Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 464
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
Sci Rep ; 14(1): 9515, 2024 04 25.
Artigo em Inglês | MEDLINE | ID: mdl-38664464

RESUMO

Stroke, a major global health concern often rooted in cardiac dynamics, demands precise risk evaluation for targeted intervention. Current risk models, like the CHA 2 DS 2 -VASc score, often lack the granularity required for personalized predictions. In this study, we present a nuanced and thorough stroke risk assessment by integrating functional insights from cardiac magnetic resonance (CMR) with patient-specific computational fluid dynamics (CFD) simulations. Our cohort, evenly split between control and stroke groups, comprises eight patients. Utilizing CINE CMR, we compute kinematic features, revealing smaller left atrial volumes for stroke patients. The incorporation of patient-specific atrial displacement into our hemodynamic simulations unveils the influence of atrial compliance on the flow fields, emphasizing the importance of LA motion in CFD simulations and challenging the conventional rigid wall assumption in hemodynamics models. Standardizing hemodynamic features with functional metrics enhances the differentiation between stroke and control cases. While standalone assessments provide limited clarity, the synergistic fusion of CMR-derived functional data and patient-informed CFD simulations offers a personalized and mechanistic understanding, distinctly segregating stroke from control cases. Specifically, our investigation reveals a crucial clinical insight: normalizing hemodynamic features based on ejection fraction fails to differentiate between stroke and control patients. Differently, when normalized with stroke volume, a clear and clinically significant distinction emerges and this holds true for both the left atrium and its appendage, providing valuable implications for precise stroke risk assessment in clinical settings. This work introduces a novel framework for seamlessly integrating hemodynamic and functional metrics, laying the groundwork for improved predictive models, and highlighting the significance of motion-informed, personalized risk assessments.


Assuntos
Átrios do Coração , Hemodinâmica , Hidrodinâmica , Acidente Vascular Cerebral , Humanos , Acidente Vascular Cerebral/fisiopatologia , Feminino , Masculino , Átrios do Coração/fisiopatologia , Átrios do Coração/diagnóstico por imagem , Pessoa de Meia-Idade , Medição de Risco/métodos , Idoso , Simulação por Computador , Modelos Cardiovasculares , Imagem Cinética por Ressonância Magnética/métodos
2.
Strahlenther Onkol ; 200(5): 418-424, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38488899

RESUMO

PURPOSE: This study aimed to assess the margin for the planning target volume (PTV) using the Van Herk formula. We then validated the proposed margin by real-time magnetic resonance imaging (MRI). METHODS: An analysis of cone-beam computed tomography (CBCT) data from early glottic cancer patients was performed to evaluate organ motion. Deformed clinical target volumes (CTV) after rigid registration were acquired using the Velocity program (Varian Medical Systems, Palo Alto, CA, USA). Systematic (Σ) and random errors (σ) were evaluated. The margin for the PTV was defined as 2.5 Σ + 0.7 σ according to the Van Herk formula. To validate this margin, we accrued healthy volunteers. Sagittal real-time cine MRI was conducted using the ViewRay system (ViewRay Inc., Oakwood Village, OH, USA). Within the obtained sagittal images, the vocal cord was delineated. The movement of the vocal cord was summed up and considered as the internal target volume (ITV). We then assessed the degree of overlap between the ITV and the PTV (vocal cord plus margins) by calculating the volume overlap ratio, represented as (ITV∩PTV)/ITV. RESULTS: CBCTs of 17 early glottic patients were analyzed. Σ and σ were 0.55 and 0.57 for left-right (LR), 0.70 and 0.60 for anterior-posterior (AP), and 1.84 and 1.04 for superior-inferior (SI), respectively. The calculated margin was 1.8 mm (LR), 2.2 mm (AP), and 5.3 mm (SI). Four healthy volunteers participated for validation. A margin of 3 mm (AP) and 5 mm (SI) was applied to the vocal cord as the PTV. The average volume overlap ratio between ITV and PTV was 0.92 (range 0.85-0.99) without swallowing and 0.77 (range 0.70-0.88) with swallowing. CONCLUSION: By evaluating organ motion by using CBCT, the margin was 1.8 (LR), 2.2 (AP), and 5.3 mm (SI). The margin acquired using CBCT fitted well in real-time cine MRI. Given that swallowing during radiotherapy can result in a substantial displacement, it is crucial to consider strategies aimed at minimizing swallowing and related motion.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Glote , Neoplasias Laríngeas , Imagem Cinética por Ressonância Magnética , Humanos , Tomografia Computadorizada de Feixe Cônico/métodos , Imagem Cinética por Ressonância Magnética/métodos , Glote/diagnóstico por imagem , Masculino , Neoplasias Laríngeas/diagnóstico por imagem , Neoplasias Laríngeas/radioterapia , Pessoa de Meia-Idade , Feminino , Adulto , Idoso , Movimentos dos Órgãos , Sistemas Computacionais , Planejamento da Radioterapia Assistida por Computador/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
3.
Eur J Radiol ; 174: 111386, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38447431

RESUMO

PURPOSE: Studies have shown the incremental value of strain imaging in various cardiac diseases. However, reproducibility and generalizability has remained an issue of concern. To overcome this, simplified algorithms such as rapid atrioventricular strains have been proposed. This multicenter study aimed to assess the reproducibility of rapid strains in a real-world setting and identify potential predictors for higher interobserver variation. METHODS: A total of 4 sites retrospectively identified 80 patients and 80 healthy controls who had undergone cardiac magnetic resonance imaging (CMR) at their respective centers using locally available scanners with respective field strengths and imaging protocols. Strain and volumetric parameters were measured at each site and then independently re-evaluated by a blinded core lab. Intraclass correlation coefficients (ICC) and Bland-Altman plots were used to assess inter-observer agreement. In addition, backward multiple linear regression analysis was performed to identify predictors for higher inter-observer variation. RESULTS: There was excellent agreement between sites in feature-tracking and rapid strain values (ICC ≥ 0.96). Bland-Altman plots showed no significant bias. Bi-atrial feature-tracking and rapid strains showed equally excellent agreement (ICC ≥ 0.96) but broader limits of agreement (≤18.0 % vs. ≤3.5 %). Regression analysis showed that higher field strength and lower temporal resolution (>30 ms) independently predicted reduced interobserver agreement for bi-atrial strain parameters (ß = 0.38, p = 0.02 for field strength and ß = 0.34, p = 0.02 for temporal resolution). CONCLUSION: Simplified rapid left ventricular and bi-atrial strain parameters can be reliably applied in a real-world multicenter setting. Due to the results of the regression analysis, a minimum temporal resolution of 30 ms is recommended when assessing atrial deformation.


Assuntos
Imagem Cinética por Ressonância Magnética , Imageamento por Ressonância Magnética , Humanos , Estudos Retrospectivos , Reprodutibilidade dos Testes , Imagem Cinética por Ressonância Magnética/métodos , Átrios do Coração , Variações Dependentes do Observador , Função Ventricular Esquerda
4.
Sci Rep ; 14(1): 3754, 2024 02 14.
Artigo em Inglês | MEDLINE | ID: mdl-38355969

RESUMO

In recent years, a variety of deep learning networks for cardiac MRI (CMR) segmentation have been developed and analyzed. However, nearly all of them are focused on cine CMR under breathold. In this work, accuracy of deep learning methods is assessed for volumetric analysis (via segmentation) of the left ventricle in real-time free-breathing CMR at rest and under exercise stress. Data from healthy volunteers (n = 15) for cine and real-time free-breathing CMR at rest and under exercise stress were analyzed retrospectively. Exercise stress was performed using an ergometer in the supine position. Segmentations of two deep learning methods, a commercially available technique (comDL) and an openly available network (nnU-Net), were compared to a reference model created via the manual correction of segmentations obtained with comDL. Segmentations of left ventricular endocardium (LV), left ventricular myocardium (MYO), and right ventricle (RV) are compared for both end-systolic and end-diastolic phases and analyzed with Dice's coefficient. The volumetric analysis includes the cardiac function parameters LV end-diastolic volume (EDV), LV end-systolic volume (ESV), and LV ejection fraction (EF), evaluated with respect to both absolute and relative differences. For cine CMR, nnU-Net and comDL achieve Dice's coefficients above 0.95 for LV and 0.9 for MYO, and RV. For real-time CMR, the accuracy of nnU-Net exceeds that of comDL overall. For real-time CMR at rest, nnU-Net achieves Dice's coefficients of 0.94 for LV, 0.89 for MYO, and 0.90 for RV and the mean absolute differences between nnU-Net and the reference are 2.9 mL for EDV, 3.5 mL for ESV, and 2.6% for EF. For real-time CMR under exercise stress, nnU-Net achieves Dice's coefficients of 0.92 for LV, 0.85 for MYO, and 0.83 for RV and the mean absolute differences between nnU-Net and reference are 11.4 mL for EDV, 2.9 mL for ESV, and 3.6% for EF. Deep learning methods designed or trained for cine CMR segmentation can perform well on real-time CMR. For real-time free-breathing CMR at rest, the performance of deep learning methods is comparable to inter-observer variability in cine CMR and is usable for fully automatic segmentation. For real-time CMR under exercise stress, the performance of nnU-Net could promise a higher degree of automation in the future.


Assuntos
Aprendizado Profundo , Função Ventricular Esquerda , Humanos , Volume Sistólico , Imagem Cinética por Ressonância Magnética/métodos , Estudos Retrospectivos , Imageamento por Ressonância Magnética/métodos , Ventrículos do Coração , Reprodutibilidade dos Testes
5.
Phys Med Biol ; 69(4)2024 Jan 03.
Artigo em Inglês | MEDLINE | ID: mdl-38232395

RESUMO

Objective. The bowel is an important organ at risk for toxicity during pelvic and abdominal radiotherapy. Identifying regions of high and low bowel motion with MRI during radiotherapy may help to understand the development of bowel toxicity, but the acquisition time of MRI is rather long. The aim of this study is to retrospectively evaluate the precision of bowel motion quantification and to estimate the minimum MRI acquisition time.Approach. We included 22 gynaecologic cancer patients receiving definitive radiotherapy with curative intent. The 10 min pre-treatment 3D cine-MRI scan consisted of 160 dynamics with an acquisition time of 3.7 s per volume. Deformable registration of consecutive images generated 159 deformation vector fields (DVFs). We defined two motion metrics, the 50th percentile vector lengths (VL50) of the complete set of DVFs was used to measure median bowel motion. The 95th percentile vector lengths (VL95) was used to quantify high motion of the bowel. The precision of these metrics was assessed by calculating their variation (interquartile range) in three different time frames, defined as subsets of 40, 80, and 120 consecutive images, corresponding to acquisition times of 2.5, 5.0, and 7.5 min, respectively.Main results. For the full 10 min scan, the minimum motion per frame of 50% of the bowel volume (M50%) ranged from 0.6-3.5 mm for the VL50 motion metric and 2.3-9.0 mm for the VL95 motion metric, across all patients. At 7.5 min scan time, the variation in M50% was less than 0.5 mm in 100% (VL50) and 95% (VL95) of the subsets. A scan time of 5.0 and 2.5 min achieved a variation within 0.5 mm in 95.2%/81% and 85.7%/57.1% of the subsets, respectively.Significance. Our 3D cine-MRI technique quantifies bowel loop motion with 95%-100% confidence with a precision of 0.5 mm variation or less, using a 7.5 min scan time.


Assuntos
Imagem Cinética por Ressonância Magnética , Radioterapia Guiada por Imagem , Humanos , Estudos Retrospectivos , Imagem Cinética por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/métodos , Movimento (Física) , Radioterapia Guiada por Imagem/métodos
6.
J Magn Reson Imaging ; 59(5): 1832-1840, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-37681476

RESUMO

BACKGROUND: Cardiac MRI feature-tracking (FT) with breath-holding (BH) cine balanced steady state free precession (bSSFP) imaging is well established. It is unclear whether FT-strain measurements can be reliably derived from free-breathing (FB) compressed sensing (CS) bSSFP imaging. PURPOSE: To compare left ventricular (LV) strain analysis and image quality of an FB CS bSSFP cine sequence with that of a conventional BH bSSFP sequence in children. STUDY TYPE: Prospective. SUBJECTS: 40 children able to perform BHs (cohort 1 [12.1 ± 2.2 years]) and 17 children unable to perform BHs (cohort 2 [5.2 ± 1.8 years]). FIELD STRENGTH/SEQUENCE: 3T, bSSFP sequence with and without CS. ASSESSMENT: Acquisition times and image quality were assessed. LV myocardial deformation parameters were compared between BH cine and FB CS cine studies in cohort 1. Strain indices and image quality of FB CS cine studies were also assessed in cohort 2. Intraobserver and interobserver variability of strain parameters was determined. STATISTICAL TESTS: Paired t-test, Wilcoxon signed-rank test, intraclass correlation coefficient (ICC), and Bland-Altman analysis. A P-value <0.05 was considered statistically significant. RESULTS: In cohort 1, the mean acquisition time of the FB CS cine study was significantly lower than for conventional BH cine study (15.6 s vs. 209.4 s). No significant difference were found in global circumferential strain rate (P = 0.089), global longitudinal strain rate (P = 0.366) and EuroCMR image quality scores (P = 0.128) between BH and FB sequences in cohort 1. The overall image quality score of FB CS cine in cohort 2 was 3.5 ± 0.5 with acquisition time of 14.7 ± 2.1 s. Interobserver and intraobserver variabilities were good to excellent (ICC = 0.810 to 0.943). DATA CONCLUSION: FB CS cine imaging may be a promising alternative technique for strain assessment in pediatric patients with poor BH ability. LEVEL OF EVIDENCE: 1 TECHNICAL EFFICACY: Stage 1.


Assuntos
Coração , Função Ventricular Esquerda , Humanos , Criança , Estudos Prospectivos , Ventrículos do Coração/diagnóstico por imagem , Imageamento por Ressonância Magnética , Imagem Cinética por Ressonância Magnética/métodos , Reprodutibilidade dos Testes
7.
Eur Heart J Cardiovasc Imaging ; 25(4): 548-557, 2024 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-37987558

RESUMO

AIMS: To identify clinical correlates of myocardial T1ρ and to examine how myocardial T1ρ values change under various clinical scenarios. METHODS AND RESULTS: A total of 66 patients (26% female, median age 57 years [Q1-Q3, 44-65 years]) with known structural heart disease and 44 controls (50% female, median age 47 years [28-57 years]) underwent cardiac magnetic resonance imaging at 1.5 T, including T1ρ mapping, T2 mapping, native T1 mapping, late gadolinium enhancement, and extracellular volume (ECV) imaging. In controls, T1ρ positively related with T2 (P = 0.038) and increased from basal to apical levels (P < 0.001). As compared with controls and remote myocardium, T1ρ significantly increased in all patients' sub-groups and all types of myocardial injuries: acute and chronic injuries, focal and diffuse tissue abnormalities, as well as ischaemic and non-ischaemic aetiologies (P < 0.05). T1ρ was independently associated with T2 in patients with acute injuries (P = 0.004) and with native T1 and ECV in patients with chronic injuries (P < 0.05). Myocardial T1ρ mapping demonstrated good intra- and inter-observer reproducibility (intraclass correlation coefficient = 0.86 and 0.83, respectively). CONCLUSION: Myocardial T1ρ mapping appears to be reproducible and equally sensitive to acute and chronic myocardial injuries, whether of ischaemic or non-ischaemic origins. It may thus be a contrast-agent-free biomarker for gaining new and quantitative insight into myocardial structural disorders. These findings highlight the need for further studies through prospective and randomized trials.


Assuntos
Cardiomiopatias , Traumatismos Cardíacos , Humanos , Feminino , Pessoa de Meia-Idade , Masculino , Meios de Contraste , Reprodutibilidade dos Testes , Estudos Prospectivos , Imagem Cinética por Ressonância Magnética/métodos , Gadolínio , Miocárdio/patologia , Cardiomiopatias/patologia , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética/efeitos adversos , Valor Preditivo dos Testes
8.
Int J Cardiovasc Imaging ; 40(1): 157-165, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37831292

RESUMO

PURPOSE: Poor acoustic windows make interval assessment of systolic function in patients with (Duchenne Muscular Dystrophy) DMD by echocardiography (echo) difficult. Cardiac magnetic resonance imaging (CMR) can be challenging in DMD patients due to study duration and patient discomfort. We developed an abbreviated CMR (aCMR) protocol and hypothesized that aCMR would compare favorably to echo in image quality and clinical utility without significant differences in exam duration, patient satisfaction, and functional measurements. METHODS: DMD patients were recruited prospectively to undergo echo and aCMR. Modalities were compared with a global quality assessment score (GQAS), clinical utility score (CUS), and patient satisfaction score (PSS). Results were compared using Wilcoxon signed-rank tests, Spearman correlations, intraclass correlations, and Bland-Altman analyses. RESULTS: Nineteen DMD patients were included. PSS scores and exam duration were equivalent between modalities, while CUS and GQAS scores favored aCMR. ACMR scored markedly higher than echo in RV visualization and assessment of atrial size. Older age was negatively correlated with echo GQAS and CUS scores, as well as aCMR PSS scores. Higher BMI was positively correlated with aCMR GQAS scores. Nighttime PPV requirement and non-ambulatory status were correlated with worse echo CUS scores. Poor image quality precluding quantification existed in five (26%) echo and zero (0%) aCMR studies. There was moderate correlation between aCMR and echo for global circumferential strain and left ventricular four chamber global longitudinal strain. CONCLUSION: The aCMR protocol resulted in improved clinical relevance and quality scores relative to echo, without significant detriment to patient satisfaction or exam duration.


Assuntos
Distrofia Muscular de Duchenne , Disfunção Ventricular Esquerda , Humanos , Distrofia Muscular de Duchenne/complicações , Distrofia Muscular de Duchenne/diagnóstico por imagem , Ecocardiografia/métodos , Satisfação do Paciente , Valor Preditivo dos Testes , Imageamento por Ressonância Magnética , Átrios do Coração , Imagem Cinética por Ressonância Magnética/métodos
9.
J Thorac Imaging ; 39(2): 127-135, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-37982533

RESUMO

BACKGROUND: Cardiac magnetic resonance imaging protocols have been adapted to fit the needs for faster, more efficient acquisitions, resulting in the development of highly accelerated, compressed sensing-based (CS) sequences. The aim of this study was to evaluate intersoftware and interacquisition differences for postprocessing software applied to both CS and conventional cine sequences. MATERIALS AND METHODS: A total of 106 individuals (66 healthy volunteers, 40 patients with dilated cardiomyopathy, 51% female, 38±17 y) underwent cardiac magnetic resonance at 3T with retrospectively gated conventional cine and CS sequences. Postprocessing was performed using 2 commercially available software solutions and 1 research prototype from 3 different developers. The agreement of clinical and feature-tracking strain parameters between software solutions and acquisition types was assessed by Bland-Altmann analyses and intraclass correlation coefficients. Differences between softwares and acquisitions were assessed using Kruskal-Wallis analysis of variances. In addition, receiver operating characteristic curve-derived cutoffs were used to evaluate whether sequence-specific cutoffs influence disease classification. RESULTS: There were significant intersoftware ( P <0.002 for all except LV end-diastolic volume per body surface area) and interacquisition differences ( P <0.02 for all except end-diastolic volume per body surface area from Neosoft, left ventricular mass per body surface area from cvi42 and TrufiStrain and global circumferential strain from Neosoft). However, the intraclass correlation coefficients between acquisitions were strong-to-excellent for all parameters (all ≥0.81). In comparing individual softwares to a pooled mean, Bland-Altmann analyses revealed smaller magnitudes of bias for cine acquisition than for CS acquisition. In addition, the application of conventional cutoffs to CS measurements did not result in the false reclassification of patients. CONCLUSION: Significantly lower magnitudes of strain and volumetric parameters were observed in retrospectively gated CS acquisitions, despite strong-to-excellent agreement amongst software solutions and acquisition types. It remains important to be aware of the acquisition type in the context of follow-up examinations, where different cutoffs might lead to misclassifications.


Assuntos
Interpretação de Imagem Assistida por Computador , Imagem Cinética por Ressonância Magnética , Humanos , Feminino , Masculino , Estudos Retrospectivos , Imagem Cinética por Ressonância Magnética/métodos , Interpretação de Imagem Assistida por Computador/métodos , Reprodutibilidade dos Testes , Ventrículos do Coração , Função Ventricular Esquerda
10.
J Heart Lung Transplant ; 43(5): 745-754, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38141894

RESUMO

BACKGROUND: In pediatric heart transplant (PHT), cardiac catheterization with endomyocardial biopsy (EMB) is standard for diagnosing acute rejection (AR) and cardiac allograft vasculopathy (CAV) but is costly and invasive. OBJECTIVES: To evaluate the ability of cardiac magnetic resonance (CMR) to noninvasively identify differences in PHT patients with AR and CAV. METHODS: Patients were enrolled at three children's hospitals. Data were collected from surveillance EMB or EMB for-cause AR. Patients were excluded if they had concurrent diagnoses of AR and CAV, CMR obtained >7days from AR diagnosis, they had EMB negative AR, or could not undergo contrasted, unsedated CMR. Kruskal-Wallis test was used to compare groups: (1) No AR or CAV (Healthy), (2) AR, (3) CAV. Wilcoxon rank-sum test was used for pairwise comparisons. RESULTS: Fifty-nine patients met inclusion criteria (median age 17years [IQR 15-19]) 10 (17%) with AR, and 11 (19%) with CAV. AR subjects had worse left ventricular ejection fraction compared to Healthy patients (p = 0.001). Global circumferential strain (GCS) was worse in AR (p = 0.054) and CAV (p = 0.019), compared to Healthy patients. ECV, native T1, and T2 z-scores were elevated in patients with AR. CONCLUSIONS: CMR was able to identify differences between CAV and AR. CAV subjects had normal global function but abnormal GCS which may suggest subclinical dysfunction. AR patients have abnormal function and tissue characteristics consistent with edema (elevated ECV, native T1 and T2 z-scores). Characterization of CMR patterns is critical for the development of noninvasive biomarkers for PHT and may decrease dependence on EMB.


Assuntos
Rejeição de Enxerto , Transplante de Coração , Imagem Cinética por Ressonância Magnética , Humanos , Transplante de Coração/efeitos adversos , Masculino , Feminino , Adolescente , Imagem Cinética por Ressonância Magnética/métodos , Adulto Jovem , Aloenxertos , Doença Aguda , Estudos Retrospectivos , Criança , Miocárdio/patologia , Doença da Artéria Coronariana/etiologia , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/diagnóstico
11.
Echocardiography ; 40(12): 1350-1355, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37955614

RESUMO

OBJECTIVE: Right ventricular (RV) dilatation and dysfunction are usually present in heart transplant (HTx) patients and worsened with residual pulmonary hypertension (PH). We aimed to determine the ability of different echocardiographic modalities to evaluate RV function in comparison with cardiac magnetic resonance (CMR) and their relations with pulmonary hemodynamics in HTx patients. METHODS: A total of 62 data sets [echocardiographic, hemodynamic, and CMR] were acquired from 35 HTx patients. Comprehensive echocardiography, including two-dimensional (2D) transthoracic echocardiography, speckle tracking echocardiography, and three-dimensional (3D) echocardiography, was performed. Mean pulmonary artery pressure (mPAP) was obtained invasively from right heart catheterization. The correlations between all echocardiographic parameters and CMR imaging data and the differences between patients with and without residual PH were evaluated. RESULTS: Diastolic and systolic RV volumes and RV ejection fraction (RVEF) by 3D echocardiography correlated strongly with CMR-derived volumes and RVEF (r = .91, r = .79, r = .64; p < .0001 for each, respectively). Among other parameters, RV fractional area change (r = .439; p < .001) and RV free wall longitudinal strain (RVFW-LS) (r = -.34; p < .05) correlated moderately with CMR-RVEF, whereas tricuspid annulus S' velocity (r = .29; p < .05) and tricuspid annular systolic plane excursion (r = .27; p < .05) correlated weakly with CMR-RVEF. Additionally, 3D-RVEF and RVFW-LS were significantly decreased in studies with mPAP ≥ 20 mm Hg in comparison to those with mPAP < 20 mm Hg (47.7 ± 3.7 vs. 50.9 ± 5.3, p = .04 and -15.5 ± 3.1 vs. -17.5 ± 3, p = .03, respectively). CONCLUSION: The best method for the evaluation of RV function in HTx recipients is 3D echocardiography. Besides, the subclinical impact of residual PH on RV function can be best determined by RVFW-LS and 3D-RVEF in these patients.


Assuntos
Transplante de Coração , Hipertensão Pulmonar , Disfunção Ventricular Direita , Humanos , Função Ventricular Direita , Imagem Cinética por Ressonância Magnética/métodos , Ecocardiografia/métodos , Hipertensão Pulmonar/diagnóstico por imagem , Transplante de Coração/efeitos adversos , Hemodinâmica , Volume Sistólico , Disfunção Ventricular Direita/diagnóstico por imagem , Disfunção Ventricular Direita/etiologia
12.
Phys Med Biol ; 68(24)2023 Dec 13.
Artigo em Inglês | MEDLINE | ID: mdl-37918023

RESUMO

Objective. It was a great challenge to train an excellent and generalized model on an ultra-small data set composed of multi-orientation cardiac cine magnetic resonance imaging (MRI) images. We try to develop a 3D deep learning method based on an ultra-small training data set from muti-orientation cine MRI images and assess its performance of automated biventricular structure segmentation and function assessment in multivendor.Approach. We completed the training and testing of our deep learning networks using only heart datasets of 150 cases (90 cases for training and 60 cases for testing). This datasets were obtained from three different MRI vendors and each subject included two phases of the cardiac cycle and three cine sequences. A 3D deep learning algorithm combining Transformers and U-Net was trained. The performance of the segmentation was evaluated using the Dice metric and Hausdorff distance (HD). Based on this, the manual and automatic results of cardiac function parameters were compared with Pearson correlation, intraclass correlation coefficient (ICC) and Bland-Altman analysis in multivendor.Main results. The results show that the average Dice of 0.92, 0.92, 0.94 and HD95 of 2.50, 1.36, 1.37 for three sequences. The automatic and manual results of seven parameters were excellently correlated with the lowestr2 value of 0.824 and the highest of 0.983. The ICC (0.908-0.989,P< 0.001) showed that the results were highly consistent. Bland-Altman with a 95% limit of agreement showed there was no significant difference except for the difference in RVESV (P= 0.005) and LVM (P< 0.001).Significance. The model had high accuracy in segmentation and excellent correlation and consistency in function assessment. It provides a fast and effective method for studying cardiac MRI and heart disease.


Assuntos
Imagem Cinética por Ressonância Magnética , Redes Neurais de Computação , Imagem Cinética por Ressonância Magnética/métodos , Coração/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Algoritmos
13.
Eur J Radiol ; 163: 110831, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37059004

RESUMO

PURPOSE: To compare standard breath-hold (BH) cine imaging to a radial pseudo-golden-angle free-breathing (FB) technique in congenital heart disease (CHD). METHODS: In this prospective study, short-axis and 4-chamber BH and FB cardiac MRI sequences of 25 participants with CHD acquired at 1.5 Tesla, were quantitatively compared regarding ventricular volumes, function, interventricular septum thickness (IVSD), apparent signal to noise ratio (aSNR), and estimated contrast to noise ratio (eCNR). For qualitative comparison, three image quality criteria (contrast, endocardial edge definition, and artefacts) were rated on a 5-point Likert scale (5: excellent, 1: non-diagnostic). Paired t-Test was used for group comparisons, Bland-Altman analysis for agreement between techniques. Inter-reader agreement was compared using intraclass correlation coefficient. RESULTS: IVSD (BH 7.4 ± 2.1 mm vs FB 7.4 ± 1.9 mm, p =.71), biventricular ejection fraction (left ventricle [LV]: 56.4 ± 10.8% vs 56.1 ± 9.3%, p =.83; right ventricle [RV]: 49.5 ± 8.6% vs 49.7 ± 10.1%, p =.83), and biventricular end diastolic volume (LV: 176.3 ± 63.9 ml vs 173.9 ± 64.9 ml, p =.90; RV: 185.4 ± 63.8 ml vs 189.6 ± 66.6 ml, p =.34) were comparable. Mean measurement time for FB short-axis sequences was 8.1 ± 1.3 compared to 4.4 ± 1.3 min for BH (p <.001). Subjective image quality between sequences was deemed comparable, (4.6 ± 0.6 vs 4.5 ± 0.6, p =.26, for 4-chamber views) with a significant difference regarding short-axis views (4.9 ± 0.3 vs 4.5 ± 0.6, p =.008). aSNR was similar (BH 25.8 ± 11.2 vs FB 22.2 ± 9.5, p =.24), while eCNR was higher for BH (89.1 ± 36.1 vs 68.5 ± 32.1, p =.03). CONCLUSION: FB sequences yielded comparable results to BH regarding image quality, biventricular volumetry, and function, though measurement times were longer. The FB sequence described might be clinically valuable when BHs are insufficiently performed.


Assuntos
Cardiopatias Congênitas , Respiração , Humanos , Estudos Prospectivos , Imageamento por Ressonância Magnética/métodos , Cardiopatias Congênitas/diagnóstico por imagem , Imagem Cinética por Ressonância Magnética/métodos , Suspensão da Respiração , Reprodutibilidade dos Testes
14.
J Nucl Cardiol ; 30(5): 1947-1958, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-36918456

RESUMO

BACKGROUND: To compare phase analysis with positron emission tomography (PA) and magnetic resonance feature tracking derived myocardial strain (FT) for left ventricular (LV) mechanical dyssynchrony using PETMR system in patients with ischemic heart disease. METHODS AND RESULTS: Patients who underwent rest-pharmacological stress 13N ammonia PETMR were enrolled. Histogram bandwidth (BW) and phase standard deviation (PSD) were compared to global longitudinal, long axis radial, short axis circumferential, and radial strain (GLS, GRS, SA Circ, and SA Rad) obtained from FT. LV dyssynchrony index (SDI) derived from PA and FT were compared. BW and PSD showed significant correlations with FT (a Pearson's coefficient r = 0.64, P < .0001, and r = 0.51, P < .0001 for SA Circ; r = 0.67, P < .0001, and r = 0.74, P < .0001 for GLS; r = - 0.60, P < .0001, r = - 0.61, P < .0001 for SA Rad; r = - 0.62, P < .0001, and r = - 0.68, P < .0001 for GRS, respectively). Bland-Altman plots for SDI showed a preferable agreement (95% limit of agreement - 0.12 to 0.075, - 0.20 to 0.098, - 0.38 to 0.077, and - 0.37 to 0.032; bias 0.0068 ± 0.056, 0.026 ± 0.068, 0.11 ± 0.088, and 0.13 ± 0.079 for SA Circ, SA Rad, GLS, and GRS, respectively). CONCLUSION: In simultaneous acquisition using PETMR, comparison of PET phase analysis and MR strain showed a good correlation.


Assuntos
Amônia , Disfunção Ventricular Esquerda , Humanos , Disfunção Ventricular Esquerda/diagnóstico por imagem , Imagem Cinética por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/métodos , Tomografia por Emissão de Pósitrons , Função Ventricular Esquerda , Reprodutibilidade dos Testes , Valor Preditivo dos Testes
15.
Int J Cardiovasc Imaging ; 39(6): 1203-1205, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36826615

RESUMO

Reliability (repeatability or agreement) is assessed by different statistical tests including Pearson r or Spearman rho which is one of the common mistakes in reliability analysis. Pearson r or Spearman rho correlation coefficient only assesses the linearity between two continuous variables. Any shift in the regression line's location or scale, which leads to non-reliability, cannot be detected by these correlation coefficients. In reliability analysis, the individual approach should be considered instead of the global average. To correctly assess the reliability (agreement), for continuous variables, either the Bland -Altman plot or Intra-class correlation coefficient (ICC) absolute measure should be applied.


Assuntos
Aprendizado Profundo , Humanos , Adulto , Imagem Cinética por Ressonância Magnética/métodos , Reprodutibilidade dos Testes , Valor Preditivo dos Testes , Função Ventricular
16.
Int J Cardiovasc Imaging ; 39(5): 1001-1011, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36648573

RESUMO

This study aimed to assess the image quality and accuracy of respiratory-gated real-time two-dimensional (2D) cine incorporating deep learning reconstruction (DLR) for the quantification of biventricular volumes and function compared with those of the standard reference, that is, breath-hold 2D balanced steady-state free precession (bSSFP) cine, in an adult population. Twenty-four patients (15 men, mean age 50.7 ± 16.5 years) underwent cardiac magnetic resonance for clinical indications, and 2D DLR and bSSFP cine were acquired on the short-axis view. The image quality scores were based on three main criteria: blood-to-myocardial contrast, endocardial edge delineation, and presence of motion artifacts throughout the cardiac cycle. Biventricular end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), ejection fraction (EF), and left ventricular mass (LVM) were analyzed. The 2D DLR cine had significantly shorter scan time than bSSFP (41.0 ± 11.3 s vs. 327.6 ± 65.8 s; p < 0.0001). Despite an analysis of endocardial edge definition and motion artifacts showed significant impairment using DLR cine compared with bSSFP (p < 0.01), the two sequences demonstrated no significant difference in terms of biventricular EDV, ESV, SV, and EF (p > 0.05). Moreover, the linear regression yielded good agreement between the two techniques (r ≥ 0.76). However, the LVM was underestimated for DLR cine (109.8 ± 34.6 g) compared with that for bSSFP (116.2 ± 40.2 g; p = 0.0291). Respiratory-gated 2D DLR cine is a reliable technique that could be used in the evaluation of biventricular volumes and function in an adult population.


Assuntos
Aprendizado Profundo , Masculino , Adulto , Humanos , Pessoa de Meia-Idade , Idoso , Reprodutibilidade dos Testes , Valor Preditivo dos Testes , Imagem Cinética por Ressonância Magnética/métodos , Volume Sistólico , Função Ventricular
17.
Heart Vessels ; 38(5): 662-670, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36436026

RESUMO

The study was designed to assess the accuracy of contrast-enhanced balanced steady-state free precession (cine-SSFP) CMR imaging sequences to exhibit myocardial hyperemia in acute myocarditis, which has for a long time been investigated in some centers using early gadolinium enhancement (EGE) sequence. Contrast-enhanced cine-SSFP (CESSFP) sequences were compared to precontrast cine-SSFP sequences to calculate the early cine-contrast enhancement in 36 consecutive patients with acute myocarditis and 36 controls matched for age and gender. Four-chamber views images were obtained in each subject before and after gadolinium injection. Absolute and relative left ventricular myocardial enhancement of the overall myocardium, then separately of the lateral wall and interventricular septum was analyzed in telediastole. Myocarditis patients displayed higher cine-SSFP absolute enhancement than controls (overall left ventricular myocardium 2.38 ± 0.33 vs 1.84 ± 0.31; lateral wall 2.45 ± 0.35 vs 1.83 ± 0.32; and septum 2.26 ± 0.29 vs 1.82 ± 0.29, p < 0.0001 for all). Less significant differences were observed for the relative enhancement (p < 0.05 for all). Using ROC curves, the optimal threshold value of absolute enhancement to diagnose acute myocarditis was 2.05 (sensitivity: 86%; specificity: 81%). Given the simplicity of use, contrast-enhanced cine-SSFP sequences should be used as an additional diagnostic tool to detect hyperemia in acute myocarditis patients.


Assuntos
Hiperemia , Miocardite , Humanos , Miocardite/diagnóstico por imagem , Meios de Contraste , Imagem Cinética por Ressonância Magnética/métodos , Estudos de Viabilidade , Hiperemia/diagnóstico , Gadolínio , Doença Aguda , Miocárdio , Valor Preditivo dos Testes
18.
Int J Cardiovasc Imaging ; 39(2): 411-421, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36331683

RESUMO

High-resolution scar characterization using late gadolinium enhancement cardiac magnetic resonance imaging (LGE-CMR) is useful for guiding ventricular arrhythmia (VA) treatment. However, imaging study quality may be degraded by breath-holding difficulties, arrhythmias, and implantable cardioverter-defibrillators (ICDs). We evaluated the effect of image quality on left ventricle (LV) base to apex scar interpretation in pre-VA ablation LGE-CMR. 43 consecutive patients referred for VA ablation underwent gradient-recalled-echo LGE-CMR. In ICD patients (n = 24), wide-bandwidth inversion-recovery suppressed ICD artifacts. In non-ICD patients, single-shot steady-state free-precession LGE-CMR could also be performed to reduce respiratory motion/arrhythmia artifacts. Study quality was assessed for adequate/limited scar interpretation due to cardiac/respiratory motion artifacts, ICD-related artifacts, and image contrast. 28% of non-ICD patients had studies where image quality limited scar interpretation in at least one image compared to 71% of ICD patient studies (p = 0.012). A median of five image slices had limited quality per ICD patient study, compared to 0 images per non-ICD patient study. Poorer quality in ICD patients was largely due to motion-related artifacts (54% ICD vs 6% non-ICD studies, p = 0.001) as well as ICD-related image artifacts (25% of studies). In VA ablation patients with ICDs, conventional CMR protocols frequently have image slices with limited scar interpretation, which can limit whole-heart scar assessment. Motion artifacts contribute to suboptimal image quality, particularly in ICD patients. Improved methods for motion and ICD artifact suppression may better delineate high-resolution LGE scar features of interest for guiding VA ablation.


Assuntos
Desfibriladores Implantáveis , Taquicardia Ventricular , Humanos , Meios de Contraste , Cicatriz/patologia , Gadolínio , Valor Preditivo dos Testes , Imageamento por Ressonância Magnética/métodos , Arritmias Cardíacas , Espectroscopia de Ressonância Magnética , Imagem Cinética por Ressonância Magnética/métodos
19.
Jpn J Radiol ; 41(2): 142-152, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36227459

RESUMO

PURPOSE: We applied a combination of compressed-sensing (CS) and retrospective motion correction to free-breathing cine magnetic resonance (MR) (FBCS cine MoCo). We validated FBCS cine MoCo by comparing it with breath-hold (BH) conventional cine MR. MATERIALS AND METHODS: Thirty-five volunteers underwent both FBCS cine MoCo and BH conventional cine MR imaging. Twelve consecutive short-axis cine images were obtained. We compared the examination time, image quality and biventricular volumetric assessments between the two cine MR. RESULTS: FBCS cine MoCo required a significantly shorter examination time than BH conventional cine (135 s [110-143 s] vs. 198 s [186-349 s], p < 0.001). The image quality scores were not significantly different between the two techniques (End-diastole: FBCS cine MoCo; 4.7 ± 0.5 vs. BH conventional cine; 4.6 ± 0.6; p = 0.77, End-systole: FBCS cine MoCo; 4.5 ± 0.5 vs. BH conventional cine; 4.5 ± 0.6; p = 0.52). No significant differences were observed in all biventricular volumetric assessments between the two techniques. The mean differences with 95% confidence interval (CI), based on Bland-Altman analysis, were - 0.3 mL (- 8.2 - 7.5 mL) for LVEDV, 0.2 mL (- 5.6 - 5.9 mL) for LVESV, - 0.5 mL (- 6.3 - 5.2 mL) for LVSV, - 0.3% (- 3.5 - 3.0%) for LVEF, - 0.1 g (- 8.5 - 8.3 g) for LVED mass, 1.4 mL (- 15.5 - 18.3 mL) for RVEDV, 2.1 mL (- 11.2 - 15.3 mL) for RVESV, - 0.6 mL (- 9.7 - 8.4 mL) for RVSV, - 1.0% (- 6.5 - 4.6%) for RVEF. CONCLUSION: FBCS cine MoCo can potentially replace multiple BH conventional cine MR and improve the clinical utility of cine MR.


Assuntos
Coração , Imagem Cinética por Ressonância Magnética , Humanos , Imagem Cinética por Ressonância Magnética/métodos , Estudos Retrospectivos , Coração/diagnóstico por imagem , Respiração , Imageamento por Ressonância Magnética/métodos , Suspensão da Respiração , Reprodutibilidade dos Testes
20.
Int J Cardiol ; 373: 134-141, 2023 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-36395920

RESUMO

PURPOSE: As a novel metric, entropy generated from late gadolinium enhancement (LGE) cardiac magnetic resonance (CMR) can be utilized to assess tissue heterogeneity. However, it is unknown if it can be utilized for risk stratification in hypertrophic cardiomyopathy (HCM). In addition, it is unknown if LGE entropy correlates with LGE mass%, which is commonly utilized for fibrosis assessment. This research was done to investigate these issues. MATERIALS AND METHODS: Patients with HCM who underwent 3.0-T CMR between January 2015 and January 2020 were prospectively enrolled and classified into low- and high-risk groups according to the AHA/ACC risk stratification guideline for 2020. The LGE entropy was automatically estimated using a generic Python package algorithm. On CMR imaging, the LGE mass% was determined using the CVI 42 software. Endpoint events included sudden cardiac death (SCD), hospital readmission owing to heart failure, and implantable cardioverter defibrillator (ICD) treatment for ventricular arrhythmias. RESULTS: A total of 109 HCM participants (70 males) were included. During the follow-up (23 ± 7 months), the patients in the high-risk group had higher LGE entropy (p < 0.001) and LGE mass% (p < 0.001) than those in the low-risk group, and patients with endpoint events had higher LGE entropy (p < 0.001) and LGE mass% (p < 0.001) than those without endpoint events. In all participants, there was a link between LGE entropy and LGE mass%, according to the Spearman rank correlation analysis (p < 0.001; r = 0.667). In ROC analysis, the area under the curve (AUC) of LGE entropy was 0.893 (95% CI, 0.794-0.993; P<0.001), AUC of LGE mass% was 0.826 (95% CI, 0.737-0.914; P<0.001), AUC of LVEF was 0.610 (95% CI, 0.473-0.748; P = 0.117) and AUC of 2020 AHA/ACC guideline for risk stratification was 0.716 (95% CI, 0.617-0.815; P = 0.002). According to Kaplan-Meier curves, HCM with a higher LGE entropy (≥cutoff value (<5.873) or ≥ thied tertile (5.540)) were more likely to experience the endpoint events. Following adjustment for the 2020 AHA/ACC guideline for risk categorization, LGE mass%, or decreased LVEF, Cox analysis showed that LGE entropy was independently linked with endpoint events. CONCLUSIONS: The variability and extent of LGE pictures can be reflected by LGE entropy, which is a reliable, usable, and repeatable metric for risk classification in HCM. It is a prognostic indicator of endpoint events that is independent of other risk indicators.


Assuntos
Cardiomiopatia Hipertrófica , Meios de Contraste , Masculino , Humanos , Gadolínio , Prognóstico , Entropia , Fatores de Risco , Morte Súbita Cardíaca , Valor Preditivo dos Testes , Imagem Cinética por Ressonância Magnética/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA