Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Diagnostics (Basel) ; 14(7)2024 Mar 24.
Artículo en Inglés | MEDLINE | ID: mdl-38611596

RESUMEN

The performance of the Xpert Xpress CoV-2/Flu/RSV plus and Alinity m Resp-4-Plex Assays were evaluated using 167 specimens, including 158 human respiratory specimens and 9 external quality assessment program (EQAP) samples. For respiratory specimens, CoV-2/Flu/RSV plus exhibited perfect agreement with the standard-of-care (SOC) methods (Cohen's κ: 1, 100% agreement). The overall positive and negative percent agreement (PPA and NPA) were 100%, with 95% confidence intervals of 96.50 to 100% and 85.70 to 100%, respectively. On the other hand, Resp-4-Plex revealed an almost perfect agreement with the SOC methods (Cohen's κ: 0.92, 97.71% agreement). The overall PPA and NPA were 100% (95.76 to 100%) and 88.46% (70.20 to 96.82%), respectively. For EQAP samples, the results of CoV-2/Flu/RSV plus (9/9) and Resp-4-Plex (4/4) were concordant with the expected results. The experimental limit of detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) was the lowest (25 copies/mL for both methods), and that of the respiratory syncytial virus was the highest (400 copies/mL for CoV-2/Flu/RSV plus and 100 copies/mL for Resp-4-Plex). Threshold cycle (Ct) value correlation showed a large positive linear association between CoV-2/Flu/RSV plus and Resp-4-Plex, with R-squared values of 0.92-0.97, and on average, the Ct values of CoV-2/Flu/RSV plus were higher than that of Resp-4-Plex by 1.86-2.78, except for Flu A1 target (-0.66). To conclude, the performance of both assay was comparable to the SOC methods for both upper and lower respiratory specimens. Implementation of these rapid assay may reinforce the diagnostic capacity for the post-pandemic co-circulation of SARS-CoV-2 and other respiratory viruses.

2.
Viruses ; 16(4)2024 04 13.
Artículo en Inglés | MEDLINE | ID: mdl-38675941

RESUMEN

The BIOFIRE SPOTFIRE Respiratory (R) Panel is a novel, in vitro diagnostic PCR assay with 15 pathogen targets. The runtime is about 15 min which is the shortest among similar panels in the market. We evaluated the performance of the SPOTFIRE R Panel with 151 specimens, including 133 collected from the upper respiratory tract (URT), 13 from the lower respiratory tract (LRT) and 5 external quality assessment program (EQAP) samples. The respiratory specimens were enrolled throughout the first two post-COVID-19 influenza seasons in Hong Kong (March to December 2023). For URT specimens, full concordance was observed between the SPOTFIRE R Panel and the standard-of-care FilmArray Respiratory 2.1 plus Panel (RP2.1plus) for 109 specimens (109/133, 81.95%). After discrepant analysis, the SPOTFIRE R Panel identified more pathogens than the RP2.1plus in 15 specimens and vice versa in 3 specimens. The per-target negative and positive percentage agreement (NPA and PPA) were 92.86-100% except the PPA of adenovirus (88.24%). For LRT and EQAP samples, all results were fully concordant. To conclude, the performance of the SPOTFIRE R Panel was comparable to the RP2.1plus.


Asunto(s)
COVID-19 , Infecciones del Sistema Respiratorio , SARS-CoV-2 , Humanos , COVID-19/diagnóstico , COVID-19/virología , Infecciones del Sistema Respiratorio/virología , Infecciones del Sistema Respiratorio/diagnóstico , Hong Kong , SARS-CoV-2/genética , SARS-CoV-2/aislamiento & purificación , Sensibilidad y Especificidad , Técnicas de Diagnóstico Molecular/métodos , Prueba de Ácido Nucleico para COVID-19/métodos
3.
Viruses ; 15(9)2023 Aug 26.
Artículo en Inglés | MEDLINE | ID: mdl-37766227

RESUMEN

We reviewed the multiplex PCR results of 20,127 respiratory specimens tested in a hospital setting from January 2014 to April 2023. The seasonal oscillation patterns of 17 respiratory viruses were studied. Compared with 2014-2019, a prominent drop in PCR positivity (from 64.46-69.21% to 17.29-29.89%, p < 0.001) and virus diversity was observed during the COVID-19 pandemic, with predominance of rhinovirus/enterovirus, sporadic spikes of parainfluenza viruses 3 and 4, respiratory syncytial virus and SARS-CoV-2, and rare detection of influenza viruses, metapneumovirus, adenovirus and coronaviruses. The suppressed viruses appeared to regain activity from the fourth quarter of 2022 when pandemic interventions had been gradually relaxed in Hong Kong. With the co-circulation of SARS-CoV-2 and seasonal respiratory viruses, surveillance of their activity and an in-depth understanding of the clinical outcomes will provide valuable insights for improved public health measures and reducing disease burden.

4.
Vaccines (Basel) ; 10(8)2022 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-36016210

RESUMEN

Immune escape is observed with SARS-CoV-2 Omicron (Pango lineage B.1.1.529), the predominant circulating strain worldwide. A booster dose was shown to restore immunity against Omicron infection; however, real-world data comparing mRNA (BNT162b2; Comirnaty) and inactivated vaccines' (CoronaVac; Sinovac) homologous and heterologous boosting are lacking. A retrospective study was performed to compare the rate and outcome of COVID-19 in healthcare workers (HCWs) with various vaccination regimes during a territory-wide Omicron BA.2.2 outbreak in Hong Kong. During the study period from 1 February to 31 March 2022, 3167 HCWs were recruited, and 871 HCWs reported 746 and 183 episodes of significant household and non-household close contact. A total of 737 HCWs acquired COVID-19, all cases of which were all clinically mild. Time-dependent Cox regression showed that, compared with two-dose vaccination, three-dose vaccination reduced infection risk by 31.7% and 89.3% in household contact and non-household close contact, respectively. Using two-dose BNT162b2 as reference, two-dose CoronaVac recipient had significantly higher risk of being infected (HR 1.69 p < 0.0001). Three-dose BNT162b2 (HR 0.4778 p< 0.0001) and two-dose CoronaVac + BNT162b2 booster (HR 0.4862 p = 0.0157) were associated with a lower risk of infection. Three-dose CoronaVac and two-dose BNT162b2 + CoronaVac booster were not significantly different from two-dose BNT162b2. The mean time to achieve negative RT-PCR or E gene cycle threshold 31 or above was not affected by age, number of vaccine doses taken, vaccine type, and timing of the last dose. In summary, we have demonstrated a lower risk of breakthrough SARS-CoV-2 infection in HCWs given BNT162b2 as a booster after two doses of BNT162b2 or CoronaVac.

5.
Diagn Pathol ; 15(1): 45, 2020 May 06.
Artículo en Inglés | MEDLINE | ID: mdl-32375813

RESUMEN

BACKGROUND: Human papillomavirus (HPV) testing has been employed by several European countries to augment cytology-based cervical screening programs. A number of research groups have demonstrated potential utility of next-generation sequencing (NGS) for HPV genotyping, with comparable performance and broader detection spectrum than current gold standards. Nevertheless, most of these NGS platforms may not be the best choice for medium sample throughput and laboratories with less resources and space. In light of this, we developed a Nanopore sequencing assay for HPV genotyping and compared its performance with cobas HPV Test and Roche Linear Array HPV Genotyping Test (LA). METHODS: Two hundred and one cervicovaginal swabs were routinely tested for Papanicolaou smear, cobas HPV Test and LA. Residual DNA was used for Nanopore protocol after routine testing. Briefly, HPV L1 region was amplified using PGMY and MGP primers, and PCR-positive specimens were sequenced on MinION flow cells (R9.4.1). Data generated in first 2 h were aligned with reference sequences from Papillomavirus Episteme database for genotyping. RESULTS: Nanopore detected 96 HPV-positive (47.76%) and 95 HPV-negative (47.26%) specimens, with 10 lacking ß-globin band and not further analyzed (4.98%). Substantial agreement was achieved with cobas HPV Test and LA (κ: 0.83-0.93). In particular, Nanopore appeared to be more sensitive than cobas HPV Test for HPV 52 (n = 7). For LA, Nanopore revealed higher concordance for high-risk (κ: 0.93) than non-high risk types (κ: 0.83), and with similar high-risk positivity in each cytology grading. Nanopore also provided better resolution for HPV 52 in 3 specimens co-infected with HPV 33 or 58, and for HPV 87 which was identified as HPV 84 by LA. Interestingly, Nanopore identified 5 additional HPV types, with an unexpected high incidence of HPV 90 (n = 12) which was reported in North America and Belgium but not in Hong Kong. CONCLUSIONS: We developed a Nanopore workflow for HPV genotyping which was economical (about USD 50.77 per patient specimen for 24-plex runs), and with comparable or better performance than 2 reference methods in the market. Future prospective study with larger sample size is warranted to further evaluate test performance and streamline the protocol.


Asunto(s)
Alphapapillomavirus/genética , Secuenciación de Nanoporos/métodos , Infecciones por Papillomavirus/diagnóstico , Infecciones por Papillomavirus/virología , Adulto , Detección Precoz del Cáncer/métodos , Femenino , Técnicas de Genotipaje/métodos , Humanos , Persona de Mediana Edad , Frotis Vaginal
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA