Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.734
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
Environ Monit Assess ; 196(5): 463, 2024 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-38642156

RESUMO

In this study, the levels of sulfur dioxide (SO2) and nitrogen dioxide (NO2) were measured indoors and outdoors using passive samplers in Tymar village (20 homes), an industrial area, and Haji Wsu (15 homes), a non-industrial region, in the summer and the winter seasons. In comparison to Haji Wsu village, the results showed that Tymar village had higher and more significant mean SO2 and NO2 concentrations indoors and outdoors throughout both the summer and winter seasons. The mean outdoor concentration of SO2 was the highest in summer, while the mean indoor NO2 concentration was the highest in winter in both areas. The ratio of NO2 indoors to outdoors was larger than one throughout the winter at both sites. Additionally, the performance of machine learning (ML) approaches: multiple linear regression (MLR), artificial neural network (ANN), and random forest (RF) were compared in predicting indoor SO2 concentrations in both the industrial and non-industrial areas. Factor analysis (FA) was conducted on different indoor and outdoor meteorological and air quality parameters, and the resulting factors were employed as inputs to train the models. Cross-validation was applied to ensure reliable and robust model evaluation. RF showed the best predictive ability in the prediction of indoor SO2 for the training set (RMSE = 2.108, MAE = 1.780, and R2 = 0.956) and for the unseen test set (RMSE = 4.469, MAE = 3.728, and R2 = 0.779) values compared to other studied models. As a result, it was observed that the RF model could successfully approach the nonlinear relationship between indoor SO2 and input parameters and provide valuable insights to reduce exposure to this harmful pollutant.


Assuntos
Poluentes Atmosféricos , Poluição do Ar em Ambientes Fechados , Poluição do Ar , Dióxido de Enxofre/análise , Dióxido de Nitrogênio/análise , Poluentes Atmosféricos/análise , Monitoramento Ambiental/métodos , Poluição do Ar/análise , Estações do Ano , Poluição do Ar em Ambientes Fechados/análise
2.
Sci Total Environ ; 927: 172278, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38583631

RESUMO

The Wells-Riley model is extensively used for retrospective and prospective modelling of the risk of airborne transmission of infection in indoor spaces. It is also used when examining the efficacy of various removal and deactivation methods for airborne infectious aerosols in the indoor environment, which is crucial when selecting the most effective infection control technologies. The problem is that the large variation in viral load between individuals makes the Wells-Riley model output very sensitive to the input parameters and may yield a flawed prediction of risk. The absolute infection risk estimated with this model can range from nearly 0 % to 100 % depending on the viral load, even when all other factors, such as removal mechanisms and room geometry, remain unchanged. We therefore propose a novel method that removes this sensitivity to viral load. We define a quanta-independent maximum absolute before-after difference in infection risk that is independent of quanta factors like viral load, physical activity, or the dose-response relationships. The input data needed for a non-steady-state calculation are just the removal rates, room volume, and occupancy duration. Under steady-state conditions the approach provides an elegant solution that is only dependent on removal mechanisms before and after applying infection control measures. We applied this method to compare the impact of relative humidity, ventilation rate and its effectiveness, filtering efficiency, and the use of ultraviolet germicidal irradiation on the infection risk. The results demonstrate that the method provides a comprehensive understanding of the impact of infection control strategies on the risk of airborne infection, enabling rational decisions to be made regarding the most effective strategies in a specific context. The proposed method thus provides a practical tool for mitigation of airborne infection risk.


Assuntos
Microbiologia do Ar , Poluição do Ar em Ambientes Fechados , Humanos , Poluição do Ar em Ambientes Fechados/prevenção & controle , Aerossóis/análise , COVID-19/prevenção & controle , COVID-19/transmissão , Ventilação , Carga Viral , Modelos Teóricos , Controle de Infecções/métodos , Medição de Risco
3.
J Hazard Mater ; 471: 134307, 2024 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-38678702

RESUMO

This systematic review and meta-analysis investigated studies on formaldehyde (FA) inhalation exposure in indoor environments and related carcinogenic (CR) and non-carcinogenic (HQ) risk. Studies were obtained from Scopus, PubMed, Web of Science, Medline, and Embase databases without time limitation until November 21, 2023. Studies not meeting the criteria of Population, Exposure, Comparator, and Outcomes (PECO) were excluded. The 45 articles included belonged to the 5 types of sites: dwelling environments, educational centers, kindergartens, vehicle cabins, and other indoor environments. A meta-analysis determined the average effect size (ES) between indoor FA concentrations, CR, and HQ values in each type of indoor environment. FA concentrations ranged from 0.01 to 1620 µg/m3. The highest FA concentrations were stated in water pipe cafés and the lowest in residential environments. In more than 90% of the studies uncertain (1.00 ×10-6 1.00 ×10-4) due to FA inhalation exposure was reported and non-carcinogenic risk was stated acceptable. The meta-analysis revealed the highest CR values due to inhalation of indoor FA in high-income countries. As 90% of the time is spent indoors, it is crucial to adopt effective strategies to reduce FA concentrations, especially in kindergartens and schools, with regular monitoring of indoor air quality.


Assuntos
Poluição do Ar em Ambientes Fechados , Formaldeído , Exposição por Inalação , Formaldeído/análise , Formaldeído/toxicidade , Poluição do Ar em Ambientes Fechados/análise , Exposição por Inalação/análise , Medição de Risco , Humanos
4.
Front Public Health ; 12: 1348234, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38590814

RESUMO

China is actively encouraging households to replace traditional solid fuels with clean energy. Based on the Chinese Families Panel Survey (CFPS) data, this paper uses propensity scores matching with the difference-in-differences model to examine the impact of clean energy in the household sector on residents' health status, and whether such an energy transition promotes health equity by favoring relatively disadvantaged social groups. The results show that: (1) The use of cleaner cooking fuels can significantly improve residents' health status; (2) The older adult and women have higher health returns from the clean energy transition, demonstrating that, from the perspective of age and gender, the energy transition contributes to the promotion of health equity; (3) The clean energy transition has a lower or insignificant health impact on residents who cannot easily obtain clean energy or replace non-clean energy at an affordable price. Most of these individuals live in low-income, energy-poor, or rural households. Thus, the energy transition exacerbates health inequalities. This paper suggests that to reduce the cost of using clean energy and help address key issues in health inequality, Chinese government efforts should focus on improving the affordability, accessibility, and reliability of clean energy.


Assuntos
Poluição do Ar em Ambientes Fechados , Humanos , Feminino , Idoso , Poluição do Ar em Ambientes Fechados/análise , Disparidades nos Níveis de Saúde , Reprodutibilidade dos Testes , China , Desigualdades de Saúde
5.
Environ Pollut ; 350: 123976, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38657893

RESUMO

The lack of knowledge regarding the extent of microbial contamination in Portuguese fitness centers (FC) puts attendees and athletes at risk for bioaerosol exposure. This study intends to characterize microbial contamination in Portuguese FC by passive sampling methods: electrostatic dust collectors (EDC) (N = 39), settled dust (N = 8), vacuum filters (N = 8), and used cleaning mops (N = 12). The obtained extracts were plated in selective culture media for fungi and bacteria. Filters, EDC, and mop samples' extracts were also screened for antifungal resistance and used for the molecular detection of the selected Aspergillus sections. The detection of mycotoxins was conducted using a high-performance liquid chromatograph (HPLC) system and to determine the cytotoxicity of microbial contaminants recovered by passive sampling, HepG2 (human liver carcinoma) and A549 (human alveolar epithelial) cells were employed. The results reinforce the use of passive sampling methods to identify the most critical areas and identify environmental factors that influence microbial contamination, namely having a swimming pool. The cardio fitness area presented the highest median value of total bacteria (TSA: 9.69 × 102 CFU m-2.day-1) and Gram-negative bacteria (VRBA: 1.23 CFU m-2.day-1), while for fungi it was the open space area, with 1.86 × 101 CFU m-2.day-1. Aspergillus sp. was present in EDC and in filters used to collect settled dust. Reduced azole susceptibility was observed in filters and EDC (on ICZ and VCZ), and in mops (on ICZ). Fumonisin B2 was the only mycotoxin detected and it was present in all sampling matrixes except settled dust. High and moderate cytotoxicity was obtained, suggesting that A549 cells were more sensitive to samples' contaminants. The observed widespread of critical toxigenic fungal species with clinical relevance, such as Aspergillus section Fumigati, as well as Fumonisin B2 emphasizes the importance of frequent and effective cleaning procedures while using shared mops appeared as a vehicle of cross-contamination.


Assuntos
Microbiologia do Ar , Monitoramento Ambiental , Fungos , Portugal , Humanos , Monitoramento Ambiental/métodos , Poluição do Ar em Ambientes Fechados/análise , Poluição do Ar em Ambientes Fechados/estatística & dados numéricos , Micotoxinas/análise , Poeira/análise , Células Hep G2 , Células A549 , Bactérias/isolamento & purificação
6.
J Hazard Mater ; 470: 134159, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38565018

RESUMO

Household air pollution prevails in rural residences across China, yet a comprehensive nationwide comprehending of pollution levels and the attributable disease burdens remains lacking. This study conducted a systematic review focusing on elucidating the indoor concentrations of prevalent household air pollutants-specifically, PM2.5, PAHs, CO, SO2, and formaldehyde-in rural Chinese households. Subsequently, the premature deaths and economic losses attributable to household air pollution among the rural population of China were quantified through dose-response relationships and the value of statistical life. The findings reveal that rural indoor air pollution levels frequently exceed China's national standards, exhibiting notable spatial disparities. The estimated annual premature mortality attributable to household air pollution in rural China amounts to 966 thousand (95% CI: 714-1226) deaths between 2000 and 2022, representing approximately 22.2% (95% CI: 16.4%-28.1%) of total mortality among rural Chinese residents. Furthermore, the economic toll associated with these premature deaths is estimated at 486 billion CNY (95% CI: 358-616) per annum, constituting 0.92% (95% CI: 0.68%-1.16%) of China's GDP. The findings quantitatively demonstrate the substantial disease burden attributable to household air pollution in rural China, which highlights the pressing imperative for targeted, region-specific interventions to ameliorate this pressing public health concern.


Assuntos
Poluição do Ar em Ambientes Fechados , População Rural , China/epidemiologia , Humanos , Poluição do Ar em Ambientes Fechados/efeitos adversos , Poluição do Ar em Ambientes Fechados/análise , População Rural/estatística & dados numéricos , Efeitos Psicossociais da Doença , Poluentes Atmosféricos/análise , Mortalidade Prematura , Modelos Teóricos , Exposição Ambiental/efeitos adversos
7.
J Occup Environ Hyg ; 21(5): 311-318, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38560887

RESUMO

Improving asthma outcomes for underserved populations can be addressed through interventions to improve indoor air quality (IAQ). New protocol for measuring IAQ and health outcomes are imperative given advances in IAQ monitoring technology and challenges in conducting intervention research in homes. In this pilot study HEPA air purifiers and HEPA vacuum cleaners were provided to five homes with children with asthma. For 6 weeks, eight common components of air quality were measured using a low-cost multi-channel air quality monitoring device, with data conveyed directly from participant homes via Wi-Fi connection. In conjunction with periodic surveys on asthma control, impact of asthma on quality of life and intervention compliance, outcomes compared IAQ, home characteristics, and asthma-related measures. This pilot study demonstrates the feasibility of a protocol to evaluate a dual component intervention to improve IAQ in homes, as measured with a low-cost air quality monitoring device.


Assuntos
Poluição do Ar em Ambientes Fechados , Asma , Monitoramento Ambiental , Estudos de Viabilidade , Humanos , Poluição do Ar em Ambientes Fechados/análise , Monitoramento Ambiental/métodos , Monitoramento Ambiental/instrumentação , Projetos Piloto , Criança , Habitação , Feminino , Masculino , Qualidade de Vida , Filtros de Ar
8.
J Radiol Prot ; 44(2)2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38632901

RESUMO

The high radon concentrations measured in the indoor air of groundwater facilities and the prevalence of the problem have been known for several years. Unlike in other workplaces, in groundwater plants, radon is released into the air from the water treatment processes. During the measurements of this study, the average radon concentrations varied from 500 to 8800 Bq m-3. In addition, the indoor air of the treatment plants is filtered and there are no significant internal aerosol sources. However, only a few published studies on groundwater plants have investigated the properties of the radon progeny aerosol, such as the equilibrium factor (F) or the size distribution of the aerosol, which are important for assessing the dose received by workers. Moreover, the International Commission on Radiological Protection has not provided generic aerosol parameter values for dose assessment in groundwater treatment facilities. In this study, radon and radon progeny measurements were carried out at three groundwater plants. The results indicate surprisingly high unattached fractions (fp= 0.27-0.58), suggesting a low aerosol concentration in indoor air. The correspondingFvalues were 0.09-0.42, well below those measured in previous studies. Based on a comparison of the effective dose rate calculations, either the determination of thefpor, with certain limitations, the measurement of radon is recommended. Dose rate calculation based on the potential alpha energy concentration alone proved unreliable.


Assuntos
Poluentes Radioativos do Ar , Poluição do Ar em Ambientes Fechados , Água Subterrânea , Monitoramento de Radiação , Radônio , Humanos , Produtos de Decaimento de Radônio/análise , Poluentes Radioativos do Ar/análise , Radônio/análise , Aerossóis , Monitoramento de Radiação/métodos , Poluição do Ar em Ambientes Fechados/análise
9.
Sci Total Environ ; 927: 172132, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38569952

RESUMO

This study investigated the occurrence and distribution of per- and polyfluoroalkyl substances (PFASs) in house dust samples from six regions across four continents. PFASs were detected in all indoor dust samples, with total median concentrations ranging from 17.3 to 197 ng/g. Among the thirty-one PFAS analytes, eight compounds, including emerging PFASs, exhibited high detection frequencies in house dust from all six locations. The levels of PFASs varied by region, with higher concentrations found in Adelaide (Australia), Tianjin (China), and Carbondale (United States, U.S.). Moreover, PFAS composition profiles also differed among regions. Dust from Australia and the U.S. contained high levels of 6:2 fluorotelomer phosphate ester (6:2 diPAP), while perfluorooctanoic acid (PFOA) and perfluorooctane sulfonic acid (PFOS) were predominant in other regions. Furthermore, our results indicate that socioeconomic factors impact PFAS levels. The assessment of human exposure through dust ingestion and dermal contact indicates that toddlers may experience higher exposure levels than adults. However, the hazard quotients of PFASs for both toddlers and adults were below one, indicating significant health risks are unlikely. Our study highlights the widespread occurrence of PFASs in global indoor dust and the need for continued monitoring and regulation of these chemicals.


Assuntos
Poluição do Ar em Ambientes Fechados , Poeira , Exposição Ambiental , Monitoramento Ambiental , Fluorocarbonos , Poeira/análise , Humanos , Poluição do Ar em Ambientes Fechados/análise , Poluição do Ar em Ambientes Fechados/estatística & dados numéricos , Fluorocarbonos/análise , Exposição Ambiental/estatística & dados numéricos , Exposição Ambiental/análise , Poluentes Atmosféricos/análise , Caprilatos/análise , Ácidos Alcanossulfônicos/análise , Austrália , China
10.
J Occup Environ Hyg ; 21(4): 270-286, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38451632

RESUMO

Three-dimensional (3D) printing is an emerging and booming industry in Taiwan. Compared to traditional manufacturing, 3D printing has various advantages, such as advanced customization, additive manufacturing, reduced mold opening time, and reduced consumption of precursors. In this study, the real-time monitoring of particulate matter (PM) and total volatile organic compound (TVOC) emissions from various filaments is investigated using fused deposition modeling with material extrusion technology, a liquid-crystal display, a stereolithography apparatus based on vat photopolymerization technology, and binder jetting for occupational settings. An exposure assessment for nearby workers using the 3D printing process was performed, and improvement measures were recommended. Nine 3D printing fields were measured. The generation rate of ultrafine particles ranged from 1.19 × 1010 to 4.90 × 1012 #/min, and the geometric mean particle size ranged from 30.91 to 55.50 nm. The average concentration of ultrafine particles ranged from 2.31 × 103 to 7.36 × 104 #/cm3, and the PM2.5 and PM10 concentrations in each field ranged from 0.74 ± 0.27 to 12.46 ± 5.61 µg/m3 and from 2.39 ± 0.60 to 30.65 ± 21.26 µg/m3, respectively. The TVOC concentration ranged from 0.127 ± 0.012 to 1.567 ± 0.172 ppm. The respiratory deposition (RDUFPs) dose ranged from 2.02 × 1013 to 5.54 × 1014 nm2/day. Depending on the operating conditions, appropriate control and protective measures should be employed to protect workers' health.


Assuntos
Poluição do Ar em Ambientes Fechados , Compostos Orgânicos Voláteis , Humanos , Taiwan , Poluição do Ar em Ambientes Fechados/análise , Material Particulado/análise , Impressão Tridimensional , Compostos Orgânicos Voláteis/análise , Local de Trabalho
11.
Environ Sci Pollut Res Int ; 31(17): 25033-25045, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38466382

RESUMO

Polybrominated diphenyl ethers (PBDEs) are a group of compounds that, due to their applications, are considered mainly indoor contaminants. To obtain the first information about the presence of PBDEs in Serbia, dust samples (n = 50) were collected in settlements in the northern Serbian province of Vojvodina. The selected/target congeners (BDE-28, 47, 99, 100, 153, 154, and 183) were extracted from house dust by microwave-assisted extraction technique, and purified extracts were analyzed on a dual-column gas chromatograph with micro-electron capture detectors. A wide range of ΣPBDEs was detected (0.295 to 394 ng g-1 dust), which reflects large differences in contamination among the examined homes. For the majority of samples (72%), ΣPBDEs were lower than 5 ng g-1 indicating that people living in Vojvodina province are exposed to low concentrations of PBDEs present in their households. Based on principal component analysis (PCA), balcony areas and age of the house positively correlate with the PBDE congeners with higher detection frequencies (≥ 50%), namely, with BDE-99, BDE-153, and BDE-183. Statistically significant positive correlation (p < 0.01) was obtained for BDE-99 and the number of household's members. Estimated daily intakes (EDItot) were calculated for ingestion and dermal absorption of dust for two age groups-adults and toddlers. These are the first data on PBDE status in the area of the Western Balkan, and the health risk assessment indicates that PBDE levels obtained in household dust do not pose a risk for human health.


Assuntos
Poluição do Ar em Ambientes Fechados , Éteres Difenil Halogenados , Adulto , Humanos , Éteres Difenil Halogenados/análise , Sérvia , Poeira/análise , Poluição do Ar em Ambientes Fechados/análise , Cromatografia Gasosa , Medição de Risco , Exposição Ambiental/análise , Monitoramento Ambiental
13.
Environ Int ; 185: 108549, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38447453

RESUMO

Universal access to clean fuels in household use is one explicit indicator of sustainable development while currently still billions of people rely on solid fuels for daily cooking. Despite of the recognized clean transition trend in general, disparities in household energy mix in different activities (e.g. cooking and heating) and historical trends remain to be elucidated. In this study, we revealed the historical changing trend of the disparity in household cooking and heating activities and associated carbon emissions in rural China. The study found that the poor had higher total direct energy consumption but used less modern energy, especially in cooking activities, in which the poor consumed 60 % more energy than the rich. The disparity in modern household energy use decreased over time, but conversely the disparity in total residential energy consumption increased due to the different energy elasticities as income increases. Though per-capita household CO2 and Black Carbon (BC) emissions were decreasing under switching to modern energies, the disparity in household CO2 and BC deepened over time, and the low-income groups emitted âˆ¼ 10 kg CO2 more compared to the high-income population. Relying solely on spontaneous clean cooking transition had limited impacts in reducing disparities in household energy and carbon emissions, whereas improving access to modern energy had substantial potential to reduce energy consumption and carbon emissions and its disparity. Differentiated energy-related policies to promote high-efficiency modern heating energies affordable for the low-income population should be developed to reduce the disparity, and consequently benefit human health and climate change equally.


Assuntos
Poluição do Ar em Ambientes Fechados , Carbono , Humanos , Dióxido de Carbono , Características da Família , Fatores Socioeconômicos , China , População Rural , Culinária , Poluição do Ar em Ambientes Fechados/análise
14.
Environ Int ; 185: 108539, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38460243

RESUMO

Exposure scenario and receptor behavior significantly affect PM2.5 exposure quantity of persons and resident groups, which in turn influenced indoor or outdoor air quality & health management. An Internet of Things (IoT) system, EnvironMax+, was developed to accurately and conveniently assess residential dynamic PM2.5 exposure state. A university community "QC", as the application area, was divided into four exposure scenarios and five groups of residents. Low-cost mobile sensors and indoor/outdoor pollution migration (IOP) models jointly estimated multi-scenario real-time PM2.5 concentrations. Questionnaire was used to investigate residents' indoor activity characteristics. Mobile application (app) "Air health management (AHM)" could automatic collect residents' activity trajectory. At last, multi-scenario daily exposure concentrations of each residents-group were obtained. The results showed that residential exposure scenario was the most important one, where residents spend about 60 % of their daily time. Closing window was the most significant behavior affecting indoor contamination. The annual average PM2.5 concentration in the studied scenarios: residential scenario (RS) < public scenario (PS) < outdoor scenario (OS) < catering scenario (CS). Except for CS, the outdoor PM2.5 in other scenarios was higher than indoor by 5-10 µg/m3. The multi-scenario population weighted annual average exposure concentration was 37.1 µg/m3, which was 78 % of the annual average outdoor concentration. The exposure concentration of 5 groups: cooks > outdoor workers > indoor workers > students > the elderly, related to their daily activity time proportion in different exposure scenario.


Assuntos
Poluentes Atmosféricos , Poluição do Ar em Ambientes Fechados , Humanos , Idoso , Poluição do Ar em Ambientes Fechados/análise , Poluentes Atmosféricos/análise , Material Particulado/análise , Monitoramento Ambiental/métodos , Universidades , Tamanho da Partícula
15.
Sci Total Environ ; 923: 171496, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38453083

RESUMO

Phenylmethylsiloxanes, as modified products of dimethylsiloxanes, have been used in personal care products (PCPs) and household appliances, with indoor dust serving as one potential reservoir due to their particle-binding properties. This study measured six isomers of two phenylmethylsiloxanes (P3 and P4) in PCPs (99 %) intakes of phenylmethylsiloxanes for adults, while dust ingestion/adsorption (0.19 ng/d) may play important roles for toddlers/infants with little usage of phenylmethylsiloxanes-containing PCPs. Additionally, total daily intakes of PhMeSi(OH)2 (0.30-0.84 ng/d) via ingestion and dermal absorption of dust were higher than P3 (0.06-0.31 ng/d) and P4 (0.02-0.09 ng/d), suggesting exposure risk of degradation product of phenylmethylsiloxanes deserving attention.


Assuntos
Poluição do Ar em Ambientes Fechados , Adulto , Lactente , Humanos , Disponibilidade Biológica , Poluição do Ar em Ambientes Fechados/análise , Poeira/análise , China , Solo , Exposição Ambiental/análise
16.
Sci Rep ; 14(1): 2708, 2024 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-38302627

RESUMO

Infections, such as mucormycosis, often result from inhaling sporangiospore present in the environment. Surprisingly, the extent of airborne Mucormycetes sporangiospore concentrations remains inadequately explored. This study aimed to assess the influence of UV radiation on microbial populations and Mucormycetes spore levels within a hospital environment in northern Iran. A comprehensive dataset comprising 298 air samples collected from both indoor and outdoor settings was compiled. The culture was conducted using Blood Agar and Dichloran Rose Bengal Chloramphenicol (DRBC) culture media, with Chloramphenicol included for fungal agents and Blood Agar for bacterial. Before UV treatment, the average count of Mucormycetes ranged from 0 to 26.4 ± 25.28 CFU m-3, fungal agents from 2.24 ± 3.22 to 117.24 ± 27.6 CFU m-3, and bacterial agents from 29.03 ± 9.9 to 359.37 ± 68.50 CFU m-3. Following UV irradiation, the averages were as follows: Mucormycetes ranged from 0 to 7.85 ± 6.8 CFU m-3, fungal agents from 16.58 ± 4.79 to 154.98 ± 28.35 CFU m-3, and bacterial agents from 0.38 ± 0.65 to 43.92 ± 6.50 CFU m-3. This study, notably marks the pioneering use of UV light to mitigate Mucormycetes spore counts and bacterial agents in northeastern Iran, contributing to the advancement of environmental health and safety practices in hospital settings.


Assuntos
Poluição do Ar em Ambientes Fechados , Fungos , Raios Ultravioleta , Ágar , Esporos Fúngicos , Bactérias , Meios de Cultura , Hospitais , Cloranfenicol , Microbiologia do Ar , Poluição do Ar em Ambientes Fechados/análise , Contagem de Colônia Microbiana
17.
BMC Public Health ; 24(1): 512, 2024 Feb 19.
Artigo em Inglês | MEDLINE | ID: mdl-38369457

RESUMO

BACKGROUND: In low- and middle-income countries, households mainly use solid fuels like wood, charcoal, dung, agricultural residues, and coal for cooking. This poses significant public health concerns due to the emission of harmful particles and gases. To address these issues and support Sustainable Development Goals (SDGs), adopting cleaner cooking fuels like electricity and gas are acknowledged as a viable solution. However, access to these cleaner fuels is limited, especially in rural areas. METHODS: This study conducted a face-to-face survey with 1240 individuals in rural Bangladesh to explore the link between health issues and cooking fuel type, as well as barriers to transitioning to clean cooking. Using a convenient sampling technique across four divisions/regions, the survey gathered socio-demographic and health data, along with information on clean cooking barriers through a semi-structured questionnaire. Binary and multivariable logistic regression analyses were then employed to identify significant associations between cooking fuel type and health problems. RESULTS: The study revealed that a majority of participants (73.3%) relied on solid fuel for cooking. The use of solid fuel was significantly correlated with factors such as lower education levels, reduced family income, location of residence, and the experience of health issues such as cough, chest pressure while breathing, eye discomfort, diabetes, asthma, and allergies. Economic challenges emerged as the foremost obstacle to the adoption of clean cooking, accompanied by other contributing factors. CONCLUSION: The use of solid fuel in rural Bangladeshi households poses substantial health risks, correlating with respiratory, eye, cardiovascular, and metabolic issues. Lower education and income levels, along with specific residential locations, were associated with higher solid fuel usage. Economic challenges emerged as the primary obstacle to adopting clean cooking practices. These findings emphasize the need for implementing strategies to promote clean cooking, address barriers, and contribute to achieving Sustainable Development Goal targets for health and sustainable energy access in Bangladesh.


Assuntos
Poluição do Ar em Ambientes Fechados , Humanos , Bangladesh , Poluição do Ar em Ambientes Fechados/análise , Características da Família , Carvão Mineral , Culinária/métodos , Gases/análise
18.
Sci Total Environ ; 918: 170734, 2024 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-38325455

RESUMO

Daycare centers (DCCs) play an instrumental role in early childhood development, making them a significant indoor environment for a large number of children globally. Amidst routine DCC activities, young children are exposed to a myriad of volatile organic compounds (VOCs), potentially impacting their health. Therefore, this study aims to investigate the VOC emissions during typical DCCs activities and evaluate respective health risk assessments. Employing a full-scale experimental setup within a well-controlled climate chamber, research was conducted into VOC emissions during three typical DCC events: arts-and-crafts (painting, gluing, modeling), cleaning, and sleeping activities tied to mattresses. The research identified 96 distinct VOCs, grouped into twelve categories, from 20 different events examined. Each event exhibited a unique VOC fingerprint, pinpointing potential source tracers. Also, significant variations in VOC emissions from different events were demonstrated. For instance, under cool & dry conditions, acrylic painting recorded high total VOC concentrations of 808 µg/m3, whereas poster painting showed only 58 µg/m3. Given these disparities, the study emphasizes the critical need for carefully selecting arts-and-crafts materials and cleaning agents in DCCs to effectively reduce VOC exposure. It suggests ventilating new mattresses before use and regular mattress check-ups to mitigate VOCs exposure during naps. Importantly, it revealed that certain events resulted in VOC levels exceeding the 10-5 cancer risk thresholds for younger children. Specifically, tetrachloroethylene and styrene from used mattresses in cool & dry conditions, ethylene oxide from new mattresses in warm & humid conditions, and styrene, during sand modeling in both conditions, were the key compounds contributing to this risk. These findings highlight the critical need for age-specific health risk assessments in DCCs. This study highlights the significance of understanding the profiles of VOC emissions from indoor events in DCCs, emphasizing potential health implications and laying a solid foundation for future investigations in this field.


Assuntos
Poluentes Atmosféricos , Poluição do Ar em Ambientes Fechados , Compostos Orgânicos Voláteis , Pré-Escolar , Criança , Humanos , Compostos Orgânicos Voláteis/análise , Medição de Risco , Clima , Estirenos , Poluição do Ar em Ambientes Fechados/análise , Poluentes Atmosféricos/análise , Monitoramento Ambiental
19.
Environ Pollut ; 345: 123475, 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38331241

RESUMO

Indoor dust can contribute substantially to human exposure to known and contaminants of emerging concern (CECs). Novel compounds with high structural variability and different homologues are frequently discovered through screening of the indoor environment, implying that constant monitoring is required. The present study aimed at the identification and semi-quantification of CECs in 46 indoor dust samples collected in Belgium by liquid chromatography high-resolution mass spectrometry. Samples were analyzed applying a targeted and suspect screening approach; the latter based on a suspect list containing >4000 CECs. This allowed the detection of a total of 55 CECs, 34 and 21 of which were identified with confidence level (CL) 1/2 or CL 3, respectively. Besides numerous known contaminants such as di(2-ethylhexyl) phthalate (DEHP), di(2-ethylhexyl) adipate (DEHA) or tris(2-butoxyethyl) phosphate (TBOEP) which were reported with detection frequencies (DFs) > 90%, several novel CECs were annotated. These included phthalates with differing side chains, such as decyl nonyl and decyl undecyl phthalate detected with DFs >80% and identified through the observation of characteristic neutral losses. Additionally, two novel organophosphate flame retardants not previously described in indoor dust, i.e. didecyl butoxyethoxyethyl phosphate (DDeBEEP) and bis(butoxyethyl) butyl phosphate (BBEBP), were identified. The implementation of a dedicated workflow provided semi-quantitative concentrations for a set of suspects. Such data obtained for novel phthalates were in the same order of magnitude as the concentrations observed for legacy phthalates indicating their high relevance for human exposure. From the semi-quantitative data, estimated daily intakes and resulting hazard quotients (HQs) were calculated to estimate the exposure and potential health effects. Neither of the obtained HQ values exceeded the risk threshold, indicating no expected adverse health effects.


Assuntos
Poluição do Ar em Ambientes Fechados , Retardadores de Chama , Ácidos Ftálicos , Humanos , Monitoramento Ambiental/métodos , Poluição do Ar em Ambientes Fechados/análise , Poeira/análise , Ácidos Ftálicos/análise , Organofosfatos/análise , Espectrometria de Massas , Fosfatos/análise , Medição de Risco , Retardadores de Chama/análise , Exposição Ambiental/análise
20.
PLoS One ; 19(2): e0299072, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38412163

RESUMO

This study uses CR-39 radon detectors to examine radon distributions, seasonal indoor radon variations, correction factors, and the influence of building materials and characteristics on indoor radon concentration in 120 dwellings. The study also determines the spatial distribution of radon levels using the ArcGIS geostatistical method. Radon detectors were exposed in bedrooms from April to July (RS), August to November (DS); December to March (HS), and January-December (YS) from 2021 to 2022. The result for the radon levels during the weather seasons were; 32.3 to 190.1 Bqm-3 (80.9 ± 3.2 Bq/m3) for (RS), 30.8 to 151.4 Bqm-3 (68.5 ± 2.7 Bqm-3) for HS and 24.8 to 112.9 Bqm-3(61.7 ± 2.1 Bqm-3) for DS, and 25.2 to 145.2 Bq/m3 (69.4 ± 2.7 Bqm-3). The arithmetic mean for April to July season was greater than August to November. The correction factors associated with this study ranged from 0.9 to 1.2. The annual effective dose (AE) associated with radon data was varied from 0.6 to 4.04 mSv/y (1.8 ± 0.1 mSv/y). The April to July period which was characterized by rains recorded the highest correlation coefficient and indoor radon concentration. Distribution and radon mapping revealed radon that the exposure to the occupant is non-uniformly spread across the studied dwellings. 15.4% of the studied data exceeded WHO reference values of 100 Bq/m3. The seasonal variation, dwelling age, and building materials were observed to have a substantial impact on the levels of radon concentration within the buildings.


Assuntos
Poluentes Radioativos do Ar , Poluição do Ar em Ambientes Fechados , Monitoramento de Radiação , Radônio , Radônio/análise , Estações do Ano , Poluição do Ar em Ambientes Fechados/análise , Gana , Tempo (Meteorologia) , Habitação , Monitoramento de Radiação/métodos , Poluentes Radioativos do Ar/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA