Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 53
Filtrar
1.
Cureus ; 15(3): e36179, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37065363

RESUMO

Background and objective Beta-thalassemia is the most frequent monogenic disease in the world. In beta-thalassemia major (BTM) patients, blood transfusions for severe anemia usually cause iron overload, leading to increased morbidity and mortality. In this study, we aimed to examine the iron overload in the kidneys of BTM patients with a 3 Tesla (3T) MRI device and assess the relationship between iron overload in the liver and heart as well as serum ferritin levels. Methods This was a retrospective study covering the period between November 2014 and March 2015. MRI was performed on 21 patients with BTM who were receiving blood transfusions and chelation therapy. The control group (n=11) included healthy volunteers. A 3T MRI device (Ingenia, Philips, Best, The Netherlands) using a 16-channel phased array SENSE-compatible torso coil was used. Three-point DIXON (mDIXON) sequence and the relaxometry method were employed to measure iron overload. Both kidneys were analyzed via mDIXON sequence for atrophy or variations. Afterward, the images in which renal parenchyma could be distinguished best were selected. Iron deposition was analyzed via the relaxometry method using a unique software (CMR Tools, London, UK). All data were analyzed using IBM SPSS Statistics v.21 (IBM Corp., Armonk, NY). The Kolmogorov-Smirnov test, independent samples t-test, Mann-Whitney U test, and Pearson's and Spearman's rho correlation coefficient were used. A p-value <0.05 was considered statistically significant. Results There was a statistically significant relationship between beta-thalassemia patients who had cardiac iron deposition and those who did not in terms of T2* time (p=0.02). In contrast, there was no similar relationship for liver iron deposition (p>0.05). Renal T2* values were significantly different between the patient and control groups (p=0.029). T2* times were significantly different between patients who had ferritin levels below 2500 ng/ml and those with ferritin levels above 2500 ng/ml (p=0.042). Conclusion Based on our findings, 3T MRI is a safe and reliable tool for screening iron overload in BTM patients as it makes distinguishing between renal parenchyma and renal sinus much easier and as it is more sensitive to iron deposition.

2.
Int J Cardiol Heart Vasc ; 45: 101181, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36793331

RESUMO

Background: To establish the reference values of native T1 and extracellular volume (ECV) in patients without structural heart disease and had a negative adenosine stress 3T cardiac magnetic resonance. Methods: Short-axis T1 mapping images were acquired using a modified Look-Locker inversion recovery technique before and after administration of 0.15 mmol/kg gadobutrol to calculate both native T1 and ECV. To compare the agreement between measurement strategies, regions of interest (ROI) were drawn in all 16 segments then averaged to represent mean global native T1. Additionally, an ROI was drawn in the mid-ventricular septum on the same image to represent the mid-ventricular septal native T1. Results: Fifty-one patients (mean 65 years, 65 % women) were included. Mean global native T1 averaged from all 16 segments and a mid-ventricular septal native T1 were not significantly different (1221.2 ± 35.2 vs 1228.4 ± 43.7 ms, p = 0.21). Men had lower mean global native T1 (1195 ± 29.8 vs 1235.5 ± 29.4 ms, p < 0.001) than women. Both mean global and mid-ventricular septal native T1 were not correlated with age (r = 0.21, p = 0.13 and r = 0.18, p = 0.19, respectively). The calculated ECV was 26.6 ± 2.7 %, which was not influenced by either gender or age. Conclusions: We report the first study to validate the native T1 and ECV reference ranges, factors influencing T1, and the validation across measurement methods in older Asian patients without structural heart disease and had a negative adenosine stress test. These references allow for better detection of abnormal myocardial tissue characteristics in clinical practice.

3.
Arch Esp Urol ; 75(4): 330-338, 2022 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-35818913

RESUMO

INTRODUCTION: The 3-Tesla multiparametric MRI (mpMRI) system represents a diagnostic advance for prostate cancer. Our aim is to demonstrate that the results in 1.5-Tesla mpMRI are not inferior compared to the 3-Tesla for the correct diagnosis of prostate cancer. MATERIAL AND METHODS: Non-inferiority comparative cross-sectional study between fusion-guided prostate biopsy results. 344 patients with clinical suspicion of prostate cancer (elevated PSA and/or suspicious DRE) and mpMRI interpreted and verified by the same radiologists in all cases, 270 in 1.5-Tesla and 74 in 3-Tesla, with at least one lesion PIRADSv2≥ 3. Exclusion criteria were positive biopsy or previous prostate treatment. We consider malignancy as ISUP≥ 1 and significant tumor as ISUP≥ 2. We used Wilcoxon and t-student test (central tendency measures), diagnostic test (gold standard: ISUP of targeted biopsy), Chi2 test and Z-test (comparison of prevalences and 95%CI malignancy and significant tumor according to mpMRI). RESULTS: Median prostate volume 50cc(IQR:33.5) and PSA 6.11ng/ml(IQR:3.39). Mean age 67.4±8.1years. Number of suspi-cious lesions/patient: mpMRI 1.3 (1.5-Tesla) and 1.5 (3-Tesla). No differences were found between mpMRI (homogeneous and comparable samples). 57% (1.5-Tesla) vs 66% (3-Tesla) of targeted biopsies were malignant, and 34%vs38% were significant tumor, with no significant differences. Se, Sp, PPV and NPV for malignancy (1.5-Tesla vs 3-Tesla) were 96%vs90%, 38%vs44%, 67%vs76%, and 86%vs69%, with no significant differences. CONCLUSIONS: There are no significant differences between 1.5-Tesla vs 3-Tesla mpMRI regarding targeted biopsy results. Not to have 3-Tesla mpMRI may not be a limitation to use 1.5-Tesla as a diagnostic test for the better diagnosis of prostate cancer.


Assuntos
Imageamento por Ressonância Magnética Multiparamétrica , Neoplasias da Próstata , Idoso , Estudos Transversais , Humanos , Biópsia Guiada por Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Antígeno Prostático Específico , Neoplasias da Próstata/patologia
4.
Front Neurol ; 13: 857825, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35449515

RESUMO

Importance: Gliomas, tumors of the central nervous system, are classically diagnosed through invasive surgical biopsy and subsequent histopathological study. Innovations in ultra-high field (UHF) imaging, namely 7-Tesla magnetic resonance imaging (7T MRI) are advancing preoperative tumor grading, visualization of intratumoral structures, and appreciation of small brain structures and lesions. Objective: Summarize current innovative uses of UHF imaging techniques in glioma diagnostics and treatment. Methods: A systematic review in accordance with PRISMA guidelines was performed utilizing PubMed. Case reports and series, observational clinical trials, and randomized clinical trials written in English were included. After removing unrelated studies and those with non-human subjects, only those related to 7T MRI were independently reviewed and summarized for data extraction. Some preclinical animal models are briefly described to demonstrate future usages of ultra-high-field imaging. Results: We reviewed 46 studies (43 human and 3 animal models) which reported clinical usages of UHF MRI in the diagnosis and management of gliomas. Current literature generally supports greater resolution imaging from 7T compared to 1.5T or 3T MRI, improving visualization of cerebral microbleeds and white and gray matter, and providing more precise localization for radiotherapy targeting. Additionally, studies found that diffusion or susceptibility-weighted imaging techniques applied to 7T MRI, may be used to predict tumor grade, reveal intratumoral structures such as neovasculature and microstructures like axons, and indicate isocitrate dehydrogenase 1 mutation status in preoperative imaging. Similarly, newer imaging techniques such as magnetic resonance spectroscopy and chemical exchange saturation transfer imaging can be performed on 7T MRI to predict tumor grading and treatment efficacy. Geometrical distortion, a known challenge of 7T MRI, was at a tolerable level in all included studies. Conclusion: UHF imaging has the potential to preoperatively and non-invasively grade gliomas, provide precise therapy target areas, and visualize lesions not seen on conventional MRI.

5.
Jpn J Radiol ; 40(7): 740-748, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35233651

RESUMO

BACKGROUND AND PURPOSE: An accurate histopathological examination with minimal neuronal damage is essential for optimizing treatment strategies of central nervous system lesions. We investigated the feasibility and safety of CT and 3-tesla (3 T) MR-guided freehand brain aspiration biopsies with 18/20-gauge coaxial needles in performing a single imaging unit. MATERIALS AND METHODS: We reviewed CT and 3 T-MR guided freehand aspiration biopsies with 18/20-gauge coaxial needles of 33 patients (11-female and 22-male, mean and median ages: 53 years, min-max 21-79 years) in our tertiary hospital within an 8-year-period were included in this retrospective study. Lesion sizes, diagnostic yield, morbidity, and mortality rates of these biopsies without a scalp incision, surgical burr-hole, or stereotactic-instrumentation/neuro-navigation guidance were assessed. All biopsies were performed with local anesthesia and sedation within a single imaging unit of our radiology department. All free-hand biopsies were done as in-patient procedures and the patients were closely observed after the biopsies. RESULTS: The mean diameter of the lesions was 27 mm (median 25; range 15-46 mm). The diagnostic yield of all free-hand brain biopsies was 88% [one inconclusive result (90%) for 3 T-MR; three inconclusive results (87%) for CT]. There was no major hemorrhage or hematoma, no clinical deterioration, or no infection in our patients on early- and late-phase examinations. Postprocedural minor hemorrhage with a ≤ 2 cm diameter was observed in two patients. The morbidity rate of the study population is 6%. There was no procedure-related infection or mortality in the post-procedural 3 weeks. CONCLUSIONS: Freehand CT or 3 T-MR guided aspiration biopsy was a safe and feasible method for pathological diagnosis of intracranial lesions. Biopsy workflow was simplified with this technique. It could be considered a valuable alternative for stereotaxic biopsies, especially for centers that do not have stereotaxic equipment or experience.


Assuntos
Encéfalo , Tomografia Computadorizada por Raios X , Biópsia por Agulha/métodos , Encéfalo/diagnóstico por imagem , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos
6.
Prog Brain Res ; 268(1): 65-74, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35074095

RESUMO

The most important imaging technology for GKNS continues to be magnetic resonance. The introduction of 3 Tesla machines permits quicker studies with better signal to noise ratio. The more powerful magnet increases the chances of heating the points of contact between patient and frame, but this has been solved with non-conducting nuts. There are several sequences for special functions. CISS studies are optimal for demonstrating cranial nerves in their passage through the subarachnoid space. FLAIR studies facilitate the distinction between CSF and edema due to inflammation. DTI permits the visualization of nerve fiber tracts. This has at least two current applications. In treatment planning of visible lesions, DTI permits a more efficient avoidance of important tracts. In functional work, tracts can be used to improve the definition of functional targets. Non stereotactic MRI can be imported into GammaPlan and co-registered to a non-distorted CT image.


Assuntos
Radiocirurgia , Humanos , Imageamento por Ressonância Magnética/métodos , Radiocirurgia/métodos
7.
Eur J Radiol Open ; 8: 100386, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34877369

RESUMO

PURPOSE: To probe the potential of apparent diffusion coefficient (ADC) to rectify the incidentally detected bone lesion on MRI into benign or malignant lesions. MATERIALS AND METHODS: We retrospectively recruited 44 patients (24 males and 20 females); with 52 bone lesions, who underwent diffusion weighted (DW) imaging using multiple b-values on 3 T MRI. ADC maps were derived and analyzed by two radiologists; blinded to the final diagnosis. The mean ADC values were used for statistical analyses. The diagnosis was deduced by histopathological confirmation; in 32 lesions and strict clinical and imaging follow-up for at least 12 months; in 20 lesions. RESULTS: The mean ADC value (mean±SD) of all malignant tumors (including cartilaginous neoplasms) was [0.92 ± 0.40] × 10-3 mm2/s. This significantly differed from those of both primary benign tumors [1.14 ± 0.24] × 10-3 mm2/s, (p = 0.011), and all non-malignant lesions collectively [1.29 ± 0.44] × 10-3 mm2/s, (p < 0.001). Using mADC value of ≤ 1.1 × 10-3 mm2/s resulted in 86.1% sensitivity and 62.5% specificity for characterizing a lesion as a malignant. The inter-rater reliability was almost perfect (95% CI = 0.954-0.985). CONCLUSION: ADC could be a non-invasive in-vivo surrogate that may be able to discern the incidentally discovered osseous lesions into benign and malignant pathologies and guide further diagnostic workup.

8.
Am J Sports Med ; 49(14): 3887-3897, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34726983

RESUMO

BACKGROUND: The ability to predict meniscus tear reparability based on preoperative magnetic resonance imaging (MRI) is desirable for postoperative planning; however, the accuracy of predictive methods varies widely within the orthopaedic and radiology literature. PURPOSE/HYPOTHESIS: The purpose was to determine if the higher resolution offered by 3-T MRI improves the accuracy of predicting reparability compared with previous investigations using 1.5-T MRI. Our hypothesis was that a higher field strength of 3-T MRI would result in improved reliability assessments and predictions of meniscus tear reparability compared with previous studies utilizing a 1.5-T MRI platform. STUDY DESIGN: Cohort study (diagnosis); Level of evidence, 2. METHODS: A total of 44 patients who underwent meniscus repair were matched by age, sex, and body mass index to 43 patients who underwent partial meniscectomy. Overall, 2 orthopaedic surgeons and 2 musculoskeletal radiologists independently and blindly reviewed the preoperative MRI scans for all 87 patients. For each meniscus tear, reviewers evaluated the following criteria: tear pattern, tear length, tear distance from the meniscocapsular junction, tear thickness, and integrity of any inner meniscal fragment. The resultant data were then applied to 5 different approaches for predicting meniscal reparability. RESULTS: The accuracy for all examined prediction methods was poor, ranging from 55% (3-point method) to 72% (classification tree method) among all reviewers. Interobserver reliability for examined criteria was also poor, with kappa values ranging from 0.07 (inner meniscal fragment status) to 0.40 (tear pattern). CONCLUSION: MRI continues to be a poor predictor of meniscus tear reparability as assessed by arthroscopic criteria, even when using higher resolution 3-T scanners. Interobserver reliability in this setting can be poor, even among experienced clinicians.


Assuntos
Traumatismos do Joelho , Lesões do Menisco Tibial , Artroscopia , Estudos de Coortes , Humanos , Imageamento por Ressonância Magnética , Meniscos Tibiais/diagnóstico por imagem , Meniscos Tibiais/cirurgia , Reprodutibilidade dos Testes , Estudos Retrospectivos , Lesões do Menisco Tibial/diagnóstico por imagem , Lesões do Menisco Tibial/cirurgia
9.
Radiol Oncol ; 54(4): 419-428, 2020 10 21.
Artigo em Inglês | MEDLINE | ID: mdl-33085642

RESUMO

Background To assess different types of adnexal masses as identified by 3T MRI and to discuss the added value of diffusion techniques compared with conventional sequences. Patients and methods 174 women age between 13 and 87 underwent an MRI examination of the pelvis for a period of three years. Patients were examined in two radiology departments - 135 of them on 3 Tesla MRI Siemens Verio and 39 on 3 Tesla MRI Philips Ingenia. At least one adnexal mass was diagnosed in 98 patients and they are subject to this study. Some of them were reviewed retrospectively. Data from patients' history, physical examination and laboratory tests were reviewed as well. Results 124 ovarian masses in 98 females' group of average age 47.2 years were detected. Following the MRI criteria, 59.2% of the cases were considered benign, 30.6% malignant and 10.2% borderline. Out of all masses 58.1% were classified as cystic, 12.9% as solid and 29% as mixed. Оf histologically proven tumors 74.4% were benign and 25.6% were malignant. All of the malignant tumors had restricted diffusion. 64 out of all patients underwent contrast enhancement. (34 there were a subject of contraindications). 39 (61%) of the masses showed contrast enhancement. Conclusions Classifying adnexal masses is essential for the preoperative management of the patients. 3T MRI protocols, in particular diffusion techniques, increase significantly the accuracy of the diagnostic assessment.


Assuntos
Doenças dos Anexos/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Diagnóstico Diferencial , Imagem de Difusão por Ressonância Magnética , Feminino , Humanos , Pessoa de Meia-Idade , Compostos Organometálicos
10.
Neurol India ; 68(2): 413-418, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32415017

RESUMO

OBJECTIVE: In India, few centers are using 1.5 Tesla intraoperative MRI systems. We are using a 3 Tesla iMRI system. We share our initial experience of 3T iMRI in neurosurgical procedures with evaluation of its utility and pitfalls. METHODS: A prospective observational study conducted between August 2017 to July 2018 at Yashoda Hospital, Secunderabad. All patients undergoing iMRI guided resection of intracranial SOL were included. RESULTS: First 100 patients with various intracranial SOLs were included. The mean time required in shifting and image acquisition was 85.6 minutes in first 20 cases which was reduced to 37.4 minutes in next the next cases. Primary GTR was achieved in 44% cases, and residues were detected in 56%, secondary GTR was achieved in 37% cases, and surgery was discontinued in 19%. Maximum residues were detected in intraaxial sols and pituitary macroadenomas. No major iMRI associated complications were seen, minor issues involving transportation and minor contact burns were seen in 4 cases, insignificant anesthetic procedure related complications in 19 cases. CONCLUSION: As per our experience iMRI is an excellent tool to guide and improve the extent of safe resection by 37% in brain tumor surgeries. Good image quality, less time for image acquisition was observed advantages of 3T system. iMRI success depends on multidepartment coordinated teamwork and multiple iterations of the process to smoothen the workflow.


Assuntos
Neoplasias Encefálicas/cirurgia , Imageamento por Ressonância Magnética/métodos , Procedimentos Neurocirúrgicos/métodos , Adenoma/diagnóstico por imagem , Adenoma/cirurgia , Neoplasias Encefálicas/diagnóstico por imagem , Humanos , Cuidados Intraoperatórios/métodos , Neoplasias Meníngeas/diagnóstico por imagem , Neoplasias Meníngeas/cirurgia , Meningioma/diagnóstico por imagem , Meningioma/cirurgia , Neoplasia Residual , Neoplasias Hipofisárias/diagnóstico por imagem , Neoplasias Hipofisárias/cirurgia , Cirurgia Assistida por Computador
11.
Int J Pediatr Otorhinolaryngol ; 133: 110015, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32229365

RESUMO

OBJECTIVES: To demonstrate the safety and feasibility of the first reported case of a 3 Tesla MRI scan in a paediatric 3 Tesla-compatible cochlear implant recipient under general anaesthesia. MATERIALS AND METHODS: A three-year-old child with bilateral optic pathway glioma treated with chemotherapy, who subsequently received a right sided 3 Tesla-compatible cochlear implant for sensorineural hearing loss was examined. The CI device chosen was implanted due to its purported MRI compatibility. Following informed consent and hospital executive approval, the child underwent a 3 Tesla MRI scan to assess for growth of the optic pathway glioma. RESULTS: A 3 Tesla MRI scan of the brain was performed under general anaesthesia. There was expected artefact due to the magnet of the receiver stimulator. There was no malfunction of the implant noted after the procedure, and no neurological or otological complications. The child had five more uneventful 3 Tesla MRI scans of the brain without complications. CONCLUSION: This is the first reported case of a child with a 3 Tesla-compatible cochlear implant undergoing a 3 Tesla MRI scan of the brain under general anaesthesia. Provided manufacturer guidelines are adhered to, 3 Tesla MRI scanning should not be contraindicated in paediatric cochlear implant recipients with a compatible device.


Assuntos
Implantes Cocleares , Imageamento por Ressonância Magnética/métodos , Neoplasias do Sistema Nervoso/diagnóstico por imagem , Glioma do Nervo Óptico/diagnóstico por imagem , Anestesia Geral , Pré-Escolar , Perda Auditiva Neurossensorial/cirurgia , Humanos , Masculino , Neuroimagem/métodos
12.
Gland Surg ; 8(Suppl 3): S208-S215, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31559187

RESUMO

Magnetic resonance imaging (MRI) is the primary imaging tool for the evaluation of pituitary gland pathology. In the last decades, MRI with high-field scanners has become widely used in clinical practice, leading to significant improvements in image quality mainly thanks to a superior spatial resolution and signal intensity. Moreover, several advanced functional MRI sequences have been implemented for pituitary imaging, providing valuable information in diagnostic and presurgical planning of pituitary adenomas. Higher field strength presents however some technical pitfalls to be aware of. The purpose of this article is to review the state of the art of high-resolution MRI of the pituitary gland at 3 Tesla (3T), with a particular focus on the main benefits and the possible limitations of higher field imaging.

13.
J Neurosurg ; : 1-7, 2019 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-31226693

RESUMO

OBJECTIVE: Although rates of postoperative morbidity and mortality have become relatively low in patients undergoing transnasal transsphenoidal surgery (TSS) for pituitary adenoma, cerebrospinal fluid (CSF) fistulas remain a major driver of postoperative morbidity. Persistent CSF fistulas harbor the potential for headache and meningitis. The aim of this study was to investigate whether neural network-based models can reliably identify patients at high risk for intraoperative CSF leakage. METHODS: From a prospective registry, patients who underwent endoscopic TSS for pituitary adenoma were identified. Risk factors for intraoperative CSF leaks were identified using conventional statistical methods. Subsequently, the authors built a prediction model for intraoperative CSF leaks based on deep learning. RESULTS: Intraoperative CSF leaks occurred in 45 (29%) of 154 patients. No risk factors for CSF leaks were identified using conventional statistical methods. The deep neural network-based prediction model classified 88% of patients in the test set correctly, with an area under the curve of 0.84. Sensitivity (83%) and specificity (89%) were high. The positive predictive value was 71%, negative predictive value was 94%, and F1 score was 0.77. High suprasellar Hardy grade, prior surgery, and older age contributed most to the predictions. CONCLUSIONS: The authors trained and internally validated a robust deep neural network-based prediction model that identifies patients at high risk for intraoperative CSF. Machine learning algorithms may predict outcomes and adverse events that were previously nearly unpredictable, thus enabling safer and improved patient care and better patient counseling.

14.
Laryngoscope Investig Otolaryngol ; 4(1): 95-101, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30828625

RESUMO

OBJECTIVE: To assess the feasibility of the clinical use of 3 Tesla and 7 Tesla Magnetic Resonance Imaging for early (cT1) glottic carcinoma, including structural assessment of technical image quality and visibility of the tumor; and if feasible, to correlate MRI findings to routine diagnostics. METHODS: Prospective feasibility study. Twenty patients with primary clinical T1 glottic carcinoma underwent both routine clinical staging and CT. In addition, a 3 T and 7 T MRI protocol, developed for small laryngeal lesions, was performed in a 4-point immobilization mask, using dedicated surface coils. Afterwards, routine endoscopic direct suspension laryngoscopy under general anaesthesia was performed. RESULTS: Only 2 of 7 (29%) of 7 T MRI scans were rated as moderate to good technical image quality. After exclusion of three patients with only mild to moderate dysplasia at the time of MRI, 13 of 17 (76%) of 3 T MRIs were of adequate technical image quality. Tumor visualization was adequate in 8 of 13 (62%) of patients with invasive squamous cell carcinomas. With exclusion of the four MRIs with motion artefacts, the tumor and its boundaries could be adequately seen in 8 of 9 (89%) patients with squamous cell carcinoma versus only one in four (25%) of patients with carcinoma in situ lesions. CONCLUSIONS: 7 Tesla MRI was considered not feasible. 3 Tesla MRI, with adequate patient selection, namely clinical exclusion of patients with a history of claustrophobia and inclusion of only histologically proven invasive squamous cell carcinoma, can be feasible. Especially with further improvement of MR image quality. LEVEL OF EVIDENCE: 2B, prospective diagnostic study.

15.
Arch Gynecol Obstet ; 299(5): 1391-1398, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30719553

RESUMO

PURPOSE: The aim of this study is to analyze the correct staging of primary endometrial cancer (EC) using clinical examination and 3 Tesla (T) magnetic resonance imaging (MRI) results compared to histopathology. METHODS: In this prospective, non-randomized, single-center study, 26 women with biopsy-proven EC were evaluated. All women underwent clinical examination including transvaginal ultrasound (CE/US) and 3T MRI (T2-weighted, diffusion-weighted and dynamic contrast-enhanced sequences) prior to surgery. Spearman's correlation coefficient was employed to analyze the correlation between both staging methods and histopathology and generalized estimation equation analysis to compare their staging results. Main outcome measures are determinations of local tumor extent for EC on CE/US and 3T MRI compared to histopathology (gold standard). RESULTS: Sixteen women had an early-stage pT1a tumor, 10 a locally advanced ≥ pT1b tumor. The early stage was correctly diagnosed at CE/US in 100%, by MRI in 81%. Spearman's correlation coefficient was r = 1.0 (p < 0.001) for correlation of CE/US and histopathology, r = 0.93 (p < 0.001) for correlation of MRI and pathology. A locally advanced tumor stage was exactly diagnosed by MRI in 70% and at CE/US in 50%. CONCLUSIONS: CE/US is sufficient for staging T1a endometrial cancer, while MRI provides higher sensitivity in detecting locally advanced tumors. Based on our results, combining CE/US and 3T MRI in patients with at least suspected deep myometrial invasion offers a more reliable workflow for individual treatment planning.


Assuntos
Neoplasias do Endométrio/diagnóstico por imagem , Neoplasias do Endométrio/diagnóstico , Imageamento por Ressonância Magnética/métodos , Idoso , Neoplasias do Endométrio/patologia , Feminino , Humanos , Pessoa de Meia-Idade , Estudos Prospectivos
16.
J Rheumatol ; 46(7): 676-684, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-30770506

RESUMO

OBJECTIVE: To investigate the correlation between changes in radiological quantitative assessment with changes in clinical and functional assessment from baseline to 3 months in patients with rheumatoid arthritis (RA). METHODS: Twenty-eight patients with RA [methotrexate (MTX) and anti-tumor necrosis factor-α (TNF-α) group with high disease activity (n = 18); and MTX group with low disease activity (n = 10)] underwent assessments at baseline and 3 months: clinical [28-joint count Disease Activity Score (DAS28)], functional [Health Assessment Questionnaire (HAQ) and Michigan Hand Outcome Questionnaire (MHQ)], and imaging-based [3 Tesla magnetic resonance imaging (MRI) and high-resolution peripheral quantitative computed tomography (HR-pQCT)]. MR images were evaluated semiquantitatively [RA MRI scoring (RAMRIS)] and quantitatively for the volume of synovitis and bone marrow edema (BME) lesions. Erosion volumes were measured using HR-pQCT. RESULTS: After 3 months, the anti-TNF-α group demonstrated an improvement in disease activity through DAS28, HAQ, and MHQ. MRI showed significant decreases in synovitis and BME volume for the anti-TNF-α group, and significant increases in the MTX group. HR-pQCT showed significant decreases in bone erosion volume for the anti-TNF-α group, and significant increases in the MTX group. No significance was observed using RAMRIS. Changes in synovitis, BME, and erosion volumes, but not RAMRIS, were significantly correlated with changes in DAS28, HAQ, and MHQ. CONCLUSION: Quantitative measures were more sensitive than semiquantitative grading when evaluating structural and inflammatory changes with treatment, and were associated with patient clinical and functional outcomes. Multimodality imaging with 3T MRI and HR-pQCT may provide promising biomarkers that help determine disease progression and therapy response.


Assuntos
Antirreumáticos/uso terapêutico , Artrite Reumatoide/diagnóstico por imagem , Artrite Reumatoide/tratamento farmacológico , Metotrexato/uso terapêutico , Inibidores do Fator de Necrose Tumoral/uso terapêutico , Adulto , Idoso , Artrite Reumatoide/fisiopatologia , Biomarcadores , Doenças da Medula Óssea/diagnóstico por imagem , Edema/diagnóstico por imagem , Feminino , Seguimentos , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Inquéritos e Questionários , Sinovite/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Resultado do Tratamento , Fator de Necrose Tumoral alfa/antagonistas & inibidores
17.
J Neurosurg ; 132(2): 586-594, 2019 02 22.
Artigo em Inglês | MEDLINE | ID: mdl-30797197

RESUMO

OBJECTIVE: Physicians are more frequently encountering patients who are treated with deep brain stimulation (DBS), yet many MRI centers do not routinely perform MRI in this population. This warrants a safety assessment to improve DBS patients' accessibility to MRI, thereby improving their care while simultaneously providing a new tool for neuromodulation research. METHODS: A phantom simulating a patient with a DBS neuromodulation device (DBS lead model 3387 and IPG Activa PC model 37601) was constructed and used. Temperature changes at the most ventral DBS electrode contacts, implantable pulse generator (IPG) voltages, specific absorption rate (SAR), and B1+rms were recorded during 3-T MRI scanning. Safety data were acquired with a transmit body multi-array receive and quadrature transmit-receive head coil during various pulse sequences, using numerous DBS configurations from "the worst" to "the most common."In addition, 3-T MRI scanning (T1 and fMRI) was performed on 41 patients with fully internalized and active DBS using a quadrature transmit-receive head coil. MR images, neurological examination findings, and stability of the IPG impedances were assessed. RESULTS: In the phantom study, temperature rises at the DBS electrodes were less than 2°C for both coils during 3D SPGR, EPI, DTI, and SWI. Sequences with intense radiofrequency pulses such as T2-weighted sequences may cause higher heating (due to their higher SAR). The IPG did not power off and kept a constant firing rate, and its average voltage output was unchanged. The 41 DBS patients underwent 3-T MRI with no adverse event. CONCLUSIONS: Under the experimental conditions used in this study, 3-T MRI scanning of DBS patients with selected pulse sequences appears to be safe. Generally, T2-weighted sequences (using routine protocols) should be avoided in DBS patients. Complementary 3-T MRI phantom safety data suggest that imaging conditions that are less restrictive than those used in the patients in this study, such as using transmit body multi-array receive coils, may also be safe. Given the interplay between the implanted DBS neuromodulation device and the MRI system, these findings are specific to the experimental conditions in this study.


Assuntos
Estimulação Encefálica Profunda/efeitos adversos , Imageamento por Ressonância Magnética/efeitos adversos , Neuroimagem/métodos , Idoso , Contraindicações de Procedimentos , Estimulação Encefálica Profunda/instrumentação , Impedância Elétrica , Eletrodos Implantados , Feminino , Temperatura Alta , Humanos , Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas
18.
Indian J Radiol Imaging ; 28(3): 285-295, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30319204

RESUMO

OBJECTIVE: The objective of this study was to evaluate intramedullary spinal cord lesions using magnetic resonance spectroscopy and correlate the results with histo-pathological examination (HPE). MATERIALS AND METHODS: Approval for this study was obtained from our institute ethical committee. Overall, 50 patients were recruited (29 male and 21 female), with a maximum age of 53 years and minimum age of 7 years. The mean age group of the study was 33 years. Standard magnetic resonance imaging (MRI) spine was done on a Siemens Skyra 3Tesla MRI scanner. MR Spectroscopy (MRS) was performed for all patients with intramedullary spinal lesions after getting written consent. It was performed using single-voxel method. The change in the metabolite peak was observed in each case and the results were compared with HPE. These collected data were analyzed using SPSS 16.0 version. Descriptive statistics, frequency analysis, and percentage analysis were used for categorical variables; and for continuous variables, mean and standard deviation were analyzed. McNemar's test was used to find the significance between conventional MRI MRS. In the above statistical tool, the probability value 0.05 is considered as significant level. RESULTS: From our study, we observed that by applying routine MRI sequences alone, we could only detect around 58% of the cases correctly. However, when MRS was done along with the conventional MR imaging, the number of cases detected significantly increased to 84%. By applying McNemar's test and comparing the conventional MRI and MRS with HPE, it was found that statistically significant difference exists with P value of 0.007. CONCLUSION: MRS of the spinal cord is a promising tool for research and diagnosis because it can provide additional information complementary to other non-invasive imaging methods. It is an emerging tool and adds new biomarker information for characterization of spinal cord tumors, to differentiate benign from malignant lesions and to prevent unnecessary biopsies and surgeries.

19.
Skeletal Radiol ; 47(12): 1661-1671, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29936558

RESUMO

OBJECTIVE: To determine the threshold signal drop on 3-T chemical shift imaging (CSI), with in-phase (IP) and opposed-phase (OP) sequences, for accurately identifying bone marrow replacement with 100% sensitivity, and determine a clinically useful measurement method for deriving such a threshold. MATERIALS AND METHODS: From a convenience series of 157 MRIs, 36 cases with histologically proven marrow-replacing lesions and 22 sites of red marrow (histologically proven (2) or with minimum 6-month stability) with 3-Tesla CSI were included. Two musculoskeletal radiologists performed two measurement methods (first: multiple algorithmic ROIs at the top, middle, and bottom of lesions (M-ROI); second: an ROI was drawn where there appeared to be the least opposed-phase signal reduction qualitatively/visually (Q-ROI)). Lesional and red marrow signal change (%,[(IP-OP)signal/IP signal]*100) was determined. Statistical analyses included Student's t test, Cohen's kappa, and receiver operator characteristic curve generation. RESULTS: By M-ROI, lesion signal change was - 0.508% (confidence interval (CI) = - 5.537:4.521) and 1.348% (CI = - 3.541:6.311) for readers 1 and 2. By Q-ROI, lesion signal change was - 11.03% (CI = - 17.01:- 5.046) and - 5.657% (CI = - 12.36:1.048) for readers 1 and 2. For all M-ROI and Q-ROI measurement strategies, signal change between lesional tissue and red marrow was significantly different (p < 0.0001). QROI produced the best composite sensitivities and specificities with a maximized Youden index of 0.955-1. A threshold signal drop of 25% with Q-ROI produced at least 100%/86% sensitivity/specificity for both readers for identifying marrow replacement. CONCLUSIONS: For 3-T CSI, a single visually targeted measurement using a 25% threshold is accurate for identifying marrow-replacing lesions.


Assuntos
Doenças da Medula Óssea/diagnóstico por imagem , Neoplasias Ósseas/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Adolescente , Adulto , Idoso , Meios de Contraste , Feminino , Gadolínio DTPA , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Sensibilidade e Especificidade
20.
Arch Orthop Trauma Surg ; 138(5): 699-709, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29582141

RESUMO

BACKGROUND: Various protocols exist for magnetic resonance arthrogram (MRA) of the shoulder, including 3D isotropic scanning and positioning in neutral (2D neutral MRA), or abduction-external-rotation (ABER). HYPOTHESIS: MRA does not improve diagnostic accuracy for labral tears when compared to magnetic resonance imaging (MRI) performed using 3-Tesla (3T) magnets. METHOD: Systematic review of the Cochrane, MEDLINE, and PubMed databases according to PRISMA guidelines. Included studies compared 3T MRI or 3T MRA (index tests) to arthroscopic findings (reference test). Methodological appraisal performed using QUADAS-2. Pooled sensitivity and specificity were calculated. RESULTS: Ten studies including 929 patients were included. Index test bias and applicability were a concern in the majority of studies. The use of arthroscopy as the reference test raised concern of verification bias in all studies. For anterior labral lesions, 3T MRI was less sensitive (0.83 vs. 0.87 p = 0.083) than 3T 2D neutral MRA. Compared to 3T 2D neutral MRA, both 3T 3D Isotropic MRA and 3T ABER MRA significantly improved sensitivity (0.87 vs. 0.95 vs. 0.94). For SLAP lesions, 3T 2D neutral MRA was of similar sensitivity to 3T MRI (0.84 vs. 0.83, p = 0.575), but less specific (0.99 vs. 0.92 p < 0.0001). For posterior labral lesions, 3T 2D neutral MRA had greater sensitivity than 3T 3D Isotropic MRA and 3T MRI (0.90 vs. 0.83 vs. 0.83). CONCLUSIONS: At 3-T, MRA improved sensitivity for diagnosis of anterior and posterior labral lesions, but reduced specificity in diagnosis of SLAP tears. 3T MRA with ABER positioning further improved sensitivity in diagnosis of anterior labral tears. LEVEL OF EVIDENCE: IV.


Assuntos
Artrografia , Cavidade Glenoide/diagnóstico por imagem , Imageamento por Ressonância Magnética , Lesões do Ombro/diagnóstico por imagem , Cavidade Glenoide/lesões , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA