Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 165
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Macromol Rapid Commun ; : e2400512, 2024 Aug 06.
Artículo en Inglés | MEDLINE | ID: mdl-39108065

RESUMEN

The determination of molar masses and their distributions is crucial in polymer synthesis and design. This work presents the current performance and limitations of diffusion-ordered spectroscopy (DOSY) on a low-field (benchtop) NMR spectrometer (at 90 MHz) as an alternative to size exclusion chromatography (SEC) for determining diffusion coefficient distributions (DCDs) and molar mass distributions (MMDs). After optimization for narrowly distributed homopolymers, MMDs obtained with inverse Laplace transformation (ILT) and log-normal distribution are compared with average molar masses obtained with mono- and bi-exponential fits, as well as MMDs obtained from SEC. This approach enables ILT to determine DCDs and MMDs even for bimodal homopolymers with fully spectrally overlapping signals and block copolymers with various chemical compositions, for which chemical composition profiles are determined. The feasibility of low-field diffusion NMR with samples dissolved in non-deuterated solvents is further demonstrated and methods for solvent suppression are discussed.

2.
Magn Reson Chem ; 62(5): 345-360, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-37811556

RESUMEN

Understanding environmental change is challenging and requires molecular-level tools to explain the physicochemical phenomena behind complex processes. Nuclear magnetic resonance (NMR) spectroscopy is a key tool that provides information on both molecular structures and interactions but is underutilized in environmental research because standard "high-field" NMR is financially and physically inaccessible for many and can be overwhelming to those outside of disciplines that routinely use NMR. "Low-field" NMR is an accessible alternative but has reduced sensitivity and increased spectral overlap, which is especially problematic for natural, heterogeneous samples. Therefore, the goal of this study is to investigate and apply innovative experiments that could minimize these challenges and improve low-field NMR analysis of environmental and biological samples. Spectral simplification (JRES, PSYCHE, singlet-only, multiple quantum filters), selective detection (GEMSTONE, DREAMTIME), and heteronuclear (reverse and CH3/CH2/CH-only HSQCs) NMR experiments are tested on samples of increasing complexity (amino acids, spruce resin, and intact water fleas) at-high field (500 MHz) and at low-field (80 MHz). A novel experiment called Doubly Selective HSQC is also introduced, wherein 1H signals are selectively detected based on the 1H and 13C chemical shifts of 1H-13C J-coupled pairs. The most promising approaches identified are the selective techniques (namely for monitoring), and the reverse and CH3-only HSQCs. Findings ultimately demonstrate that low-field NMR holds great potential for biological and environmental research. The multitude of NMR experiments available makes NMR tailorable to nearly any research need, and low-field NMR is therefore anticipated to become a valuable and widely used analytical tool moving forward.


Asunto(s)
Aminoácidos , Espectroscopía de Resonancia Magnética
3.
Magn Reson Chem ; 62(6): 429-438, 2024 06.
Artículo en Inglés | MEDLINE | ID: mdl-38230451

RESUMEN

In recent years there has been a renewed interest in benchtop NMR. Given their lower cost of ownership, smaller footprint, and ease of use, they are especially suited as an educational tool. Here, a new experiment targeted at upper-year undergraduates and first-year graduate students follows the conversion of D-glucose into ethanol at low-field. First, high and low-field data on D-glucose are compared and students learn both the Hz and ppm scales and how J-coupling is field-independent. The students then acquire their own quantitative NMR datasets and perform the quantification using an Electronic Reference To Access In Vivo Concentration (ERETIC) technique. To our knowledge ERETIC is not currently taught at the undergraduate level, but has an advantage in that internal standards are not required; ideal for following processes or with future use in flow-based benchtop monitoring. Using this quantitative data, students can relate a simple chemical process (fermentation) back to more complex topics such as reaction kinetics, bridging the gaps between analytical and physical chemistry. When asked to reflect on the experiment, students had an overwhelmingly positive experience, citing agreement with learning objectives, ease of understanding the protocol, and enjoyment. Each of the respondents recommended this experiment as a learning tool for others. This experiment has been outlined for other instructors to utilize in their own courses across institutions, with the hope that a continued expansion of low-field NMR will increase accessibility and learning opportunities at the undergraduate level.


Asunto(s)
Espectroscopía de Resonancia Magnética , Espectroscopía de Resonancia Magnética/métodos , Etanol/química , Glucosa/análisis , Estudiantes , Humanos , Universidades
4.
Magn Reson Chem ; 62(6): 463-473, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38282484

RESUMEN

Benchtop NMR provides improved accessibility in terms of cost, space, and technical expertise. In turn, this encourages new users into the field of NMR spectroscopy. Unfortunately, many interesting samples in education and research, from beer to whole blood, contain significant amounts of water that require suppression in 1H NMR in order to recover sample information. However, due to the significant reduction in chemical shift dispersion in benchtop NMR systems, the sample signals are much closer to the water resonance compared to those in a corresponding high-field NMR spectrum. Therefore, simply translating solvent suppression experiments intended for high-field NMR instruments to benchtop NMR systems without careful consideration can be problematic. In this study, the effectiveness of several popular water suppression schemes was evaluated for benchtop NMR applications. Emphasis is placed on pulse sequences with no, or few, adjustable parameters making them easy to implement. These fall into two main categories: (1) those based on Pre-SAT including Pre-SAT, PURGE, NOESY-PR, and g-NOESY-PR and (2) those based on binomial inversion including JRS and W5-WATERGATE. Among these schemes, solvent suppression sequences based on Pre-SAT offer a general approach for easy solvent suppression for samples with higher analyte concentrations (sucrose standard and Redbull™). However, for human urine, binomial-like sequences were required. In summary, it is demonstrated that highly efficient water suppression approaches can be implemented on benchtop NMR systems in a simple manner, despite the limited spectral dispersion, further illustrating the potential for widespread implementation of these approaches in education and research.

5.
Sensors (Basel) ; 24(11)2024 May 23.
Artículo en Inglés | MEDLINE | ID: mdl-38894142

RESUMEN

Inline analytics in industrial processes reduce operating costs and production rejection. Dedicated sensors enable inline process monitoring and control tailored to the application of interest. Nuclear Magnetic Resonance is a well-known analytical technique but needs adapting for low-cost, reliable and robust process monitoring. A V-shaped low-field NMR sensor was developed for inline process monitoring and allows non-destructive and non-invasive measurements of materials, for example in a pipe. In this paper, the industrial application is specifically devoted to the quality control of anode slurries in battery production. The characterization of anode slurries was performed with the sensor to determine chemical composition and detect gas inclusions. Additionally, flow properties play an important role in continuous production processes. Therefore, the in- and outflow effects were investigated with the V-shaped NMR sensor as a basis for the future determination of slurry flow fields.

6.
Int J Mol Sci ; 25(3)2024 Feb 05.
Artículo en Inglés | MEDLINE | ID: mdl-38339210

RESUMEN

The respiratory mucus, a viscoelastic gel, effectuates a primary line of the airway defense when operated by the mucociliary clearance. In chronic respiratory diseases (CRDs), such as asthma, chronic obstructive pulmonary disease (COPD), and cystic fibrosis (CF), the mucus is overproduced and its solid content augments, changing its structure and viscoelastic properties and determining a derangement of essential defense mechanisms against opportunistic microbial (virus and bacteria) pathogens. This ensues in damaging of the airways, leading to a vicious cycle of obstruction and infection responsible for the harsh clinical evolution of these CRDs. Here, we review the essential features of normal and pathological mucus (i.e., sputum in CF, COPD, and asthma), i.e., mucin content, structure (mesh size), micro/macro-rheology, pH, and osmotic pressure, ending with the awareness that sputum biomarkers (mucins, inflammatory proteins and peptides, and metabolites) might serve to indicate acute exacerbation and response to therapies. There are some indications that old and novel treatments may change the structure, viscoelastic properties, and biomarker content of sputum; however, a wealth of work is still needed to embrace these measures as correlates of disease severity in association with (or even as substitutes of) pulmonary functional tests.


Asunto(s)
Asma , Fibrosis Quística , Enfermedad Pulmonar Obstructiva Crónica , Trastornos Respiratorios , Humanos , Moco/metabolismo , Trastornos Respiratorios/metabolismo , Sistema Respiratorio/metabolismo , Fibrosis Quística/metabolismo , Asma/metabolismo , Esputo/metabolismo , Enfermedad Pulmonar Obstructiva Crónica/metabolismo , Mucinas/metabolismo
7.
Molecules ; 29(9)2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38731577

RESUMEN

Recently, benchtop nuclear magnetic resonance (NMR) spectrometers utilizing permanent magnets have emerged as versatile tools with applications across various fields, including food and pharmaceuticals. Their efficacy is further enhanced when coupled with chemometric methods. This study presents an innovative approach to leveraging a compact benchtop NMR spectrometer coupled with chemometrics for screening honey-based food supplements adulterated with active pharmaceutical ingredients. Initially, fifty samples seized by French customs were analyzed using a 60 MHz benchtop spectrometer. The investigation unveiled the presence of tadalafil in 37 samples, sildenafil in 5 samples, and a combination of flibanserin with tadalafil in 1 sample. After conducting comprehensive qualitative and quantitative characterization of the samples, we propose a chemometric workflow to provide an efficient screening of honey samples using the NMR dataset. This pipeline, utilizing partial least squares discriminant analysis (PLS-DA) models, enables the classification of samples as either adulterated or non-adulterated, as well as the identification of the presence of tadalafil or sildenafil. Additionally, PLS regression models are employed to predict the quantitative content of these adulterants. Through blind analysis, this workflow allows for the detection and quantification of adulterants in these honey supplements.


Asunto(s)
Suplementos Dietéticos , Miel , Espectroscopía de Resonancia Magnética , Miel/análisis , Suplementos Dietéticos/análisis , Espectroscopía de Resonancia Magnética/métodos , Citrato de Sildenafil/análisis , Flujo de Trabajo , Quimiometría/métodos , Tadalafilo/análisis , Análisis de los Mínimos Cuadrados , Contaminación de Medicamentos/prevención & control , Análisis Discriminante
8.
Sensors (Basel) ; 23(5)2023 Feb 21.
Artículo en Inglés | MEDLINE | ID: mdl-36904592

RESUMEN

Process monitoring and control require dedicated and reliable measures which reflect the status of the process under investigation. Although nuclear magnetic resonance is known to be a versatile analytical technique, it is only seldomly found in process monitoring. Single-sided nuclear magnetic resonance is one well known approach for being applied in process monitoring. The dedicated V-sensor is a recent approach that allows the inline investigation of materials in a pipe non-destructively and non-invasively. An open geometry of the radiofrequency unit is realized using a tailored coil, enabling the sensor to be applied for manifold mobile applications in in-line process monitoring. Stationary liquids were measured, and their properties were integrally quantified as the basis for successful process monitoring. The sensor, in its inline version, is presented along with its characteristics. An exemplary field of application is battery production in terms of anode slurries; thus, the first results on graphite slurries will demonstrate the added value of the sensor in process monitoring.

9.
Chemphyschem ; 23(19): e202200274, 2022 10 06.
Artículo en Inglés | MEDLINE | ID: mdl-35925559

RESUMEN

The reaction of unsaturated substrates with hydrogen gas enriched in the para spin isomer leads to products with a high degree of nuclear singlet spin order. This leads to greatly enhanced NMR signals, with important potential applications such as magnetic resonance imaging (MRI) of metabolic processes. Although parahydrogen-induced polarization has the advantage of being cheap, compact, and mobile, especially when performed in ultralow magnetic fields, efficiency is lost when more than a few protons are involved. This strongly restricts the range of compatible substances. We show that these difficulties may be overcome by a combination of deuteration with the application of a sinusoidally modulated longitudinal field as a well as a transverse rotating magnetic field. We demonstrate a six-fold enhancement in the 13 C hyperpolarization of [1-13 C, 2,3-d2 ]-succinic acid, as compared with standard hyperpolarization methods, applied in the same ultralow field regime.


Asunto(s)
Protones , Ácido Succínico , Deuterio , Hidrógeno/química , Campos Magnéticos , Imagen por Resonancia Magnética/métodos
10.
Magn Reson Chem ; 60(10): 996-1004, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-35899432

RESUMEN

During the oil production and processing stages, the asphaltene precipitation is one of the great operation problems of oil industry. It can precipitate in the formation, tubing, or surface, causing operating problems, such as reduction in oil recovery by changing the reservoir permeability and wettability, clogging of the pipelines, and difficulty in separations process. The quantification of asphaltenes in petroleum by ASTM D6560 standard method is very laborious and use of a larger solvent volume than necessary. The present work proposes the use of time domain nuclear magnetic resonance (TD-NMR) as new methodology to quantify the asphaltene precipitated in crude oil. Three (light, medium, and heavy) crude oils with asphaltenes content of 0.97, 1.88, and 7.00 wt% were mixed with n-heptane in different R (ml of solvent/g of oil) values and analyzed by means of transverse relaxation time (T2 ). According NMR results, the R values enough for complete asphaltene precipitation for the oils A, B, and C were, respectively, equal to 16.50, 23.00, and 39.50 ml g-1 . These outcomes represent a reduction of 58.75%, 42.50%, and 1.25% in the solvent volume per mass of oil for the oil A, B, and C, respectively, compared to the ASTM D6560 method, which imposes 40 ml g-1 . Therefore, it has been shown that TD-NMR can be applied to estimate the amount of asphaltene precipitated in petroleum and have potential to be applied in routine analysis with advantages of saving time and costs.

11.
Magn Reson Chem ; 60(7): 651-658, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-34969169

RESUMEN

Currently, the existence of a gut-bone axis receives massive attention, and while sound premises and indirect proofs exist for the gut-bone axis concept, few studies have provided actual data linking the gut and bone physically. This study aimed to exploit the versatile nature of nuclear magnetic resonance (NMR) to link NMR relaxometry data on bone mineralization with NMR spectroscopic profiling of gut metabolites. For this purpose, sample material was obtained from a 6-week intervention study with ovariectomized (OVX) rats (n = 49) fed with seven different diets varying in calcium content (0.2-6.0 mg/kg) and prebiotic fiber content (0-5.0% w/w). This design ensured a span in (i) calcium available for bone mineralization and (ii) metabolic activity in the gut. After termination of the intervention, longitudinal (T1 ), transverse (T2 ) relaxation, and mechanical bone strength were measured on the excised femur bones. A PLS model with high predictability (Q2 = 0.86, R2 = 0.997) was demonstrated between T2 decay curves and femur mechanical strength. Correlations were established between bone T2 populations and gut short-chain fatty acids. In conclusion, the present dual NMR approach showed strong correlation between T2 relaxation and mechanical strength of the bone, and when metabolic activity in the gut was modulated by inulin, the potential existence of a gut-bone axis was demonstrated.


Asunto(s)
Huesos , Calcio , Animales , Huesos/metabolismo , Calcio/metabolismo , Fémur , Imagen por Resonancia Magnética , Espectroscopía de Resonancia Magnética/métodos , Ratas
12.
Sensors (Basel) ; 22(7)2022 Mar 22.
Artículo en Inglés | MEDLINE | ID: mdl-35408053

RESUMEN

Livestock manure is typically applied to fertilize crops, however the accurate determination of manure nutrient composition through a reliable method is important to optimize manure application rates that maximize crop yields and prevent environmental contamination. Existing laboratory methods can be time consuming, expensive, and generally the results are not provided prior to manure application. In this study, the evaluation of a low-field nuclear magnetic resonance (NMR) sensor designated for manure nutrient prediction was assessed. Twenty dairy manure samples were analyzed for total solid (TS), total nitrogen (TN), ammoniacal nitrogen (NH4-N), and total phosphorus (TP) in a certified laboratory and in parallel using the NMR analyzer. The linear regression of NMR prediction versus lab measurements for TS had an R2 value of 0.86 for samples with TS < 8%, and values of 0.94 and 0.98 for TN and NH4-N, respectively, indicating good correlations between NMR prediction and lab measurements. The TP prediction of NMR for all samples agreed with the lab analysis with R2 greater than 0.87. The intra- and inter-sample variations of TP measured by NMR were significantly larger than other parameters suggesting less robustness in TP prediction. The results of this study indicate low-field NMR is a rapid method that has a potential to be utilized as an alternative to laboratory analysis of manure nutrients, however, further investigation is needed before wide application for on farm analysis.


Asunto(s)
Estiércol , Fósforo , Estudios de Factibilidad , Espectroscopía de Resonancia Magnética , Estiércol/análisis , Nitrógeno/análisis , Nutrientes/análisis , Fósforo/análisis
13.
Molecules ; 27(16)2022 Aug 16.
Artículo en Inglés | MEDLINE | ID: mdl-36014468

RESUMEN

The aim of the study was to investigate how liquid fish oil and microencapsulated oil additives influenced the rheological characteristics and the dynamics of water binding in vacuum-packed (VP) and modified-atmosphere-packed (MAP) poultry sausages during 21-day storage. In contrast to the control sample, the sausages enriched with microencapsulated fish oil (MC) were characterised by the greatest ability to accumulate deformation energy. The elastic properties of all sausage variants increased significantly in the subsequent storage periods, whereas the dynamic viscosity of the samples tended to decrease. This phenomenon was confirmed by the gradual reduction of water activity (Aw) in all sausages in the subsequent storage periods. The packaging method influenced the dynamics of water binding in an oil-additive-form-dependent manner. During the storage of the VP and MAP sausages, in samples with the fish oil additive the T1 value tended to increase while the Aw decreased. The T1 value in the MAP MC sample was similar. The FO additive resulted in greater mobility of both proton fractions in the MAP samples than in the VP samples. There were inverse relationships observed in the MC samples. The NMR tests showed that the VP samples with the MC additive were slightly better quality than the other samples.


Asunto(s)
Aceites de Pescado , Productos de la Carne , Animales , Aceites de Pescado/química , Productos de la Carne/análisis , Aves de Corral , Vacio , Agua
14.
Molecules ; 27(3)2022 Jan 18.
Artículo en Inglés | MEDLINE | ID: mdl-35163848

RESUMEN

Robust and easy-to-use NMR sensor technology is proposed for accurate, on-site determination of fat and protein contents in milk. The two parameters are determined using fast consecutive 1H and 35Cl low-field NMR experiments on milk samples upon the 1:1 addition of a low-cost contrast solution. Reliable and accurate measurements are obtained without tedious calibrations and the need for extensive database information and may readily be conducted by non-experts in production site environments. This enables on-site application at farms or dairies, or use in laboratories harvesting significant reductions in costs and time per analysis as compared to wet-chemistry analysis. The performance is demonstrated for calibration samples, various supermarket milk products, and raw milk samples, of which some were analyzed directly in the milking room. To illustrate the wide application range, the supermarket milk products included both conventionally/organically produced, lactose-free milk, cow's, sheep's and goat's milk, homogenized and unhomogenized milk, and a broad nutrient range (0.1-9% fat, 1-6% protein). Excellent agreement between NMR measurements and reference values, without corrections or changes in calibration for various products and during extensive periods of experiment conduction (4 months) demonstrates the robustness of the procedure and instrumentation. For the raw milk samples, correlations between NMR and IR, NMR and wet-chemistry, as well as IR and wet-chemistry results, show that NMR, in terms of accuracy, compares favorably with the other methods.


Asunto(s)
Grasas/análisis , Espectroscopía de Resonancia Magnética/métodos , Proteínas de la Leche/análisis , Leche/química , Animales , Bovinos , Femenino , Cabras , Ovinos
15.
Molecules ; 28(1)2022 Dec 26.
Artículo en Inglés | MEDLINE | ID: mdl-36615389

RESUMEN

Nuclear magnetic resonance (NMR) techniques are widely used to identify pure substances and probe protein dynamics. Edible oil is a complex mixture composed of hydrocarbons, which have a wide range of molecular size distribution. In this research, low-field NMR (LF-NMR) relaxation characteristic data from various sample oils were analyzed. We also suggest a new method for predicting the size of edible oil molecules using LF-NMR relaxation time. According to the relative molecular mass, the carbon chain length and the transverse relaxation time of different sample oils, combined with oil viscosity and other factors, the relationship between carbon chain length and transverse relaxation time rate was analyzed. Various oils and fats in the mixed fluid were displayed, reflecting the composition information of different oils. We further studied the correlation between the rotation correlation time and the molecular information of oil molecules. The molecular composition of the resulting fluid determines its properties, such as viscosity and phase behavior. The results show that low-field NMR can obtain information on the composition, macromolecular aggregation and molecular dynamics of complex fluids. The measurements of grease in the free-fluid state show that the relaxation time can reflect the intrinsic properties of the fluid. It is shown that the composition characteristics and states of complex fluids can be measured using low-field nuclear magnetic resonance.


Asunto(s)
Simulación de Dinámica Molecular , Aceites , Espectroscopía de Resonancia Magnética/métodos , Imagen por Resonancia Magnética , Hidrocarburos
16.
J Food Sci Technol ; 59(9): 3557-3566, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35875234

RESUMEN

The objective of this study was to determine meat quality distributions and assess hardness distributions in raw and cooked breast fillets with the woody breast (WB) condition, in addition to evaluating the relationship between water properties and WB severity. A total of 90 breast fillets were collected and categorized as normal (NORM), mild (MILD) and severe (SEV). Breast weight, drip loss, compression measurements, cook loss, shear and texture profile analysis (TPA) values were measured for each sample by fillet location (cranial to caudal) and sampling depth (cranial-superficial, cranial-internal, middle-superficial, and middle-internal) in the raw and cooked meat state. Low-field NMR relaxation measurements were also collected for both the raw and cooked fillets. Results indicate that severe WB expressed increased hardness, a higher water content (bound water and free water) and reduced meat quality attributes in raw and cooked meat. Breast fillet hardness and meat quality distributions were unevenly distributed between fillets, compression measurements were higher mainly in the cranial region, and progressively decreased toward the caudal region for both raw and cooked fillets. Shear force and energy values were higher in the cranial region than in the middle region, and TPA values were higher in superficial regions rather than internal portions. Additionally, low-field NMR could be used to predict WB through variation in water properties as thermal processing reduces water distributing abilities in affected fillets.

17.
Chemphyschem ; 22(20): 2128-2137, 2021 10 14.
Artículo en Inglés | MEDLINE | ID: mdl-34324780

RESUMEN

Nuclear magnetic resonance (NMR) spectroscopy usually requires high magnetic fields to create spectral resolution among different proton species. Although proton signals can also be detected at low fields the spectrum exhibits a single line if J-coupling is stronger than chemical shift dispersion. In this work, we demonstrate that the spectra can nevertheless be acquired in this strong-coupling regime using a novel pulse sequence called spin-lock induced crossing (SLIC). This techniques probes energy level crossings induced by a weak spin-locking pulse and produces a unique J-coupling spectrum for most organic molecules. Unlike other forms of low-field J-coupling spectroscopy, our technique does not require the presence of heteronuclei and can be used for most compounds in their native state. We performed SLIC spectroscopy on a number of small molecules at 276 kHz and 20.8 MHZ and show that the simulated SLIC spectra agree well with measurements.

18.
Sens Actuators B Chem ; 337: 129786, 2021 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-33753963

RESUMEN

The rapid and sensitive diagnosis of the highly contagious severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is one of the crucial issues at the outbreak of the ongoing global pandemic that has no valid cure. Here, we propose a SARS-CoV-2 antibody conjugated magnetic graphene quantum dots (GQDs)-based magnetic relaxation switch (MRSw) that specifically recognizes the SARS-CoV-2. The probe of MRSw can be directly mixed with the test sample in a fully sealed vial without sample pretreatment, which largely reduces the testers' risk of infection during the operation. The closed-tube one-step strategy to detect SARS-CoV-2 is developed with home-made ultra-low field nuclear magnetic resonance (ULF NMR) relaxometry working at 118 µT. The magnetic GQDs-based probe shows ultra-high sensitivity in the detection of SARS-CoV-2 due to its high magnetic relaxivity, and the limit of detection is optimized to 248 Particles mL‒1. Meanwhile, the detection time in ULF NMR system is only 2 min, which can significantly improve the efficiency of detection. In short, the magnetic GQDs-based MRSw coupled with ULF NMR can realize a rapid, safe, and sensitive detection of SARS-CoV-2.

19.
Magn Reson Chem ; 59(8): 825-834, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-33754398

RESUMEN

A dedicated nuclear magnetic resonance (NMR) sensor was designed for the analysis of liquids. The magnets are arranged in a V shape, creating a spatially dependent magnetic field in the gap. Measurements of samples with diverse diameters are possible underdefined magnetic field gradients at a given position. The magnet thus combines properties of single sided NMR with high static magnetic field gradients and classical time domain (TD) devices with lower to almost zero gradients. The sensor can easily be adapted to the requirements of the considered investigation; probes can be customized. On the example of lubricants and their aging, the added value and applicability of this sensor in quality control are highlighted in this publication. Relaxation and diffusion were measured by Carr-Purcell-Meiboom-Gill (CPMG) while varying the echo time τe and quantified via numerical modeling. Especially, relaxation shows a high sensitivity towards aging of lubricants such as particulate abrasion and changes in molecular dynamics induced, for example, by additive depletion. The applicability of this NMR sensor in quality control is demonstrated on the example of engine and transmission oils as well as of lubrication greases.

20.
Phytochem Anal ; 32(1): 24-37, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-31989704

RESUMEN

INTRODUCTION: Since a couple of years, low-field (LF) nuclear magnetic resonance (NMR) spectrometers (40-100 MHz) have re-entered the market. They are used for various purposes including analyses of natural products. Similar to high-field instruments (300-1200 MHz), modern LF instruments can measure multiple nuclei and record two-dimensional (2D) NMR spectra. OBJECTIVE: To review the commercial availability as well as applications, advantages, limitations, and prospects of LF-NMR spectrometers for the purpose of natural products analysis. METHOD: Commercial LF instruments were compared. A literature search was performed for articles using and discussing modern LF-NMR. Next, the articles relevant to natural products were read and summarised. RESULTS: Seventy articles were reviewed. Most appeared in 2018 and 2019. Low costs and ease of operation are most often mentioned as reasons for using LF-NMR. CONCLUSION: As the spectral resolution of LF instruments is limited, they are not used for structure elucidation of new natural products but rather applied for quality control (QC), forensics, food and health research, process control and teaching. Chemometric data handling is valuable. LF-NMR is a rapidly developing niche and new instruments keep being introduced.


Asunto(s)
Productos Biológicos , Espectroscopía de Resonancia Magnética
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA