Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Catheter. cardiovasc. interv ; 93(1): 1-7, Jan. 2019. gráfico, tabela
Artigo em Inglês | SES-SP, SESSP-IDPCPROD, SES-SP | ID: biblio-1024591

RESUMO

BACKGROUND: There is still limited data on the very long term clinical outcomes after ABSORB BRS in daily practice. We sought to evaluate the 3 year-performance of the Absorb bioresorbable vascular scaffolds for the treatment of low/moderate complexity patients enrolled in the ABSORB EXTEND trial. METHODS: ABSORB EXTEND is a prospective, single-arm, open-label clinical study in which 812 patients were enrolled at 56 sites. This study allowed the treatment of lesions ≤28 mm in length and reference vessel diameter of 2.0-3.8 mm (as assessed by on-line QCA). To determine the independent predictors of MACE, a multivariable logistic regression model was built using a stepwise (forward/backward) procedure. RESULTS: Average population age was 61 years and 26.5% had diabetes. Most patients had single target lesion (92.4%). Adequate scaffold deployment (PSP) was achieved in 14.2% of the cases. At three years, the composite endpoints of MACE and ischemia-driven target vessel failure were 9.2% and 10.6%, respectively. The cumulative rate of ARC definite/probable thrombosis was 2.2%, with 1.2% of the cases occurring after the 1st year. Independent predictors of MACE were hypertension and the need for "bail out" stent. CONCLUSION: At three-year follow-up, the use of ABSORB in low/moderate complex PCI was associated with low and acceptable rates of major adverse clinical events, despite the infrequent use of the recommended contemporary scaffold deployment technique. However, scaffold thrombosis rate was higher than reported with current generation of metallic DES. (AU)


Assuntos
Humanos , Trombose , Intervenção Coronária Percutânea , Everolimo
2.
EuroIntervention ; 12(10): 1255-1262, 2016.
Artigo em Inglês | SES-SP, SESSP-IDPCPROD, SES-SP | ID: biblio-1062697

RESUMO

We sought to compare the outcomes of low/moderate complexity patients treated with the Absorb BVS from the ABSORB EXTEND trial with patients treated with the XIENCE everolimus-eluting stent (EES), using propensity score (PS) matching of pooled data from the SPIRIT trials (SPIRIT II, SPIRIT III, SPIRIT IV) and the XIENCE V USA trial...


Assuntos
Serviço Hospitalar de Admissão de Pacientes , Stents
3.
EuroIntervention ; 10(12): 1396-1401, 2015. tab
Artigo em Inglês | SES-SP, SESSP-IDPCPROD, SES-SP | ID: biblio-1062689

RESUMO

Aims: The safety and performance of the Absorb Bioresorbable Vascular Scaffold (Absorb BVS) system(Abbott Vascular, Santa Clara, CA, USA) has been previously established in 131 patients from cohort A andcohort B of the first-in-man ABSORB trial. Following this trial, ABSORB EXTEND was initiated as a globalcontinued access study (outside of the USA) to expand experience with the Absorb BVS system to differentgeographies with broader inclusion criteria to include the treatment of longer lesions and multiple vessels.We report in this manuscript the twelve-month clinical outcomes of the first 512 patients in this population.Methods and results: ABSORB EXTEND is a prospective, single-arm, open-label clinical study whichwill enrol up to 800 patients at up to 100 sites. Included are patients with lesions ≤28 mm in length and referencevessel diameter of 2.0-3.8 mm (as assessed by on-line QCA or IVUS). Treatment of a maximum oftwo de novo native coronary artery lesions is permitted when each lesion is located in a different epicardialvessel. An independent clinical events committee adjudicates all endpoint-related events. At one year, for thefirst 512 patients enrolled in the study, the composite endpoints of ischaemia-driven MACE and ischaemiadriventarget vessel failure were 4.3% and 4.9%, respectively. The cumulative rate of ARC defined definiteand probable scaffold thrombosis for this population was 0.8% at one year.Conclusions: This interim analysis of the ABSORB EXTEND study shows low rates of MACE and scaffoldthrombosis. The study is registered on clinicaltrials.gov (unique identifier NCT01023789).


Assuntos
Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Stents Farmacológicos
4.
EuroIntervention ; 9: 1-6, 2013. tab
Artigo em Inglês | SES-SP, SESSP-IDPCPROD, SES-SP | ID: biblio-1062736

RESUMO

Aims: The safety and performance of the Absorb Bioresorbable Vascular Scaffold (Absorb BVS) system(Abbott Vascular, Santa Clara, CA, USA) has been previously established in 131 patients from cohort A andcohort B of the first-in-man ABSORB trial. Following this trial, ABSORB EXTEND was initiated as a globalcontinued access study (outside of the USA) to expand experience with the Absorb BVS system to differentgeographies with broader inclusion criteria to include the treatment of longer lesions and multiple vessels. Wereport in this manuscript the twelve-month clinical outcomes of the first 512 patients in this population.Methods and results: ABSORB EXTEND is a prospective, single-arm, open-label clinical study whichwill enrol up to 800 patients at up to 100 sites. Included are patients with lesions ≤28 mm in length and referencevessel diameter of 2.0-3.8 mm (as assessed by on-line QCA or IVUS). Treatment of a maximum of twode novo native coronary artery lesions is permitted when each lesion is located in a different epicardial vessel.An independent clinical events committee adjudicates all endpoint-related events. At one year, for the first512 patients enrolled in the study, the composite endpoints of ischaemia-driven MACE and ischaemia-driventarget vessel failure were 4.3% and 4.9%, respectively. The cumulative rate of ARC defined definite andprobable scaffold thrombosis for this population was 0.8% at one year.Conclusions: This interim analysis of the ABSORB EXTEND study shows low rates of MACE and scaffoldthrombosis. The study is registered on clinicaltrials.gov (unique identifier NCT01023789).


Assuntos
Infarto do Miocárdio , Stents , Traumatismos Cardíacos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA