Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 67
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Mikrochim Acta ; 191(3): 163, 2024 02 28.
Artigo em Inglês | MEDLINE | ID: mdl-38413431

RESUMO

Carbendazim (CBD) is widely used as a fungicide that acts as a pesticide in farming to prevent crop diseases. However, CBD can remain on crops for a long time. When consumed by humans and animals, it produces a range of toxic symptoms and poses a serious threat to their health. Therefore, the detection of CBD is necessary. Traditional assay strategies for CBD detection, although sensitive and practical, can hardly achieve fast, robust monitoring during food processing and daily life. Here, we designed a novel electrochemical sensor for CBD detection. In this method, iron oxyhydroxide nanomaterial (ß-FeOOH) was first prepared by hydrothermal method. Then, a molecularly imprinted polymer (MIP) layer was electropolymerized on the surface using CBD as the template and resorcinol (RC) as the functional monomer. The synergistic interaction between ß-FeOOH and MIP endows the MIP/ß-FeOOH/CC-based electrochemical sensor with high specificity and sensitivity. Under optimal conditions, the MIP/ß-FeOOH/CC-based sensor showed a wide linear range of 39 pM-80 nM for CBD and a detection limit as low as 25 pM. Therefore, the as-prepared sensor can be a practical and effective tool for pesticide residue detection.


Assuntos
Benzimidazóis , Carbamatos , Compostos Férricos , Impressão Molecular , Polímeros , Animais , Humanos , Polímeros/química , Impressão Molecular/métodos , Polímeros Molecularmente Impressos
2.
Sensors (Basel) ; 24(16)2024 Aug 14.
Artigo em Inglês | MEDLINE | ID: mdl-39204956

RESUMO

2-Furaldehyde (2-FAL) is one of the main by-products of the degradation of hemicellulose, which is the solid material of the oil-paper insulating system of oil-filled transformers. For this reason, it has been suggested as a marker of the degradation of the insulating system; sensing devices for 2-FAL analysis in a wide concentration range are of high interest in these systems. An optical sensor system is proposed; this consists of a chemical chip, able to capture 2-FAL from the insulating oil, coupled with a surface plasmon resonance (SPR) probe, both realized on multimode plastic optical fibers (POFs). The SPR platform exploits gold nanofilm or, alternatively, a double layer of gold and silicon oxide to modulate the sensor sensitivity. The capturing chip is always based on the same molecularly imprinted polymer (MIP) as a receptor specific for 2-FAL. The system with the SPR probe based on a gold nanolayer had a higher sensitivity and a lower detection limit of fractions of µg L-1. Instead, the SPR probe, based on a double layer (gold and silicon oxide), has a lower sensitivity with a worse detection limit, and it is suitable for the detection of 2-FAL at concentrations of 0.01-1 mg L-1.

3.
Int J Mol Sci ; 24(4)2023 Feb 18.
Artigo em Inglês | MEDLINE | ID: mdl-36835517

RESUMO

Biomarkers can provide critical information about cancer and many other diseases; therefore, developing analytical systems for recognising biomarkers is an essential direction in bioanalytical chemistry. Recently molecularly imprinted polymers (MIPs) have been applied in analytical systems to determine biomarkers. This article aims to an overview of MIPs used for the detection of cancer biomarkers, namely: prostate cancer (PSA), breast cancer (CA15-3, HER-2), epithelial ovarian cancer (CA-125), hepatocellular carcinoma (AFP), and small molecule cancer biomarkers (5-HIAA and neopterin). These cancer biomarkers may be found in tumours, blood, urine, faeces, or other body fluids or tissues. The determination of low concentrations of biomarkers in these complex matrices is technically challenging. The overviewed studies used MIP-based biosensors to assess natural or artificial samples such as blood, serum, plasma, or urine. Molecular imprinting technology and MIP-based sensor creation principles are outlined. Analytical signal determination methods and the nature and chemical structure of the imprinted polymers are discussed. Based on the reviewed biosensors, the results are compared, and the most suitable materials for each biomarker are discussed.


Assuntos
Biomarcadores Tumorais , Técnicas Biossensoriais , Polímeros Molecularmente Impressos , Neoplasias , Humanos , Impressão Molecular/métodos
4.
Bull Environ Contam Toxicol ; 108(4): 658-662, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34694444

RESUMO

hER-MIP is a molecularly imprinted polymer (MIP) that has been shown to selectively collect human estrogen receptor (hER) binding active substances. However, environmental samples contain various chemicals depending on the location and regional differences, and the hER binding activity depends on the sample type. Thus, the general applicability of hER-MIP to actual environmental samples must be elucidated. In this study, 48 environmental samples were collected and screened with hER-MIP, and a yeast assay was performed to evaluate the adsorption characteristics of the samples according to the adsorption and elution fractions. The results showed that hER-MIP collects hER binding active substances almost selectively but does not collect constitutive androstane receptor (CAR) binding active substances selectively. CAR binding activity was detected in the adsorbed fraction because several hER binding active substances also demonstrate CAR binding activity.


Assuntos
Disruptores Endócrinos , Poluentes Químicos da Água , Adsorção , Disruptores Endócrinos/análise , Estrona , Humanos , Polímeros/química , Poluentes Químicos da Água/análise
5.
Mikrochim Acta ; 188(8): 279, 2021 07 30.
Artigo em Inglês | MEDLINE | ID: mdl-34331135

RESUMO

Molecularly imprinted polymers are efficient and selective adsorbents which act as artificial receptors for desired compounds with the ability to recognize the size, shape, and functional groups of the compounds simultaneously. A molecularly imprinted polymer is prepared by the polymerization of functional monomers around a template (analyte) molecule. Afterward, the removal of the template from the polymer matrix leaves a selective cavity behind. The fabrication and development of molecularly imprinted polymers grew rapidly, due to their low cost, simple preparation, selectivity, sensitivity, and stable physicochemical properties. Traditionally, molecularly imprinted polymers can be synthesized using two main methods, namely bulk and surface imprinting. For more efficient use of the latter method, researchers have developed molecularly imprinted polymers grafted on the solid-phase matrix (substrate). This grafting technique would be particularly useful for surface imprinting of macromolecules, such as proteins. Cellulose fibers of papers with unique properties such as being abundant, retaining a porous structure, having good adsorption properties, and possessing hydroxyl groups naturally have gained much attention as substrate. The goal of this review is to introduce molecularly imprinted polymer-grafted or molecularly imprinted polymer-coated paper, as an interesting, simple, and efficient method in the detection and separation of small and large molecules. Therefore, in the present paper, several recent preparation techniques and applications of molecularly imprinted polymer-grafted paper are reviewed and discussed in detail. Green, cost-effective, selective, and sensitive paper-based sensor prepared via grafting molecularly imprinted polymer on paper surface with the potential use for online detection trace of analytes in the point-of-care testing.


Assuntos
Celulose/química , Cocaína/análise , Corantes Fluorescentes/química , Metanfetamina/análise , Polímeros Molecularmente Impressos/química , Adsorção , Técnicas Biossensoriais , Hidróxidos/química , Limite de Detecção , Metais/química , Metacrilatos/química , Impressão Molecular , Nanoestruturas/química , Nanotubos de Carbono/química , Papel , Polimerização , Porosidade , Pontos Quânticos/química , Dióxido de Silício/química , Espectrometria de Fluorescência , Propriedades de Superfície
6.
Sensors (Basel) ; 19(1)2019 Jan 06.
Artigo em Inglês | MEDLINE | ID: mdl-30621335

RESUMO

In recent years, along with the rapid development of relevant biological fields, there has been a tremendous motivation to combine molecular imprinting technology (MIT) with biosensing. In this situation, bioprobes and biosensors based on molecularly imprinted polymers (MIPs) have emerged as a reliable candidate for a comprehensive range of applications, from biomolecule detection to drug tracking. Unlike their precursors such as classic immunosensors based on antibody binding and natural receptor elements, MIPs create complementary cavities with stronger binding affinity, while their intrinsic artificial polymers facilitate their use in harsh environments. The major objective of this work is to review recent MIP bioprobes and biosensors, especially those used for biomolecules and drugs. In this review, MIP bioprobes and biosensors are categorized by sensing method, including optical sensing, electrochemical sensing, gravimetric sensing and magnetic sensing, respectively. The working mechanism(s) of each sensing method are thoroughly discussed. Moreover, this work aims to present the cutting-edge structures and modifiers offering higher properties and performances, and clearly point out recent efforts dedicated to introduce multi-sensing and multi-functional MIP bioprobes and biosensors applicable to interdisciplinary fields.


Assuntos
Biopolímeros/isolamento & purificação , Técnicas Biossensoriais/tendências , Impressão Molecular/tendências , Polímeros/química , Biopolímeros/química , Humanos , Ligação Proteica
7.
Molecules ; 24(13)2019 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-31248028

RESUMO

Molecularly imprinted polymer (MIP) and magnetic molecularly imprinted polymer (mag-MIP) for solid extraction and pre-concentration of quercetin have been successfully prepared by thermal polymerization method using quercetin (Q) as a template, acrylamide (AA) as a functional monomer, and ethylene glycol dimethacrylate (EGDMA) as a cross-linking agent. The MIP and mag-MIP were successfully applied in analysis of quercetin by mass spectrometry (MS) methods. To perform ambient plasma ionization experiments, a setup consisting of the heated crucible, a flowing atmospheric-pressure afterglow (FAPA) plasma ion source, and amaZon SL ion trap (Bruker, Bremen, Germany) was used. The heated crucible with programmable temperature allowed desorption of the analytes from MIPs structure which resulted in their direct introduction into the ion stream. The results of Q-MIP/Q-mag-MIP and FAPA-MS measurements were compared with those of the analysis of quercetin by the ESI-MS method without extractions and pre-concentration of analytes on polymers. Limits of detection (LOD) for quercetin solutions in both positive and negative ESI-MS were established at 10-8 M and 10-7 M, respectively. The linearity (R2 = 0.9999) of the proposed analytical procedure for quercetin determination in positive ions was provided in the range between 10-4 M and 10-7 M. Moreover, the same parameters were established for FAPA-MS in positive ions, reaching LOD at 0.005 mg/gMIP and the linearity of the method in the range of 0.015-0.075 mg/gMIP with the correlation coefficient value R2 = 0.9850.


Assuntos
Pressão Atmosférica , Impressão Molecular , Polímeros/química , Quercetina/química , Espectrometria de Massas por Ionização por Electrospray , Espectrometria de Massas por Ionização por Electrospray/métodos , Análise Espectral , Termogravimetria
8.
Anal Bioanal Chem ; 410(18): 4387-4395, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29736700

RESUMO

A novel molecularly imprinted quartz crystal microbalance (QCM) sensor was successfully prepared for selective determination of sialic acid (SA) in human urine samples. To obtain the QCM sensor, we first modified the gold surface of the QCM chip by self-assembling of allylmercaptane to introduce polymerizable double bonds on the chip surface. Then, SA molecularly imprinted polymer (MIP) nanofilm was attached to the modified QCM chip surface. For comparison, we have also characterized the nonmodified and improved surfaces of the QCM sensor by using atomic force microscopy (AFM) and Fourier transform infrared (FTIR) spectroscopy. We then tested the selectivity and detection limit of the imprinted QCM sensor via a series of adsorption experiments. The results show a linear response in the range of 0.025-0.50 µmol L-1 for sialic acid. Moreover, the limit of detection (LOD) of the prepared imprinted QCM sensor was found to be 1.0 nmol L-1 for sialic acid, and high recovery values range from 87.6 to 108.5% with RSD < 8.7 (n = 5) for the spiked urine sample obtained. Overall, this work presents how a novel QCM sensor was developed and used to detect sialic acid in human urine samples. Graphical abstract Specific recognition of sialic acid by the MIP-QCM sensor system.


Assuntos
Impressão Molecular/métodos , Ácido N-Acetilneuramínico/urina , Polímeros/química , Técnicas de Microbalança de Cristal de Quartzo/métodos , Desenho de Equipamento , Humanos , Limite de Detecção , Impressão Molecular/instrumentação , Nanoestruturas/química , Técnicas de Microbalança de Cristal de Quartzo/instrumentação , Propriedades de Superfície
9.
Sensors (Basel) ; 18(6)2018 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-29874860

RESUMO

A novel Molecularly Imprinted Polymer (MIP) able to bind perfluorinated compounds, combined with a surface plasmon resonance (SPR) optical fiber platform, is presented. The new MIP receptor has been deposited on a D-shaped plastic optical fiber (POF) covered with a photoresist buffer layer and a thin gold film. The experimental results have shown that the developed SPR-POF-MIP sensor makes it possible to selectively detect the above compounds. In this work, we present the results obtained with perfluorooctanoate (PFOA) compound, and they hold true when obtained with a perfluorinated alkylated substances (PFAs) mixture sample. The sensor's response is the same for PFOA, perfluorooctanesulfonate (PFOS) or PFA contaminants in the C4⁻C11 range. We have also tested a sensor based on a non-imprinted polymer (NIP) on the same SPR in a D-shaped POF platform. The limit of detection (LOD) of the developed chemical sensor was 0.13 ppb. It is similar to the one obtained by the configuration based on a specific antibody for PFOA/PFOS exploiting the same SPR-POF platform, already reported in literature. The advantage of an MIP receptor is that it presents a better stability out of the native environment, very good reproducibility, low cost and, furthermore, it can be directly deposited on the gold layer, without modifying the metal surface by functionalizing procedures.

10.
Molecules ; 23(8)2018 Jul 27.
Artigo em Inglês | MEDLINE | ID: mdl-30060497

RESUMO

To improve the chromatographic performance of an oseltamivir (OS) molecularly imprinted polymer (MIP), silica gel coated with an MIP layer for OS (OSMIP@silica gel) was prepared by the surface molecular imprinting technology on the supporter of porous silica gel microspheres. A nonimprinted polymer with the silica gel (NIP@silica gel) was also prepared for comparison. The obtained particles were characterized through FT⁻IR, scanning electron microscopy, specific surface area analysis, and porosity measurements. The results indicated that the polymer was successfully synthesized and revealed the structural differences between imprinted and nonimprinted polymers. The results of static adsorption experiments showed that adsorption quantity of the OSMIP@silica gel for OS was higher than that for NIP@silica gel, and the OSMIP@silica gel had two kinds of affinity sites for OS but the NIP@silica gel had one. The chromatographic performance of the OSMIP@silica gel column had significant improvement. The imprinting factor of the OSMIP@silica gel column for OS was 1.64. Furthermore, the OSMIP@silica gel column showed good affinity and selectivity for template OS and another neuraminidase inhibitor, peramivir, but not for quinocetone. These results indicated that the prepared OSMIP could be used to simulate the activity center of neuraminidase, and the OSMIP@silica gel column could be also employed in future studies to search for more active neuraminidase inhibitor analogues from traditional Chinese herbs.


Assuntos
Oseltamivir/química , Polímeros/síntese química , Sílica Gel/química , Cromatografia Líquida , Microscopia Eletrônica de Varredura , Microesferas , Impressão Molecular , Estrutura Molecular , Tamanho da Partícula , Polímeros/química
11.
J Sci Food Agric ; 98(6): 2089-2097, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28941229

RESUMO

BACKGROUND: Binary functional monomers, allyl-ß-cyclodextrin (allyl-ß-CD) and methacrylic acid (MAA) or allyl-ß-CD and acrylonitrile (AN), were exploited in a fabrication of molecularly imprinted polymers (MIPs) for selective recognition and large enrichment of pirimicarb from aqueous media. RESULTS: Special attention was paid to the computational simulation of the imprinting molecular and functional monomers. The morphological characteristics of MIPs made of allyl-ß-CD and MAA (M-MAA) were characterised by scanning electron microscopy. The effect of binding capacity of MAA-linked allyl-ß-CD MIPs (M-MAA) demonstrated higher efficiency than that of AN-linked allyl-ß-CD MIPs (M-AN) when tested in binding specificity. Finally, M-MAA was chosen to run through molecularly imprinted solid-phase extraction (MISPE) to analyse the spiked fresh leafy vegetables of pirimicarb. CONCLUSION: The present proposed technique is a promising tool for the preparation of the receptors which could recognise pirimicarb pesticide in aqueous media. © 2017 Society of Chemical Industry.


Assuntos
Carbamatos/química , Praguicidas/química , Pirimidinas/química , Extração em Fase Sólida/métodos , Poluentes Químicos da Água/química , beta-Ciclodextrinas/química , Adsorção , Carbamatos/isolamento & purificação , Metacrilatos/química , Impressão Molecular , Praguicidas/isolamento & purificação , Polímeros/síntese química , Polímeros/química , Pirimidinas/isolamento & purificação , Extração em Fase Sólida/instrumentação , Poluentes Químicos da Água/isolamento & purificação , beta-Ciclodextrinas/síntese química
12.
Sensors (Basel) ; 17(11)2017 Nov 09.
Artigo em Inglês | MEDLINE | ID: mdl-29120397

RESUMO

There is a global debate and concern about the use of glyphosate (Gly) as an herbicide. New toxicological studies will determine its use in the future under new strict conditions or its replacement by alternative synthetic or natural herbicides. In this context, we designed biomimetic polymer sensing layers for the selective molecular recognition of Gly. Towards this end, complementary surface acoustic wave (SAW) and electrochemical sensors were functionalized with polypyrrole (PPy)-imprinted polymer for the selective detection of Gly. Their corresponding limits of detection were on the order of 1 pM, which are among the lowest values ever reported in literature. The relevant dissociation constants between PPy and Gly were estimated at [Kd1 = (0.7 ± 0.3) pM and Kd2 = (1.6 ± 1.4) µM] and [Kd1 = (2.4 ± 0.9) pM and Kd2 = (0.3 ± 0.1) µM] for electrochemical and gravimetric measurements, respectively. Quantum chemical calculations permitted to estimate the interaction energy between Gly and PPy film: ΔE = -145 kJ/mol. Selectivity and competitivity tests were investigated with the most common pesticides. This work conclusively shows that gravimetric and electrochemical results indicate that both MIP-based sensors are perfectly able to detect and distinguish glyphosate without any ambiguity.

13.
J Mol Recognit ; 28(11): 667-78, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26095144

RESUMO

A surface acoustic wave sensor operating at 104 MHz and functionalized with a polypyrrole molecularly imprinted polymer has been designed for selective detection of dopamine (DA). Optimization of pyrrole/DA ratio, polymerization and immersion times permitted to obtain a highly selective sensor, which has a sensitivity of 0.55°/mM (≈ 550 Hz/mM) and a detection limit of ≈ 10 nM. Morphology and related roughness parameters of molecularly imprinted polymer surfaces, before and after extraction of DA, as well as that of the non imprinted polymer were characterized by atomic force microscopy. The developed chemosensor selectively recognized dopamine over the structurally similar compound 4-hydroxyphenethylamine (referred as tyramine), or ascorbic acid,which co-exists with DA in body fluids at a much higher concentration. Selectivity tests were also carried out with dihydroxybenzene, for which an unexpected phase variation of order of 75% of the DA one was observed. Quantum chemical calculations, based on the density functional theory, were carried out to determine the nature of interactions between each analyte and the PPy matrix and the DA imprinted PPy polypyrrole sensing layer in order to account for the important phase variation observed during dihydroxybenzene injection.


Assuntos
Dopamina/química , Polímeros/química , Pirróis/química , Limite de Detecção , Impressão Molecular/métodos , Polimerização
14.
Biomed Chromatogr ; 28(6): 907-12, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24861763

RESUMO

Molecular imprinting as a promising and facile separation technique has received much attention because of its high selectivity for target molecules. In this study, lysozyme molecularly imprinted polymers (Lys-MIPs) were successfully prepared by the entrapment method with lysozyme as the template molecule, acrylamide as the functional monomer and N,N-methylenebisacrylamide as the cross-linker. The removal of the template lysozyme from the molecularly imprinted polymers was investigated in detail by two methods. The synthesized Lys-MIPs were characterized by scanning electron microscopy and Fourier transform-infrared, and the adsorption capacity, selectivity and reproducibility of the Lys-MIPs were also evaluated. The maximum adsorption capacity reached 94.8 mg/g, which is twice that of nonmolecularly imprinted polymers, and satisfactory selectivity and reproducibility were achieved. Using the Lys-MIP column, lysozyme could be separated completely from egg white, with purity close to 100% and mass recovery of 98.2%. This illustrated that the synthesized Lys-MIPs had high specific recognition and selectivity to the template lysozyme when they were applied to a mixture of protein standards and a real sample.


Assuntos
Clara de Ovo/química , Muramidase/isolamento & purificação , Polímeros/química , Adsorção , Animais , Galinhas , Impressão Molecular , Muramidase/química , Polímeros/síntese química
15.
Biomed Chromatogr ; 28(3): 375-84, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24127240

RESUMO

A liquid chromatography tandem mass spectrometry (LC/MS/MS) method was developed and validated for the determination of five total tobacco-specific N-nitrosamines (TSNA), including free and conjugated forms in urine. The limits of detection for 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanol, N'-nitrosonornicotine, 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanone, N'-nitrosoanatabine and N'-nitrosoanabasine were 0.6, 0.6, 10.0, 0.4 and 0.4 pg/mL, respectively, with a linear calibration range of up to 20,000 pg/mL. Intra- and inter-day precision for TSNA measurements ranged from 0.82 to 3.67% and from 2.04 to 7.73% respectively. For total TSNAs, the ß-glucuronidase amount was optimized for hydrolysis time and yield. Different liquid chromatography columns and mobile phases with different pH conditions were evaluated. The validated method was then applied to 50 smoker and 30 nonsmoker urine samples. Our results suggest that this sensitive and relatively simple analytical method is suitable for application to epidemiological investigations of health risks associated with the exposure to tobacco smoke or secondhand smoke in both smokers and nonsmokers.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Nicotiana/química , Nitrosaminas/urina , Fumar/urina , Espectrometria de Massas em Tandem/métodos , Glucuronidase , Humanos , Hidrólise , Limite de Detecção , Impressão Molecular , Nitrosaminas/química , Reprodutibilidade dos Testes
16.
Biosens Bioelectron ; 255: 116269, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38579624

RESUMO

Saxitoxin (STX), which is produced by certain dinoflagellate species, is a type of paralytic shellfish poisoning toxin that poses a serious threat to human health and the environment. Therefore, developing a technology for the convenient and cost-effective detection of STX is imperative. In this study, we developed an affinity peptide-imprinted polymer-based indirect competitive ELISA (ic-ELISA) without using enzyme-toxin conjugates. AuNP/Co3O4@Mg/Al cLDH was synthesized by calcining AuNP/ZIF-67@Mg/Al LDH, which was obtained by combining AuNPs, ZIF-67, and flower-like Mg/Al LDH. This synthesized nanozyme exhibited high catalytic activity (Km = 0.24 mM for TMB and 132.5 mM for H2O2). The affinity peptide-imprinted polymer (MIP) was imprinted with an STX-specific template peptide (STX MIP) on a multi-well microplate and then reacted with an STX-specific signal peptide (STX SP). The interaction between the STX SP and MIP was detected using a streptavidin-coated nanozyme (SA-AuNP/Co3O4@Mg/Al cLDH). The developed MIP-based ic-ELISA exhibited excellent selectivity and sensitivity, with a limit of detection of 3.17 ng/mL (equivalent: 0.317 µg/g). Furthermore, the system was validated using a commercial ELISA kit and mussel tissue samples, and it demonstrated a high STX recovery with a low coefficient of variation. These results imply that the developed ic-ELISA can be used to detect STX in real samples.


Assuntos
Técnicas Biossensoriais , Cobalto , Nanopartículas Metálicas , Óxidos , Humanos , Toxinas Marinhas/análise , Polímeros Molecularmente Impressos , Ouro , Peróxido de Hidrogênio , Frutos do Mar/análise , Saxitoxina , Ensaio de Imunoadsorção Enzimática/métodos , Peptídeos , Polímeros
17.
J Hazard Mater ; 470: 134199, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38593660

RESUMO

Polycyclic aromatic hydrocarbons (PAHs) are priority pollutants and need to be measured reliably in waters and other media, to understand their sources, fate, behaviour and to meet regulatory monitoring requirements. Conventional water sampling requires large water volumes, time-consuming pre-concentration and clean-up and is prone to analyte loss or contamination. Here, for the first time, we developed and validated a novel diffusive gradients in thin-films (DGT) passive sampler for PAHs. Based on the well-known DGT principles, the sampler pre-concentrates PAHs with typical deployment times of days/weeks, with minimal sample handling. For the first time, DGT holding devices made of metal and suitable for sampling hydrophobic organic compounds were designed and tested. They minimize sorption and sampling lag times. Following tests on different binding layer resins, a MIP-DGT was preferred - the first time applying MIP for PAHs. It samples PAHs independent of pH (3.9 -8.1), ionic strength (0.01 -0.5 M) and dissolved organic matter < 20 mg L-1, making it suitable for applications across a wide range of environments. Field trials in river water and wastewater demonstrated that DGT is a convenient and reliable tool for monitoring labile PAHs, readily achieving quantitative detection of environmental levels (sub-ng and ng/L range) when coupled with conventional GC-MS or HPLC. ENVIRONMENTAL IMPLICATIONS: PAHs are carcinogenic and genotoxic compounds. They are environmentally ubiquitous and must be monitored in waters and other media. This study successfully developed a new DGT passive sampler for reliable in situ time-integrated measurements of PAHs in waters at the ng/L level. This is the first time to use passive samplers for accurate measurements of hydrophobic organic contaminants in aquatic systems without calibration, a big step forward in monitoring PAHs. The application of this new sampler will enhance our understanding of the sources, fate, behavior and ecotoxicology of PAHs, enabling improved environmental risk assessment and management of these compounds.


Assuntos
Monitoramento Ambiental , Hidrocarbonetos Policíclicos Aromáticos , Poluentes Químicos da Água , Poluentes Químicos da Água/análise , Hidrocarbonetos Policíclicos Aromáticos/análise , Monitoramento Ambiental/métodos , Monitoramento Ambiental/instrumentação , Difusão
18.
Se Pu ; 42(6): 508-523, 2024 Jun.
Artigo em Zh | MEDLINE | ID: mdl-38845512

RESUMO

Given continuous improvements in industrial production and living standards, the analysis and detection of complex biological sample systems has become increasingly important. Common complex biological samples include blood, serum, saliva, and urine. At present, the main methods used to separate and recognize target analytes in complex biological systems are electrophoresis, spectroscopy, and chromatography. However, because biological samples consist of complex components, they suffer from the matrix effect, which seriously affects the accuracy, sensitivity, and reliability of the selected separation analysis technique. In addition to the matrix effect, the detection of trace components is challenging because the content of the analyte in the sample is usually very low. Moreover, reasonable strategies for sample enrichment and signal amplification for easy analysis are lacking. In response to the various issues described above, researchers have focused their attention on immuno-affinity technology with the aim of achieving efficient sample separation based on the specific recognition effect between antigens and antibodies. Following a long period of development, this technology is now widely used in fields such as disease diagnosis, bioimaging, food testing, and recombinant protein purification. Common immuno-affinity technologies include solid-phase extraction (SPE) magnetic beads, affinity chromatography columns, and enzyme linked immunosorbent assay (ELISA) kits. Immuno-affinity techniques can successfully reduce or eliminate the matrix effect; however, their applications are limited by a number of disadvantages, such as high costs, tedious fabrication procedures, harsh operating conditions, and ligand leakage. Thus, developing an effective and reliable method that can address the matrix effect remains a challenging endeavor. Similar to the interactions between antigens and antibodies as well as enzymes and substrates, biomimetic molecularly imprinted polymers (MIPs) exhibit high specificity and affinity. Furthermore, compared with many other biomacromolecules such as antigens and aptamers, MIPs demonstrate higher stability, lower cost, and easier fabrication strategies, all of which are advantageous to their application. Therefore, molecular imprinting technology (MIT) is frequently used in SPE, chromatographic separation, and many other fields. With the development of MIT, researchers have engineered different types of imprinting strategies that can specifically extract the target analyte in complex biological samples while simultaneously avoiding the matrix effect. Some traditional separation technologies based on MIP technology have also been studied in depth; the most common of these technologies include stationary phases used for chromatography and adsorbents for SPE. Analytical methods that combine MIT with highly sensitive detection technologies have received wide interest in fields such as disease diagnosis and bioimaging. In this review, we highlight the new MIP strategies developed in recent years, and describe the applications of MIT-based separation analysis methods in fields including chromatographic separation, SPE, diagnosis, bioimaging, and proteomics. The drawbacks of these techniques as well as their future development prospects are also discussed.


Assuntos
Impressão Molecular , Humanos , Cromatografia de Afinidade/métodos , Extração em Fase Sólida/métodos , Ensaio de Imunoadsorção Enzimática
19.
Biotechnol Adv ; 71: 108318, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38266935

RESUMO

Molecularly imprinted polymers (MIPs), a type of biomimetic material, have attracted considerable interest owing to their cost-effectiveness, good physiochemical stability, favourable specificity and selectivity for target analytes, and widely used for various biological applications. It was demonstrated that MIPs with significant selectivity towards protein-based targets could be applied in medicine, diagnostics, proteomics, environmental analysis, sensors, various in vivo and/or in vitro applications, drug delivery systems, etc. This review provides an overview of MIPs dedicated to biomedical applications and insights into perspectives on the application of MIPs in newly emerging areas of biotechnology. Many different protocols applied for the synthesis of MIPs are overviewed in this review. The templates used for molecular imprinting vary from the minor glycosylated glycan-based structures, amino acids, and proteins to whole bacteria, which are also overviewed in this review. Economic, environmental, rapid preparation, stability, and reproducibility have been highlighted as significant advantages of MIPs. Particularly, some specialized MIPs, in addition to molecular recognition properties, can have high catalytic activity, which in some cases could be compared with other bio-catalytic systems. Therefore, such MIPs belong to the class of so-called 'artificial enzymes'. The discussion provided in this manuscript furnishes a comparative analysis of different approaches developed, underlining their relative advantages and disadvantages highlighting trends and possible future directions of MIP technology.


Assuntos
Impressão Molecular , Impressão Molecular/métodos , Reprodutibilidade dos Testes , Polímeros/química , Proteínas , Sistemas de Liberação de Medicamentos
20.
Biosens Bioelectron ; 251: 116043, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38368643

RESUMO

This article aims to present a comparative study of three polypyrrole-based molecularly imprinted polymer (MIP) systems for the detection of the recombinant severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) nucleocapsid protein (rN). The rN is known for its relatively low propensity to mutate compared to other SARS-CoV-2 antigens. The aforementioned systems include screen-printed carbon electrodes (SPCE) modified with gold nanostructures (MIP1), platinum nanostructures (MIP2), and the unmodified SPCE (MIP3), which was used for control. Pulsed amperometric detection (PAD) was employed as the detection technique, offering the advantage of label-free detection without the need for an additional redox probe. Calibration curves were constructed using the obtained data to evaluate the response of each system. Non-imprinted systems were also tested in parallel to evaluate the contribution of non-specific binding and assess the affinity sensor's efficiency. The analysis of calibration curves revealed that the AuNS-based MIP1 system exhibited the lowest contribution of non-specific binding and displayed a better fit with the chosen fitting model compared to the other systems. Further analysis of this system included determining the limit of detection (LOD) (51.2 ± 2.8 pg/mL), the limit of quantification (LOQ) (153.9 ± 8.3 pg/mL), and a specificity test using a recombinant receptor-binding domain of SARS-CoV-2 spike protein as a control. Based on the results, the AuNS-based MIP1 system demonstrated high specificity and sensitivity for the label-free detection of SARS-CoV-2 nucleocapsid protein. The utilization of PAD without the need for additional redox probes makes this sensing system convenient and valuable for rapid and accurate virus detection.


Assuntos
Técnicas Biossensoriais , COVID-19 , Glicoproteína da Espícula de Coronavírus , Humanos , SARS-CoV-2 , COVID-19/diagnóstico , Polímeros/química , Pirróis , Proteínas do Nucleocapsídeo/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA