Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 742
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
Eur J Pediatr ; 183(7): 2855-2863, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38592486

RESUMO

Iodine is a micronutrient required for the production of thyroid hormones, which regulate metabolism, growth, and neurodevelopment. Iodine deficiency among adolescents and young adults is a major global health issue. We analyzed data from the Global Burden of Disease 2019 database to calculate the prevalence, incidence, and disability-adjusted life-year (DALY) rates of iodine deficiency among adolescents and young adults. We explored the specific year with the most substantial changes in the trends of iodine deficiency among adolescents with annual percentage change (APC) by Joinpoint Regression analysis. Descriptive analyses were conducted to characterize the iodine deficiency burden according to age, sex, location, and sociodemographic index (SDI) quintiles. All measures are listed with 95% uncertainty intervals (UIs), and all rates are reported per 100,000 individuals. From 1990 to 2019, the iodine deficiency prevalence rate among adolescents decreased from 3082.43 (95% uncertainty interval [UI], 2473.01-3855.86) to 2190.84 (95% [UI], 1729.18-2776.16) per 100,000 population, with an AAPC of -1.15 (95% confidence interval [CI], -1.29 to -1.02). Regarding the SDI in 2019, the highest prevalence and DALY rates of iodine deficiency were reported in low-SDI countries. In 1990, Southeast Asia had the highest prevalence and DALYs rates for iodine deficiency among adolescents, while in 2019, Africa had the highest prevalence rate (3330.12). CONCLUSION: Globally, the iodine deficiency burden among adolescents has substantially decreased since 1990; however, low-SDI countries still bear a great burden. Implementation measures and monitoring systems should be strengthened to reduce the iodine deficiency burden, especially among adolescents. WHAT IS KNOWN: • Iodine deficiency can cause severe or irreversible developmental disorders, particularly in adolescents and young adults. • Universal Salt Iodization was implemented for ensuring appropriate iodine intake. WHAT IS NEW: • We found substantial declines in the prevalence rates of iodine deficiency among adolescents during the past three decades. Globally, the disability-adjusted life-year rate of iodine deficiency among adolescents decreased from 56.17 in 1990 to 35.38 in 2019. • Iodine deficiency among adolescents in low- sociodemographic index countries still bear a great burden.


Assuntos
Carga Global da Doença , Saúde Global , Iodo , Humanos , Adolescente , Iodo/deficiência , Feminino , Masculino , Adulto Jovem , Saúde Global/estatística & dados numéricos , Prevalência , Carga Global da Doença/tendências , Anos de Vida Ajustados por Deficiência , Incidência , Anos de Vida Ajustados por Qualidade de Vida
2.
J Chin Med Assoc ; 87(6): 590-596, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38651854

RESUMO

BACKGROUND: Iodine nutrition is critical for fetal neurodevelopment in the first trimester of pregnancy, a period associated with dramatic changes in thyroid function. The aim of this study was to evaluate iodine nutritional status and thyroid function reference ranges in the first trimester in Taiwan. METHODS: Pregnant women aged 20 years and above in the first trimester were recruited in Taipei Veterans General Hospital, Taiwan from March 2019 to July 2022. Each participant provided a spot urine sample for measurement of urinary iodine concentration (UIC) and a blood sample for checkup of thyroid function and thyroid autoantibodies. A simple food frequency questionnaire was also completed. RESULTS: A total of 209 women with a mean age of 32.9 ± 4.4 years were enrolled. The median UIC was 160.9 µg/L (interquartile range [IQR]: 105.0-246.2 µg/L), indicating overall iodine sufficiency. The gestational thyroid function reference ranges were: thyroid stimulating hormone (TSH) (median: 0.93 [0.007-2.9] µIU/mL), free T4 (1.3 [0.93-2.2] ng/dL), free T3 (3.0 [2.3-5.0] ng/dL), total T4 (9.9 [6.4-16.9] ng/dL), and total T3 (135 [88-231] ng/dL). If the nonpregnant reference range of serum TSH was used, eight women (4.8%) would be misclassified as having subclinical hyperthyroidism, and two women (1.2%) with subclinical hypothyroidism would be missed. In multivariate analysis, nulliparous (adjusted odds ratio [OR] from model 1-3: 2.02, 2.05, 2.02; 95% CI, 1.08-3.77, 1.10-3.81, 1.11-3.66; p = 0.027, 0.023, 0.022, respectively) and multivitamin nonusers (adjusted OR from model 1-3: 1.86, 1.85, 1.78; 95% CI, 1.04-3.34, 1.03-3.32, 1.004-3.71; p = 0.038, 0.039, 0.049, respectively) had increased odds of having lower UIC levels <150 µg/L. CONCLUSION: The iodine nutritional status in the first trimester is adequate in Taiwan; however, certain subgroups such as nulliparous and multivitamin nonusers are still at risk for iodine deficiency. Gestational thyroid function reference ranges are needed for correct diagnosis of thyroid dysfunction in pregnancy.


Assuntos
Iodo , Estado Nutricional , Primeiro Trimestre da Gravidez , Humanos , Feminino , Gravidez , Iodo/urina , Adulto , Valores de Referência , Taiwan , Glândula Tireoide/fisiologia , Testes de Função Tireóidea , Tireotropina/sangue , Adulto Jovem
3.
Artigo em Inglês | MEDLINE | ID: mdl-38331249

RESUMO

INTRODUCTION AND OBJECTIVES: Radioactive iodine therapy (RAIT) is recommended to reduce the risk of recurrence and metastasis in patients with intermediate-high risk differentiated thyroid cancer (DTC). In preparation for RAIT, stimulation of thyroid-stimulating hormone and reduction of body iodine pool are important for treatment success. For this purpose, patients are asked to reduce their iodine intake before RAIT, and the body iodine pool can be evaluated by measuring iodine excretion in urine before treatment. The aim of our study is to compare the methods used to measure the body iodine pool in the evaluation of the restricted iodine diet (RID) effectiveness applied in the RAIT preparation. PATIENTS AND METHODS: Eighty DTC patients discontinued levothyroxine three weeks before RAIT and followed up with a RID two weeks before treatment. After two weeks of RID, all patients collected their 24-h urine the day before the RAIT date. Patients completed 24-h urine samples on the morning of the RAIT date and also provided a spot urine sample. The estimated 24-h creatinine excretion of the patients was calculated. Estimated 24-h urinary iodine excretion (UIE) was calculated using the spot urine iodine/creatinine (I/C) ratio of the patients. 24-h UIE, iodine concentration in spot urine, I/C ratios in spot urine and estimated 24-h UIE of the patients were analyzed by comparing with each other. RESULTS: In 99% of the patients, RID efficiency was sufficient according to 24-h UIE before RAIT. The mean 24-h UIE was 48.81 micrograms/day (mcg/day) in 24-h urine samples taken from the patients to evaluate the body iodine pool. The patients' iodine concentrations in spot urine, I/C ratios in spot urine, and estimated 24-h UIE were all statistically significantly lower than actual 24-h UIE, which was the reference method (p: 0.026 vs <0.001 vs 0.041). Moderate positive correlation between 24-h UIE and iodine concentration in spot urine (r: 0.440), I/C ratio in spot urine (r: 0.493), and estimated 24-h UIE (r: 0.560) found. The strongest correlation was obtained with the estimated 24-h UIE. CONCLUSION: The estimated 24-h UIE obtained by using the I/C ratio in spot urine can be used practically and safely as an alternative to UIE in 24-h urine, which is the gold standard method for evaluating body iodine pool.


Assuntos
Adenocarcinoma , Iodo , Neoplasias da Glândula Tireoide , Humanos , Iodo/urina , Radioisótopos do Iodo/uso terapêutico , Creatinina/urina , Neoplasias da Glândula Tireoide/radioterapia , Estado Nutricional
4.
Neoplasia ; 50: 100977, 2024 04.
Artigo em Inglês | MEDLINE | ID: mdl-38354688

RESUMO

BACKGROUND: The inconformity (IC) between pathological and imaging remissions after neoadjuvant immunotherapy in patients with NSCLC can affect the evaluation of curative effect of neoadjuvant therapy and the decision regarding the chance of surgery. MATERIALS AND METHODS: Patients who achieved disease control(CR/PR/SD) after neoadjuvant chemoimmunotherapy from a clinical trial (NCT04326153) and after neoadjuvant chemotherapy during the same period were enrolled in this study. All patients underwent radical resection and systematic mediastinal lymphadenectomy after neoadjuvant treatments. The pathological remission, immunohistochemistry (CD4, CD8, CD20, CD56, FoxP3, CD68, CD163, CD11b tumor-infiltrating lymphocytes, or macrophages), and single-source dual-energy computed tomography (ssDECT) scans were assessed. The IC between imaging remission by CT and pathological remission was investigated. The underlying cause of IC, the correlation between IC and DFS, and prognostic biomarkers were explored. RESULTS: After neoadjuvant immunotherapy, enhanced immune killing and reduced immunosuppressive performance were observed. 70 % of neoadjuvant chemoimmunotherapy patients were in high/medium IC level. Massive necrosis and repair around and inside the cancer nest were the main pathological changes observed 30-45 days post-treatment with PD1/PD-L1 antibody and were the main causes of IC between the pathology and imaging responses after neoadjuvant immunotherapy. High IC and preoperative CD8 expression (H score ≥ 3) indicate a high pathological response rate and prolonged DFS. Iodine material density ssDECT images showed that the iodine content in the lesion causes hyperattenuation in post-neoadjuvant lesion in PCR patient. CONCLUSIONS: Compared to chemotherapy and targeted therapy, the efficacy of neoadjuvant immunotherapy was underestimated based on the RECIST criteria due to the unique antitumor therapeutic mechanism. Preoperative CD8+ expression and ssDECT predict this IC and evaluate the residual tumor cells. This is of great significance for screening immune beneficiaries and making more accurate judgments about the timing of surgery.


Assuntos
Carcinoma Pulmonar de Células não Pequenas , Iodo , Neoplasias Pulmonares , Humanos , Terapia Neoadjuvante , Microambiente Tumoral , Carcinoma Pulmonar de Células não Pequenas/patologia , Tomografia Computadorizada por Raios X , Imunoterapia , Neoplasias Pulmonares/patologia , Iodo/farmacologia , Iodo/uso terapêutico
5.
Med Phys ; 51(4): 2924-2932, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38358113

RESUMO

BACKGROUND: Photon-counting CT (PCCT) is the next-generation CT scanner that enables improved spatial resolution and spectral imaging. For full spectral processing, higher tube voltages compared to conventional CT are necessary to achieve the required spectral separation. This generated interest in the potential influence of thin slice high tube voltage PCCT on overall image quality and consequently on radiation dose. PURPOSE: This study first evaluated tube voltages and radiation doses applied in patients who underwent coronary CT angiography with PCCT and energy-integrating detector CT (EID-CT). Next, image quality of PCCT and EID-CT was objectively evaluated in a phantom study simulating different patient sizes at these tube voltages and radiation doses. METHODS: We conducted a retrospective analysis of clinical doses of patients scanned on a conventional and PCCT system. Average patient water equivalent diameters for different tube voltages were extracted from the dose reports for both EID-CT and PCCT. A conical phantom made of polyethylene with multiple diameters (26/31/36 cm) representing different patient sizes and containing an iodine insert was scanned with a EID-CT scanner using tube voltages and phantom diameters that match the patient scans and characteristics. Next, phantom scans were made with PCCT at a fixed tube voltage of 120 kV and with CTDIVOL values and phantom diameters identical to the EID-CT scans. Clinical image reconstructions at 0.6 mm slice thickness for conventional CT were compared to PCCT images with 0.4 mm slice thickness. Image quality was quantified using the detectability index (d'), which estimated the visibility of a 3 mm diameter contrast-enhanced coronary artery by considering noise, contrast, resolution, and human visual perception. Alongside d', noise, contrast and resolution were also individually assessed. In addition, the influence of various kernels (Bv40/Bv44/Bv48/Bv56), quantum iterative reconstruction strengths (QIR, 3/4) and monoenergetic levels (40/45/50/55 keV) for PCCT on d' was investigated. RESULTS: In this study, 143 patients were included: 47 were scanned on PCCT (120 kV) and the remaining on EID-CT (74 small-sized at 70 kV, 18 medium-sized at 80 kV and four large-sized at 90 kV). EID-CT showed 7%-17% higher d' than PCCT with Bv40 kernel and strength four for small/medium patients. Lower monoenergetic images (40 keV) helped mitigate the difference to 1%-6%. For large patients, PCCT's detectability was up to 31% higher than EID-CT. PCCT has thinner slices but similar noise levels for similar reconstruction parameters. The noise increased with lower keV levels in PCCT (≈30% increase), but higher QIR strengths reduced noise. PCCT's iodine contrast was stable across patient sizes, while EID-CT had 33% less contrast in large patients than in small-sized patients. CONCLUSION: At 120 kV, thin slice PCCT enables CCTA in phantom scans representing large patients without raising radiation dose or affecting vessel detectability. However, higher doses are needed for small and medium-sized patients to obtain a similar image quality as in EID-CT. The alternative of using lower mono-energetic levels requires further evaluation in clinical practice.


Assuntos
Iodo , Tomografia Computadorizada por Raios X , Humanos , Angiografia Coronária , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Imagens de Fantasmas , Doses de Radiação , Fótons
6.
BMC Public Health ; 24(1): 486, 2024 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-38360585

RESUMO

BACKGROUND: Nutritional deficiencies remain serious medical and public health issues worldwide, especially in children. This study aims to analyze cross-country inequality in four common nutritional deficiencies (protein-energy malnutrition, dietary iron deficiency, vitamin A deficiency and iodine deficiency) among children from 1990 to 2019 based on Global Burden of Disease (GBD) 2019 data. METHODS: Prevalence and disability-adjusted life years (DALYs) data as measures of four nutritional deficiency burdens in people aged 0 to 14 years were extracted from the GBD Results Tool. We analyzed temporal trends in prevalence by calculating the average annual percent change (AAPC) and quantified cross-country inequalities in disease burden using the slope index. RESULTS: Globally, the age-standardized prevalence rates of dietary iron deficiency, vitamin A deficiency and iodine deficiency decreased, with AAPCs of -0.14 (-0.15 to -0.12), -2.77 (-2.96 to -2.58), and -2.17 (-2.3 to -2.03) from 1999 to 2019, respectively. Significant reductions in socio-demographic index (SDI)-related inequality occurred in protein-energy malnutrition and vitamin A deficiency, while the health inequality for dietary iron deficiency and iodine deficiency remained basically unchanged. The age-standardized prevalence and DALY rates of the four nutritional deficiencies decreased as the SDI and healthcare access and quality index increased. CONCLUSIONS: The global burden of nutritional deficiency has decreased since 1990, but cross-country health inequalities still exist. More efficient public health measures are needed to reduce disease burdens, particularly in low-SDI countries/territories.


Assuntos
Iodo , Deficiências de Ferro , Desnutrição , Desnutrição Proteico-Calórica , Deficiência de Vitamina A , Criança , Humanos , Carga Global da Doença , Anos de Vida Ajustados por Qualidade de Vida , Disparidades nos Níveis de Saúde , Ferro da Dieta , Desigualdades de Saúde , Saúde Global
7.
Nutrients ; 16(3)2024 Feb 03.
Artigo em Inglês | MEDLINE | ID: mdl-38337734

RESUMO

The biosynthesis of thyroid hormones is essential for brain and neurological development. It requires iodine as a key component but is also influenced by other nutrients. Evidence for the combined nutrient status in relation to thyroid hormones during pregnancy is limited. We aimed to investigate the joint associations of iodine, selenium, zinc, calcium, magnesium and iron with maternal thyroid functions in 489 pregnant women from Hangzhou, China. Serum levels of six essential minerals and thyroid function parameters were measured during the first antenatal visit. Linear regression, quantile g-computation and Bayesian kernel machine regression were used to explore the individual and joint relationships between the six minerals and thyroid hormones. Linear regression analyses revealed that calcium was positively associated with free triiodothyronine (FT3). Zinc was positively associated with free thyroxine (FT4). Iodine was negatively associated with thyroid-stimulating hormone (TSH) and positively associated with FT3 and FT4. The quantile g-computation and BKMR models indicated that the joint nutrient concentration was negatively associated with TSH and positively associated with FT3 and FT4. Among the six minerals, iodine contributed most to thyroid function. The findings suggested that maintaining the appropriate concentration of minerals, either as individuals or a mixture, is important for thyroid health during pregnancy.


Assuntos
Iodo , Selênio , Feminino , Humanos , Gravidez , Gestantes , Cálcio , Teorema de Bayes , Testes de Função Tireóidea , Hormônios Tireóideos , Tireotropina , Zinco , China , Tiroxina
8.
Med Phys ; 51(4): 2941-2954, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38421665

RESUMO

BACKGROUND: In spite of the tremendous potential of game-changing biological image- and/or biologically guided radiation therapy (RT) and adaptive radiation therapy for cancer treatment, existing limited strategies for integrating molecular imaging and/or biological information with RT have impeded the translation of preclinical research findings to clinical applications. Additionally, there is an urgent need for a highly integrated small-animal radiation therapy (SART) platform that can seamlessly combine therapeutic and diagnostic capabilities to comprehensively enhance RT for cancer treatment. PURPOSE: We investigated a highly integrated quad-modal on-board imaging configuration combining positron emission tomography (PET), single-photon emission computed tomography (SPECT), photon-counting spectral CT, and cone-beam computed tomography (CBCT) in a SART platform using a Monte Carlo model as a proof-of-concept. METHODS: The quad-modal on-board imaging configuration of the SART platform was designed and evaluated by using the GATE Monte Carlo code. A partial-ring on-board PET imaging subsystem, utilizing advanced semiconductor thallium bromide detector technology, was designed to achieve high sensitivity and spatial resolution. On-board SPECT, photon-counting spectral-CT, and CBCT imaging were performed using a single cadmium zinc telluride flat detector panel. The absolute peak sensitivity and scatter fraction of the PET subsystem were estimated by using simulated phantoms described in the NEMA NU-4 standard. The spatial resolution of the PET image of the platform was evaluated by imaging a simulated micro-Derenzo hot-rod phantom. To evaluate the quantitative imaging capability of the system's spectral CT, the Bayesian eigentissue decomposition (ETD) method was utilized to quantitatively decompose the virtual noncontrast (VNC) electron densities and iodine contrast agent fractions in the Kidney1 inserts mixed with the iodine contrast agent within the simulated phantoms. The performance of the proposed quad-model imaging in the platform was validated by imaging a simulated phantom with multiple imaging probes, including an iodine contrast agent and radioisotopes of 18F and 99mTc. RESULTS: The PET subsystem demonstrated an absolute peak sensitivity of 18.5% at the scanner center, with an energy window of 175-560 KeV, and a scatter fraction of only 3.5% for the mouse phantom, with a default energy window of 480-540 KeV. The spatial resolution of PET on-board imaging exceeded 1.2 mm. All imaging probes were identified clearly within the phantom. The PET and SPECT images agreed well with the actual spatial distributions of the tracers within the phantom. Average relative errors on electron density and iodine contrast agent fraction in the Kidney1 inserts were less than 3%. High-quality PET images, SPECT images, spectral-CT images (including iodine contrast agent fraction images and VNC electron density images), and CBCT images of the simulated phantom demonstrated the comprehensive multimodal imaging capability of the system. CONCLUSIONS: The results demonstrated the feasibility of the proposed quad-modal imaging configuration in a SART platform. The design incorporates anatomical, molecular, and functional information about tumors, thereby facilitating successful translation of preclinical studies into clinical practices.


Assuntos
Iodo , Tomografia Computadorizada de Feixe Cônico Espiral , Camundongos , Animais , Meios de Contraste , Teorema de Bayes , Tomografia por Emissão de Pósitrons/métodos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Imagens de Fantasmas , Método de Monte Carlo
9.
Eur Radiol ; 34(8): 5131-5141, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38189979

RESUMO

OBJECTIVES: To investigate intra-patient variability of iodine concentration (IC) between three different dual-energy CT (DECT) platforms and to test different normalization approaches. METHODS: Forty-four patients who underwent portal venous phase abdominal DECT on a dual-source (dsDECT), a rapid kVp switching (rsDECT), and a dual-layer detector platform (dlDECT) during cancer follow-up were retrospectively included. IC in the liver, pancreas, and kidneys and different normalized ICs (NICPV:portal vein; NICAA:abdominal aorta; NICALL:overall iodine load) were compared between the three DECT scanners for each patient. A longitudinal mixed effects analysis was conducted to elucidate the effect of the scanner type, scan order, inter-scan time, and contrast media amount on normalized iodine concentration. RESULTS: Variability of IC was highest in the liver (dsDECT vs. dlDECT 28.96 (14.28-46.87) %, dsDECT vs. rsDECT 29.08 (16.59-62.55) %, rsDECT vs. dlDECT 22.85 (7.52-33.49) %), and lowest in the kidneys (dsDECT vs. dlDECT 15.76 (7.03-26.1) %, dsDECT vs. rsDECT 15.67 (8.86-25.56) %, rsDECT vs. dlDECT 10.92 (4.92-22.79) %). NICALL yielded the best reduction of IC variability throughout all tissues and inter-scanner comparisons, yet did not reduce the variability between dsDECT vs. dlDECT and rsDECT, respectively, in the liver. The scanner type remained a significant determinant for NICALL in the pancreas and the liver (F-values, 12.26 and 23.78; both, p < 0.0001). CONCLUSIONS: We found tissue-specific intra-patient variability of IC across different DECT scanner types. Normalization mitigated variability by reducing physiological fluctuations in iodine distribution. After normalization, the scanner type still had a significant effect on iodine variability in the pancreas and liver. CLINICAL RELEVANCE STATEMENT: Differences in iodine quantification between dual-energy CT scanners can partly be mitigated by normalization, yet remain relevant for specific tissues and inter-scanner comparisons, which should be taken into account at clinical routine imaging. KEY POINTS: • Iodine concentration showed the least variability between scanner types in the kidneys (range 10.92-15.76%) and highest variability in the liver (range 22.85-29.08%). • Normalizing tissue-specific iodine concentrations against the overall iodine load yielded the greatest reduction of variability between scanner types for 2/3 inter-scanner comparisons in the liver and for all (3/3) inter-scanner comparisons in the kidneys and pancreas, respectively. • However, even after normalization, the dual-energy CT scanner type was found to be the factor significantly influencing variability of iodine concentration in the liver and pancreas.


Assuntos
Meios de Contraste , Iodo , Rim , Fígado , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Tomografia Computadorizada por Raios X , Humanos , Feminino , Masculino , Tomografia Computadorizada por Raios X/métodos , Pessoa de Meia-Idade , Estudos Retrospectivos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Idoso , Rim/diagnóstico por imagem , Fígado/diagnóstico por imagem , Pâncreas/diagnóstico por imagem , Adulto
10.
Med Phys ; 51(2): 1047-1060, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37469179

RESUMO

BACKGROUND: Image quality of photon-counting and energy integrating CT scanners changes with object size, dose to the object, and kernel selection. PURPOSE: To comprehensively compare task-generic image quality of photon-counting CT (PCCT) and energy integrating CT (EICT) systems as a function of phantom size, dose, and reconstruction kernel. METHODS: A size-variant phantom (Mercury Phantom 3.0) was used to characterize the image quality of PCCT and EICT systems as a function of object size. The phantom contained five cylinders attached by slanted tapered sections. Each cylinder contained two sections: one uniform for noise, and the other with inserts for spatial resolution and contrast measurements. The phantom was scanned on Siemens' SOMATOM Force and NAEOTOM Alpha at 1.18 and 7.51 mGy without tube current modulation. CTDIvol was matched across two systems by setting the required tube currents, else, all other acquisition settings were fixed. CT sinograms were reconstructed using FBP and iterative (ADMIRE2 - Force; QIR2 - Alpha) algorithms with Body regular (Br) kernels. Noise Power Spectrum (NPS), Task Transfer Function (TTF), contrast-to-noise ratio (CNR), and detectability index (d') for a task of identifying 2-mm disk were evaluated based on AAPM TG-233 metrology using imQuest, an open-source software package. Averaged noise frequency (fav ) and 50% cut-off frequency for TTF (f50 ) were used as scalar metrics to quantify noise texture and spatial resolution, respectively. The difference between image quality metrics' measurements was calculated as IQPCCT - IQEICT . RESULTS: From Br40 (soft) to Br64 (sharp), f50 for air insert increased from 0.35 mm-1  ± 0.04 (standard deviation) to 0.76 mm-1  ± 0.17, 0.34 mm-1  ± 0.04 to 0.77 mm-1  ± 0.17, 0.37 mm-1  ± 0.02 to 0.95 mm-1  ± 0.17 for PCCT-T3D-QIR2, PCCT-70keV-QIR2, and EICT-ADMIRE2, respectively, when averaged over all sizes and dose levels. Similarly, from Br40 to Br64, noise magnitude increased from 10.86 HU ± 7.12 to 38.61 HU ± 18.84, 10.94 HU ± 7.08 to 38.82 HU ± 18.70, 13.74 HU ± 11.02 to 52.11 HU ± 26.22 for PCCT-T3D-QIR2, PCCT-70keV-QIR2, and EICT-ADMIRE2, respectively. The difference in fav was consistent across all sizes and dose levels. PCCT-70keV-VMI showed better consistency in contrast measurements for iodine and bone inserts than PCCT-T3D and EICT; however, PCCT-T3D had higher contrast for both inserts. From Br40 to Br64, considering all sizes and dose levels, CNR for iodine insert decreased from 52.30 ± 46.44 to 12.18 ± 10.07, 40.42 ± 33.42 to 9.48 ± 7.16, 39.94 ± 37.60 to 7.84 ± 6.67 for PCCT-T3D-QIR2, PCCT-70keV-QIR2, and EICT-ADMIRE2, respectively. CONCLUSIONS: Both PCCT image types, T3D and 70-keV-VMI exhibited similar or better noise, contrast, CNR than EICT when comparing kernels with similar names. For 512 × 512 matrix, PCCT's sharp kernels had lower resolution than EICT's sharp kernels. For all image quality metrics, except extreme low, every dose condition had a similar set of IQ-matching kernels. It suggests that considering patient size and dose level to determine IQ-matching kernel pairs across PCCT and EICT systems may not be imperative while translating protocols, except when the signal to the detector is extremely low.


Assuntos
Iodo , Tomografia Computadorizada por Raios X , Humanos , Tomografia Computadorizada por Raios X/métodos , Tomógrafos Computadorizados , Imagens de Fantasmas , Algoritmos , Doses de Radiação
11.
Abdom Radiol (NY) ; 49(1): 271-278, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37814149

RESUMO

PURPOSE: To determine optimal iodine density thresholds for active inflammation in CD patients with PCCT enterography and determine if iodine density can be used to stratify CD activity severity. METHODS: A retrospective PACS search identified patients with CD imaged with PCCT enterography from 4/11/2022 to 10/30/2022 and with clinical notes, endoscopic/surgical pathology and available source PCCT data for iodine density analysis. Two abdominal radiologists with expertise in CD each drew two region of interest measurements within the visibly most affected region of terminal or neoterminal ileum wall on commercially available system (SyngoVia). Radiologists were blinded to clinical information and pathologic findings. Disease activity and severity were recorded from the pathology report. Harvey-Bradshaw Index, medications, and laboratory values were recorded. Receiver operating characteristic (ROC) curves were utilized to determine the optimum iodine density threshold for active inflammation and mild versus moderate-to-severe inflammation. Intra- and inter-reader agreement was assessed by intra-class correlation coefficient (ICC). RESULTS: 23 CD patients (15 females; mean [SD] age: 52 [17] years) imaged with PCCT enterography were included. 15/23 had active inflammation: 9/15 mild, 4/15 moderate, and 2/15 severe active inflammation. The optimal iodine density threshold for active inflammation was 2.7 mg/mL, with 97% sensitivity, 100% specificity, and 98% accuracy (AUC = 1.00). The optimal iodine density threshold for distinguishing mild from moderate-to-severe inflammation was 3.4 mg/mL, with 83% sensitivity, 89% specificity, and 87% accuracy (AUC = 0.85). Intra-reader reliability (R1/R2) ICC was 0.81/0.86. Inter-reader reliability ICC was 0.94. CONCLUSION: Iodine density from PCCT enterography can distinguish mild from moderate-to-severe active inflammation.


Assuntos
Doença de Crohn , Iodo , Feminino , Humanos , Pessoa de Meia-Idade , Doença de Crohn/diagnóstico por imagem , Doença de Crohn/patologia , Estudos Retrospectivos , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X/métodos , Inflamação/diagnóstico por imagem , Inflamação/patologia
12.
J Comput Assist Tomogr ; 48(1): 104-109, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37566794

RESUMO

OBJECTIVE: Pulse pileup effects occur when pulses occur so close together that they fall on top of one another, resulting in count loss and errors in energy thresholding. To date, there has been little work systematically detailing the quantitative effects of pulse pileup on material decomposition accuracy for photon-counting detector (PCD) computed tomography (CT). Our aim in this work was to quantify the effects of pulse pileup on single-energy and multienergy CT images, including low-energy bin (BL), high-energy bin (BH), iodine map, and virtual noncontrast images from a commercial PCD-CT. METHODS: Scans of a 20-cm diameter multienergy CT phantom with 10 solid inserts were acquired at a fixed tube potential as the tube current was varied across the available range. Four types of images (BL, BH, iodine map, and virtual noncontrast) were reconstructed using an iterative reconstruction algorithm at strength 2, a quantitative reconstruction kernel (Qr40), 2-/1-mm slice thickness/increment, and a 210-mm field-of-view. The mean and standard deviation of CT numbers were recorded and the ratios of CT number between BL and BH images were calculated and plotted, along with noise versus tube current and noise × versus tube current. RESULTS: As tube current was increased, the range of variations in CT numbers was less than 13.4 HU for all inserts and image types evaluated. Noise × versus tube current showed a small positive slope equal to a noise increase from 100 mA of 10% at 500 mA and 15% at 900 mA compared with what would be expected if the slope was zero. CONCLUSIONS: Minimal impact on single-energy and multienergy CT numbers and noise performance was observed for the evaluated clinical PCD-CT system.


Assuntos
Iodo , Fótons , Humanos , Tomografia Computadorizada por Raios X/métodos , Imagens de Fantasmas , Algoritmos
13.
Endocr Pract ; 30(2): 172-176, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37956907

RESUMO

A wide variety of thyroidal endocrine-disrupting chemicals (EDCs) have been identified. Exposure to known thyroidal EDCs is ubiquitous, and many likely remain unidentified. The sources of exposure include contaminated drinking water, air pollution, pesticides and agricultural chemicals, flame retardants, cleaning supplies, personal care products, food additives and packaging materials, coatings and solvents, and medical products and equipment. EDCs can affect thyroid hormone synthesis, transport, metabolism, and action in a myriad of ways. Understanding the health effects of thyroidal EDCs has been challenging because individuals may have multiple concomitant EDC exposures and many potential EDCs are not yet well characterized. Because of the importance of thyroid hormone for brain development in early life, pregnant women and young infants are particularly vulnerable to the effects of environmental thyroid disruption. The thyroidal effects of some EDCs may be exacerbated in iodine-deficient individuals, those with thyroid autoimmunity, and those with mutations in deiodinase genes. Differential exposures to EDCs may exacerbate health disparities in disadvantaged groups. High-throughput in vitro assays and in silico methods and methods that can detect the effects of relevant EDC mixtures are needed. In addition, optimal methods for detecting the effects of thyroidal EDCs on neurodevelopment need to be developed. Common sense precautions can reduce some thyroidal EDC exposures; however, regulation of manufacturing and drinking water content will ultimately be needed to protect populations.


Assuntos
Água Potável , Disruptores Endócrinos , Iodo , Lactente , Humanos , Gravidez , Feminino , Glândula Tireoide , Disruptores Endócrinos/toxicidade , Água Potável/efeitos adversos , Hormônios Tireóideos
14.
Med Phys ; 51(4): 2479-2498, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37967277

RESUMO

BACKGROUND: Contrast-enhanced spectral mammography (CESM) with photon-counting x-ray detectors (PCDs) can be used to improve the classification of breast cancers as benign or malignant. Commercially-available PCD-based mammography systems use silicon-based PCDs. Cadmium-telluride (CdTe) PCDs may provide a practical advantage over silicon-based PCDs because they can be implemented as large-area detectors that are more easily adaptable to existing mammography systems. PURPOSE: The purpose of this work is to optimize CESM implemented with CdTe PCDs and to investigate the influence of the number of energy bins, electronic noise level, pixel size, and anode material on image quality. METHODS: We developed a Monte Carlo model of the energy-bin-dependent modulation transfer functions (MTFs) and noise power spectra, including spatioenergetic noise correlations. We validated model predictions using a CdTe PCD with analog charge summing for charge-sharing suppression. Using the ideal-observer detectability, we optimized CESM for the task of detecting a 7-mm-diameter iodine nodule embedded in a breast with 50% glandularity. We optimized the tube voltage, beam filtration, and the location of energy thresholds for 50 and 100- µ $\mu$ m pixels, tungsten and molybdenum anodes, and two electronic noise levels. One of the electronic noise levels was that of the experimental system; the other was half that of the experimental system. Optimization was performed for CdTe PCDs with two or three energy bins. We also estimated the impact of anatomic noise due to background parenchymal enhancement and computed the minimum detectable iodine area density in the presence of quantum and anatomic noise. RESULTS: Model predictions of the MTFs and noise power spectra agreed well with experiment. For optimized systems, adding a third energy bin increased quantum noise levels and reduced detectability by ∼55% compared to two-bin approaches that simply suppress contrast between fibroglandular and adipose tissue. Decreasing the electronic noise standard deviation from 3.4 to 1.7 keV increased iodine detectability by ∼5% and ∼30% for two-bin imaging and three-bin imaging, respectively. After optimizing for tube voltage, beam filtration, and the location of energy thresholds, there was ∼a 3% difference in iodine detectability between molybdenum and tungsten anodes for two-bin imaging, but for three-bin imaging, molybdenum anodes provided up to 14% increase in detectability relative to tungsten anodes. Anatomic noise decreased iodine detectability by 15% to 40%, with greater impact for lower electronic noise settings and larger pixel sizes. CONCLUSIONS: For CESM implemented with CdTe PCDs, (1) quantitatively-accurate three-material decompositions using three energy bins are associated with substantial increases in quantum noise relative to two-energy-bin approaches that simply suppress contrast between fibroglandular and adipose tissues; (2) tungsten and molybdenum anodes can provide nearly equal iodine detectability for two-bin imaging, but molybdenum provides a modest detectability advantage for three-bin imaging provided that all other technique parameters are optimized; (3) reducing pixel sizes from 100 to 50  µ $\mu$ m can reduce detectability by up to 20% due to charge sharing; (4) anatomic noise due to background parenchymal enhancement is estimated to have a substantial impact on lesion visibility, reducing detectability by approximately 30%.


Assuntos
Compostos de Cádmio , Iodo , Pontos Quânticos , Raios X , Telúrio , Tomografia Computadorizada por Raios X/métodos , Molibdênio , Silício , Tungstênio , Mamografia , Fótons
15.
Artigo em Inglês | MEDLINE | ID: mdl-38083590

RESUMO

The use of contrast-enhanced computed tomography (CTCA) for detection of coronary artery disease (CAD) exposes patients to the risks of iodine contrast-agents and excessive radiation, increases scanning time and healthcare costs. Deep learning generative models have the potential to artificially create a pseudo-enhanced image from non-contrast computed tomography (CT) scans.In this work, two specific models of generative adversarial networks (GANs) - the Pix2Pix-GAN and the Cycle-GAN - were tested with paired non-contrasted CT and CTCA scans from a private and public dataset. Furthermore, an exploratory analysis of the trade-off of using 2D and 3D inputs and architectures was performed. Using only the Structural Similarity Index Measure (SSIM) and the Peak Signal-to-Noise Ratio (PSNR), it could be concluded that the Pix2Pix-GAN using 2D data reached better results with 0.492 SSIM and 16.375 dB PSNR. However, visual analysis of the output shows significant blur in the generated images, which is not the case for the Cycle-GAN models. This behavior can be captured by the evaluation of the Fréchet Inception Distance (FID), that represents a fundamental performance metric that is usually not considered by related works in the literature.Clinical relevance- Contrast-enhanced computed tomography is the first line imaging modality to detect CAD resulting in unnecessary exposition to the risk of iodine contrast and radiation in particularly in young patients with no disease. This algorithm has the potential of being translated into clinical practice as a screening method for CAD in asymptomatic subjects or quick rule-out method of CAD in the acute setting or centres with no CTCA service. This strategy can eventually represent a reduction in the need for CTCA reducing its burden and associated costs.


Assuntos
Doença da Artéria Coronariana , Iodo , Humanos , Processamento de Imagem Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Doença da Artéria Coronariana/diagnóstico por imagem , Custos de Cuidados de Saúde
16.
Eur Radiol Exp ; 7(1): 72, 2023 11 21.
Artigo em Inglês | MEDLINE | ID: mdl-37985560

RESUMO

Metabolic dysfunction-associated fatty liver disease (MAFLD), previously called metabolic nonalcoholic fatty liver disease, is the most prevalent chronic liver disease worldwide. The multi-factorial nature of MAFLD severity is delineated through an intricate composite analysis of the grade of activity in concert with the stage of fibrosis. Despite the preeminence of liver biopsy as the diagnostic and staging reference standard, its invasive nature, pronounced interobserver variability, and potential for deleterious effects (encompassing pain, infection, and even fatality) underscore the need for viable alternatives. We reviewed computed tomography (CT)-based methods for hepatic steatosis quantification (liver-to-spleen ratio; single-energy "quantitative" CT; dual-energy CT; deep learning-based methods; photon-counting CT) and hepatic fibrosis staging (morphology-based CT methods; contrast-enhanced CT biomarkers; dedicated postprocessing methods including liver surface nodularity, liver segmental volume ratio, texture analysis, deep learning methods, and radiomics). For dual-energy and photon-counting CT, the role of virtual non-contrast images and material decomposition is illustrated. For contrast-enhanced CT, normalized iodine concentration and extracellular volume fraction are explained. The applicability and salience of these approaches for clinical diagnosis and quantification of MAFLD are discussed.Relevance statementCT offers a variety of methods for the assessment of metabolic dysfunction-associated fatty liver disease by quantifying steatosis and staging fibrosis.Key points• MAFLD is the most prevalent chronic liver disease worldwide and is rapidly increasing.• Both hardware and software CT advances with high potential for MAFLD assessment have been observed in the last two decades.• Effective estimate of liver steatosis and staging of liver fibrosis can be possible through CT.


Assuntos
Iodo , Hepatopatia Gordurosa não Alcoólica , Humanos , Hepatopatia Gordurosa não Alcoólica/diagnóstico por imagem , Cirrose Hepática , Tomografia Computadorizada por Raios X
17.
Nutrients ; 15(20)2023 Oct 20.
Artigo em Inglês | MEDLINE | ID: mdl-37892522

RESUMO

Mild-to-moderate iodine deficiency during pregnancy is prevalent worldwide, but its consequences for maternal and child health are not clear. We aimed to investigate the impact of maternal iodine intake during pregnancy on the child's growth and neurodevelopment. This study involved a cohort of 11-year-old children (n = 70) whose mothers had participated in an iodine intake survey during pregnancy. Gestational, neonatal, anthropometric, intelligence quotient (IQ), and socioeconomic parameters were analyzed according to maternal urinary iodine concentration (UIC). There was a positive linear trend of current height Z-score, full-scale IQ, verbal IQ, family income, maternal education, and a negative trend of neonatal TSH levels with increasing maternal UIC levels. However, regression analysis indicated that maternal UIC was not an independent predictor of any gestational, neonatal, or childhood development parameter. Only maternal school education was positively associated with child height and IQ. In conclusion, we did not find any evidence of a direct effect of maternal iodine intake during pregnancy on the long-term growth and neurodevelopment of children. The results suggest that socioeconomic factors are important confounding factors that affect both maternal iodine intake and child development and must be considered when investigating the association between maternal iodine intake and child outcomes.


Assuntos
Iodo , Gravidez , Feminino , Recém-Nascido , Humanos , Criança , Seguimentos , Desenvolvimento Infantil , Mães , Estado Nutricional
18.
J Radiol Prot ; 43(4)2023 11 02.
Artigo em Inglês | MEDLINE | ID: mdl-37857280

RESUMO

Age-specific dose coefficients are required to assess internal exposure to the general public. This study utilizes reference age-specific biokinetic models of iodine to estimate the total number of nuclear disintegrations ã(rS,τ) occurring in source regions (rS) during the commitment time (τ). Age-specific S values are estimated for 35 target regions due to131I present in 22rSusing data from 10 paediatric reference computational phantoms (representing five ages for both sexes) published recently by the International Commission of Radiation Protection (ICRP). Monte Carlo transport simulations are performed in FLUKA code. The estimated ã(rS,τ) and S values are then used to compute the committed tissue equivalent dose HT(τ) for 27 radiosensitive tissues and dose coefficients e(τ) for all five ages due to inhalation and ingestion of131I. The derived ã(rS,τ) values in the thyroid source are observed to increase with age due to the increased retention of iodine in the thyroid. S values are found to decrease with age, mainly due to an increase in target masses. Generally, HT(τ) values are observed to decrease with age, indicating the predominant behaviour of S values over ã(rS,τ). On average, ingestion dose coefficients are 63% higher than for inhalation in all ages. The maximum contribution to dose coefficients is from the thyroid, accounting for 96% in the case of newborns and 98%-99% for all other ages. Furthermore, the estimated e(τ) values for the reference population are observed to be lower than previously published reference values from the ICRP. The estimated S, HT(τ) and e(τ) values can be used to improve estimations of internal doses to organs/whole body for members of the public in cases of131I exposure. The estimated dose coefficients can also be interpolated for other ages to accurately evaluate the doses received by the general public during131I therapy or during a radiological emergency.


Assuntos
Radioisótopos do Iodo , Iodo , Masculino , Feminino , Humanos , Criança , Recém-Nascido , Doses de Radiação , Radioisótopos do Iodo/análise , Imagens de Fantasmas , Método de Monte Carlo , Fatores Etários , Radiometria
19.
Probl Endokrinol (Mosk) ; 69(4): 38-49, 2023 08 30.
Artigo em Russo | MEDLINE | ID: mdl-37694866

RESUMO

Iodine deficiency disorders (IDD) are prevalent and highly morbidity, have hidden progression, severe disabling somatic complications, including cognitive disorders, reproductive losses, and oncopathology. This presents a serious challenge to the healthcare system of the Russian Federation, as it affects over 3 million people. The lack of relevant data on the severity of IDD and the current prevention programs at the regional level necessitates the need for appropriate research and measures in individual subjects of the Russian Federation. AIM: To conduct a comprehensive study to assess the current iodine security of the population of the Chechen Republic, to analyze the prevalence of thyroid pathology and compare it with official statistics, to formulate conclusions about the necessary preventive measures. MATERIALS AND METHODS: In the Chechen Republic, a total of 1239 people were examined, of which 921 were schoolchildren of pre-pubertal age (8-10 years) and 318 were adults. The survey of the adult population was carried out at medical organizations in four districts of the republic (Nadterechny, Shalinsky, Vedensky, Grozny) and included a questionnaire survey, a clinical examination by an endocrinologist with palpation of the thyroid gland, thyroid ultrasound, and a study by a qualitative method of samples of table salt used in households for the presence of iodine.Children's examinations were carried out by the cluster method on the basis of secondary schools in 9 out of 15 districts of the republic and included an examination by an endocrinologist and measurement of anthropometric parameters (height, weight), thyroid ultrasound to evaluate volume, determination of iodine concentration in single portions of urine and qualitative analysis of samples of table salt used in children's nutrition in families for the presence of iodine.The incidence and prevalence of thyroid disease among the population of the Chechen Republic were analyzed using data from official state statistics - form No. 12 «Information on the number of diseases registered in patients living in the area served by the medical institution¼ (ROSSTAT data as of 01.01.2021). RESULTS: According to the results of a survey of 921 pre-pubertal children, the median urinary iodine concentration was 71.3 µg/L (frequency of values below 50µg/L - 17,7%) and varies from 48.9 to 179.2 µg/L in the surveyed areas. According to thyroid ultrasound data, diffuse goiter was detected in 16.4% of the examined children, with goiter frequency ranging from 11.3% to 23.5%. The proportion of iodized salt consumed in schoolchildren's families was 4.2% in all study areas (range of values from 1.3% to 8%), which indicates an extremely low level of using iodized salt by household.According to the results of the examination of the adult population (n=318), structural changes in thyroid tissue were detected in 79.9% (n=254), while the proportion of nodular thyroid pathology being 83% (n=205), with a range of values across different districts of 52.5-80%. CONCLUSION: Based on the obtained data, according to WHO criteria, it can be stated that, overall, the degree of severity of iodine deficiency disorders in the Chechen Republic corresponds to mild severity with a tendency towards moderate severity in several districts of the foothills. The results of the examination of the adult population indicate a high prevalence of thyroid pathology, predominantly nodular, in the Chechen Republic. The data obtained in the course of large-scale research made it possible to initiate the development of necessary medical and organizational measures in the region - a program for the prevention of IDD.


Assuntos
Bócio , Iodo , Desnutrição , Adulto , Criança , Humanos , Cloreto de Sódio na Dieta , Bócio/epidemiologia , Bócio/prevenção & controle
20.
Micron ; 174: 103533, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37660476

RESUMO

Micro-computed tomography (micro-CT) provides valuable data for studying soft tissue, though it is often affected by sample movement during scans and low contrast in X-ray absorption. This can result in lower image quality and geometric inaccuracies, collectively known as 'artefacts'. To mitigate these issues, samples can be embedded in hydrogels and enriched with heavy metals for contrast enhancement. However, the long-term durability of these enhancements remains largely unexplored. In this study, we examine the effects of two contrast enhancement agents - iodine and phosphotungstic acid (PTA) - and two hydrogels - agarose and Poloxamer 407 - over a 14-day period. We used Drosophila melanogaster as a test model for our investigation. Our findings reveal that PTA and agarose are highly durable, while iodine and poloxamer hydrogel exhibits higher leakage rates. These observations lay the foundation for estimating contrast stabilities in contrast-enhanced micro-CT with hydrogel embedding and serve to inform future research in this field.


Assuntos
Hidrogéis , Iodo , Animais , Microtomografia por Raio-X , Drosophila melanogaster , Sefarose , Ácido Fosfotúngstico , Poloxâmero
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA