Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
1.
Am J Physiol Renal Physiol ; 327(1): F91-F102, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38721662

RESUMEN

The lack of standardization in antibody validation remains a major contributor to irreproducibility of human research. To address this, we have applied a standardized approach to validate a panel of antibodies to identify 18 major cell types and 5 extracellular matrix compartments in the human kidney by immunofluorescence (IF) microscopy. We have used these to generate an organ mapping antibody panel for two-dimensional (2-D) and three-dimensional (3-D) cyclical IF (CyCIF) to provide a more detailed method for evaluating tissue segmentation and volumes using a larger panel of markers than would normally be possible using standard fluorescence microscopy. CyCIF also makes it possible to perform multiplexed IF microscopy of whole slide images, which is a distinct advantage over other multiplexed imaging technologies that are applicable to limited fields of view. This enables a broader view of cell distributions across larger anatomical regions, allowing a better chance to capture localized regions of dysfunction in diseased tissues. These methods are broadly accessible to any laboratory with a fluorescence microscope, enabling spatial cellular phenotyping in normal and disease states. We also provide a detailed solution for image alignment between CyCIF cycles that can be used by investigators to perform these studies without programming experience using open-sourced software. This ability to perform multiplexed imaging without specialized instrumentation or computational skills opens the door to integration with more highly dimensional molecular imaging modalities such as spatial transcriptomics and imaging mass spectrometry, enabling the discovery of molecular markers of specific cell types, and how these are altered in disease.NEW & NOTEWORTHY We describe here validation criteria used to define on organ mapping panel of antibodies that can be used to define 18 cell types and five extracellular matrix compartments using cyclical immunofluorescence (CyCIF) microscopy. As CyCIF does not require specialized instrumentation, and image registration required to assemble CyCIF images can be performed by any laboratory without specialized computational skills, this technology is accessible to any laboratory with access to a fluorescence microscope and digital scanner.


Asunto(s)
Anticuerpos , Riñón , Microscopía Fluorescente , Humanos , Microscopía Fluorescente/métodos , Riñón/inmunología , Riñón/metabolismo , Anticuerpos/inmunología , Técnica del Anticuerpo Fluorescente/métodos , Reproducibilidad de los Resultados , Matriz Extracelular/metabolismo , Matriz Extracelular/inmunología , Imagenología Tridimensional/métodos
2.
Anal Chem ; 95(2): 1176-1183, 2023 01 17.
Artículo en Inglés | MEDLINE | ID: mdl-36574465

RESUMEN

Gangliosides are acidic glycosphingolipids, containing ceramide moieties and oligosaccharide chains with one or more sialic acid residue(s) and are highly diverse isomeric structures with distinct biological roles. Matrix-assisted laser desorption/ionization imaging mass spectrometry (MALDI IMS) enables the untargeted spatial analysis of gangliosides, among other biomolecules, directly from tissue sections. Integrating trapped ion mobility spectrometry with MALDI IMS allows for the analysis of isomeric lipid structures in situ. Here, we demonstrate the gas-phase separation and identification of disialoganglioside isomers GD1a and GD1b that differ in the position of a sialic acid residue, in multiple samples, including a standard mixture of both isomers, a biological extract, and directly from thin tissue sections. The unique spatial distributions of GD1a/b (d36:1) and GD1a/b (d38:1) isomers were determined in rat hippocampus and spinal cord tissue sections, demonstrating the ability to structurally characterize and spatially map gangliosides based on both the carbohydrate chain and ceramide moieties.


Asunto(s)
Gangliósidos , Ácido N-Acetilneuramínico , Ratones , Ratas , Animales , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/métodos , Gangliósidos/análisis , Encéfalo , Ceramidas
3.
Anal Chem ; 92(6): 4340-4348, 2020 03 17.
Artículo en Inglés | MEDLINE | ID: mdl-32053357

RESUMEN

Careful transfer of ions into the gas-phase permits the measurement of protein structures, with ion mobility-mass spectrometry, which provides shape and stoichiometry information. Collision cross sections (CCS) can be obtained from measurements made of the ions mobility through a given gas, and such structural information once obtained should also permit interlaboratory comparisons. However, until recently, there was not a recommended standard form for the reporting of such measurements. In this study, we explore the use of collision cross section distributions to allow comparisons of IM-MS data for commonly analyzed proteins. We present measurements from seven proteins across three IM-MS configurations, namely, an Agilent 6560 IMQToF, a Waters Synapt G2 possessing a TWIMS cell and a modified Synapt G2 possessing an RF confining linear field drift cell. Mobility measurements were taken using He and N2 as the drift gases. To aid comparability across instruments and best assess the corresponding gas-phase conformational landscapes of the protein "standards", we present the data in the form of averaged CCS distributions. For experiments carried out in N2, CCS values for the most compact ion conformations have an interinstrument variability of ≤3%, and the total CCS distributions are generally similar across platforms. For experiments carried out in He, we observe the total CCS distributions to follow the same trend as observed in N2, while CCS for the most compact ion conformations sampled on the 6560 are systematically smaller by up to 10% than those observed on the G2. The calibration procedure (for TWIMS) yields TWCCS for native-like proteins which are largely similar to those obtained on DTIMS instruments. We collate previously reported values of CCS for these proteins in the form of histograms which bear a remarkable similarity to the CCS distributions, reflecting the conformational heterogeneity of proteins and also how conformer populations can be altered on transfer from solution to the detector. This gives concern for some caution when calibrating sample protein drift times simply with single numeric CCS values.


Asunto(s)
Proteínas/análisis , Espectrometría de Movilidad Iónica , Espectrometría de Masas
4.
Anal Chem ; 92(19): 13084-13091, 2020 10 06.
Artículo en Inglés | MEDLINE | ID: mdl-32668145

RESUMEN

Low molecular weight metabolites are essential for defining the molecular phenotypes of cells. However, spatial metabolomics tools often lack the sensitivity, specify, and spatial resolution to provide comprehensive descriptions of these species in tissue. MALDI imaging mass spectrometry (IMS) of low molecular weight ions is particularly challenging as MALDI matrix clusters are often nominally isobaric with multiple metabolite ions, requiring high resolving power instrumentation or derivatization to circumvent this issue. An alternative to this is to perform ion mobility separation before ion detection, enabling the visualization of metabolites without the interference of matrix ions. Additional difficulties surrounding low weight metabolite visualization include high resolution imaging, while maintaining sufficient ion numbers for broad and representative analysis of the tissue chemical complement. Here, we use MALDI timsTOF IMS to image low molecular weight metabolites at higher spatial resolution than most metabolite MALDI IMS experiments (20 µm) while maintaining broad coverage within the human kidney. We demonstrate that trapped ion mobility spectrometry (TIMS) can resolve matrix peaks from metabolite signal and separate both isobaric and isomeric metabolites with different distributions within the kidney. The added ion mobility data dimension dramatically increased the peak capacity for spatial metabolomics experiments. Through this improved sensitivity, we have found >40 low molecular weight metabolites in human kidney tissue, such as argininic acid, acetylcarnitine, and choline that localize to the cortex, medulla, and renal pelvis, respectively. Future work will involve further exploring metabolomic profiles of human kidneys as a function of age, sex, and race.


Asunto(s)
Acetilcarnitina/metabolismo , Arginina/análogos & derivados , Colina/metabolismo , Riñón/metabolismo , Metabolómica , Acetilcarnitina/análisis , Arginina/análisis , Arginina/metabolismo , Colina/análisis , Humanos , Espectrometría de Movilidad Iónica , Riñón/química , Peso Molecular , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción
5.
Anal Chem ; 92(19): 13290-13297, 2020 10 06.
Artículo en Inglés | MEDLINE | ID: mdl-32808523

RESUMEN

Lipids are a structurally diverse class of molecules with important biological functions including cellular signaling and energy storage. Matrix-assisted laser desorption/ionization (MALDI) imaging mass spectrometry (IMS) allows for direct mapping of biomolecules in tissues. Fully characterizing the structural diversity of lipids remains a challenge due to the presence of isobaric and isomeric species, which greatly complicates data interpretation when only m/z information is available. Integrating ion mobility separations aids in deconvoluting these complex mixtures and addressing the challenges of lipid IMS. Here, we demonstrate that a MALDI quadrupole time-of-flight (Q-TOF) mass spectrometer with trapped ion mobility spectrometry (TIMS) enables a >250% increase in the peak capacity during IMS experiments. MALDI TIMS-MS separation of lipid isomer standards, including sn backbone isomers, acyl chain isomers, and double-bond position and stereoisomers, is demonstrated. As a proof of concept, in situ separation and imaging of lipid isomers with distinct spatial distributions were performed using tissue sections from a whole-body mouse pup.


Asunto(s)
Lipidómica , Lípidos/análisis , Animales , Espectrometría de Movilidad Iónica , Ratones , Ratones Endogámicos C57BL , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción
6.
Anal Chem ; 92(16): 10881-10890, 2020 08 18.
Artículo en Inglés | MEDLINE | ID: mdl-32649184

RESUMEN

The past few years have seen a dramatic increase in applications of native mass and ion mobility spectrometry, especially for the study of proteins and protein complexes. This increase has been catalyzed by the availability of commercial instrumentation capable of carrying out such analyses. As in most fields, however, the software to process the data generated from new instrumentation lags behind. Recently, a number of research groups have started addressing this by developing software, but further improvements are still required in order to realize the full potential of the data sets generated. In this perspective, we describe practical aspects as well as challenges in processing native mass spectrometry (MS) and ion mobility-MS data sets and provide a brief overview of currently available tools. We then set out our vision of future developments that would bring the community together and lead to the development of a common platform to expedite future computational developments, provide standardized processing approaches, and serve as a location for the deposition of data for this emerging field. This perspective has been written by members of the European Cooperation in Science and Technology Action on Native MS and Related Methods for Structural Biology (EU COST Action BM1403) as an introduction to the software tools available in this area. It is intended to serve as an overview for newcomers and to stimulate discussions in the community on further developments in this field, rather than being an in-depth review. Our complementary perspective (http://dx.doi.org/10.1021/acs.analchem.9b05791) focuses on computational approaches used in this field.

7.
Anal Chem ; 92(16): 10872-10880, 2020 08 18.
Artículo en Inglés | MEDLINE | ID: mdl-32667808

RESUMEN

Native mass spectrometry (MS) allows the interrogation of structural aspects of macromolecules in the gas phase, under the premise of having initially maintained their solution-phase noncovalent interactions intact. In the more than 25 years since the first reports, the utility of native MS has become well established in the structural biology community. The experimental and technological advances during this time have been rapid, resulting in dramatic increases in sensitivity, mass range, resolution, and complexity of possible experiments. As experimental methods have improved, there have been accompanying developments in computational approaches for analyzing and exploiting the profusion of MS data in a structural and biophysical context. In this perspective, we consider the computational strategies currently being employed by the community, aspects of best practice, and the challenges that remain to be addressed. Our perspective is based on discussions within the European Cooperation in Science and Technology Action on Native Mass Spectrometry and Related Methods for Structural Biology (EU COST Action BM1403), which involved participants from across Europe and North America. It is intended not as an in-depth review but instead to provide an accessible introduction to and overview of the topic-to inform newcomers to the field and stimulate discussions in the community about addressing existing challenges. Our complementary perspective (http://dx.doi.org/10.1021/acs.analchem.9b05792) focuses on software tools available to help researchers tackle some of the challenges enumerated here.


Asunto(s)
Biofisica/métodos , Biología Computacional/métodos , Espectrometría de Masas/estadística & datos numéricos , Espectrometría de Masas/métodos , Proteínas/análisis
8.
J Am Chem Soc ; 141(12): 4908-4918, 2019 03 27.
Artículo en Inglés | MEDLINE | ID: mdl-30823702

RESUMEN

The global dimensions and amplitudes of conformational fluctuations of intrinsically disordered proteins are governed, in part, by the linear segregation versus clustering of oppositely charged residues within the primary sequence. Ion mobility-mass spectrometry (IM-MS) affords unique advantages for probing the conformational consequences of the linear patterning of oppositely charged residues because it measures and separates proteins electrosprayed from solution on the basis of charge and shape. Here, we use IM-MS to measure the conformational consequences of charge patterning on the C-terminal intrinsically disordered region (p27 IDR) of the cell cycle inhibitory protein p27Kip1. We report the range of charge states and accompanying collisional cross section distributions for wild-type p27 IDR and two variants with identical amino acid compositions, κ14 and κ56, distinguished by the extent of linear mixing versus segregation of oppositely charged residues. Wild-type p27 IDR (κ31) and κ14, where the oppositely charged residues are more evenly distributed, exhibit a broad distribution of charge states. This is concordant with high degrees of conformational heterogeneity in solution. By contrast, κ56 with linear segregation of oppositely charged residues leads to limited conformational heterogeneity and a narrow distribution of charged states. Gas-phase molecular dynamics simulations demonstrate that the interplay between chain solvation and intrachain interactions (self-solvation) leads to conformational distributions that are modulated by salt concentration, with the wild-type sequence showing the most sensitivity to changes in salt concentration. These results suggest that the charge patterning within the wild-type p27 IDR may be optimized to sample both highly solvated and self-solvated conformational states.


Asunto(s)
Proteínas Intrínsecamente Desordenadas/química , Espectrometría de Masas , Inhibidor p27 de las Quinasas Dependientes de la Ciclina/química , Simulación de Dinámica Molecular , Conformación Proteica
9.
J Am Chem Soc ; 141(37): 14463-14479, 2019 09 18.
Artículo en Inglés | MEDLINE | ID: mdl-31403778

RESUMEN

Carbohydrates possess a variety of distinct features with stereochemistry playing a particularly important role in distinguishing their structure and function. Monosaccharide building blocks are defined by a high density of chiral centers. Additionally, the anomericity and regiochemistry of the glycosidic linkages carry important biological information. Any carbohydrate-sequencing method needs to be precise in determining all aspects of this stereodiversity. Recently, several advances have been made in developing fast and precise analytical techniques that have the potential to address the stereochemical complexity of carbohydrates. This perspective seeks to provide an overview of some of these emerging techniques, focusing on those that are based on NMR and MS-hybridized technologies including ion mobility spectrometry and IR spectroscopy.


Asunto(s)
Carbohidratos/química , Secuencia de Carbohidratos , Análisis Espectral/métodos , Relación Estructura-Actividad
10.
Anal Chem ; 91(22): 14552-14560, 2019 11 19.
Artículo en Inglés | MEDLINE | ID: mdl-31593446

RESUMEN

Imaging mass spectrometry (IMS) enables the spatially targeted molecular assessment of biological tissues at cellular resolutions. New developments and technologies are essential for uncovering the molecular drivers of native physiological function and disease. Instrumentation must maximize spatial resolution, throughput, sensitivity, and specificity, because tissue imaging experiments consist of thousands to millions of pixels. Here, we report the development and application of a matrix-assisted laser desorption/ionization (MALDI) trapped ion-mobility spectrometry (TIMS) imaging platform. This prototype MALDI timsTOF instrument is capable of 10 µm spatial resolutions and 20 pixels/s throughput molecular imaging. The MALDI source utilizes a Bruker SmartBeam 3-D laser system that can generate a square burn pattern of <10 × 10 µm at the sample surface. General image performance was assessed using murine kidney and brain tissues and demonstrate that high-spatial-resolution imaging data can be generated rapidly with mass measurement errors <5 ppm and ∼40 000 resolving power. Initial TIMS-based imaging experiments were performed on whole-body mouse pup tissue demonstrating the separation of closely isobaric [PC(32:0) + Na]+ and [PC(34:3) + H]+ (3 mDa mass difference) in the gas phase. We have shown that the MALDI timsTOF platform can maintain reasonable data acquisition rates (>2 pixels/s) while providing the specificity necessary to differentiate components in complex mixtures of lipid adducts. The combination of high-spatial-resolution and throughput imaging capabilities with high-performance TIMS separations provides a uniquely tunable platform to address many challenges associated with advanced molecular imaging applications.


Asunto(s)
Encéfalo/diagnóstico por imagen , Riñón/diagnóstico por imagen , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/métodos , Animales , Lípidos/análisis , Ratones Endogámicos C57BL , Prueba de Estudio Conceptual , Ratas , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/instrumentación
11.
Angew Chem Int Ed Engl ; 58(10): 3114-3118, 2019 03 04.
Artículo en Inglés | MEDLINE | ID: mdl-30570821

RESUMEN

Intrinsically disordered proteins have been reported to undergo disorder-to-order transitions upon binding to their partners in the cell. The extent of the ordering upon binding and the lack of order prior to binding is difficult to visualize with classical structure determination methods. Binding of p27 to the Cdk2/cyclin A complex is accompanied by partial folding of p27 in the KID domain, with the retention of dynamic behavior for function, particularly in the C-terminal half of the protein. Herein, native ion mobility mass spectrometry (IM-MS) is employed to measure the intrinsic dynamic properties of p27, both in isolation and within the trimeric complex with Cdk2/cyclin A. The trimeric Cdk2/cyclin A/p27-KID complex possesses significant structural heterogeneity compared to Cdk2/cyclin A. These findings support the formation of a fuzzy complex in which both the N- and C-termini of p27 interact with Cdk2/cyclin A in multiple, closely associated states.


Asunto(s)
Ciclina A/metabolismo , Quinasa 2 Dependiente de la Ciclina/metabolismo , Inhibidor p27 de las Quinasas Dependientes de la Ciclina/metabolismo , Ciclina A/química , Quinasa 2 Dependiente de la Ciclina/química , Inhibidor p27 de las Quinasas Dependientes de la Ciclina/química , Humanos , Proteínas Intrínsecamente Desordenadas/metabolismo , Espectrometría de Movilidad Iónica , Espectrometría de Masas , Unión Proteica , Conformación Proteica , Pliegue de Proteína , Dominios y Motivos de Interacción de Proteínas , Mapas de Interacción de Proteínas , Multimerización de Proteína
12.
Angew Chem Int Ed Engl ; 57(1): 213-217, 2018 01 02.
Artículo en Inglés | MEDLINE | ID: mdl-29087022

RESUMEN

The early stages of fibril formation are difficult to capture in solution. We use cold-ion spectroscopy to examine an 11-residue peptide derived from the protein transthyretin and clusters of this fibre-forming peptide containing up to five units in the gas phase. For each oligomer, the UV spectra exhibit distinct changes in the electronic environment of aromatic residues in this peptide compared to that of the monomer and in the bulk solution. The UV spectra of the tetra- and pentamer are superimposable but differ significantly from the spectra of the monomer and trimer. Such a spectral evolution suggests that a common structural motif is formed as early as the tetramer. The presence of this stable motif is further supported by the low conformational heterogeneity of the tetra- and pentamer, revealed from their IR spectra. From comparison of the IR-spectra in the gas and condensed phases, we propose putative assignments for the dominant motif in the oligomers.

13.
Anal Chem ; 89(8): 4540-4549, 2017 04 18.
Artículo en Inglés | MEDLINE | ID: mdl-28350444

RESUMEN

The lack of robust, high-throughput, and sensitive analytical strategies that can conclusively map the structure of glycans has significantly hampered progress in fundamental and applied aspects of glycoscience. Resolution of the anomeric α/ß glycan linkage within oligosaccharides remains a particular challenge. Here, we show that "memory" of anomeric configuration is retained following gas-phase glycosidic bond fragmentation during tandem mass spectrometry (MS2). These findings allow for integration of MS2 with ion mobility spectrometry (IM-MS2) and lead to a strategy to distinguish α- and ß-linkages within natural underivatized carbohydrates. We have applied this fragment-based hyphenated MS technology to oligosaccharide standards and to de novo sequencing of purified plant metabolite glycoconjugates, showing that the anomeric signature is also observable in fragments derived from larger glycans. The discovery of the unexpected anomeric memory effect is further supported by IR-MS action spectroscopy and ab initio calculations. Quantum mechanical calculations provide candidate geometries for the distinct anomeric fragment ions, in turn shedding light on gas-phase dissociation mechanisms of glycosidic linkages.

14.
J Am Soc Mass Spectrom ; 34(7): 1305-1314, 2023 Jul 05.
Artículo en Inglés | MEDLINE | ID: mdl-37319264

RESUMEN

The glomerulus is a multicellular functional tissue unit (FTU) of the nephron that is responsible for blood filtration. Each glomerulus contains multiple substructures and cell types that are crucial for their function. To understand normal aging and disease in kidneys, methods for high spatial resolution molecular imaging within these FTUs across whole slide images is required. Here we demonstrate a workflow using microscopy-driven selected sampling to enable 5 µm pixel size matrix-assisted laser desorption/ionization imaging mass spectrometry (MALDI IMS) of all glomeruli within whole slide human kidney tissues. Such high spatial resolution imaging entails large numbers of pixels, increasing the data acquisition times. Automating FTU-specific tissue sampling enables high-resolution analysis of critical tissue structures, while concurrently maintaining throughput. Glomeruli were automatically segmented using coregistered autofluorescence microscopy data, and these segmentations were translated into MALDI IMS measurement regions. This allowed high-throughput acquisition of 268 glomeruli from a single whole slide human kidney tissue section. Unsupervised machine learning methods were used to discover molecular profiles of glomerular subregions and differentiate between healthy and diseased glomeruli. Average spectra for each glomerulus were analyzed using Uniform Manifold Approximation and Projection (UMAP) and k-means clustering, yielding 7 distinct groups of differentiated healthy and diseased glomeruli. Pixel-wise k-means clustering was applied to all glomeruli, showing unique molecular profiles localized to subregions within each glomerulus. Automated microscopy-driven, FTU-targeted acquisition for high spatial resolution molecular imaging maintains high-throughput and enables rapid assessment of whole slide images at cellular resolution and identification of tissue features associated with normal aging and disease.


Asunto(s)
Riñón , Microscopía , Humanos , Riñón/metabolismo , Imagen Molecular/métodos , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/métodos
15.
J Am Soc Mass Spectrom ; 34(5): 905-912, 2023 May 03.
Artículo en Inglés | MEDLINE | ID: mdl-37061946

RESUMEN

Imaging mass spectrometry (IMS) provides untargeted, highly multiplexed maps of molecular distributions in tissue. Ion images are routinely presented as heatmaps and can be overlaid onto complementary microscopy images that provide greater context. However, heatmaps use transparency blending to visualize both images, obscuring subtle quantitative differences and distribution gradients. Here, we developed a contour mapping approach that combines information from IMS ion intensity distributions with that of stained microscopy. As a case study, we applied this approach to imaging data from Staphylococcus aureus-infected murine kidney. In a univariate, or single molecular species, use-case of the contour map representation of IMS data, certain lipids colocalizing with regions of infection were selected using Pearson's correlation coefficient. Contour maps of these lipids overlaid with stained microscopy showed enhanced visualization of lipid distributions and spatial gradients in and around the bacterial abscess as compared to traditional heatmaps. The full IMS data set comprising hundreds of individual ion images was then grouped into a smaller subset of representative patterns using non-negative matrix factorization (NMF). Contour maps of these multivariate NMF images revealed distinct molecular profiles of the major abscesses and surrounding immune response. This contour mapping workflow also enabled a molecular visualization of the transition zone at the host-pathogen interface, providing potential clues about the spatial molecular dynamics beyond what histological staining alone provides. In summary, we developed a new IMS-based contour mapping approach to augment classical stained microscopy images, providing an enhanced and more interpretable visualization of IMS-microscopy multimodal molecular imaging data sets.


Asunto(s)
Riñón , Microscopía , Ratones , Animales , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/métodos , Algoritmos , Lípidos
16.
Artículo en Inglés | MEDLINE | ID: mdl-38186747

RESUMEN

Introduction: Age related macular degeneration (AMD) causes legal blindness worldwide, with few therapeutic targets in early disease and no treatments for 80% of cases. Extracellular deposits, including drusen and subretinal drusenoid deposits (SDD; also called reticular pseudodrusen), disrupt cone and rod photoreceptor functions and strongly confer risk for advanced disease. Due to the differential cholesterol composition of drusen and SDD, lipid transfer and cycling between photoreceptors and support cells are candidate dysregulated pathways leading to deposit formation. The current study explores this hypothesis through a comprehensive lipid compositional analysis of SDD. Methods: Histology and transmission electron microscopy were used to characterize the morphology of SDD. Highly sensitive tools of imaging mass spectrometry (IMS) and nano liquid chromatography tandem mass spectrometry (nLC-MS/MS) in positive and negative ion modes were used to spatially map and identify SDD lipids, respectively. An interpretable supervised machine learning approach was utilized to compare the lipid composition of SDD to regions of uninvolved retina across 1873 IMS features and to automatically discern candidate markers for SDD. Immunohistochemistry (IHC) was used to localize secretory phospholipase A2 group 5 (PLA2G5). Results: Among the 1873 detected features in IMS data, three lipid classes, including lysophosphatidylcholine (LysoPC), lysophosphatidylethanolamine (LysoPE) and lysophosphatidic acid (LysoPA) were observed nearly exclusively in SDD while presumed precursors, including phosphatidylcholine (PC), phosphatidylethanolamine (PE) and phosphatidic acid (PA) lipids were detected in SDD and adjacent photoreceptor outer segments. Molecular signals specific to SDD were found in central retina and elsewhere. IHC results indicated abundant PLA2G5 in photoreceptors and retinal pigment epithelium (RPE). Discussion: The abundance of lysolipids in SDD implicates lipid remodeling or degradation in deposit formation, consistent with ultrastructural evidence of electron dense lipid-containing structures distinct from photoreceptor outer segment disks and immunolocalization of secretory PLA2G5 in photoreceptors and RPE. Further studies are required to understand the role of lipid signals observed in and around SDD.

17.
J Mass Spectrom Adv Clin Lab ; 26: 36-46, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36388058

RESUMEN

Introduction: Although Staphylococcus aureus is the leading cause of biofilm-related infections, the lipidomic distributions within these biofilms is poorly understood. Here, lipidomic mapping of S. aureus biofilm cross-sections was performed to investigate heterogeneity between horizontal biofilm layers. Methods: S. aureus biofilms were grown statically, embedded in a mixture of carboxymethylcellulose/gelatin, and prepared for downstream matrix-assisted laser desorption/ionization imaging mass spectrometry (MALDI IMS). Trapped ion mobility spectrometry (TIMS) was also applied prior to mass analysis. Results: Implementation of TIMS led to a âˆ¼ threefold increase in the number of lipid species detected. Washing biofilm samples with ammonium formate (150 mM) increased signal intensity for some bacterial lipids by as much as tenfold, with minimal disruption of the biofilm structure. MALDI TIMS IMS revealed that most lipids localize primarily to a single biofilm layer, and species from the same lipid class such as cardiolipins CL(57:0) - CL(66:0) display starkly different localizations, exhibiting between 1.5 and 6.3-fold intensity differences between layers (n = 3, p < 0.03). No horizontal layers were observed within biofilms grown anaerobically, and lipids were distributed homogenously. Conclusions: High spatial resolution analysis of S. aureus biofilm cross-sections by MALDI TIMS IMS revealed stark lipidomic heterogeneity between horizontal S. aureus biofilm layers demonstrating that each layer was molecularly distinct. Finally, this workflow uncovered an absence of layers in biofilms grown under anaerobic conditions, possibly indicating that oxygen contributes to the observed heterogeneity under aerobic conditions. Future applications of this workflow to study spatially localized molecular responses to antimicrobials could provide new therapeutic strategies.

18.
Anal Chim Acta ; 1177: 338522, 2021 Sep 08.
Artículo en Inglés | MEDLINE | ID: mdl-34482894

RESUMEN

The search for molecular species that are differentially expressed between biological states is an important step towards discovering promising biomarker candidates. In imaging mass spectrometry (IMS), performing this search manually is often impractical due to the large size and high-dimensionality of IMS datasets. Instead, we propose an interpretable machine learning workflow that automatically identifies biomarker candidates by their mass-to-charge ratios, and that quantitatively estimates their relevance to recognizing a given biological class using Shapley additive explanations (SHAP). The task of biomarker candidate discovery is translated into a feature ranking problem: given a classification model that assigns pixels to different biological classes on the basis of their mass spectra, the molecular species that the model uses as features are ranked in descending order of relative predictive importance such that the top-ranking features have a higher likelihood of being useful biomarkers. Besides providing the user with an experiment-wide measure of a molecular species' biomarker potential, our workflow delivers spatially localized explanations of the classification model's decision-making process in the form of a novel representation called SHAP maps. SHAP maps deliver insight into the spatial specificity of biomarker candidates by highlighting in which regions of the tissue sample each feature provides discriminative information and in which regions it does not. SHAP maps also enable one to determine whether the relationship between a biomarker candidate and a biological state of interest is correlative or anticorrelative. Our automated approach to estimating a molecular species' potential for characterizing a user-provided biological class, combined with the untargeted and multiplexed nature of IMS, allows for the rapid screening of thousands of molecular species and the obtention of a broader biomarker candidate shortlist than would be possible through targeted manual assessment. Our biomarker candidate discovery workflow is demonstrated on mouse-pup and rat kidney case studies.


Asunto(s)
Investigación Biomédica , Aprendizaje Automático , Animales , Pruebas Diagnósticas de Rutina , Espectrometría de Masas , Ratones , Ratas
19.
J Am Soc Mass Spectrom ; 32(10): 2519-2527, 2021 Oct 06.
Artículo en Inglés | MEDLINE | ID: mdl-34435768

RESUMEN

We demonstrate the utility of combining silicon nanopost arrays (NAPA) and trapped ion mobility imaging mass spectrometry (TIMS IMS) for high spatial resolution and specificity mapping of neutral lipid classes in tissue. Ionization of neutral lipid species such as triglycerides (TGs), cholestryl esters (CEs), and hexosylceramides (HexCers) from biological tissues has remained a challenge for imaging applications. NAPA, a matrix-free laser desorption ionization substrate, provides enhanced ionization efficiency for the above-mentioned neutral lipid species, providing complementary lipid coverage to matrix-assisted laser desorption ionization (MALDI). The combination of NAPA and TIMS IMS enables imaging of neutral lipid species at 20 µm spatial resolution while also increasing molecular coverage greater than 2-fold using gas-phase ion mobility separations. This is a significant improvement with respect to sensitivity, specificity, and spatial resolution compared to previously reported imaging studies using NAPA alone. Improved specificity for neutral lipid analysis using TIMS IMS was shown using rat kidney tissue to separate TGs, CEs, HexCers, and phospholipids into distinct ion mobility trendlines. Further, this technology allowed for the separation of isomeric species, including mobility resolved isomers of Cer(d42:2) (m/z 686.585) with distinct spatial localizations measured in rat kidney tissue section.


Asunto(s)
Lípidos/análisis , Imagen Molecular/métodos , Nanoestructuras/química , Silicio/química , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/métodos , Animales , Encéfalo/diagnóstico por imagen , Química Encefálica/fisiología , Isomerismo , Riñón/química , Riñón/diagnóstico por imagen , Lípidos/química , Ratas
20.
STAR Protoc ; 2(3): 100747, 2021 09 17.
Artículo en Inglés | MEDLINE | ID: mdl-34430920

RESUMEN

Here, we describe the preservation and preparation of human kidney tissue for interrogation by histopathology, imaging mass spectrometry, and multiplexed immunofluorescence. Custom image registration and integration techniques are used to create cellular and molecular atlases of this organ system. Through careful optimization, we ensure high-quality and reproducible datasets suitable for cross-patient comparisons that are essential to understanding human health and disease. Moreover, each of these steps can be adapted to other organ systems or diseases, enabling additional atlas efforts.


Asunto(s)
Técnica del Anticuerpo Fluorescente/métodos , Riñón/diagnóstico por imagen , Imagen Multimodal/métodos , Manejo de Especímenes/métodos , Animales , Diagnóstico por Imagen , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Riñón/citología , Espectrometría de Masas/métodos , Análisis de la Célula Individual/métodos , Coloración y Etiquetado/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA