Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Emerg Microbes Infect ; 12(2): 2261561, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37848021

RESUMO

ABSTRACTThe World Health Organization has identified high-priority target product profiles for new TB diagnostics which include rapid biomarker-based, non-sputum-based diagnostic testing, using an easily accessible sample. The Cepheid 3-gene Host Response Fingerstick Blood Prototype Test (MTB-HR) quantifies relative mRNA levels of a 3-gene signature (GBP5, DUSP3, and KLF2) from a whole-blood sample on the GeneXpert platform. The objective of the present study was to evaluate the performance of the MTB-HR to distinguish between active tuberculosis (ATB), latent Mycobacterium tuberculosis infection (LTBI), other pulmonary diseases, and healthy volunteers at a tertiary care centre. Among 653 participants enrolled in this study, 192 were diagnosed as having ATB, and the remaining 461 were classified as non-ATB, including 137 cases of LTBI, 224 cases of other pulmonary diseases, and 100 healthy volunteers. The corresponding AUCs of the MTB-HR in distinguishing untreated ATB from non-ATB, LTBI, other pulmonary diseases, and healthy volunteers were 0.814 (95% CI, 0.760-0.868, sensitivity 76.1%, specificity 71.6%), 0.739 (95% CI, 0.667-0.812, sensitivity 59.7%, specificity 78.1%), 0.825 (95% CI, 0.770-0.880, sensitivity 82.1%, specificity 65.6%), 0.892 (95% CI, 0.839-0.945, sensitivity 76.1%, specificity 88.0%), respectively. When only samples with TAT of less than 1 h were included, the AUC of the MTB-HR in distinguishing untreated ATB from non-ATB was largest, 0.920 (95% CI, 0.822-1.000, sensitivity 81.3%, specificity 87.7%). In conclusion, the MTB-HR assay shows potential as a rapid, blood-based screening and triage test for ATB, especially for untreated ATB, with the advantage of increased diagnostic yield since blood is more readily available.


Assuntos
Tuberculose Latente , Pneumopatias , Mycobacterium tuberculosis , Tuberculose , Humanos , Sensibilidade e Especificidade , Tuberculose/microbiologia , Tuberculose Latente/diagnóstico , Testes Hematológicos , Mycobacterium tuberculosis/genética
2.
Adv Ther ; 36(4): 916-922, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30778908

RESUMO

INTRODUCTION: Determination of circulating prostate specific antigen (PSA) is commonly used in the diagnosis and treatment monitoring of prostate cancer [1]. Presently, PSA testing is performed in centralized laboratories, which is associated with prolonged time between venipuncture and the PSA value being available. In this prospective study, we present a new and rapid test system for the quantitative determination of PSA levels from finger-stick blood. METHODS: The Claros1® analyzer is a rapid microfluidics-based point-of-care system for quantitative PSA analysis from 10-µl finger-stick blood that requires only 10 min for testing. Total PSA concentrations by the Claros system in 100 consecutive asymptomatic men (median age 57 years, range 44-81 years) were compared with two commercially available, commonly used PSA assays (Abbott and Elecsys by Roche) performed by a reference laboratory. RESULTS: Eighty-six percent of finger-stick blood-borne probes from 100 men were evaluable for PSA testing by the Claros1® analyzer system. In 13/14 cases the expiry date of the microfluid cassettes of the Claros system was exceeded and one blood puncture was performed inadequately. The correlations between the Claros results and OPKO-Abbott and OPKO-Roche assay results were high, with R2 values of 0.982 and 0.985, respectively. The R2 value for the Roche-Abbott correlation was 0.991 with a slope value of 1.160. Prostate cancer was diagnosed in seven cases, with a median PSA of 1.8 ng/ml in the Claros group compared to 1.75 ng/ml and 2.1 ng/ml in the Abbott and Roche groups, respectively. CONCLUSION: The Claros1® PSA assay combines the advantages of rapid, accurate detection with a low required sample volume, allowing the analysis to be performed using finger-stick blood. Provided that further analysis proves the reproducibility of the test, it may help to reduce the number of office visits, thus decreasing costs to the health care system.


Assuntos
Coleta de Amostras Sanguíneas/métodos , Microfluídica/métodos , Sistemas Automatizados de Assistência Junto ao Leito , Antígeno Prostático Específico , Neoplasias da Próstata , Redução de Custos , Testes Hematológicos/economia , Testes Hematológicos/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Antígeno Prostático Específico/análise , Antígeno Prostático Específico/sangue , Neoplasias da Próstata/sangue , Neoplasias da Próstata/diagnóstico , Reprodutibilidade dos Testes
3.
Artigo em Inglês | MEDLINE | ID: mdl-24636839

RESUMO

A new procedure is described for the visible-range spectrophotometric analysis of glutathione (GSH) in microvolumes of blood (as low as 0.5 µL) collected by fingerstick. Samples are diluted 1 to 300 (v/v) in a stabilizing solution, followed by determination of haemoglobin concentration and by acid deproteination. GSH is then measured in the clear supernatant by colorimetry using DTNB, i.e., 5,5'-dithio-bis(2-nitrobenzoic acid), in aqueous solution at pH 7.8. The DTNB reagent is prepared and kept at pH 6.2 until just prior its addition, thus avoiding spontaneous decomposition of the reagent. The assay is rapid, easy to adapt to large-scale studies and it avoids artefactual oxidation of GSH, a common methodological shortcoming. The method is precise with 1.7 to 3.4% intra-day relative standard deviation (RSD) and 2.2 to 4.2% inter-day RSD, and accurate with -1.4% to 2.3% intra-day relative error (RE) and -2.8% to 1.6% inter-day RE. GSH is recovered by 97.5 to 100% at all tested concentrations. The new colorimetric micro-method was validated by a reliable previously reported HPLC method. The procedure is suitable for minimally invasive investigation of oxidative stress in peripheral blood.


Assuntos
Glutationa/sangue , Espectrofotometria/métodos , Adulto , Cromatografia Líquida de Alta Pressão , Colorimetria/economia , Colorimetria/métodos , Ácido Ditionitrobenzoico/química , Feminino , Humanos , Indicadores e Reagentes , Limite de Detecção , Masculino , Oxirredução , Estresse Oxidativo , Tamanho da Amostra , Espectrofotometria/economia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA