Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 3.677
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
J Cardiovasc Electrophysiol ; 35(5): 1046-1049, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38468182

RESUMO

INTRODUCTION: Left atrial appendage (LAA) closure (LAAC) is considered a viable alternative to anticoagulation therapy for stroke prevention in nonvalvular atrial fibrillation, we report a case with a less common shunt resulting from a device-related coronary artery-appendage fistula (CAAF) following LAAC. METHODS AND RESULTS: A 67-year-old male with a history of LAAC was referred to our emergency room with recurrent chest pain and palpitations and was diagnosed with ischemic angina pectoris. Subsequent coronary angiography (CAG) revealed 70% in-stent restenosis and an abnormal shunt of contrast originating from the left circumflex artery (LCA) to the LAA tip which did not exist before. The restenosis was successfully dilated using a drug-coated balloon, the procedure was safely completed without pericardial effusion. The patient had been implanted with a LAmbre occluder (Lifetech Scientific Corp.) in the previous LAAC procedure. This occluder had a lobe-disk design, and the distal umbrella was not fully opened after release, particularly in the lower portion. This could make the hooks embedded on the umbrella contact the LAA wall more tightly, possibly resulting in microperforation and coincidental impingement of the LCA. The epicardial adipose and hyperplastic tissue then chronically wrapped the perforated site, prevented blood outflow into the epicardium, and ultimately formed a CAAF. CONCLUSION: CAAF is a rare complication after LAAC but may be underestimated, especially for lobe-disk designed occluders. Therefore, CAG is perhaps necessary to detect this complication.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Idoso , Humanos , Masculino , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/fisiopatologia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Vasos Coronários/diagnóstico por imagem , Oclusão do Apêndice Atrial Esquerdo , Desenho de Prótese , Dispositivo para Oclusão Septal/efeitos adversos , Resultado do Tratamento , Fístula Vascular/diagnóstico por imagem , Fístula Vascular/etiologia
2.
Catheter Cardiovasc Interv ; 103(5): 741-750, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38451154

RESUMO

BACKGROUND: The GCA is a well performing device in terms of efficacy despite complex anatomies (aortic rim <5 mm and ASD diameter >17 mm) with a good safety profile. AIMS: To evaluate atrial septal defect (ASD) features impacting on right disc device thrombosis in patients who underwent Gore Cardioform ASD Occluder (GCA) implantation. METHODS: A total of 44 consecutive patients undergoing percutaneous ASD with GCA device from January 2020 to September 2022 at our tertiary care Center were evaluated. The minimum follow-up was 6 months. RESULTS: The patients were stratified in two groups according to a cut-off value of ASD diameter equal to 20 mm at sizing balloon, derived from ROC analysis (AUC = 0.894; p = 0.024). Baseline characteristics were comparable between groups in terms of age, sex, weight, height, and interatrial septum dimensions. Patients with ASD > 20 mm (n = 9) had a higher ASD/device dimension ratio, both at echocardiography (p = 0.009) and at sizing balloon (p = 0.001), longer fluoroscopic time (p = 0.022), and higher incidence of device thrombosis (0.006). Right disc thrombosis was observed in three patients of the ASD > 20 mm group, always in the inferior portion of the right disc. On univariate analysis, ASD diameter at sizing balloon (OR 1.360; p = 0.036) was the only positive predictor of device thrombosis. CONCLUSIONS: Right disc thrombosis of the GCA device may be under-recognized at follow-up, hence deserving clinical attention, especially in those patients with larger ASD diameters.


Assuntos
Comunicação Interatrial , Dispositivo para Oclusão Septal , Humanos , Ecocardiografia Transesofagiana , Resultado do Tratamento , Cateterismo Cardíaco/efeitos adversos , Comunicação Interatrial/diagnóstico por imagem , Comunicação Interatrial/terapia
3.
Catheter Cardiovasc Interv ; 103(6): 934-942, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38584522

RESUMO

BACKGROUND: Transcatheter closure of the patent ductus arteriosus (PDA) in premature infants is currently dependent on fluoroscopic guidance and transportation to the catheterization laboratory. AIM: We describe a new echocardiographically guided technique to allow our team to move to the bedside at the neonatal intensive care unit (NICU) of the referring center for percutaneous treatment of PDA in premature infants. METHODS: This is a single-center, retrospective, primarily descriptive analysis. Clinical details about the procedure, its outcomes, and complications were collected. RESULTS: Fifty-eight neonates with a median weight of 1110 g (range 730-2800) and postnatal age of 28 days (range 9-95) underwent percutaneous PDA closure. Five of them were treated in our center with ultrasound guidance only and the other 53 in 18 different neonatology units in 12 towns. The median duration of the procedure was 40 min (range 20-195 min). There were no procedural deaths. There was one residual shunt for 3 weeks, in all other patients the duct closed completely in the first few hours after the intervention. In one patient the procedure had to be interrupted because of a pericardial effusion which had to be drained, the PDA was closed successfully interventionally 5 days later. One device-related aortic coarctation had to be stented. One embolization and one late migration occurred and required treatment. CONCLUSIONS: Echocardiographically guided transcatheter closure of the PDA in prematures was repeatedly possible and allowed that the procedure is performed at the bedside at the NICU with an acceptable rate of complications.


Assuntos
Cateterismo Cardíaco , Permeabilidade do Canal Arterial , Ultrassonografia de Intervenção , Humanos , Permeabilidade do Canal Arterial/terapia , Permeabilidade do Canal Arterial/diagnóstico por imagem , Permeabilidade do Canal Arterial/fisiopatologia , Recém-Nascido , Estudos Retrospectivos , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Resultado do Tratamento , Idade Gestacional , Valor Preditivo dos Testes , Masculino , Feminino , Fatores de Tempo , Índice de Gravidade de Doença , Recém-Nascido Prematuro , Lactente Extremamente Prematuro , Unidades de Terapia Intensiva Neonatal , Sistemas Automatizados de Assistência Junto ao Leito , Testes Imediatos , Dispositivo para Oclusão Septal , Lactente
4.
Circ J ; 88(5): 663-671, 2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38325819

RESUMO

BACKGROUND: Complications arising from transcatheter closure of perimembranous ventricular septal defects (pmVSD) in children, such as residual shunts and aortic regurgitation (AR), have been observed. However, the associated risk factors remain unclear. This study identified risk factors linked with residual shunts and AR following transcatheter closure of pmVSD in children aged 2-12 years.Methods and Results: The medical records of 63 children with pmVSD and a pulmonary-to-systemic blood flow ratio <2.0 who underwent transcatheter closure between 2011 and 2018 were analyzed with a minimum 3-year follow-up. The success rate of transcatheter closure was 98.4%, with no emergency surgery, permanent high-degree atrioventricular block, or mortality. Defects ≥4.5 mm had significantly higher odds of persistent residual shunt (odds ratio [OR] 6.85; P=0.03). The use of an oversize device (≥1.5 mm) showed a trend towards reducing residual shunts (OR 0.23; P=0.06). Age <4 years (OR 27.38; 95% confidence interval [CI] 2.33-321.68) and perimembranous outlet-type VSD (OR 11.94, 95% CI 1.10-129.81) were independent risk factors for AR progression after closure. CONCLUSIONS: Careful attention is crucial for pmVSDs ≥4.5 mm to prevent persistent residual shunts in transcatheter closure. Assessing AR risk, particularly in children aged <4 years, is essential while considering the benefits of pmVSD closure.


Assuntos
Cateterismo Cardíaco , Comunicação Interventricular , Humanos , Comunicação Interventricular/cirurgia , Pré-Escolar , Criança , Fatores de Risco , Masculino , Feminino , Cateterismo Cardíaco/efeitos adversos , Estudos Retrospectivos , Dispositivo para Oclusão Septal/efeitos adversos , Resultado do Tratamento , Insuficiência da Valva Aórtica/etiologia , Fatores Etários , Fatores de Tempo , Seguimentos , Complicações Pós-Operatórias/etiologia
5.
BMC Cardiovasc Disord ; 24(1): 59, 2024 Jan 18.
Artigo em Inglês | MEDLINE | ID: mdl-38238685

RESUMO

OBJECTIVE: To investigate the risk factors for thrombocytopenia after transcatheter occlusion operation of patent ductus arteriosus (PDA). METHOD: Retrospective analyses were conducted using clinical data from 106 patients with PDA who underwent transcatheter closure operations at Henan Provincial Chest Hospital, Zhengzhou University, from January 2018 to June 2022. The study compared the changes in platelet counts before and after the operation, and investigated the risk factors for thrombocytopenia following PDA closure in different groups and layers. RESULTS: The platelet count of patients with PDA significantly decreased after undergoing transcatheter PDA occlusion. Logistic regression analysis revealed that factors such as PDA diameter, occluder diameter, pressure difference on the two sides of the occluder, and residual shunt were associated with an increased risk of thrombocytopenia following PDA occlusion. Specifically, the size of the occluder and the pressure difference between the two sides of the occluder were found to have a negative correlation with the postoperative platelet count. Further subgroup analysis demonstrated that the incidence of total thrombocytopenia was significantly higher in the large PDA group compared to the small-medium PDA groups. CONCLUSION: Our findings suggest that occluder diameter, the pressure difference between the two sides of the occluder, and the residual shunt are major risk factors correlated with the incidence of postoperative thrombocytopenia. However, a multicenter and long-term prospective study is required to further evaluate the prognosis of PDA patients with thrombocytopenia after transcatheter occlusion.


Assuntos
Permeabilidade do Canal Arterial , Dispositivo para Oclusão Septal , Trombocitopenia , Humanos , Lactente , Cateterismo Cardíaco/efeitos adversos , Permeabilidade do Canal Arterial/diagnóstico por imagem , Permeabilidade do Canal Arterial/terapia , Contagem de Plaquetas , Estudos Retrospectivos , Fatores de Risco , Trombocitopenia/diagnóstico , Trombocitopenia/epidemiologia , Trombocitopenia/etiologia , Resultado do Tratamento
6.
Eur J Pediatr ; 183(5): 2193-2201, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38381375

RESUMO

Transcatheter patent ductus arteriosus (PDA) closure is a safe and effective alternative to surgical ligation in low-body-weight infants. Post-ligation cardiac syndrome (PLCS) is defined as severe hemodynamic and respiratory collapse within 24 h of PDA closure, requiring initiation or an increase of an inotropic agent by > 20% of preligation dosing and an absolute increase of at least 20% in ventilation parameters compared with the preoperative value. Whilst PLCS is routinely observed after surgery, its incidence remains poorly described following transcatheter closure. This study aimed to compare the incidence of PLCS after surgical versus transcatheter closure of PDA in low-body-weight premature infants. Propensity scores were used to compare surgical (N = 78) and transcatheter (N = 76) groups of preterm infants who underwent PDA closure at a procedural weight less than 2000 g in two tertiary institutions between 2009 and 2021. The primary outcome was the incidence of PLCS. Secondary outcomes included overall mortality before discharge, risk factors for PLCS, and post-procedural complications. Procedural success was 100% in both groups. After matching, transcatheter group experienced no PLCS vs 15% in the surgical group (p = 0.012). Furthermore, overall mortality (2% vs 17%; p = 0.03) and major complications (2% vs 23%; p = 0.002) were higher in the surgical group. Surgery (100% vs 47%; p < 0.01), gestation age (25 ± 1 vs 26 ± 2 weeks, p < 0.05) and inotropic support before closure (90% vs 29%; p < 0.001) were associated with PLCS occurrence.          Conclusion: Transcatheter PDA closure may be equally effective but safer than surgical PDA closure in low-body-weight premature infants. What is Known: • Post-ligation cardiac syndrome is a serious and common complication of surgical closure of the ductus arteriosus in preterm infants. • Transcatheter closure of preterm ductus arteriosus is a safe and effective technique that is becoming more and more common worldwide. What is New: • Device closure is safer than surgical ligation for patent ductus arteriosus closure in preterm infants and may be the first-line non-pharmacological therapeutic option in this indication in experienced teams. • Our findings should encourage neonatologists and pediatric cardiologists to start and/or strengthen a durable interventional program for transcatheter PDA closure in premature infants.


Assuntos
Cateterismo Cardíaco , Permeabilidade do Canal Arterial , Recém-Nascido Prematuro , Complicações Pós-Operatórias , Humanos , Permeabilidade do Canal Arterial/cirurgia , Estudos Retrospectivos , Recém-Nascido , Feminino , Ligadura/métodos , Ligadura/efeitos adversos , Masculino , Cateterismo Cardíaco/métodos , Cateterismo Cardíaco/efeitos adversos , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Recém-Nascido de Baixo Peso , Incidência , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/métodos , Síndrome , Pontuação de Propensão , Dispositivo para Oclusão Septal , Fatores de Risco , Doenças do Prematuro/cirurgia , Doenças do Prematuro/etiologia , Doenças do Prematuro/terapia , Doenças do Prematuro/epidemiologia
7.
Heart Vessels ; 39(6): 539-548, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38329512

RESUMO

For pre-procedural planning of left atrial appendage (LAA) closure, sizing is crucial. Although transesophageal echocardiography (TEE) is a standard modality, cardiac computed tomography (CT) is also widely used. The virtual TEE (V-TEE) that our group developed enables us to reconstruct images similar to TEE images from CT images. The software should be helpful to understand and plan the procedure strategy. Accordingly, we investigated the utility of V-TEE. Sixty-six patients at 4 participating sites who completed both CT and TEE prior to LAA closure were included. The LAA diameter at the landing zone (LZ) for WATCHMAN™ device implantation was statistically compared at 0°, 45°, 90°, and 135° between V-TEE and TEE. Among 66 cases, only 3 cases were excluded due to poor imaging quality, and 63 cases were analyzed. The device LZ diameters based on V-TEE were strongly correlated with those based on TEE, despite the significantly greater diameter based on V-TEE with mean differences of 2.4 to 3.0 mm (all of them: P < 0.001). The discordances (V-TEE/TEE ratio) at most angles were significantly larger in the elliptical LAAs. V-TEE provides a valuable method for the evaluation of the LAA diameters. V-TEE-based measurements were larger than conventional TEE-based measurements, especially in cases of elliptical LAAs. The assessment by V-TEE has the potential benefit of ensuring proper device sizing regardless of the LAA morphology.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Ecocardiografia Transesofagiana , Humanos , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Ecocardiografia Transesofagiana/métodos , Feminino , Masculino , Idoso , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Tomografia Computadorizada por Raios X/métodos , Idoso de 80 Anos ou mais , Estudos Retrospectivos , Cateterismo Cardíaco/métodos , Dispositivo para Oclusão Septal , Pessoa de Meia-Idade , Tomografia Computadorizada Multidetectores/métodos , Reprodutibilidade dos Testes
8.
Langenbecks Arch Surg ; 409(1): 169, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38822914

RESUMO

INTRODUCTION: Tracheoesophageal fistula (TEF) especially malignant TEF (mTEF) is an uncommon yet critical medical condition necessitating immediate intervention. This life-threatening condition frequently manifests in critically ill patients who are dependent on prolonged mechanical ventilation and are unsuitable candidates for thoracotomy due to their compromised health status. The Management of these mTEF patients remain a significant challenge.This study aimed to evaluate the safety and efficacy of using a cardiac septal occluder for the closure of mTEF. METHODS: 8 patients with mTEF underwent closure surgery using atrial/ventricular septal defect (ASD/VSD) septal occluders at the Respiratory Department of HuBei Yichang Central People's Hospital from 2021 to 2023. The procedure involved percutaneous placement of the occluder through the fistula to achieve closure. RESULTS: The placement of the cardiac septal occluder was successfully achieved with ease and efficiency in all patients. The study demonstrated that the use of cardiac septal occluder therapy in patients with mTEF can alleviate symptoms, improve quality of life, and enhance survival rates, with no significant complications observed. Furthermore, the study provided comprehensive details on surgical indications, preoperative evaluation and diagnosis, selection of occluder, methods of occlusion, and postoperative care. CONCLUSIONS: The application of cardiac septal occluder in the treatment of mTEF is a safe and effective palliative treatment. This approach may be particularly beneficial for patients with a high risk of complications and mortality associated with traditional surgical interventions.


Assuntos
Cuidados Paliativos , Dispositivo para Oclusão Septal , Fístula Traqueoesofágica , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Cuidados Paliativos/métodos , Qualidade de Vida , Estudos Retrospectivos , Fístula Traqueoesofágica/cirurgia , Fístula Traqueoesofágica/etiologia , Resultado do Tratamento
9.
Acta Paediatr ; 113(4): 812-817, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38149770

RESUMO

AIM: To describe our initial experience with the indications and results of the 5/7 Occlutech® duct Occluder (ODO, Occlutech International AB, Helsingborg, Sweden). A small incremental increase in occluder sizes is of utmost importance for successful outcomes, especially in smaller patients in whom protrusion of the distal disk towards the aorta should be minimised. METHODS: Retrospective study of all patients undergoing PDA closure with the 5/7 ODO in three institutions since 2018. RESULTS: The 5/7 ODO was used in 18 patients with median age and weight at the time of the procedure of 17.5 months (interquartile range 25th to 75th percentile 8 months- 4.4 years) and 13.6 kg (interquartile range 25th to 75th percentile 6.4-22.5 kg) respectively. All cases were successful. There were no cases of device embolisation, haemolysis, or flow disturbance of the LPA or the aorta. CONCLUSIONS: This small retrospective study demonstrated an excellent outcome of transcatheter PDA closure with the 5/7 ODO. The device is a beneficial complement to the existing sizes of PDA devices, filling the gap between the 4/6 and 6/8 ODO and avoiding protrusion of a larger disk in the aortic isthmus.


Assuntos
Permeabilidade do Canal Arterial , Dispositivo para Oclusão Septal , Humanos , Pré-Escolar , Estudos Retrospectivos , Resultado do Tratamento , Desenho de Prótese , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/métodos
10.
Echocardiography ; 41(6): e15822, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38853621

RESUMO

BACKGROUND: Balloon sizing (BS) has been used for device size selection in percutaneous atrial septal defect (ASD) closure. Due to its limitations, alternative imaging techniques like three-dimensional transesophageal echocardiography (3D-TEE) are valuable for guiding ASD device size selection during ASD closure procedures. The purpose of this study was to compare ASD sizing using measurements obtained from 3D-TEE to those utilizing the standard balloon sizing method. METHODS: We identified 53 patients with single secundum type ASD without PFO who underwent percutaneous closure at the Tehran Heart Center between 2019 and 2022. Balloon sizing was performed in all patients with the stop-flow technique, and the choice of device size was determined based on the sizing derived from BS. 3D-TEE imaging was performed before the intervention, and the ASD shape and quality of ASD rims were assessed. RESULTS: Among the 53 patients who underwent single ASD device closure, multiple 3D TEE measurements significantly correlated with balloon sizing results. This included defect area, perimeter, and diameter obtained from 3D-TEE images multi-planar reconstruction. ASD perimeter detected by 3D TEE had the best correlation with BS results. When divided by the shape of ASD, there was no significant difference between our 3D-images data and BS in round or oval-shaped ASDs. CONCLUSION: The 3D-TEE study is reliable for assessing ASD configurational characteristics in percutaneous device closure candidates. 3D-TEE has the potential to accurately determine the appropriate device size and reduce complications, costs, and procedural duration. Further research is needed to validate these findings and establish the role of 3D-TEE measurements in guiding the best treatment decisions for ASD closure.


Assuntos
Ecocardiografia Tridimensional , Ecocardiografia Transesofagiana , Comunicação Interatrial , Dispositivo para Oclusão Septal , Humanos , Ecocardiografia Transesofagiana/métodos , Ecocardiografia Tridimensional/métodos , Masculino , Comunicação Interatrial/cirurgia , Comunicação Interatrial/diagnóstico por imagem , Feminino , Adulto , Pessoa de Meia-Idade , Adolescente , Desenho de Prótese , Cateterismo Cardíaco/métodos , Reprodutibilidade dos Testes , Adulto Jovem
11.
Pediatr Cardiol ; 45(1): 121-132, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38103070

RESUMO

KONAR-MFO (multifunctional occluder) [Lifetech, Shenzhen, China] was first used in humans in 2013 and received the CE mark in May 2018. As name suggest, it can be use in various(multifunctional) situations in paediatric as well as adults. This is a versatile device with an improved delivery and flexibility which make this device a better option to be use with more comfort and minimum complications. This paper is regarding few rare and complicated lesions, like anomalous origin of coronary artery from pulmonary artery (ALCAPA) device closure, device closure of ventricular septal rupture (VSR) post myocardial infarction in sick elderly and finally device closure of paravalvar leak (PVL)after mitral valve replacement which were treated with this device with excellent results. This study is a retrospective review from a tertiary level dedicated cardiac referral centre in south India. Three cases we are reporting here in which Konar-multifunctional occluders were used in locations other than commoner and regular defects like patent ductus arteriosus, ventricular septal defect etc, over the span of one year between April 2022 and March 2023. Pre-procedure, all patients underwent detailed clinical evaluation followed by transthoracic echocardiography, 12-lead electrocardiogram, and Chest X-ray at the outpatient department. All patients were either symptomatic or had a hemodynamically significant lesion on echocardiography. The decision for transcatheter management was taken after discussing with surgical team in view of either high risk surgery or refusal from patients for surgical options. All patients were followed up post procedure at regular intervals with transthoracic echocardiograms and 12-lead electrocardiograms for a minimum period of 6 months. All these three cases mentioned in our study underwent a complete closure of their respective lesions with no evidence of residual shunt. None of these patients had any major complications, prolonged stay, or any vascular injuries. All patients completed minimum 6-month follow-up and were doing well without any residual flows. First case of ALCAPA, after procedure showed improvement in IVCD, QTc duration and also no significant ischemic changes were noted. Myocardial perfusion scintigraphy was done after 6 months of procedure which showed improvement in contractile function and perfusion of left ventricle. Second case of VSR device closure patient showed immediate significant symptomatic improvement. He was transferred to the coronary care unit, and discharged seven days later. As of now the patient is alive and feeling well with no residual shunt detected by transthoracic echocardiography. No procedure -related complications have been recorded during last two years. Third case of PVL device closure had uneventful recovery from anaesthesia. Prosthetic valve functioned normally during the 5 days of post-procedure hospitalization. The transthoracic 2D- echocardiography performed during follow-up at the end of one month showed no mitral PVL.During follow-up after 1 year, the patient improved symptomatically. Normal prosthetic valve function and no leakage documented on transthoracic echocardiography. Konar-MFO emerging as an important occluder with interesting attributes which makes it a very useful asset to have in catheterizations laboratory.


Assuntos
Síndrome de Bland-White-Garland , Dispositivo para Oclusão Septal , Humanos , Masculino , Cateterismo Cardíaco/métodos , Ecocardiografia , Resultado do Tratamento
12.
Pediatr Cardiol ; 45(1): 175-183, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38081968

RESUMO

Transcatheter closure of VSD remains a complex procedure in infants with technical challenges and carries the risk of significant complications, due to its complex anatomical morphology and closed proximity to the atrioventricular valves and the conduction system. In this article, we presented transcatheter VSD closure in infants under 10 kg using the Lifetech Konar-MF device via only venous route without TEE guidance and arterial access. Between January 2021 and May 2023, a total of 34 patients weighing less than 10 kg who underwent transcatheter VSD closure antegradely with Lifetech™ Konar-Multifunctional (MF) occluder were included in the study. The mean age of the patients was 8.1 (3.5-35) months. Average weight was 6.5 kg (range 4.5-10 kg). VSD was perimembranous in 27 patients (79.4%). Successful device placement was achieved in all 34 patients. However, device embolization occurred in three patients. One of the patients was successfully implanted with a one size larger device, the surgical closure was performed other two cases. TR occurred in seven patients (20.6%) after releasing devices. None of the patients developed complete heart block. Right bundle branch block developed in two patients. Residual shunt was observed in 9 patients (six small, two moderate, and one large). During follow-up, residual shunt disappeared in six of these patients and only mild residual shunt remained in the other four patients which have not required any further intervention. Transcatheter closure of VSD with Lifetech Konar-MF device is safe and effective in infants less than 10 kg via only venous access with a high success rate and low complication rate. In these patients, transcatheter VSD closure can be performed by excluding the risk of complications that may occur due to AV loop formation, arterial intervention, endotracheal intubation and TEE use.


Assuntos
Bloqueio Atrioventricular , Comunicação Interventricular , Dispositivo para Oclusão Septal , Lactente , Humanos , Cateterismo Cardíaco/métodos , Próteses e Implantes , Sistema de Condução Cardíaco , Comunicação Interventricular/cirurgia , Bloqueio Atrioventricular/etiologia , Resultado do Tratamento
13.
Pediatr Cardiol ; 45(2): 272-281, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38194099

RESUMO

The experience with percutaneous closure of postoperative residual ventricular septal defects (VSDs) is expanding with improved device technology and techniques. To report our experience with percutaneous closure of residual VSDs after cardiac surgeries. Retrospective clinical data review of patients who had percutaneous closure of postoperative residual VSDs at our institution between 2010 and 2022. Patients' demographics, procedural, and follow-up data were looked at. Twelve patients (50% males) with a median age of 9.2 years (range 0.9-22) were identified. Baseline surgeries were 8 tetralogy of Fallot corrections, 2 pulmonary bandings for large muscular VSD (mVSD) including 1 coarctation repair, 1 atrioventricular septal defect repair, 1 sub-aortic membrane resection-induced iatrogenic VSD, 1 isolated VSD closure, and 1 additional mVSD. Median duration between baseline surgery and percutaneous VSD closure was 2.2 years (range 0.2-8.3). Residual VSD shunting was secondary to surgical patch leakage in 8/12 patients. The median angiographic defect diameter was 6.8 mm (range 4.8-14). The defect was balloon-calibrated in 3/12 patients. Defects were tackled retrogradely in 3/9 patients. Amplatzer Membranous VSD occluder (n = 1), Lifetech Multifunctional (n = 5), Membranous (n = 1) and muscular VSD occluders (n = 2) and Occlutech Membranous (n = 1) and Muscular (n = 2) VSD occluders were used. The procedure was successful in 10/12 patients. Two devices embolized to the pulmonary artery and were snare-retrieved. Both patients were referred for surgery. The median follow-up was 1.3 years (range 0.1-12). Six-month ultrasound showed one trivial residual shunt and one mild right ventricular outflow obstruction. One patient is receiving targeted therapy for pulmonary hypertension at 2 years of follow-up. Transcatheter closure of postoperative residual VSDs is a feasible yet challenging intervention. Procedural complications can be encountered.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Comunicação Interventricular , Dispositivo para Oclusão Septal , Masculino , Humanos , Lactente , Pré-Escolar , Criança , Adolescente , Adulto Jovem , Adulto , Feminino , Estudos Retrospectivos , Resultado do Tratamento , Cateterismo Cardíaco/métodos , Comunicação Interventricular/diagnóstico por imagem , Comunicação Interventricular/cirurgia , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/métodos , Dispositivo para Oclusão Septal/efeitos adversos
14.
Pediatr Cardiol ; 45(2): 410-415, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37803227

RESUMO

To assess the safety and effectiveness of utilizing eccentric occlusion for the treatment of sub-arterial ventricular septal defects, we performed a retrospective study on the classification and analysis of relevant cases. A total of 105 patients with a minimally invasive incision were enrolled in this study, from April 2018 to September 2022. All patients underwent treatment of transthoracic sub-arterial ventricular septal defect occlusion. We analyzed the causes of closure failure, indication, and complication. Briefly, the closure device was successfully implanted in 78 cases (74.2%) with a mean age of 31.4 ± 31.8 months, VSD size of 4.3 ± 0.9 mm, and device size of 6.0 ± 1.1 mm. However, 27 cases (25.8%) required cardiopulmonary bypass due to failure of occlusion. The reasons for failure included 13 cases with worsened aortic regurgitation, two cases with worsened aortic valve prolapse, one case with worsened mitral regurgitation, eight cases with significant residual shunt, and three cases with deviated occlusion morphology. During the 1-36-month follow-up visit, no cases experienced displacement of the eccentric umbrella, shedding, or arrhythmia. All residual shunts resolved during the visit. We concluded that occlusion for sub-arterial VSD has sufficient security and feasibility, under the strict control of surgical indications, appropriate choice of occluder and precise perioperative management.


Assuntos
Comunicação Interventricular , Dispositivo para Oclusão Septal , Doenças Vasculares , Humanos , Lactente , Pré-Escolar , Resultado do Tratamento , Estudos Retrospectivos , Cateterismo Cardíaco , Comunicação Interventricular/diagnóstico por imagem , Comunicação Interventricular/cirurgia , Ponte Cardiopulmonar
15.
Eur Heart J ; 44(36): 3469-3477, 2023 09 21.
Artigo em Inglês | MEDLINE | ID: mdl-37279491

RESUMO

AIMS: Transcatheter closure of patent foramen ovale (PFO) is the recommended stroke prevention treatment in patients ≤60 years with cryptogenic ischemic stroke and PFO. Atrial fibrillation or flutter (AF) is a known potential procedure-related complication, but long-term risk of developing AF remains unknown. This paper studied the long-term risk of developing AF following PFO closure. METHODS AND RESULTS: A Danish nationwide cohort study was conducted. During 2008-2020, this study identified a PFO closure cohort, a PFO diagnosis cohort without PFO closure, and a general population comparison cohort matched 10:1 to the PFO closure cohort on age and sex. The outcome was first-time AF diagnosis. Risk of AF and multivariable-adjusted hazard ratio (HR) of the association between PFO closure or PFO diagnosis and AF were calculated. A total of 817 patients with PFO closure, 1224 with PFO diagnosis, and 8170 matched individuals were identified. The 5 year risk of AF was 7.8% [95% confidence interval (CI): 5.5-10] in the PFO closure cohort, 3.1% (95% CI: 2.0-4.2) in the PFO diagnosis cohort, and 1.2% (95% CI: 0.8-1.6) in the matched cohort. The HR of AF comparing PFO closure with PFO diagnosis was 2.3 (95% CI: 1.3-4.0) within the first 3 months and 0.7 (95% CI: 0.3-1.7) thereafter. The HR of AF comparing PFO closure with the matched cohort was 51 (95% CI: 21-125) within the first 3 months and 2.5 (95% CI: 1.2-5.0) thereafter. CONCLUSION: Patent foramen ovale closure was not associated with any substantial increased long-term risk of developing AF beyond the well-known procedure-related short-term risk.


Assuntos
Fibrilação Atrial , Forame Oval Patente , Dispositivo para Oclusão Septal , Acidente Vascular Cerebral , Humanos , Fibrilação Atrial/etiologia , Fibrilação Atrial/complicações , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/diagnóstico , Forame Oval Patente/complicações , Forame Oval Patente/epidemiologia , Forame Oval Patente/diagnóstico , Estudos de Coortes , Prevenção Secundária/métodos , Cateterismo Cardíaco/efeitos adversos , Dinamarca/epidemiologia , Resultado do Tratamento , Recidiva , Dispositivo para Oclusão Septal/efeitos adversos
16.
Heart Surg Forum ; 27(1): E006-E013, 2024 Jan 09.
Artigo em Inglês | MEDLINE | ID: mdl-38286647

RESUMO

Primary heart tumors are rare, with atrial myxomas being the most common type. Atrial myxomas can lead to embolisms, heart obstruction, and systemic symptoms. Herein, we report a case of 72-year-old woman who presented with a left atrial myxoma at the atrial septal defect occluder, a new acute cerebral infarction, and MINOCA (myocardial infarction with no obstructive coronary atherosclerosis). Left atrial myxoma is a common primary cardiac tumor; however, left atrial myxomas arising after percutaneous atrial septal defect occlusion are rare. Additionally, the patient presented with a new case of multiple systemic emboli. The patient underwent surgical resection of a left atrial myxoma, occluder, and left atrium, and atrial septal repair, and was discharged with good recovery for outpatient follow-up. The possibility of a cardiac tumor, especially an atrial myxoma, which can lead to a series of complications, should be considered at the closure site after percutaneous atrial septal closure. Therefore, active surgical treatment and long-term follow-up are warranted in such cases.


Assuntos
Embolia , Neoplasias Cardíacas , Comunicação Interatrial , Embolia Intracraniana , Mixoma , Dispositivo para Oclusão Septal , Feminino , Humanos , Idoso , Dispositivo para Oclusão Septal/efeitos adversos , Embolia Intracraniana/diagnóstico , Embolia Intracraniana/etiologia , Embolia Intracraniana/cirurgia , MINOCA , Comunicação Interatrial/complicações , Comunicação Interatrial/diagnóstico , Comunicação Interatrial/cirurgia , Embolia/diagnóstico , Embolia/etiologia , Embolia/cirurgia , Átrios do Coração/cirurgia , Neoplasias Cardíacas/complicações , Neoplasias Cardíacas/diagnóstico , Neoplasias Cardíacas/cirurgia , Mixoma/complicações , Mixoma/diagnóstico , Mixoma/cirurgia , Cateterismo Cardíaco/efeitos adversos
17.
Cardiol Young ; 34(3): 643-646, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37694546

RESUMO

INTRODUCTION: The goal of this single-centre study was to evaluate long-term results of percutaneous closure of secundum-type atrial septal defect using Amplatzer Septal Occluder with the follow-up to 25 years. METHODS: A retrospective analysis of patients who underwent percutaneous closure of secundum-type atrial septal defect between September 1995 and October 2012 in our institution was performed. All procedures were performed after fulfilling strict indication criteria. More than 5 years follow-up was reached in 651/803 patients (81%) with median follow-up time of 12 (5-25) years. RESULTS: The mean stretched defect diameter was 14,0 ± 5,2 mm. Early reintervention due to moderate or severe residual atrial septal defect had to be performed in 3/803 patients (0,03%). The incidence of long-term moderate or severe residual atrial septal defect was 0,0%. The complete closure rate at 10-year follow-up was 98,5%, as trivial residual shunts persisted in 8/508 patients (1,5%). A significant rate of the echocardiographic right ventricular end-diastolic diameter post-procedural normalisation (p < 0,05) was encountered. The rate of major complications was 0,5%. One device embolisation, one thrombus formation at the occluder surface, and one cardiac erosion in periprocedural or short post-procedural course were experienced. Only one late complication of infective endocarditis at the region of implanted occluder and the aortic valve was detected. The survival rate of all followed patients was 100%. CONCLUSIONS: Percutaneous closure of secundum-type atrial septal defect using Amplatzer Septal Occluder is a safe and effective procedure accounting for a very low incidence of major complications in the long-term follow-up.


Assuntos
Comunicação Interatrial , Dispositivo para Oclusão Septal , Humanos , Seguimentos , Estudos Retrospectivos , Comunicação Interatrial/cirurgia
18.
Cardiol Young ; 34(2): 455-458, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38167420

RESUMO

We report on a 6-month-old infant (6 Kg/ 64 cm) with perimembranous ventricular septal defect (absent sub-aortic rim, 10 mm left ventricular entry, and 4 and 6 mm right ventricular exists) and successful retrograde closure using an 8x6 mm KONAR-MF™ VSD occluder (Lifetech, China). Immediate and 48 hours post-procedure ultrasounds showed an accurately positioned device and two jets of mild-to-moderate residual shunts. At the 2-week follow-up, the device did not change position and the shunt was stable and intra-prosthetic. The scheduled 3-month follow-up was skipped for familial reasons. The patient came back without alarming symptoms for the regular 6-month follow-up, and the device was found embolised to the left pulmonary artery. The device was retrieved surgically, and the defect was patch-closed with excellent outcomes. There was a pseudoaneurysm involving the tricuspid valve chordae and the device was endothelialized partially on one edge suggesting that embolization occurred somewhere between 3 months and 6 months post-operative. Defects with compromised anatomies should be closed surgically to avoid suboptimal results, especially in small infants.


Assuntos
Embolização Terapêutica , Comunicação Interventricular , Dispositivo para Oclusão Septal , Lactente , Humanos , Cateterismo Cardíaco/métodos , Ecocardiografia , Embolização Terapêutica/efeitos adversos , Valva Tricúspide , Comunicação Interventricular/diagnóstico , Dispositivo para Oclusão Septal/efeitos adversos , Resultado do Tratamento
19.
Cardiol Young ; 34(1): 157-162, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37283091

RESUMO

In this multi-centre study, the mid- to long-term efficacy and safety of the Amplatzer Piccolo Occluder in patent ductus arteriosus closure in premature and term infants as well as children were discussed. Methods. Between 2016 and 2021, 645 patients, 152 of whom were less than 1 month old, underwent ductus closure with the Piccolo device from five different centres in Turkey. The median age of the patients was 2.2 years, and the mean narrowest point of duct diameter was 1.8 mm. Sixty-two patients weighed ≤ 1.5 kg, 90 patients 1.5-3 kg, and the mean follow-up was 20.4 months. In 396, the duct was closed by the retrograde route. Ductal anatomy was Type A in 285, C in 72, E in 171, and F in 64 patients. Fluoroscopy duration was 6.2 min. The procedure success rate was 99.1%. Device embolisation occurred in 13 patients (2%), and 11 were retrieved with a snare. Cardiac perforation and death developed in one premature baby. The left pulmonary artery and the descending aorta stenosis were observed in 3 (0.4%) and in 5 patients (0.5%). Results. Piccolo device is safe and effective in closing ductus in all age groups. It has low profile for use in premature and newborn babies, a small embolisation risk, and a low residual shunt rate after closure. Conclusion. The Piccolo device can be considered as close an ideal occluder. The lower profile, smaller delivery catheter size, and symmetry of this device allow for a venous or arterial approach.


Assuntos
Permeabilidade do Canal Arterial , Nascimento Prematuro , Dispositivo para Oclusão Septal , Criança , Lactente , Recém-Nascido , Feminino , Humanos , Adolescente , Pré-Escolar , Resultado do Tratamento , Permeabilidade do Canal Arterial/cirurgia , Cateterismo Cardíaco/métodos , Recém-Nascido Prematuro
20.
Cardiol Young ; 34(1): 228-231, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38073568

RESUMO

Amplatzer Vascular Plug IV (Abbott, USA) is usually used for the occlusion of abnormal tortuous vessels and has not been tried for the transcatheter closure of perimembranous ventricular septal defects with wind-sock morphology. Here, we report on three successful cases of perimembranous ventricular septal defect transcatheter closure using Amplatzer Vascular Plug IV. We did not observe residual shunting or new onset of complications during follow up. These preliminary positive results advocate the application and suitability of Amplatzer Vascular Plug IV for closing wind-sock-like perimembranous ventricular septal defects.


Assuntos
Comunicação Interventricular , Dispositivo para Oclusão Septal , Humanos , Seguimentos , Resultado do Tratamento , Vento , Cateterismo Cardíaco/métodos , Comunicação Interventricular/diagnóstico por imagem , Comunicação Interventricular/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA