Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Phys Rev Lett ; 127(12): 125001, 2021 Sep 17.
Artículo en Inglés | MEDLINE | ID: mdl-34597087

RESUMEN

Inertial confinement fusion implosions designed to have minimal fluid motion at peak compression often show significant linear flows in the laboratory, attributable per simulations to percent-level imbalances in the laser drive illumination symmetry. We present experimental results which intentionally varied the mode 1 drive imbalance by up to 4% to test hydrodynamic predictions of flows and the resultant imploded core asymmetries and performance, as measured by a combination of DT neutron spectroscopy and high-resolution x-ray core imaging. Neutron yields decrease by up to 50%, and anisotropic neutron Doppler broadening increases by 20%, in agreement with simulations. Furthermore, a tracer jet from the capsule fill-tube perturbation that is entrained by the hot-spot flow confirms the average flow speeds deduced from neutron spectroscopy.

2.
Phys Rev Lett ; 123(16): 165001, 2019 Oct 18.
Artículo en Inglés | MEDLINE | ID: mdl-31702328

RESUMEN

Neutron spectra from secondary ^{3}H(d,n)α reactions produced by an implosion of a deuterium-gas capsule at the National Ignition Facility have been measured with order-of-magnitude improvements in statistics and resolution over past experiments. These new data and their sensitivity to the energy loss of fast tritons emitted from thermal ^{2}H(d,p)^{3}H reactions enable the first statistically significant investigation of charged-particle stopping via the emitted neutron spectrum. Radiation-hydrodynamic simulations, constrained to match a number of observables from the implosion, were used to predict the neutron spectra while employing two different energy loss models. This analysis represents the first test of stopping models under inertial confinement fusion conditions, covering plasma temperatures of k_{B}T≈1-4 keV and particle densities of n≈(12-2)×10^{24} cm^{-3}. Under these conditions, we find significant deviations of our data from a theory employing classical collisions whereas the theory including quantum diffraction agrees with our data.

3.
Phys Rev Lett ; 115(10): 105001, 2015 Sep 04.
Artículo en Inglés | MEDLINE | ID: mdl-26382681

RESUMEN

Hydrodynamic instabilities can cause capsule defects and other perturbations to grow and degrade implosion performance in ignition experiments at the National Ignition Facility (NIF). Here, we show the first experimental demonstration that a strong unsupported first shock in indirect drive implosions at the NIF reduces ablation front instability growth leading to a 3 to 10 times higher yield with fuel ρR>1 g/cm(2). This work shows the importance of ablation front instability growth during the National Ignition Campaign and may provide a path to improved performance at the high compression necessary for ignition.

4.
Phys Rev Lett ; 112(2): 025002, 2014 Jan 17.
Artículo en Inglés | MEDLINE | ID: mdl-24484021

RESUMEN

We present the first results from an experimental campaign to measure the atomic ablator-gas mix in the deceleration phase of gas-filled capsule implosions on the National Ignition Facility. Plastic capsules containing CD layers were filled with tritium gas; as the reactants are initially separated, DT fusion yield provides a direct measure of the atomic mix of ablator into the hot spot gas. Capsules were imploded with x rays generated in hohlraums with peak radiation temperatures of ∼294 eV. While the TT fusion reaction probes conditions in the central part (core) of the implosion hot spot, the DT reaction probes a mixed region on the outer part of the hot spot near the ablator-hot-spot interface. Experimental data were used to develop and validate the atomic-mix model used in two-dimensional simulations.

5.
Phys Rev Lett ; 111(5): 052501, 2013 Aug 02.
Artículo en Inglés | MEDLINE | ID: mdl-23952390

RESUMEN

Neutron time-of-flight spectra from inertial confinement fusion experiments with tritium-filled targets have been measured at the National Ignition Facility. These spectra represent a significant improvement in energy resolution and statistics over previous measurements, and afford the first definitive observation of a peak resulting from sequential decay through the ground state of (5)He at low reaction energies E(c.m.) 100

6.
Rev Sci Instrum ; 94(6)2023 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-37862497

RESUMEN

Neutrons generated in Inertial Confinement Fusion (ICF) experiments provide valuable information to interpret the conditions reached in the plasma. The neutron time-of-flight (nToF) technique is well suited for measuring the neutron energy spectrum due to the short time (100 ps) over which neutrons are typically emitted in ICF experiments. By locating detectors 10s of meters from the source, the neutron energy spectrum can be measured to high precision. We present a contextual review of the current state of the art in nToF detectors at ICF facilities in the United States, outlining the physics that can be measured, the detector technologies currently deployed and analysis techniques used.

7.
Rev Sci Instrum ; 92(4): 043527, 2021 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-34243407

RESUMEN

The Real Time Nuclear Activation Detector (RTNAD) array at NIF measures the distribution of 14 MeV neutrons emitted by deuterium-tritium (DT) fueled inertial confinement fusion implosions. The uniformity of the neutron distribution is an important indication of implosion symmetry and DT shell integrity. The array consists of 48 LaBr3(Ce) crystal gamma-ray spectrometers mounted outside the NIF target chamber, which continuously monitor the slow decay of the 909 keV gamma-ray line from activated 89Zr located in Zr cups surrounding each crystal. The measured decay rate dramatically increases during a DT implosion in proportion to the number of 14 MeV neutrons striking each Zr cup. The neutrons produce activated 89Zr through an (n, 2n) reaction on 90Zr, which is insensitive to low energy neutrons. The neutron flux along the detector line-of-sight at shot time is determined by extrapolating the fitted 909 keV decay curve back to shot time. Automatic analysis algorithms were developed to handle the non-stop data stream. The large number of detectors and the high statistical accuracy of the array enable the spherical harmonic modes of the neutron angular distribution to be measured up to L ≤ 4 to provide a better understanding of implosion dynamics. In addition, these data combined with measurements of the down-scattered neutrons can be used to derive fuel areal density distributions. This paper will describe the RTNAD hardware and analysis procedures.

8.
Rev Sci Instrum ; 92(5): 053543, 2021 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-34243308

RESUMEN

Neutron-yield diagnostics at the NIF have been upgraded to include 48 detectors placed around the NIF target chamber to assess the DT-neutron-yield isotropy for inertial confinement fusion experiments. Real-time neutron-activation detectors are used to understand yield asymmetries due to Doppler shifts in the neutron energy attributed to hotspot motion, variations in the fuel and ablator areal densities, and other physics effects. In order to isolate target physics effects, we must understand the contribution due to neutron scattering associated with the different hardware configurations used for each experiment. We present results from several calibration experiments that demonstrate the ability to achieve our goal of 1% or better precision in determining the yield isotropy.

9.
Rev Sci Instrum ; 92(5): 053526, 2021 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-34243327

RESUMEN

Recent inertial confinement fusion measurements have highlighted the importance of 3D asymmetry effects on implosion performance. One prominent example is the bulk drift velocity of the deuterium-tritium plasma undergoing fusion ("hotspot"), vHS. Upgrades to the National Ignition Facility neutron time-of-flight diagnostics now provide vHS to better than 1 part in 104 and enable cross correlations with other measurements. This work presents the impact of vHS on the neutron yield, downscatter ratio, apparent ion temperature, electron temperature, and 2D x-ray emission. The necessary improvements to diagnostic suites to take these measurements are also detailed. The benefits of using cross-diagnostic analysis to test hotspot models and theory are discussed, and cross-shot trends are shown.

10.
Rev Sci Instrum ; 92(4): 043512, 2021 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-34243456

RESUMEN

Nuclear diagnostics provide measurements of inertial confinement fusion implosions used as metrics of performance for the shot. The interpretation of these measurements for shots with low mode asymmetries requires a way of combining the data to produce a "sky map" where the individual line-of-sight values are used to interpolate to other positions in the sky. These interpolations can provide information regarding the orientation of the low mode asymmetries. We describe the interpolation method, associated uncertainties, and correlations between different metrics, e.g., Tion, down scatter ratio, and hot-spot velocity direction. This work is also related to recently reported studies [H. G. Rinderknecht et al., Phys. Rev. Lett. 124, 145002 (2020) and K. M. Woo et al., Phys. Plasmas 27, 062702 (2020)] of low mode asymmetries. We report an analysis that makes use of a newly commissioned line of sight, a scheme for incorporating multiple neutron spectrum measurement types, and recent work on the sources of implosion asymmetry to provide a more complete picture of implosion performance.

11.
Rev Sci Instrum ; 92(2): 023513, 2021 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-33648112

RESUMEN

The measurement of plasma hotspot velocity provides an important diagnostic of implosion performance for inertial confinement fusion experiments at the National Ignition Facility. The shift of the fusion product neutron mean kinetic energy as measured along multiple line-of-sight time-of-flight spectrometers provides velocity vector components from which the hotspot velocity is inferred. Multiple measurements improve the hotspot velocity inference; however, practical considerations of available space, operational overhead, and instrumentation costs limit the number of possible line-of-sight measurements. We propose a solution to this classical "experiment design" problem that optimizes the precision of the velocity inference for a limited number of measurements.

12.
Rev Sci Instrum ; 89(10): 10I138, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-30399709

RESUMEN

An important diagnostic value of a shot at the National Ignition Facility is the resultant center-of-mass motion of the imploding capsule. This residual velocity reduces the efficiency of converting laser energy into plasma temperature. A new analysis method extracts the effective hot spot motion by using information from multiple neutron time-of-flight (nToF) lines-of-sight (LoSs). This technique fits a near Gaussian spectrum to the nToF scope traces and overcomes reliance on models to relate the plasma temperature to the mean energy of the emitted neutrons. This method requires having at least four nToF LoSs. The results of this analysis will be compared to an approach where each LoS is analyzed separately and a model is used to infer the mean energy of the emitted neutrons.

13.
Rev Sci Instrum ; 89(10): 10I136, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-30399741

RESUMEN

Neutron time-of-flight diagnostics at the NIF were recently outfitted with Cherenkov detectors. A fused silica radiator delivers sub-nanosecond response time and is optically coupled to a microchannel plate photomultiplier tube with gain from ∼1 to 104. Capitalizing on fast time response and gamma-ray sensitivity, these systems can provide better than 30 ps precision for measuring first moments of neutron distributions. Generation of ab initio instrument response functions (IRFs) is critical to meet the <1% uncertainty needed. A combination of Monte Carlo modeling, benchtop characterization, and in situ comparison is employed. Close agreement is shown between the modeled IRFs and in situ measurements using the NIF's short-pulse advanced radiographic capability beams. First and second moments of neutron spectra calculated using ab initio IRFs agree well with established scintillator measurements. Next-step designs offer increased sensitivity and time-response.

14.
Rev Sci Instrum ; 89(10): 10I120, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-30399816

RESUMEN

A fused silica Cherenkov radiator has been implemented at the National Ignition Facility to provide a new high precision measurement of the time-of-flight spectrum of 14.1 MeV DT fusion neutrons. This detector enables a high precision (<30 ps) co-registered measurement of both a thresholded γ-ray and a neutron spectrum on a single record. Other methods typically require γ and neutron signals to be co-registered via other diagnostics and/or dedicated timing experiments. Analysis of the co-registered γ and neutron signals allows precise extraction of the mean neutron energy and bulk hot-spot velocity, both of which were not possible with prior scintillator technologies. Initial measurements demonstrate the feasibility of this measurement and indicate that combined detection of neutrons and γ-rays on multiple lines-of-sight should enable the bulk vector velocity of the implosion hot-spot to be determined to ≈5 km/s and reduced uncertainty in the spectral width ≈0.1 keV.

15.
Rev Sci Instrum ; 89(10): 10I135, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-30399914

RESUMEN

The temporal response of a microchannel plate photomultiplier tube used in the suite of neutron time of flight (nToF) diagnostics at the National Ignition Facility has been characterized to reduce uncertainty in, and understanding of, shot parameters obtained from nTOF data. A short pulse laser, neutral density glass filters, and electrical attenuators were used to gather statistically significant samples of photodetector impulse response functions (IRF) in rapid succession. Individual components have been absolutely calibrated to minimize systematic uncertainties. The zeroth (collected charge), first (transit time), and second central moments (transit time spread) of the IRF were calculated as either the bias voltage or the amount of light incident on the detector was varied. Timing reference was provided by a monitor photodiode viewing a pickoff of the incident laser pulse. The primary sources of uncertainty are jitter in the monitor photodiode and the statistical variation across our measurement period. The spreads in the first moment, with respect to the timing photodiode, and the square root of the second central moment were found to be less than 50 ps and 150 ps, respectively.

16.
Rev Sci Instrum ; 89(10): 10I140, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-30399962

RESUMEN

Cherenkov radiators deployed to measure the neutron time-of-flight spectrum have response times associated with the neutron transit across the detector and are free from long time response tails characteristic of scintillation detectors. The Cherenkov radiation results from simple physical processes which makes them amenable to high fidelity Monte Carlo simulation. The instrument response function of neutron time-of-flight systems is a major contributor to both the systematic and statistical uncertainties of the parameters used to describe these spectra; in particular, the first and second moments of these distributions are associated with arrival time, t0, and ion temperature, Tion. We present the results of uncertainty analysis showing the significant reduction of the uncertainty in determining these quantities in the Cherenkov detector system recently deployed at NIF. The increased sensitivity to gamma radiation requires additional consideration of the effect of this background to the uncertainties in both t0 and Tion.

17.
Rev Sci Instrum ; 89(10): 10I122, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-30399883

RESUMEN

A Cherenkov neutron time-of-flight (nTOF) detector developed and constructed at Lawrence Livermore National Laboratory was tested at 13 m from the target in a collimated line of sight (LOS) and at 5.3 m from the target in the open space inside the OMEGA Target Bay. Neutrons interacting with the quartz rod generate gammas, which through Compton scattering produce relativistic electrons that give rise to Cherenkov light. A photomultiplier tube (PMT) transferred the Cherenkov light into an amplified electrical signal. The Cherenkov nTOF detector consists of an 8-mm-diam, 25-cm quartz hexagonal prism coupled with a Hamamatsu gated PMT R5916U-52. The tests were performed with DT direct-drive implosions with cryogenic and room-temperature targets, producing a wide range of neutron yields and ion temperatures. The results of the tests and comparison with other nTOF detectors on OMEGA are presented. In the collimated LOS at 13 m from the target, the Cherenkov nTOF detector demonstrated good precision measurement in both the yield and ion temperature for DT yields above 3 × 1013.

18.
Rev Sci Instrum ; 87(11): 11D802, 2016 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-27910485

RESUMEN

Sixty-four neutral density filters constructed of metal plates with 88 apertures of varying diameter have been radiographed with a soft x-ray source and CCD camera at National Security Technologies, Livermore. An analysis of the radiographs fits the radial dependence of the apertures' image intensities to sigmoid functions, which can describe the rapidly decreasing intensity towards the apertures' edges. The fitted image intensities determine the relative attenuation value of each filter. Absolute attenuation values of several imaged filters, measured in situ during calibration experiments, normalize the relative quantities which are now used in analyses of neutron spectrometer data at the National Ignition Facility.

19.
Rev Sci Instrum ; 87(11): 11E715, 2016 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-27910388

RESUMEN

The Neutron Imaging System at the National Ignition Facility is used to observe the primary ∼14 MeV neutrons from the hotspot and down-scattered neutrons (6-12 MeV) from the assembled shell. Due to the strong spatial dependence of the primary neutron fluence through the dense shell, the down-scattered image is convolved with the primary-neutron fluence much like a backlighter profile. Using a characteristic scattering angle assumption, we estimate the primary neutron fluence and compensate the down-scattered image, which reveals information about asymmetry that is otherwise difficult to extract without invoking complicated models.

20.
Rev Sci Instrum ; 87(11): 11D841, 2016 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-27910423

RESUMEN

A common analysis procedure minimizes the ln-likelihood that a set of experimental observables matches a parameterized model of the observation. The model includes a description of the underlying physical process as well as the instrument response function (IRF). In the case investigated here, the National Ignition Facility (NIF) neutron time-of-flight (nTOF) spectrometers, the IRF is constructed from measurements and models. IRF measurements have a finite precision that can make significant contributions to determine the uncertainty estimate of the physical model's parameters. We apply a Bayesian analysis to properly account for IRF uncertainties in calculating the ln-likelihood function used to find the optimum physical parameters.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA