244 patients with persistent AF from January 17, 2017 to December 14, 2017, formed the derivation cohort, and 205 patients with persistent AF from December 15, 2017 to October 28, 2018, constituted the validation cohort. The least absolute shrinkage and selection operator regression was used for variable screening and the multivariable Cox survival model for nomogram development. The accuracy and discriminative capability of this predictive model were assessed according to discrimination (area under the curve [AUC]) and calibration. Clinical practical value was evaluated using decision curve analysis. RESULTS: Body mass index, AF duration, sex, left atrial diameter, and the different responses after nifekalant administration were identified as AF recurrence-associated factors, all of which were selected for the nomogram. In the development and validation cohorts, the AUC for predicting 1-year AF-free survival was 0.863 (95% confidence interval (CI) 0.801-0.926) and 0.855 (95% CI 0.782-0.929), respectively. The calibration curves showed satisfactory agreement between the actual AF-free survival and the nomogram prediction in the derivation and validation cohorts. In both groups, the prognostic score enabled stratifying the patients into different AF recurrence risk groups. CONCLUSIONS: This predictive nomogram can serve as a quantitative tool for estimating the 1-year AF recurrence risk for patients with persistent AF treated with nifekalant during the first RFCA.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/cirurgia , Prognóstico , Resultado do Tratamento , Recidiva , Ablação por Cateter/efeitos adversos
14.
Artigo em Inglês | MEDLINE | ID: mdl-37160503

RESUMO

CONTEXT: A nomogram model affecting the activated clotting time (ACT) targeting rate during radiofrequency ablation of atrial fibrillation (RFCA) in China. PURPOSE: The aim of this study is to develop and validate a nomogram model for predicting the activated clotting time targeting rate after the initial bolus heparin dosages during the radiofrequency catheter ablation of atrial fibrillation in China. METHODS AND RESULTS: A retrospective observational study was conducted on the data of 465 patients with atrial fibrillation who underwent radiofrequency catheter ablation (RFCA) from October 2019 to June 2022. All patients were randomized into a training cohort (70%; n = 325) and a validation cohort (30%; n = 140). Independent risk factors were identified using univariate and multifactorial logistic regression analysis. The predictive nomogram model was established using R software. The nomogram was developed and evaluated based on differentiation, calibration, and clinical efficacy using concordance statistic (C-statistic), calibration plots, and decision curve analysis (DCA), respectively. The nomogram was established using three variables, including sex (OR 1.01, 95% CI 0.29-1.76, P = 0.007), heparin dose (OR 0.04; 95%CI 0.02-0.05, P < 0.001), and the baseline ACT (OR 0.03; 95%CI 0.02-0.04, P < 0.001). The C-statistic of the nomogram was 0.736 (95%CI 0.675-0.732) in the training cohort and 0.700 (95%CI 0.622-0.721) in the validation cohort. The calibration plots showed good agreement between the predictions and observations in the training and validation cohorts. The clinical decision curve also proves that the map is useful in clinical settings. CONCLUSION: The nomogram model has good discrimination and accuracy, which can screen attainment groups intuitively and individually, and has a certain predictive value for the probability of ACT reaching the target after the adequate dosage of initial heparin in Chinese patients with atrial fibrillation.

15.
Artigo em Inglês | MEDLINE | ID: mdl-38103153

RESUMO

BACKGROUND: The objective of this study is to establish and validate a nomogram model for predicting the probability of silent cerebral infarction following ablation of atrial fibrillation. METHODS AND RESULTS: A retrospective observational study was conducted on the data of 238 patients with atrial fibrillation who underwent radiofrequency ablation in our hospital from October 2019 to December 2022. LASSO regression and multivariate logistics regression analysis were used to assess the independent risk factors for silent cerebral infarction after ablation. The AUC of the predictive model was 0.733 (95% CI, 0.649-0.816) and the internal validation (bootstrap = 1000) of the bootstrap method was 0.733 (95% CI 0.646-0.813). The Hosmer-Lemeshow test yields an insignificant p-value of X-squared = 10.212 and p-value = 0.2504, thus indicating an insignificant difference between predicted and observed values and good calibration results. The clinical impact curve (CIC) and clinical decision curve also prove that this graph is useful in the clinical setting. CONCLUSION: We developed an easy-to-use nomogram model to predict the probability of silent cerebral infarction following radiofrequency ablation of atrial fibrillation. This model can provide a valid assessment of the probability of postoperative silent cerebral infarction in patients undergoing radiofrequency ablation of atrial fibrillation.

16.
BMC Cardiovasc Disord ; 23(1): 192, 2023 04 13.
Artigo em Inglês | MEDLINE | ID: mdl-37055734

RESUMO

BACKGROUND: Postcardiac injury syndrome (PCIS) is an easy-to-miss diagnosis, but it is not an uncommon complication. The phenomenon of echocardiography (ECHO) showing both severe pulmonary arterial hypertension (PAH) and severe tricuspid regurgitation (TR) is indeed rare in PCIS after extensive radiofrequency ablation. CASE PRESENTATION: A 70-year-old male was diagnosed with persistent atrial fibrillation. The patient received radiofrequency catheter ablation due to his atrial fibrillation being refractory to antiarrhythmic drugs. After the anatomical three-dimensional models were created, ablations were performed on the left and right pulmonary veins, roof linear and bottom linear of the left atrium, and the cavo-tricuspid isthmus. The patient was discharged in sinus rhythm (SR). After 3 days, he was admitted to the hospital for gradually worsening dyspnea. Laboratory examination showed a normal leukocyte count with an increased percentage of neutrophils. The erythrocyte sedimentation rate, C-reactive protein concentration, interleukin-6, and N-terminal pro-B-type natriuretic peptide were elevated. ECG exhibited SR, V1-V4 of precordial lead P-wave amplitude which was increased but not prolonged, PR segment depression, and ST-segment elevation. Computed tomography angiography of the pulmonary artery revealed that the lung had scattered high-density flocculent flakes and a small amount of pleural and pericardial effusion. Local pericardial thickening was seen. ECHO showed severe PAH with severe TR. Diuretics and vasodilators did not relieve the symptoms. Tumors, tuberculosis, and immune system diseases were all excluded. Considering the patient's diagnosis of PCIS, the patient was treated with steroids. The patient recovered on the 19th day post ablation. The patient's condition was maintained until 2 years of follow-up. CONCLUSIONS: The phenomenon of ECHO showing severe PAH with severe TR is indeed rare in PCIS. Due to the lack of diagnostic criteria, such patients are easily misdiagnosed, leading to a poor prognosis.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Hipertensão Pulmonar , Hipertensão Arterial Pulmonar , Insuficiência da Valva Tricúspide , Masculino , Humanos , Idoso , Hipertensão Arterial Pulmonar/diagnóstico , Hipertensão Arterial Pulmonar/etiologia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/etiologia , Insuficiência da Valva Tricúspide/cirurgia , Átrios do Coração , Hipertensão Pulmonar/cirurgia , Hipertensão Pulmonar Primária Familiar , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Resultado do Tratamento
17.
Pacing Clin Electrophysiol ; 46(6): 487-497, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36633015

RESUMO

BACKGROUND: Although Lesion size index (LSI) has been reported to highly predict radiofrequency lesion size in vitro, its accuracy in lesion size and steam pop estimation has not been well investigated for every possible scenario. METHODS: Initially, radiofrequency ablations were performed on porcine myocardial slabs at various power, CF, and time settings with blinded LSI. Subsequently, radiofrequency power at 20, 30, 40, 50, and 60 W was applied at CF values of 5, 10, 20, and 30 g to reach target LSIs of 4, 5, 6, and 7. Lesion size and steam pops were recorded for each ablation. RESULTS: Lesion size was positively correlated with LSI regardless of power settings (p < 0.001). The linear correlation coefficients of lesion size and LSI decreased at higher power settings. At high power combined with high CF settings (50 W/20 g), lesion depth and LSI showed an irrelevant correlation (p = 0.7855). High-power ablation shortened ablation time and increased the effect of resistive heating. LSI could predict the risk of steam pops at high-power settings with the optimal threshold of 5.65 (sensitivity, 94.1%; specificity, 46.1%). The ablation depth of the heavy heart was shallower than that of the light heart under similar ablation settings. CONCLUSIONS: LSI could predict radiofrequency lesion size and steam pops at high power settings in vitro, while synchronous high power and high CF should be avoided. Lighter hearts require relatively lower ablation settings to create appropriate ablation depth.


Assuntos
Ablação por Cateter , Vapor , Suínos , Animais , Miocárdio/patologia
18.
Pacing Clin Electrophysiol ; 46(2): 152-160, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36524673

RESUMO

BACKGROUND: Although premature atrial contractions (PACs) just after catheter ablation (CA) for atrial fibrillation (AF) are common, their clinical significance is uncertain. This study aimed to evaluate whether the PAC burden after an initial CA for AF was associated with late recurrence. METHODS: We enrolled 346 patients with AF (median age, 65 years; 30% female; 57% with paroxysmal AF) who underwent an initial radiofrequency CA and a 24-h Holter monitoring the day after the procedure. PAC was defined as supraventricular complexes occurring ≥30% earlier than expected compared with a previous RR interval, and the number of PAC/24 h during post-procedural Holter monitoring was analyzed. RESULTS: AF recurred in 106 patients (31%) during a median follow-up of 19 months. These patients had significantly more PAC/24 h than those without (median [interquartile range], 891 [316-4351] beats vs. 409 [162-1,303] beats; p < 0.01). The number of PACs was independently associated with AF recurrence after adjustment for clinical parameters and left atrial (LA) enlargement. Receiver operating characteristic (ROC) curve analysis revealed that 1431 PAC/24 h was the optimal cut-off value for predicting AF recurrence. Adding the PAC/24 h to the prediction model with LA diameter appeared to correctly reclassify patients who were thought to be at high risk for AF recurrence into the low-risk group and vice versa. CONCLUSIONS: The number of PACs was an independent risk factor for AF recurrence. A 24-h Holter recording the day after an initial CA is a simple and beneficial tool for the risk stratification of AF recurrence.


Assuntos
Fibrilação Atrial , Complexos Atriais Prematuros , Ablação por Cateter , Humanos , Feminino , Idoso , Masculino , Resultado do Tratamento , Fatores de Risco , Ablação por Cateter/efeitos adversos , Recidiva
19.
Int J Med Sci ; 20(10): 1293-1299, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37786440

RESUMO

OBJECTIVE: Radiofrequency catheter ablation (RFCA) is a safe and effective treatment for paroxysmal supraventricular tachycardia in adults. However, data on its use in children, particularly from low- and middle-income countries, are limited. This study aimed to evaluate the safety and efficacy of RFCA in children with paroxysmal supraventricular tachycardia from Vietnam. METHODS: A prospective study was conducted from January 2009 to July 2016 at the University Medical Center, Ho Chi Minh City, Vietnam. Ninety-five children diagnosed with paroxysmal supraventricular tachycardia were enrolled; 90 patients underwent cardiac electrophysiology and RFCA. The patients were followed up for 3-12 months, with a mean follow-up period of 7.5 ± 2.3 months. RESULTS: The average age of the patients was 10.5 ± 3 years, with the youngest patient being 4 years old; 46.3% of the patients were female and 53.7% were male. The patients' average weight was 35.2 ± 9.6 kg. Atrioventricular reentrant tachycardia accounted for 72.6% of the cases and atrioventricular nodal reentrant tachycardia for 27.4% of the cases; no patients had atrial tachycardia. The success rate of RFCA was 98.9% (89/90 patients). During the 12-month follow-up, 5.6% of the patients experienced recurrence but were successfully treated with a second ablation. No severe complications were reported during the procedure and follow-up. CONCLUSIONS: This study found RFCA to be a safe and effective treatment for paroxysmal supraventricular tachycardia in children. It demonstrated a high success rate and low recurrence and complication rates for RFCA in children, thereby highlighting the potential advantages of the procedure as a treatment option.


Assuntos
Ablação por Cateter , Taquicardia por Reentrada no Nó Atrioventricular , Taquicardia Supraventricular , Taquicardia Ventricular , Adulto , Humanos , Masculino , Criança , Feminino , Adolescente , Pré-Escolar , Estudos Prospectivos , Taquicardia Supraventricular/epidemiologia , Taquicardia Supraventricular/cirurgia , Resultado do Tratamento , Taquicardia Ventricular/cirurgia , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos
20.
Echocardiography ; 40(10): 1048-1057, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37548034

RESUMO

OBJECTIVES: Although radiofrequency catheter ablation (RFCA) has become an important treatment strategy for paroxysmal or persistent atrial fibrillation (AF), AF recurrence after RFCA remains an important issue that plagues clinicians and patients. This study aimed to investigate the association of left atrial (LA) and left atrial appendage (LAA) mechanics with AF recurrence after RFCA and to compare their prognostic values in patients with AF undergoing RFCA. METHODS: A total of 160 patients with non-valvular AF who underwent RFCA for the first time were included in this study. All patients underwent transthoracic echocardiography (TTE) and transesophageal echocardiography (TEE) before the procedure. All patients were followed up for one year after RFCA, and AF recurrence was recorded. Speckle-tracking echocardiography was used to measure LA and LAA global longitudinal strain (GLS). LA and LAA mechanical dispersion (MD) were defined as the standard deviation of time to peak strain at each segment standardized by the R-R interval. Logistic regression analysis was used to analyze independent contributors for AF recurrence after RFCA. The prediction efficiency of factors associated with the presence of AF recurrence was evaluated by the receiver operating characteristic (ROC) curve with area under curve (AUC). RESULTS: During 1-year follow-up, 45 (28%) patients had recurrence, and 115 (72%) patients had no recurrence. The age, CHA2 DS2 -VASc score, NT-proBNP, LA volume index (LAVI), LA MD, and LAA MD of patients in recurrence group were significantly higher than those in no recurrent group (p < .05). The LAA emptying fraction (LAAEF), LA GLS, and LAA GLS in recurrence group were significantly lower than those in no recurrent group (p < .05). Logistic regression analysis showed that LA and LAA GLS were independent contributors for AF recurrence (p < .05), providing incremental values. The AUCs of LA and LAA GLS in predicting AF recurrence were higher than that of other factors, and the LA GLS+LAA GLS joint model had higher prediction efficiency. CONCLUSION: This study demonstrated the LA and LAA GLS were independent contributors for AF recurrence after RFCA and provided incremental values. LA and LAA GLS can be used as the predictor of AF recurrence after RFCA, and they may be beneficial for the risk stratification of AF recurrence.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Ablação por Cateter , Humanos , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Apêndice Atrial/cirurgia , Átrios do Coração , Prognóstico , Recidiva
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA