Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 8.014
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
Magn Reson Med ; 91(6): 2612-2620, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38247037

RESUMO

PURPOSE: Measure the changes in relative lung water density (rLWD), lung volume, and total lung water content as a function of time after supine body positioning. METHODS: An efficient ultrashort-TE pulse sequence with a yarnball k-space trajectory was used to measure water density-weighted lung images for 25 min following supine body positioning (free breathing, 74-s acquisitions, 3D images at functional residual capacity, 18 time points) in 9 healthy volunteers. Global and regional (10 chest-to-back positions) rLWD, lung volume, and total lung water volume were measured in all subjects at all time points. Volume changes were validated with a nitrogen washout study in 3 participants. RESULTS: Global rLWD increased significantly (p = 0.001) from 31.8 ± 5.5% to 34.8 ± 6.8%, while lung volumes decreased significantly (p < 0.001) from 2390 ± 620 mL to 2130 ± 630 mL over the same 25-min interval. Total lung water volume decreased slightly from 730 ± 125 mL to 706 ± 126 mL (p = 0.028). There was a significant chest-to-back gradient in rLWD (20.7 ± 4.6% to 39.9 ± 6.1%) at all time points with absolute increases of 1.8 ± 1.2% at the chest and 5.4 ± 1.9% at the back. Nitrogen washout studies yielded a similar reduction in lung volume (12.5 ± 0.9%) and time course following supine positioning. CONCLUSION: Lung volumes during tidal breathing decrease significantly over tens of minutes following supine body positioning, with corresponding increases in lung water density (9.2 ± 4.4% relative increase). The total volume of lung water is slightly reduced over this interval (3.3 ± 4.0% relative change). Evaluation of rLWD should take time after supine positioning, and more generally, all sources of lung volume changes should be taken into consideration to avoid significant bias.


Assuntos
Pulmão , Posicionamento do Paciente , Humanos , Pulmão/diagnóstico por imagem , Medidas de Volume Pulmonar , Respiração , Nitrogênio , Decúbito Dorsal
2.
Strahlenther Onkol ; 200(1): 60-70, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37971534

RESUMO

PURPOSE: The objective of this work is to estimate the patient positioning accuracy of a surface-guided radiation therapy (SGRT) system using an optical surface scanner compared to an X­ray-based imaging system (IGRT) with respect to their impact on intracranial stereotactic radiotherapy (SRT) and intracranial stereotactic radiosurgery (SRS). METHODS: Patient positioning data, both acquired with SGRT and IGRT systems at the same linacs, serve as a basis for determination of positioning accuracy. A total of 35 patients with two different open face masks (578 datasets) were positioned using X­ray stereoscopic imaging and the patient position inside the open face mask was recorded using SGRT. The measurement accuracy of the SGRT system (in a "standard" and an SRS mode with higher resolution) was evaluated using both IGRT and SGRT patient positioning datasets taking into account the measurement errors of the X­ray system. Based on these clinically measured datasets, the positioning accuracy was estimated using Monte Carlo (MC) simulations. The relevant evaluation criterion, as standard of practice in cranial SRT, was the 95th percentile. RESULTS: The interfractional measurement displacement vector of the SGRT system, σSGRT, in high resolution mode was estimated at 2.5 mm (68th percentile) and 5 mm (95th percentile). If the standard resolution was used, σSGRT increased by about 20%. The standard deviation of the axis-related σSGRT of the SGRT system ranged between 1.5 and 1.8 mm interfractionally and 0.5 and 1.0 mm intrafractionally. The magnitude of σSGRT is mainly due to the principle of patient surface scanning and not due to technical limitations or vendor-specific issues in software or hardware. Based on the resulting σSGRT, MC simulations served as a measure for the positioning accuracy for non-coplanar couch rotations. If an SGRT system is used as the only patient positioning device in non-coplanar fields, interfractional positioning errors of up to 6 mm and intrafractional errors of up to 5 mm cannot be ruled out. In contrast, MC simulations resulted in a positioning error of 1.6 mm (95th percentile) using the IGRT system. The cause of positioning errors in the SGRT system is mainly a change in the facial surface relative to a defined point in the brain. CONCLUSION: In order to achieve the necessary geometric accuracy in cranial stereotactic radiotherapy, use of an X­ray-based IGRT system, especially when treating with non-coplanar couch angles, is highly recommended.


Assuntos
Radiocirurgia , Radioterapia Guiada por Imagem , Humanos , Posicionamento do Paciente/métodos , Raios X , Radiografia , Radioterapia Guiada por Imagem/métodos , Imageamento Tridimensional/métodos , Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Erros de Configuração em Radioterapia/prevenção & controle
3.
World J Urol ; 42(1): 308, 2024 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-38722376

RESUMO

PURPOSE: Residual fragments not removed with urinary stone surgery may become symptomatic. In this context, this study was carried out to investigate the effect of performing retrograde intrarenal surgery, which is conventionally performed in the lithotomy position, in the modified lithotomy position (Trend-side) on stone-free rates following the surgery. METHODS: This prospective study consisted of 100 patients with a single kidney stone smaller than 2 cm between 2021 and 2023. These patients were randomized into two groups of 50 patients each to be operated on in the conventional lithotomy and Trend-side positions. Variables were compared using independent t test for continuous variables and chi-square test for categorical variables. RESULTS: There was no significant difference between the lithotomy and Trend-side position groups in terms of preoperative size, density, location of the stone, and hydronephrosis degree. Stone-free rate was 72% (n = 36) in the lithotomy group and 92% (n = 46) in the Trend-side group. Hence, there was a significant difference between the groups in the stone-free rate in favor of the Trend-side group (p = 0.009). Fragmentation time was statistically significantly shorter in the Trend-side group than in the lithotomy group (34 ± 17 min vs. 43 ± 14 min; p = 0.006). There was no significant difference between the groups in postoperative complication rates. CONCLUSION: Performing retrograde intrarenal surgery in the Trend-side position shortened the duration of fragmentation compared to the lithotomy position and was associated with higher stone-free rates. In conclusion, the Trend-side position can be safely preferred in patients undergoing retrograde intrarenal surgery due to kidney stones.


Assuntos
Cálculos Renais , Posicionamento do Paciente , Humanos , Cálculos Renais/cirurgia , Estudos Prospectivos , Masculino , Feminino , Pessoa de Meia-Idade , Posicionamento do Paciente/métodos , Adulto , Procedimentos Cirúrgicos Urológicos/métodos , Idoso , Resultado do Tratamento
4.
Neuroradiology ; 66(6): 963-971, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38613702

RESUMO

PURPOSE: Few studies have investigated the influence of posture on the external jugular and diploic venous systems in the head and cranial region. In this study, we aimed to investigate the effects of posture on these systems using upright computed tomography (CT) scanning. METHODS: This study retrospectively analysed an upright CT dataset from a previous prospective study. In each patient, the diameters of the vessels in three external jugular tributaries and four diploic veins were measured using CT digital subtraction venography in both supine and sitting positions. RESULTS: Amongst the 20 cases in the original dataset, we eventually investigated 19 cases due to motion artifacts in 1 case. Compared with the supine position, most of the external jugular tributaries collapsed, and the average size significantly decreased in the sitting position (decreased by 22-49% on average). In contrast, most of the diploic veins, except the occipital diploic veins, tended to increase or remain unchanged (increased by 12-101% on average) in size in the sitting position compared with the supine position. However, the changes in the veins associated with this positional shift were not uniform; in approximately 5-30% of the cases, depending on each vein, an opposite trend was observed. CONCLUSION: Compared to the supine position, the contribution of external jugular tributaries to head venous drainage decreased in the sitting position, whilst most diploic veins maintained their contribution. These results could enhance our understanding of the physiology and pathophysiology of the head region in upright and sitting positions.


Assuntos
Angiografia Digital , Veias Jugulares , Humanos , Feminino , Masculino , Veias Jugulares/diagnóstico por imagem , Estudos Retrospectivos , Pessoa de Meia-Idade , Idoso , Angiografia Digital/métodos , Adulto , Posicionamento do Paciente/métodos , Postura Sentada , Decúbito Dorsal , Veias Cerebrais/diagnóstico por imagem , Postura/fisiologia , Idoso de 80 Anos ou mais , Tomografia Computadorizada por Raios X/métodos , Angiografia por Tomografia Computadorizada/métodos
5.
J Intensive Care Med ; 39(6): 567-576, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38105604

RESUMO

Background & Aims: This study aims to assess the application value of the real-time camera image-guided nasoenteric tube placement in critically ill COVID-19 patients undergoing endotracheal intubation and prone position ventilation therapy. Methods: We enrolled 116 COVID-19 patients receiving endotracheal intubation and prone position ventilation therapy in the intensive care unit (ICU). Patients were randomly divided into the real-time camera image-guided nasoenteric tube placement (n = 58) and bedside blind insertion (n = 58) groups. The success rate, placement time, complications, cost, heart rate, respiratory rate, Glasgow Coma Scale (GCS), and Acute Physiology and Chronic Health Evaluation II (APACHE-II) scores were compared between the 2 groups. Results: For ICU patients with COVID-19 undergoing prone position ventilation therapy, the success rate and cost were significantly higher in the real-time camera image-guided group compared to the bedside blind group (P < .05). The placement time and complication incidence were significantly lower in the real-time camera image-guided group (P < .05). The differences in heart rate, respiratory rate, GCS scores, and APACHE-II scores were insignificant (P > .05). Conclusions: The real-time camera image-guided nasoenteric tube placement system had advantages for ICU COVID-19 patients undergoing prone position ventilation therapy, including a high success rate, short placement time, and no impact on patient position during tube placement. Real-time camera image-guided nasoenteric tube placement can be performed in any position, and demonstrates high efficiency, safety, and accuracy.


Assuntos
COVID-19 , Unidades de Terapia Intensiva , Intubação Intratraqueal , Humanos , COVID-19/terapia , Masculino , Feminino , Pessoa de Meia-Idade , Decúbito Ventral , Idoso , Intubação Intratraqueal/métodos , SARS-CoV-2 , Respiração Artificial/métodos , Intubação Gastrointestinal/métodos , Adulto , Posicionamento do Paciente/métodos , Estado Terminal/terapia , APACHE , Cuidados Críticos/métodos
6.
Ear Hear ; 45(4): 1033-1044, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38439150

RESUMO

OBJECTIVES: Canalith repositioning procedures to treat benign paroxysmal positional vertigo are often applied following standardized criteria, without considering the possible anatomical singularities of the membranous labyrinth for each individual. As a result, certain patients may become refractory to the treatment due to significant deviations from the ideal membranous labyrinth, that was considered when the maneuvers were designed. This study aims to understand the dynamics of the endolymphatic fluid and otoconia, within the membranous labyrinth geometry, which may contribute to the ineffectiveness of the Epley maneuver. Simultaneously, the study seeks to explore methods to avoid or reduce treatment failure. DESIGN: We conducted a study on the Epley maneuver using numerical simulations based on a three-dimensional medical image reconstruction of the human left membranous labyrinth. A high-quality micro-computed tomography of a human temporal bone specimen was utilized for the image reconstruction, and a mathematical model for the endolymphatic fluid was developed and coupled with a spherical particle model representing otoconia inside the fluid. This allowed us to measure the position and time of each particle throughout all the steps of the maneuver, using equations that describe the physics behind benign paroxysmal positional vertigo. RESULTS: Numerical simulations of the standard Epley maneuver applied to this membranous labyrinth model yielded unsatisfactory results, as otoconia do not reach the frontside of the utricle, which in this study is used as the measure of success. The resting times between subsequent steps indicated that longer intervals are required for smaller otoconia. Using different angles of rotation can prevent otoconia from entering the superior semicircular canal or the posterior ampulla. Steps 3, 4, and 5 exhibited a heightened susceptibility to failure, as otoconia could be accidentally displaced into these regions. CONCLUSIONS: We demonstrate that modifying the Epley maneuver based on the numerical results obtained in the membranous labyrinth of the human specimen under study can have a significant effect on the success or failure of the treatment. The use of numerical simulations appears to be a useful tool for future canalith repositioning procedures that aim to personalize the treatment by modifying the rotation planes currently defined as the standard criteria.


Assuntos
Vertigem Posicional Paroxística Benigna , Humanos , Vertigem Posicional Paroxística Benigna/fisiopatologia , Vertigem Posicional Paroxística Benigna/diagnóstico por imagem , Microtomografia por Raio-X , Simulação por Computador , Osso Temporal/diagnóstico por imagem , Membrana dos Otólitos/fisiologia , Imageamento Tridimensional , Endolinfa/fisiologia , Orelha Interna/diagnóstico por imagem , Canais Semicirculares/diagnóstico por imagem , Canais Semicirculares/fisiologia , Posicionamento do Paciente/métodos
7.
J Comput Assist Tomogr ; 48(1): 110-115, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37558645

RESUMO

ABSTRACT: This study aimed to propose a patient positioning assistive technique using computed tomography (CT) scout images. A total of 210 patients who underwent CT scans in a single center, including on the upper abdomen, were divided into a study set of 127 patients for regression and 83 patients for verification. Linear regression analysis was performed to determine the R2 coefficient and the linear equation related to the mean pixel value of the scout image and ideal table height (TH ideal ). The average pixel values of the scout image were substituted into the regression equation to estimate the TH ideal . To verify the accuracy of this method, the distance between the estimated table height (TH est ) and TH ideal was measured. The medians of age (in years), gender (male/female), height (in centimeters), and body weight (in kilograms) for the regression and verification groups were 68 versus 70, 85/42 versus 55/28, 163.8 versus 163.0, and 59.9 versus 61.9, respectively. Linear regression analysis indicated a high coefficient of determination ( R2 = 0.91) between the mean pixel value of the scout image and TH ideal . The correlation coefficient between TH ideal and TH est was 0.95 (95% confidence interval, 0.92-0.97; P < 0.0001), systematic bias was 0.2 mm, and the limits of agreement were -5.4 to 5.9 ( P = 0.78). The offset of the table height with TH est was 2.8 ± 2.1 mm. The proposed estimation method using scout images could improve the automatic optimization of table height in CT, and it can be used as a general-purpose automatic positioning technique.


Assuntos
Tecnologia Assistiva , Tomografia Computadorizada por Raios X , Humanos , Masculino , Feminino , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Abdome , Posicionamento do Paciente/métodos
8.
Cardiovasc Ultrasound ; 22(1): 7, 2024 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-38858752

RESUMO

AIMS: To evaluate the feasibility of a transthoracic echocardiogram using an apical-subcostal protocol in invasive mechanical ventilation (IMV) and prone position. METHODS: Prospective study of adults who required a prone position during IMV. A pillow was placed only under the left hemithorax in the prone position to elevate and ease the apical and subcostal windows. A critical care cardiologist (prone group) acquired and evaluated the images using the apical-subcostal protocol. Besides, we used ambulatory echocardiograms performed as a comparative group (supine group). RESULTS: 86 patients were included, 43 in the prone and 43 in the supine. In the prone group, the indication to perform an echocardiogram was hemodynamic monitoring. All patients were ventilated with protective parameters, and the mean end-expiratory pressure was 10.6 cmH2O. The protocol was performed entirely in 42 of 43 patients in the prone group because one patient did not have any acoustic window. In the 43 patients in the prone group analyzed and compared to the supine group, global biventricular function was assessed in 97.7% (p = 1.0), severe heart valve disease in 88.4% (p = 0.055), ruled out of the presence of pulmonary hypertension in 76.7% (p = 0.80), pericardial effusion in 93% (p = 0.12), and volume status by inferior vena cava in 93% (p = 0.48). Comparing prone versus supine position, a statistical difference was found when evaluating the left ventricle apical 2-chamber view (65.1 versus 100%, p < 0.01) and its segmental function (53.4 versus 100%, p < 0.01). CONCLUSION: The echocardiogram using an apical-subcostal protocol is feasible in patients in the IMV and prone position.


Assuntos
Ecocardiografia , Estudos de Viabilidade , Unidades de Terapia Intensiva , Respiração Artificial , Humanos , Masculino , Decúbito Ventral , Feminino , Estudos Prospectivos , Respiração Artificial/métodos , Ecocardiografia/métodos , Pessoa de Meia-Idade , Posicionamento do Paciente/métodos , Idoso
9.
Retina ; 44(7): 1150-1156, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38470916

RESUMO

PURPOSE: To compare Supine versus Prone positioning in fresh rhegmatogenous retinal detachments treated with vitrectomy and gas tamponade. METHODS: This was a prospective randomized controlled trial of 72 eyes with fresh rhegmatogenous retinal detachment that underwent 25-gauge vitrectomy: 37 eyes were allotted supine position and 35 were allotted prone position. Cases were evaluated for single-surgery reattachment rates, best-corrected visual acuity, intraocular pressure, cataract formation, and any complications. The patients were followed up for a period of 3 months. RESULTS: Both groups had similar demographics, and no significant difference was found between the two groups in terms of extent of retinal detachment, position, and number of breaks. The anatomical success after single surgery was 97.3% in the Supine group and 94.3% in the Prone group ( P = 0.609). The best-corrected visual acuity at the end of 3 months was 0.44 ± 0.27 in the Supine group and 0.35 ± 0.27 in the Prone group ( P = 0.119) with a significant increase in best-corrected visual acuity preoperatively from 0.11 ± 0.22 and 0.13 ± 0.22 in Supine and Prone groups, respectively ( P = <0.001). The intraocular pressure in the two groups was comparable at each follow-up. The rates of cataract formation were also similar in the two groups-60% and 53.8% in Supine and Prone groups, respectively ( P = 1.00). Complications such as spikes in intraocular pressure, epiretinal membrane formation, and cystoid macular edema were similar in both groups. CONCLUSION: Rates of retinal reattachment were comparable in both groups showing that supine position is equally safe and effective for adequate tamponade.


Assuntos
Tamponamento Interno , Descolamento Retiniano , Acuidade Visual , Vitrectomia , Humanos , Vitrectomia/métodos , Descolamento Retiniano/cirurgia , Descolamento Retiniano/fisiopatologia , Descolamento Retiniano/diagnóstico , Decúbito Ventral , Masculino , Feminino , Acuidade Visual/fisiologia , Decúbito Dorsal , Estudos Prospectivos , Tamponamento Interno/métodos , Pessoa de Meia-Idade , Adulto , Pressão Intraocular/fisiologia , Idoso , Seguimentos , Posicionamento do Paciente/métodos , Fluorocarbonos/administração & dosagem , Resultado do Tratamento
10.
BMC Anesthesiol ; 24(1): 179, 2024 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-38769487

RESUMO

BACKGROUND: Video double-lumen tube (VDLT) intubation in lateral position is a potential alternative to intubation in supine position in patients undergoing thoracic surgery. This non-inferiority trial assessed the efficacy and safety of VDLT intubation in lateral position. METHODS: Patients (18-70 yr) undergoing right thoracoscopic lung surgery were randomized to either the left lateral position group (group L) or the supine position group (group S). The VDLT was placed under video larygoscopy. The primary endpoint was the intubation time. Secondary endpoints included VDLT displacement rate, intubation failure rate, the satisfaction of surgeon and nurse, and intubation-related adverse events. RESULTS: The analysis covered 80 patients. The total intubation time was 52.0 [20.4]s in group L and 34.3 [13.2]s in group S, with a mean difference of 17.6 s [95% confidence interval (CI): 9.9 s to 25.3 s; P = 0.050], failing to demonstrate non-inferiority with a non-inferiority margin of 10 s. Group L, compared with group S, had significantly lower VDLT displacement rate (P = 0.017) and higher nurse satisfaction (P = 0.026). No intubation failure occurred in any group. Intubation complications (P = 0.802) and surgeon satisfaction (P = 0.415) were comparable between two groups. CONCLUSIONS: The lateral VDLT intubation took longer time than in the supine position, and non-inferiority was not achieved. The incidence of displacement as the secondary endpoint was lower in the L group, possibly due to changing body positions beforehand. The indication of lateral VDLT intubation should be based on a balance between the safety of airway management and the lower incidence of displacement. TRIAL REGISTRATION: The study was registered at Chictr.org.cn with the number ChiCTR2200064831 on 19/10/2022.


Assuntos
Intubação Intratraqueal , Posicionamento do Paciente , Humanos , Intubação Intratraqueal/métodos , Pessoa de Meia-Idade , Feminino , Masculino , Adulto , Idoso , Posicionamento do Paciente/métodos , Adulto Jovem , Procedimentos Cirúrgicos Torácicos/métodos , Adolescente , Cirurgia Torácica Vídeoassistida/métodos
11.
Neurosurg Rev ; 47(1): 221, 2024 May 16.
Artigo em Inglês | MEDLINE | ID: mdl-38753263

RESUMO

Neurosurgical approach to lesions located in the occipital lobes or in the posterior fossa require very specific and time-consuming patient installations, such as the park bench position, the prone position, or the sitting position. Nevertheless, each of these position present major drawbacks regarding specific installation-related adverse events and potentially serious neurosurgical complications such as venous air embolism, iatrogenic intracranial hypertension, and supratentorial remote hematoma just to cite a few. In order to provide neurosurgeons with a simpler, physiologically-respective, easily tolerated, less time-consuming, and less provider or specific adverse events patient installation, Ochiai (1979) introduced the supine modified park-bench / lateral decubitus position. Given that this patient position has not gained wide visibility among the neurosurgical community despite its obvious numerous advantages over its classic counterparts, we provide our experience using this installation for neurosurgical approach to lesions located in the occipital lobes and in the posterior fossa.


Assuntos
Fossa Craniana Posterior , Procedimentos Neurocirúrgicos , Lobo Occipital , Posicionamento do Paciente , Humanos , Lobo Occipital/cirurgia , Procedimentos Neurocirúrgicos/métodos , Posicionamento do Paciente/métodos , Fossa Craniana Posterior/cirurgia , Decúbito Dorsal , Masculino , Postura
12.
J Ultrasound Med ; 43(7): 1353-1357, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38581172

RESUMO

Most subscapularis and serratus anterior muscles lie between the scapula and the thoracic cage. Evaluation of this area in patients with scapulothoracic dyskinesis, snapping scapular syndrome, or interscapular pain can provide valuable information to clinicians. However, ultrasound scanning of pathologies in this area is hindered by anatomical limitations. In this study, we described a simple patient setup position and scanning method for ultrasound evaluation and guided intervention of the subscapularis and serratus anterior muscles between the scapula and thoracic cage.


Assuntos
Escápula , Ultrassonografia de Intervenção , Humanos , Escápula/diagnóstico por imagem , Ultrassonografia de Intervenção/métodos , Injeções Intramusculares/métodos , Músculo Esquelético/diagnóstico por imagem , Posicionamento do Paciente/métodos
13.
J Ultrasound Med ; 43(6): 1037-1044, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38380860

RESUMO

OBJECTIVES: No consensus regarding the optimal position and location for the measurement of the inter-rectus distance (IRD) via ultrasound (US) has been reached. By investigating the intra- and interimage reliability of IRD measurements taken in different positions and at different locations within and between testers, this study provides a theoretical basis for the current situation. METHODS: The IRD was measured via US in 46 women at 42-60 days after delivery at the superior margin of the umbilicus and 3 cm above, 5 cm above and 3 cm below the umbilicus while the women were in the supine, crunch and standing positions. In the interimage test, every participant was tested 2 times by Physician X and 1 time by Physician Y; in the intraimage test, the images collected by Physician X during the first test were saved in the machines, and two measurements were performed by Physician X and one measurement was performed by Physician Y. Paired t tests and intraclass correlation coefficients (ICCs) were calculated. RESULTS: Only the first IRD measurements by tester X and tester Y at 3 cm below the umbilicus in the crunch position were significantly different (9.56 ± 6.00 versus 11.00 ± 5.55) (P < .05). All the ICCs were greater than .75, and the intratester ICCs were greater than or equal to the corresponding intertester ICCs. The ICCs at 3 cm below the umbilicus were the smallest in the supine and crunch positions and the largest in the standing position due to the increased frequency of IRD values of 0. The ICCs for the crunch position were greatest according to the intraimage test but smallest according to the interimage test. The interimage ICCs between the two testers in the supine position at the superior margin, 3 cm above, 5 cm above, and 3 cm below the umbilicus were .972, .974, .975, and .956, respectively. CONCLUSIONS: Ultrasound imaging (USI) is a reliable method for measuring the IRD in women in the early postpartum period. The dynamic measurement of the IRD at or above the umbilicus in the supine position by different testers in real time showed the highest reliability.


Assuntos
Período Pós-Parto , Ultrassonografia , Humanos , Feminino , Reprodutibilidade dos Testes , Ultrassonografia/métodos , Adulto , Músculos Abdominais/diagnóstico por imagem , Variações Dependentes do Observador , Adulto Jovem , Posicionamento do Paciente/métodos
14.
Paediatr Anaesth ; 34(6): 507-518, 2024 06.
Artigo em Inglês | MEDLINE | ID: mdl-38546348

RESUMO

Patient positioning interacts with a number of body systems and can impact clinically important perioperative outcomes. In this educational review, we present the available evidence on the impact that patient positioning can have in the pediatric perioperative setting. A literature search was conducted using search terms that focused on pediatric perioperative outcomes prioritized by contemporary research in this area. Several key themes were identified: the effects of positioning on respiratory outcomes, cardiovascular outcomes, enteral function, patient and carer-centered outcomes, and soft issue injuries. We encountered considerable heterogeneity in research in this area. There may be a role for lateral positioning to reduce respiratory adverse outcomes, head elevation for intubation and improved oxygenation, and upright positioning to reduce peri-procedural anxiety.


Assuntos
Posicionamento do Paciente , Assistência Perioperatória , Humanos , Criança , Posicionamento do Paciente/métodos , Assistência Perioperatória/métodos
15.
Ann Intern Med ; 176(4): JC47, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-37011392

RESUMO

SOURCE CITATION: Sharif S, Khoujah D, Greer A, et al. Vestibular suppressants for benign paroxysmal positional vertigo: a systematic review and meta-analysis of randomized controlled trials. Acad Emerg Med. 2022. [Epub ahead of print.] 36268806.


Assuntos
Vertigem Posicional Paroxística Benigna , Posicionamento do Paciente , Humanos , Vertigem Posicional Paroxística Benigna/diagnóstico , Vertigem Posicional Paroxística Benigna/terapia
16.
Urol Int ; 108(3): 190-197, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38290486

RESUMO

INTRODUCTION: We explored the viability of simultaneous bilateral endoscopic surgery (SBES) in the prone split-leg position for managing bilateral calculi. METHODS: We retrospectively reviewed 72 patients who underwent SBES, with procedures involving ureteroscopy (URS) and contralateral percutaneous nephrolithotomy (PNL) simultaneously, in prone split-leg position. RESULTS: Operative times averaged 109.38 ± 30.76 min, with an average hospital stay of 7.79 ± 3.78 days. The bilateral stone-free rate (SFR) was 70.83%, while URS and PNL demonstrated comparable unilateral SFR (83.33% and 79.17%, respectively). Receiver operating characteristics curves for predicting unilateral residual fragments yielded an area under the curve of 0.84 (URS) and 0.81 (PNL) with respective cutoff values of stone diameter of 11.55 mm and 23.52 mm. Fifty-seven (79.17%) and 15 (20.83%) patients encountered grade 0-1/2 complications, with no severe complications (grade 3-5) recorded. No significant changes in blood count or renal function were observed post-SBES. CONCLUSIONS: SBES in the prone split-leg position is a viable option for managing bilateral upper tract urolithiasis. Larger scale studies are needed to further assess safety and efficacy in various positions.


Assuntos
Estudos de Viabilidade , Nefrolitotomia Percutânea , Posicionamento do Paciente , Ureteroscopia , Humanos , Masculino , Feminino , Estudos Retrospectivos , Pessoa de Meia-Idade , Ureteroscopia/métodos , Projetos Piloto , Adulto , Nefrolitotomia Percutânea/métodos , Decúbito Ventral , Resultado do Tratamento , Idoso , Cálculos Renais/cirurgia , Cálculos Ureterais/cirurgia , Tempo de Internação , Duração da Cirurgia
17.
Skeletal Radiol ; 53(8): 1517-1528, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38378861

RESUMO

OBJECTIVE: Distances and angles measured from long-leg radiographs (LLR) are important for surgical decision-making. However, projectional radiography suffers from distortion, potentially generating differences between measurement and true anatomical dimension. These phenomena are not uniform between conventional radiography (CR) digital radiography (DR) and fan-beam technology (EOS). We aimed to identify differences between these modalities in an experimental setup. MATERIALS AND METHODS: A hemiskeleton was stabilized using an external fixator in neutral, valgus and varus knee alignment. Ten images were acquired for each alignment and each modality: one CR setup, two different DR systems, and an EOS. A total of 1680 measurements were acquired and analyzed. RESULTS: We observed great differences for dimensions and angles between the 4 modalities. Femoral head diameter measurements varied in the range of > 5 mm depending on the modality, with EOS being the closest to the true anatomical dimension. With functional leg length, a difference of 8.7% was observed between CR and EOS and with the EOS system being precise in the vertical dimension on physical-technical grounds, this demonstrates significant projectional magnification with CR-LLR. The horizontal distance between the medial malleoli varied by 20 mm between CR and DR, equating to 21% of the mean. CONCLUSIONS: Projectional distortion resulting in variations approaching 21% of the mean indicate, that our confidence on measurements from standing LLR may not be justified. It appears likely that among the tested equipment, EOS-generated images are closest to the true anatomical situation most of the time.


Assuntos
Intensificação de Imagem Radiográfica , Humanos , Intensificação de Imagem Radiográfica/métodos , Posição Ortostática , Perna (Membro)/diagnóstico por imagem , Posicionamento do Paciente/métodos
18.
Neurocrit Care ; 40(2): 391-394, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37697130

RESUMO

Intracranial pressure is routinely monitored in most intensive care units caring for patients with severe neurological insults and, together with continuous arterial blood pressure measurement, allows for monitoring of cerebral perfusion pressure (CPP). CPP is the driving pressure of blood flow to the brain and is used to guide therapy. However, there is considerable inconsistency in the literature regarding how CPP is technically measured and, more specifically, the appropriate placement of the arterial pressure transducer. Depending on patient positioning and where the arterial pressure transducer is placed, the mean arterial pressure used for CPP calculation can vary widely by up to 15 mm Hg, which is greater than the acceptable variation in target ranges used clinically. Physiologically, the arterial pressure transducer should be placed at the level of the foramen of Monro for CPP measurement, but it is commonly set at the level of the right atrium for systematic measurement. Mean arterial pressure measurement at the level of the right atrium can lead to overestimation and potentially critically low actual CPP levels when the head is elevated, and measurement at the level of the foramen of Monro will underestimate systemic pressures, increasing the risk of excessive and unnecessary use of vasopressors and fluid. At the Karolinska University Hospital neurointensive care unit, we have used a split dual-transducer system, measuring arterial pressure both at the level of the foramen of Monro and at the level of the right atrium from a single arterial source. In doing so, we work with constants and can monitor and target optimum arterial pressures to better secure perfusion to all organs, with potentially less risk of cerebral ischemia or overuse of vasopressors and fluids, which may affect outcome.


Assuntos
Pressão Arterial , Circulação Cerebrovascular , Humanos , Circulação Cerebrovascular/fisiologia , Pressão Arterial/fisiologia , Pressão Intracraniana/fisiologia , Posicionamento do Paciente , Unidades de Terapia Intensiva , Vasoconstritores/uso terapêutico , Pressão Sanguínea/fisiologia , Monitorização Fisiológica
19.
Acta Med Okayama ; 78(3): 215-225, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38902209

RESUMO

We propose a sitting position that achieves both high image quality and a reduced radiation dose in elbow joint imaging by area detector computed tomography (ADCT), and we compared it with the 'superman' and supine positions. The volumetric CT dose index (CTDIvol) for the sitting, superman, and supine positions were 2.7, 8.0, and 20.0 mGy and the dose length products (DLPs) were 43.4, 204.7, and 584.8 mGy • cm, respectively. In the task-based transfer function (TTF), the highest value was obtained for the sitting position in both bone and soft tissue images. The noise power spectrum (NPS) of bone images showed that the superman position had the lowest value up to approx. 1.1 cycles/mm or lower, whereas the sitting position had the lowest value when the NPS was greater than approx. 1.1 cycles/mm. The overall image quality in an observer study resulted in the following median Likert scores for Readers 1 and 2: 5.0 and 5.0 for the sitting position, 4.0 and 3.5 for the superman position, and 4.0 and 2.0 for the supine position. These results indicate that our proposed sitting position with ADCT of the elbow joint can provide superior image quality and allow lower radiation doses compared to the superman and supine positions.


Assuntos
Articulação do Cotovelo , Posicionamento do Paciente , Tomografia Computadorizada por Raios X , Humanos , Articulação do Cotovelo/diagnóstico por imagem , Masculino , Feminino , Tomografia Computadorizada por Raios X/métodos , Posicionamento do Paciente/métodos , Pessoa de Meia-Idade , Adulto , Doses de Radiação , Idoso , Decúbito Dorsal
20.
Am J Otolaryngol ; 45(4): 104241, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38574512

RESUMO

BACKGROUND: About 12.5 % of patients diagnosed with benign paroxysmal positional vertigo (BPPV), experience persistent BPPV where it is unknown why some BPPV cases are very refractory (vrBPPV) to treatment. OBJECTIVES: The primary objective was to investigate if patients with vrBPPV could be successfully treated with a mechanical rotation chair (MRC) adjusted to the exact vertical semicircular canal (SCC) angles of the individual patient. Secondary endpoint was to determine if inner ear anomalies were predominant in these patients. METHODS: This prospective clinical trial included 20 patients (main group) who underwent computed tomography (CT) with measurements of the bony island and the width between the SCC walls of the posterior leg of the lateral SCCs. The inter-SCC angles, the angles between the sagittal plane and the vertical SCCs were compared to the presumed mean standard angles of the SCCs. Of these, 14 patients (subgroup) underwent individualized treatment with the Rotundum® repositioning chair according to their measured SCC angles. RESULTS: All measured SCC angles differed significantly (p < 0.05) from the presumed mean standard SCC angles, except the angle between the sagittal plane and the left posterior SCC (p-SCC). Three out of 14 patients experienced subjective and objective remission after treatment with this MRC. Six out of 14 patients experienced either subjective remission or objective remission. CONCLUSIONS: Patients with vrBPPV have vertical SCC angles that differ significantly from the presumed mean standard SCC angles. Individualized treatment with this MRC successfully treated 21.4 % of the patients with vrBPPV and provided subjective relief for 42.9 %.


Assuntos
Vertigem Posicional Paroxística Benigna , Posicionamento do Paciente , Canais Semicirculares , Tomografia Computadorizada por Raios X , Humanos , Vertigem Posicional Paroxística Benigna/terapia , Masculino , Feminino , Estudos Prospectivos , Pessoa de Meia-Idade , Idoso , Posicionamento do Paciente/métodos , Resultado do Tratamento , Canais Semicirculares/fisiopatologia , Canais Semicirculares/diagnóstico por imagem , Rotação , Adulto
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA