Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Clin Implant Dent Relat Res ; 24(5): 683-695, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-35791805

RESUMEN

BACKGROUND: The fracture of a Morse tapered abutment connection in an osseointegrated implant is one of the most serious mechanical complications, and it is extremely hard to deal with this complication in clinical practice. PURPOSE: The aim of this study was to explore the cumulative mechanical complications focus on abutment of a platform switching Morse taper connection implant system after loading, and to perform a retrospective, approximately 1- to 9-year follow-up study to identify the predisposing factors. MATERIALS AND METHODS: A total of 495 patients with 945 fitted implants were enrolled in this study with a follow-up from January 2012 to January 2020. The data of mechanical complications of the abutment, including abutment fracture (AF) and abutment screw loosening (ASL), and possible causative factors were extracted and evaluated statistically. RESULTS: A total of 25 out of 945 (2.65%) cumulative abutment mechanical complications occurred. AF was the most common complication (n = 13, 1.38%), followed by ASL (n = 12, 1.27%). For AF, gender, type of prosthesis, abutment design, and implant diameter were identified as the causative factors. AF was mostly observed in the single crown of males in molar areas, while ASL was more likely to occur on an angled abutment than on a non-angled abutment. Moreover, the abutment with the positioning index (/X) had a higher incidence of fracture than the abutment without the positioning index (C/). CONCLUSIONS: This study shows that the Morse taper connection is a safe abutment connection. AF occurs more frequently within single crowns in molar area of males, especially with the positioning index (/X), while ASL is more likely to occur in an angled abutment.


Asunto(s)
Implantes Dentales , Coronas , Pilares Dentales , Diseño de Implante Dental-Pilar/efectos adversos , Estudios de Seguimiento , Humanos , Masculino , Estudios Retrospectivos
2.
J Oral Implantol ; 41(2): 139-43, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-23641735

RESUMEN

The biomechanical stability of the implant-abutment connection is critical for the success of implant-supported restorations. This study investigated the effect of a positioning index on the abutment screw preload values of tapered connection implants. Twenty Morse taper implants presenting an internal locking hex received 10 solid and 10 straight screw retained abutments for cemented single-crown restorations. Ten abutments had a positioning index to fit the internal locking hex of the implant (straight), and 10 were locked only by the implant taper (solid). The preload values for each abutment screw after a tightening torque were registered by strain gauges. Prosthetic crowns were placed on each abutment and subjected to mechanical cycling. Detorque forces were applied to each abutment and compared with the initial torque values. Data were statistically analyzed using Kolmogorov-Smirnov and Student t tests. The nonindexed group presented higher initial preload (6.05 N ± 0.95 N) compared with the indexed group (4.88 N ± 0.92 N; P < .05). After cycling, the nonindexed group exhibited less reduction of preload (13.84% ± 6.43%) compared with the indexed group (52.65% ± 14.81%; P < .01). Indexed tapered abutments for single-crown restorations might represent greater biomechanical risk under function.


Asunto(s)
Pilares Dentales , Implantes Dentales , Fenómenos Biomecánicos , Coronas , Diseño de Implante Dental-Pilar , Torque
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA