Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 95
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Eur Arch Otorhinolaryngol ; 281(1): 171-179, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37522908

RESUMEN

OBJECTIVE: To analyze and compare the early and late post-operative results of glass ionomer bone cement (GIBC) used in ossiculoplasty. METHODS: The pre-operative, early post-operative (3 months) and late post-operative (> 2 years) audiometric findings, namely the pure-tone average (PTA), bone conduction threshold (BCT) and air-bone gap (ABG) of 40 patients who underwent GIBC ossiculoplasty for different etiologies were analyzed. Early and late results were compared. Also, the patients were grouped in terms of prognostic factors and applied ossiculoplasty techniques, and the results were compared between the groups. RESULTS: There were statistically significant improvements in the pure-tone average and air-bone gap of the patients in the early post-operative period (PTA from 59.60 ± 15.95 to 40.37 ± 17.83 and ABG from 37.12 ± 11.18 to 19.78 ± 10.41, p < 0.001 for both). There were no statistically significant changes in any of the audiometric parameters in the late post-operative period (PTA from 40.37 ± 17.83 to 39.79 ± 17.91, ABG from 19.78 ± 10.41 to 19.32 ± 9.60, BCT from 17.99 ± 12.71 to 18.31 ± 13.99, p > 0.05 for all). Presence of tympanosclerosis was found to be the only prognostic factor to affect the outcome. CONCLUSION: GIBC is a safe and reliable material for ossiculoplasty, which maintains its ability to conduct sound in the long-term follow-up.


Asunto(s)
Prótesis Osicular , Reemplazo Osicular , Humanos , Resultado del Tratamiento , Pérdida Auditiva Conductiva/etiología , Pérdida Auditiva Conductiva/cirugía , Audiometría de Tonos Puros , Estudios Retrospectivos , Timpanoplastia/métodos , Reemplazo Osicular/métodos
2.
Audiol Neurootol ; 28(5): 350-359, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37121229

RESUMEN

INTRODUCTION: Distal renal tubular acidosis (dRTA) is a disease that may develop either primarily or secondarily, resulting from urinary acidification defects in distal tubules. Hearing loss may accompany primary forms of dRTA. This study aims to determine the characteristics of hearing loss due to different gene mutations in patients with dRTA. METHODS: Behavioral and electrophysiological audiological evaluations were performed after otolaryngology examination in 21 patients with clinically diagnosed dRTA. Radiological imaging of the inner ear (n = 9) was conducted and results of genetic analyses using next-generation sequencing method (n = 16) were included. RESULTS: Twenty-one patients with dRTA from 20 unrelated families, aged between 8 months and 33 years (median = 12, interquartile range = 20), participated. All patients with ATP6V1B1 mutations (n = 9) had different degrees of hearing loss. There was one patient with hearing loss in patients with ATP6V0A4 mutations (n = 6). One patient with the WDR72 mutation had normal hearing. Large vestibular aqueduct syndrome (LVAS) was detected in 6 (67%) of 9 patients whose radiological evaluation results were available. CONCLUSIONS: LVAS is common in patients with dRTA and may influence the type and severity of hearing loss in these patients. The possibility of both congenital and late-onset and progressive hearing loss should be considered in dRTA patients. A regular audiological follow-up is essential for the early detection of a possible late-onset or progressive hearing loss in these patients.


Asunto(s)
Acidosis Tubular Renal , Sordera , Pérdida Auditiva Sensorineural , ATPasas de Translocación de Protón Vacuolares , Humanos , Lactante , Pérdida Auditiva Sensorineural/genética , Acidosis Tubular Renal/genética , Acidosis Tubular Renal/diagnóstico , ATPasas de Translocación de Protón Vacuolares/genética , Mutación
3.
Am J Otolaryngol ; 44(1): 103679, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36334418

RESUMEN

OBJECTIVES: After auditory brainstem implant (ABI) surgery, stimulation of certain cranial nerves may result in a non-auditory response, and the electrodes that stimulate these nerves may be deactivated. The goals of this study are to compare the number of active electrodes in the initial activation and the last fitting, to investigate non-auditory response types and their frequency as a result of non-auditory stimulation, to compare the placements of deactivated electrodes as a result of non-auditory stimulation in the initial activation and the last fitting. METHODS: The computer software system was used to perform a retrospective analysis of the fitting data of 69 ABI users who underwent auditory brainstem implant surgery between January 1997 and January 2019. The non-auditory response types, deactive electrodes, and the positioning of the deactive electrodes horizontally and vertically were recorded in these users during the initial activation and the last fitting. RESULTS: There was no statistically significant difference between the number of active electrodes in the initial activation and the last fitting. The proportion of the users with deactive electrodes in the initial activation and the last fitting was not statistically significant different. In the horizontal and vertical placement classification, the placement of the deactive electrodes was not statistically different between initial activation and last fitting. The most common type of non-auditory response was facial nerve stimulation at the initial activation and no auditory perception at the last fitting. According to the difference between the number of active and deactive electrodes in the initial activation and the last fitting, as well as the auditory and non-auditory responses, it was found that the ABI users were statistically different between the initial activation and the last fitting. CONCLUSION: The results of this study show that not only auditory but also non-auditory responses occur in most ABI users. In addition, to the best of our knowledge, this study is the first to examine the frequencies of non-auditory response types, and the placement of the electrodes that cause these responses according to horizontal and vertical classifications.


Asunto(s)
Implantes Auditivos de Tronco Encefálico , Neurofibromatosis 2 , Humanos , Estudios Retrospectivos , Neurofibromatosis 2/cirugía , Estimulación Acústica , Percepción Auditiva , Potenciales Evocados Auditivos del Tronco Encefálico
4.
Eur Arch Otorhinolaryngol ; 280(11): 4903-4913, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37672104

RESUMEN

PURPOSE: This study was aimed at examining the pre- and post-cochlear implant (CI) speech recognition and quality of life results of postlingually deaf adult CI users with a duration of deafness (DoD) > 25 years and determining the maximum DoD limit. METHODS: We enrolled 54 postlingually deaf CI users and divided them into ages ≤ 60 and > 60 years and DoDs ≤ 25 and > 25 years. All participants were evaluated using multisensory measures (auditory and auditory + visual) and open-set Speech Recognition Test (SRT) before CI and 3 years postoperatively. They were administered with The Hearing Handicap Inventory for the Elderly (HHIE) to determine the effects of hearing impairment on daily life. RESULTS: DoD and open-set SRT for auditory and auditory + visual stimuli showed a strong negative linear relationship (r = - 0.506, p < 0.01). Open-set SRT scores of patients with DoD aged ≤ 25 and > 25 years (p < 0.01) differed significantly. The chronological age and HHIE scores in social and emotional subfactors showed a strong negative linear relationship (r = - 0.519, p < 0.01). CONCLUSIONS: The present study showed that the number of years was a major factor determining that postlingual adults with profound hearing loss had hearing loss. The results support CI use as soon as possible in adults to prevent degeneration of the auditory pathways and possible central remodeling. However, auditory rehabilitation outcomes in adults using CI vary widely. Investigating the causes of this variability contributes to audiology.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Sordera , Pérdida Auditiva , Percepción del Habla , Adulto , Anciano , Humanos , Calidad de Vida , Sordera/cirugía , Sordera/rehabilitación , Implantación Coclear/métodos , Pérdida Auditiva/cirugía
5.
Eur Arch Otorhinolaryngol ; 279(8): 3937-3945, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35352145

RESUMEN

PURPOSE: This study aimed to assess the written language skills of children with auditory brainstem implants (ABI). METHODS: In this study, 15 children (from second to eighth grades) with ABI were evaluated for their written language abilities using a written expression skill assessment form. Five different features of written expression points were scored and analyzed, yielding a composite score for written expression skills. RESULTS: This study showed that all children with ABI needed more verbal cues than spontaneously written samples. Moreover, these children used short and simple sentences with limited vocabulary and repeated words and sentences. Furthermore, these children were deficient in writing an introduction, the body, and the conclusion paragraphs and could not write events in a logical sequence. CONCLUSIONS: The written language skills of children with ABI depend on age at implantation, duration of implant use, and additional handicaps. Written expression skills in children with ABI are highly complex skills. The findings highlight the importance of ABI during the critical language development period and the enhancement of training programs for written language skills in children who underwent ABI.


Asunto(s)
Implantes Auditivos de Tronco Encefálico , Sordera , Niño , Sordera/cirugía , Humanos , Desarrollo del Lenguaje
6.
Int J Audiol ; 61(4): 329-335, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-34148495

RESUMEN

OBJECTIVES: To investigate the effects of a number of variables on phoneme discrimination (PD) performance in children with sequential bilateral cochlear implants (SeqBiCIs) and compare PD performance between the 2 implantation sides and between children with bilateral cochlear implants (BiCIs) and their age-matched peers with normal hearing (NH). DESIGN: All participants completed the Auditory Speech Sound Evaluation Phoneme Discrimination Test. STUDY SAMPLE: The sample included 23 children with SeqBiCIs as the study group and 23 with NH as the control group. RESULTS: A significant difference was found between the scores of the two groups under the CI1 and CI2 conditions (p = 0.001), CI1 and BiCI conditions (p = 0.002), and CI2 and BiCI conditions (p = 0.001). PD scores with CI1 significantly depend on age at CI1 and duration of bilateral use. PD scores with CI1 were significant predictors of PD performance with CI2. Duration of BiCI use was a significant predictor of PD scores with BiCI. CONCLUSIONS: The age at CI1 and the duration of bilateral cochlear implant use were found to improve phoneme discrimination performance in children with a sequential bilateral cochlear implant. According to the success of the CI1, it is possible to predict the success of CI2 use.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Percepción del Habla , Niño , Pérdida Auditiva Bilateral/diagnóstico , Pérdida Auditiva Bilateral/cirugía , Pruebas Auditivas , Humanos
7.
Artículo en Inglés | MEDLINE | ID: mdl-34098563

RESUMEN

INTRODUCTION: Children with inner ear malformation (IEM) are at risk of vestibular loss as well as hearing loss. Incomplete partition (IP) anomalies constitute about 41% of all IEMs. This study aimed to investigate the postural control in subjects with the same type of IP on both sides and to compare their results with cochlear implant (CI) users without IEM and healthy peers. METHODS: The study group consists of 17 subjects with the same IP types on both sides and using auditory implants on at least one side, with the following 3 groups: 6 IP-I subjects (mean age 12.28 ± 6.25), 6 IP-II subjects (mean age 12.90 ± 3.23), and 5 IP-III subjects (mean age 6.98 ± 3.10). Six unilateral CI users (mean age 11.38 ± 3.57) with normal inner ear structures were included in the CI control group, and 6 healthy peers (10.20 ± 4.79) were included in the healthy control group. The postural control was measured using the Bruininks-Oseretsky Test of Motor Proficiency Second Edition (BOT-2) balance subtest. All devices were turned off during the balance test. RESULTS: The BOT-2 balance scale scores were observed to be significantly different between the IP-I and healthy control group (medians of balance scores being 3.00 and 16.00, respectively, p < 0.001) and the IP-III and healthy control group (medians of balance scores being 6.60 and 16.00, respectively, p = 0.04). The IP-II group had better balance scores (median = 8.00) than those of the other IP groups, although there were no significant differences between the IP-II and other groups (p > 0.05). CONCLUSION: This study demonstrated that subjects with the same IP type on both sides and with early implantation may differ in terms of their postural control abilities depending on their IP type. Subjects with IP should be regularly followed up by the vestibular assessment and supported by their postural control ability by vestibular rehabilitation.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Sordera , Pérdida Auditiva Sensorineural , Vestíbulo del Laberinto , Adolescente , Niño , Preescolar , Humanos , Equilibrio Postural
8.
Audiol Neurootol ; 26(3): 173-181, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33498058

RESUMEN

BACKGROUND: Young children are able to explore new objects and practice language through the acquisition of motor skills that lead to their overall development. Congenital hearing loss and total vestibular loss may contribute to the delay in speech and motor skill development. OBJECTIVES: To investigate the relationship between motor development performance, speech perception, and language performance in children with auditory brainstem implant (ABI). METHOD: Ten children, aged 4-17 years (mean age 9.76 ± 4.03), fitted with unilateral ABI for at least 2 years due to the presence of labyrinthine aplasia and rudimentary otocyst at least 1 side were included in the study. Several standardized tests, such as Bruininks-Oseretsky Motor Proficiency Test-2 (BOT-2), Children's Auditory Perception Test Battery, Meaningful Auditory Integration Scale (MAIS), and Test of Early Language Development-3, were performed to evaluate their skills of fine motor control, balance, manual dexterity, language, and auditory perception. RESULTS: A significant correlation was established between the BOT-2 manual dexterity and MAIS scores (r = 0.827, p < 0.05) and between the manual dexterity and language skills (for expressive language, r = 0.762, p < 0.05; for receptive language, r = 0.650, p < 0.05). Some of the BOT-2 balance tasks, such as standing on 1 leg on a line with eyes closed, standing on 1 leg on a balance beam with eyes open, standing heel-to-toe on a balance beam, and walking forward heel-to-toe on a line, showed a strong correlation with their receptive and expressive language performance (p < 0.05). CONCLUSION: The current study has indicated that significantly poor manual and balance performances are associated with poor speech perception and language skills in children with ABI. The authors recommend performing a vestibular assessment before and after ABI surgery and the use of a holistic rehabilitation approach, including auditory and vestibular rehabilitation, to support development of the children with ABI.


Asunto(s)
Implantes Auditivos de Tronco Encefálico , Sordera/fisiopatología , Desarrollo del Lenguaje , Lenguaje , Destreza Motora/fisiología , Adolescente , Percepción Auditiva/fisiología , Niño , Preescolar , Sordera/cirugía , Femenino , Humanos , Masculino , Equilibrio Postural/fisiología , Percepción del Habla/fisiología , Resultado del Tratamiento
9.
Int J Audiol ; 60(2): 115-122, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-32885696

RESUMEN

OBJECTIVE: To investigate the postural instability and vestibular functions in children with severe inner ear malformations (IEMs). DESIGN: A prospective case-control study. STUDY SAMPLE: The study group consisted of 10 children using unilateral auditory brainstem implant (ABI) with labyrinthine aplasia or rudimentary otocyst. The age-matched control groups consisted of 10 unilateral cochlear implant (CI) users with normal inner ear structures and 10 healthy peers. All tests were performed to implant users when the implants were off. RESULTS: All median VOR gains in the ABI group (median anterior, lateral, and posterior canal 0.15, 0.05, and 0.05, respectively, for the non-implanted sides) were significantly lower than those of the control groups (median VOR gains ≥ 0.90 in both control groups). There were no oVEMP and cVEMP responses in the study group. The mean BOT-2 balance scores of the ABI (3.70 ± 1.34) group was dramatically lower than those of the CI (9.40 ± 2.88) and healthy control (16.20 ± 4.16, p < 0.001). CONCLUSIONS: The postural instability in children with severe IEMs was higher than those in CI users with normal inner ear structures and healthy peers. The level of deficiency in the labyrinthine was more important for postural stability in children.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Vestíbulo del Laberinto , Estudios de Casos y Controles , Niño , Humanos , Equilibrio Postural
10.
Clin Otolaryngol ; 46(1): 154-160, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-32749771

RESUMEN

BACKGROUND AND OBJECTIVE: Inner ear malformations (IEMs) are common in children with hearing loss. The different types of IEMs form a unique subgroup of cochlear implant (CI) candidates. We aimed to evaluate the auditory perception outcomes of CI in children with different types of IEMs and compare them with CI users without IEMs. METHODS: The study included 274 CI users with and without IEMs as two groups (n = 137, each). Both groups' chronological age at implantation and duration of CI usage was matched (± 8 months). All subjects were evaluated pre-operatively and post-operatively by the Ling's sound test and the auditory perception test battery, which includes the Meaningful Auditory Integration Scale (MAIS), closed-set Pattern Perception Test (PPT) and open-set Sentence Recognition Test (SRT). Besides, children with IEMs were assessed for language development. RESULTS: Progress in the IEMs' group differed according to the type of ear anomaly. CI users with enlarged vestibular aqueduct had the highest scores, while users with common cavity had the lowest. Children with IEMs performed well on the closed-set test while having difficulty with the open-set test. CONCLUSION: Cochlear implantation outcomes are favourable in IEMs' patients with a cochlear nerve visible on magnetic resonance imaging. Our results indicate that it is critical to take the anatomical differences into account during follow-up and rehabilitation programmes. Each CI user should be evaluated according to his or her individual needs.


Asunto(s)
Percepción Auditiva/fisiología , Implantación Coclear , Implantes Cocleares , Oído Interno/anomalías , Trastornos de la Audición/terapia , Desarrollo del Lenguaje , Adolescente , Estudios de Casos y Controles , Niño , Preescolar , Estudios de Cohortes , Femenino , Trastornos de la Audición/diagnóstico , Trastornos de la Audición/etiología , Humanos , Masculino , Resultado del Tratamiento
11.
Clin Otolaryngol ; 45(2): 231-238, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-31854074

RESUMEN

OBJECTIVE: To determine audiological outcomes of children who use a cochlear implant (CI) in one ear and an auditory brainstem implant (ABI) in the contralateral ear. DESIGN: Retrospective case review. SETTING: Tertiary referral hospital. PARTICIPANTS: Twelve children followed with CI and contralateral auditory brainstem implant (ABI) by Hacettepe University Department of Otorhinolaryngology and Audiology in Turkey. All children were diagnosed with different inner ear malformations with cochlear nerve aplasia/hypoplasia. CI was planned in the ear with better sound detection during behavioural testing with inserted ear phones and with better CN as seen on MRI. Due to the limited auditory and speech progress with the cochlear implant, ABI was performed on the contralateral ear in all subjects. MAIN OUTCOME MEASURES: Audiological performance and auditory perception skills of children with cochlear nerve deficiency (CND) who use bimodal electrical stimulation with CI and contralateral ABI. RESULTS: Mean age of the subjects was 84.00 ± 33.94 months. Age at CI surgery and ABI surgery was 25.00 ± 10.98 months and 41.50 ± 16.14 months, respectively. However, hearing thresholds only with CI and only with ABI did not reveal significant difference, and auditory perception scores improved with bimodal stimulation. The MAIS scores were significantly improved from unilateral CI to bimodal stimulation (P = .002). Pattern perception and word recognition scores were significantly higher with the bimodal condition when compared to CI only and ABI only conditions. CONCLUSION: Children with CND showed better performance with CI and contralateral ABI combined. Depending on the audiological and radiological results, bimodal stimulation should be advised for children with CND.


Asunto(s)
Implantes Auditivos de Tronco Encefálico , Percepción Auditiva/fisiología , Implantes Cocleares , Nervio Coclear/anomalías , Oído Interno/anomalías , Pérdida Auditiva Sensorineural/cirugía , Percepción del Habla/fisiología , Preescolar , Nervio Coclear/cirugía , Oído Interno/cirugía , Femenino , Estudios de Seguimiento , Pérdida Auditiva Sensorineural/fisiopatología , Humanos , Masculino , Estudios Retrospectivos , Resultado del Tratamiento
12.
Audiol Neurootol ; 24(3): 147-153, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31307043

RESUMEN

BACKGROUND: Cochlear nerve deficiency is a general term used to describe both cochlear nerve hypoplasia (CNH) and cochlear nerve aplasia. Although these two conditions can have similar results on audiological evaluation, CNH yields more variation in audiological tests. OBJECTIVES: To describe the audiological characteristics of the CNH cases in our series in relation to radiological findings. METHODS: We reviewed the medical charts, audiological findings, and radiological findings on cases with CNH. We included cases with CNH in one ear or both ears. Out of 90 subjects with CNH, we included a total of 40 individuals (21 women and 19 men; 49 ears) in the current study. We reviewed and analyzed the participants' audiological test results according to the radiological findings. RESULTS: Cases with CNH showed variations according to the cochlear structure. There were 13 normal cochleae, 4 with incomplete partition type I, and 32 with cochlear hypoplasia. The accompanying cochlear apertures also showed variation: 17 were normal, 28 stenotic, and 4 aplastic cochlear apertures. The subjects displayed hearing loss ranging from moderate to profound; furthermore, 4 subjects had no response to sound whatsoever. The degree of hearing loss was not statistically significantly different with regard to the presence or absence of cochlear malformation with CNH (p > 0.005). We observed both sensorineural hearing loss and mixed-type hearing loss among the CNH cases. CONCLUSIONS: CNH is the presence of a cochlear nerve that is smaller in diameter than the facial nerve. It can be accompanied with other associated inner ear malformations of different degrees of severity. We observed degrees of hearing loss ranging from moderate to profound.


Asunto(s)
Nervio Coclear/anomalías , Perdida Auditiva Conductiva-Sensorineural Mixta/fisiopatología , Pérdida Auditiva Sensorineural/fisiopatología , Adolescente , Audiometría , Niño , Preescolar , Nervio Coclear/fisiopatología , Femenino , Humanos , Lactante , Masculino , Adulto Joven
13.
Audiol Neurootol ; 24(6): 279-284, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31665723

RESUMEN

BACKGROUND: Cochlear implantation (CI) is an effective treatment option for patients with severe-to-profound hearing loss. When CI first started, it was recommended to wait until at least 4 weeks after the CI surgery for the initial activation because of possible complications. Advances in the surgical techniques and experiences in fitting have made initial activation possible within 24 h. OBJECTIVES: To compare the complaints and complications after early activation between behind-the-ear (BTE) and off-the-ear (OTE) sound processors and to show the impact of early activation on the electrode impedance values. METHOD: CI surgeries performed between March 2013 and July 2018 were retrospectively analyzed from the database. In total, 294 CI users were included in the present study. The impedance measurements were analyzed postoperatively at the initial activation prior to the stimulation, and 4 weeks after the initial activation in the first-month follow-up visit. A customized questionnaire was administered in the first-month follow-up fitting session to caregivers and/or patients who were using CI at least for 6 months. Medical records were also reviewed to identify any postoperative complications. RESULTS: In the early activation group, impedance values were significantly lower than in the control group (p < 0.05) at first fitting. At the first-month follow-up, no significant difference was found between the groups (p > 0.05). The most common side effects were reported to be edema (6.1%) and pain (5.7%) in the early activation group. In patients with OTE sound processors, the rate of side effects such as skin infection, wound swelling, skin hyperemia, and pain was higher than in patients with BTE sound processors; however, a statistical significance was only observed in wound swelling (p = 0.005). Selecting the appropriate magnet was defined as a problem for the OTE sound processors during the initial activation. CONCLUSION: This study revealed that early activation of CI was clinically safe and feasible in patients with BTE sound processors. When using OTE sound processors, the audiologists should be careful during the activation period and inform patients of possible side effects. The first fitting should be delayed for 4 weeks after CI for OTE sound processors. This current study is the first to report this finding with 5 years of experience in a large cohort.


Asunto(s)
Implantación Coclear/métodos , Implantes Cocleares , Sordera/rehabilitación , Ajuste de Prótesis/métodos , Adolescente , Adulto , Anciano , Niño , Preescolar , Edema/epidemiología , Femenino , Humanos , Hiperemia/epidemiología , Lactante , Masculino , Persona de Mediana Edad , Ruido , Dolor Postoperatorio/epidemiología , Complicaciones Posoperatorias , Estudios Retrospectivos , Procesamiento de Señales Asistido por Computador , Percepción del Habla , Infección de la Herida Quirúrgica , Encuestas y Cuestionarios , Adulto Joven
14.
Proc Natl Acad Sci U S A ; 113(21): 5993-8, 2016 May 24.
Artículo en Inglés | MEDLINE | ID: mdl-27162350

RESUMEN

Hair cells of the inner ear, the mechanosensory receptors, convert sound waves into neural signals that are passed to the brain via the auditory nerve. Little is known about the molecular mechanisms that govern the development of hair cell-neuronal connections. We ascertained a family with autosomal recessive deafness associated with a common cavity inner ear malformation and auditory neuropathy. Via whole-exome sequencing, we identified a variant (c.2207G>C, p.R736T) in ROR1 (receptor tyrosine kinase-like orphan receptor 1), cosegregating with deafness in the family and absent in ethnicity-matched controls. ROR1 is a tyrosine kinase-like receptor localized at the plasma membrane. At the cellular level, the mutation prevents the protein from reaching the cellular membrane. In the presence of WNT5A, a known ROR1 ligand, the mutated ROR1 fails to activate NF-κB. Ror1 is expressed in the inner ear during development at embryonic and postnatal stages. We demonstrate that Ror1 mutant mice are severely deaf, with preserved otoacoustic emissions. Anatomically, mutant mice display malformed cochleae. Axons of spiral ganglion neurons show fasciculation defects. Type I neurons show impaired synapses with inner hair cells, and type II neurons display aberrant projections through the cochlear sensory epithelium. We conclude that Ror1 is crucial for spiral ganglion neurons to innervate auditory hair cells. Impairment of ROR1 function largely affects development of the inner ear and hearing in humans and mice.


Asunto(s)
Células Ciliadas Auditivas/metabolismo , Pérdida Auditiva Sensorineural/metabolismo , Mutación , Receptores Huérfanos Similares al Receptor Tirosina Quinasa/metabolismo , Ganglio Espiral de la Cóclea/metabolismo , Animales , Axones/metabolismo , Axones/patología , Línea Celular , Células Ciliadas Auditivas/patología , Pérdida Auditiva Sensorineural/genética , Pérdida Auditiva Sensorineural/patología , Humanos , Ratones , Ratones Mutantes , Receptores Huérfanos Similares al Receptor Tirosina Quinasa/genética , Ganglio Espiral de la Cóclea/patología , Proteína Wnt-5a/genética , Proteína Wnt-5a/metabolismo
16.
Eur Arch Otorhinolaryngol ; 274(9): 3315-3326, 2017 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-28631161

RESUMEN

The objective of the study was to discuss the findings of intraoperative electrically evoked auditory brainstem response (eABR) test results with a recently designed intracochlear test electrode (ITE) in terms of their relation to decisions of cochlear or auditory brainstem implantation. This clinical study was conducted in Hacettepe University, Department of Otolaryngology, Head and Neck Surgery and Department of Audiology. Subjects were selected from inner ear malformation (IEM) database. Eleven subjects with profound sensorineural hearing loss were included in the current study with age range from 1 year 3 months to 4 years 3 months for children with prelingual hearing loss. There was only one 42-year-old post-lingual subject. eABR was recorded with an ITE and intraoperatively with an original cochlear implant (CI) electrode in 11 cases with different IEMs. Findings of eABR with ITE and their relation to the decision for CI or auditory brainstem implant (ABI) are discussed. Positive eABR test results were found to be dependent on close to normal cochlear structures and auditory nerve. The probability of positive result decreases with increasing degree of malformation severity. The prediction value of eABR via ITE on decision for hearing restoration was found to be questionable in this study. The results of eABR with ITE have predictive value on what we will get with the actual CI electrode. ITE appears to stimulate the cochlea like an actual CI. If the eABR is positive, the results are reliable. However, if eABR is negative, the results should be evaluated with preoperative audiological testing and MRI findings.


Asunto(s)
Implantación Auditiva en el Tronco Encefálico , Implantes Auditivos de Tronco Encefálico , Implantación Coclear , Implantes Cocleares , Potenciales Evocados Auditivos del Tronco Encefálico/fisiología , Pérdida Auditiva Sensorineural/terapia , Adulto , Preescolar , Toma de Decisiones Clínicas , Estudios de Cohortes , Femenino , Humanos , Lactante , Masculino
19.
BMC Med Genet ; 16: 9, 2015 Feb 25.
Artículo en Inglés | MEDLINE | ID: mdl-25928534

RESUMEN

BACKGROUND: Mutations in the POU3F4 gene cause X-linked deafness type 3 (DFN3), which is characterized by inner ear anomalies. METHODS: Three Turkish, one Ecuadorian, and one Nigerian families were included based on either inner ear anomalies detected in probands or X-linked family histories. Exome sequencing and/or Sanger sequencing were performed in order to identify the causative DNA variants in these families. RESULTS: Four novel, c.707A>C (p.(Glu236Ala)), c.772delG (p.(Glu258ArgfsX30)), c.902C>T (p.(Pro301Leu)), c.987T>C (p.(Ile308Thr)), and one previously reported mutation c.346delG (p.(Ala116ProfsX26)) in POU3F4, were identified. All mutations identified are predicted to affect the POU-specific or POU homeo domains of the protein and co-segregated with deafness in all families. CONCLUSIONS: Expanding the spectrum of POU3F4 mutations in different populations along with their associated phenotypes provides better understanding of their clinical importance and will be helpful in clinical evaluation and counseling of the affected individuals.


Asunto(s)
Sordera/genética , Enfermedades Genéticas Ligadas al Cromosoma X/genética , Factores del Dominio POU/química , Factores del Dominio POU/genética , Preescolar , Estudios de Cohortes , Sordera/etnología , Femenino , Enfermedades Genéticas Ligadas al Cromosoma X/etnología , Humanos , Masculino , Modelos Moleculares , Linaje , Estructura Terciaria de Proteína
20.
Indian J Otolaryngol Head Neck Surg ; 76(2): 2078-2081, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38566681

RESUMEN

Otitic Hydrocephalus (OH) is one of the most significant life-threatening complications of otological infections. Given their low prevalence and non-specific ear symptoms, this complication requires a high index of suspicion for diagnosis. In this case report, we aim to provide an analysis of OH and describe common clinical signs and symptoms, treatment options, morbidity and mortality.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA