Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 20
Filter
1.
Anal Chem ; 92(17): 11994-12001, 2020 09 01.
Article in English | MEDLINE | ID: mdl-32867489

ABSTRACT

Most studies of ultrasensitive diagnosis of biomolecules from liquid specimens are limited by problems during sample preparation steps, including enrichment and isolation of biomolecules. Here we report a novel platform combining bis(sulfosuccinimidyl)suberate (BS3) and helix-shaped microchannels (BSH) to change the sample preparation paradigm. This BSH system is composed of BS3 for pathogen enrichment and nucleic acid isolation by electrostatic and covalent interaction, and helix-shaped microchannels to minimize sample loss and remove bubbles in large liquid specimens without pH change. The system detected Mycobacterium tuberculosis following enrichment and isolation of 10 mL of liquefied sputum from 11 patients with tuberculosis. Moreover, the system identified KRAS mutations following cell-free DNA isolation of blood plasma from 10 patients with colorectal cancer. This system allows ultrasensitive diagnosis in various disease applications with large volumes of liquid samples.


Subject(s)
Liquid Biopsy/methods , Succinimides/metabolism , Humans
2.
J Clin Microbiol ; 57(5)2019 05.
Article in English | MEDLINE | ID: mdl-30814264

ABSTRACT

We evaluated the diagnostic performance of a simple and label-free pathogen enrichment method using homobifunctional imidoesters (HI) and a microfluidic system, called the SLIM assay, followed by real-time PCR from cerebrospinal fluid (CSF) in human immunodeficiency virus (HIV)-uninfected patients with suspected tuberculous meningitis (TBM). Patients with suspected TBM were prospectively enrolled in a tertiary hospital in an intermediate tuberculosis (TB)-burden country during a 30-month period. TBM was classified according to the uniform case definition. Definite and probable TBM were regarded as the reference standards for TBM, and possible TBM and not-TBM as the reference standards for not-TBM. Of 72 HIV-uninfected patients with suspected TBM, 10 were diagnosed with definite (n = 2) and probable (n = 8) TBM by the uniform case definition. The sensitivity of the SLIM assay was 100% (95% confidence interval [CI], 69 to 100%) compared with definite or probable TBM, and it was superior to those of mycobacterial culture (20% [95% CI, 3 to 56%]) and the Xpert MTB/RIF assay (0% [95% CI, 0 to 31%]). Of 21 possible TBM and 41 not-TBM patients by the uniform case definition, 5 possible TBM and no not-TBM patients gave positive results in the SLIM assay. The specificity of the SLIM assay was 92% (95% CI, 82 to 97%; 5/62). We demonstrated that the SLIM assay had a very high sensitivity and specificity with small samples of 10 cases of definite or probable TBM. Further studies are needed to confirm this finding and to compare the SLIM assay with mycobacterial culture, Xpert MTB/RIF, and Xpert MTB/RIF Ultra assays in a larger prospective cohort of patients with suspected TBM, including both HIV-infected and HIV-uninfected cases.


Subject(s)
Microfluidics/methods , Tuberculosis, Meningeal/diagnosis , Adult , Aged , DNA, Bacterial/genetics , Female , HIV Infections , Humans , Imidoesters , Male , Middle Aged , Molecular Diagnostic Techniques , Mycobacterium tuberculosis , Prospective Studies , Sensitivity and Specificity , Tertiary Care Centers , Tuberculosis, Meningeal/cerebrospinal fluid
3.
Anal Chem ; 90(8): 5108-5115, 2018 04 17.
Article in English | MEDLINE | ID: mdl-29561136

ABSTRACT

Nucleic acid-based diagnostics are widely used for clinical applications due to their powerful recognition of biomolecule properties. Isolation and purification of nucleic acids such as DNA and RNA in the diagnostic system have been severely hampered in point-of-care testing because of low recovery yields, degradation of nucleic acids due to the use of chaotropic detergent and high temperature, and the requirement of large instruments such as centrifuges and thermal controllers. Here, we report a novel large instrument- and detergent-free assay via binary nanomaterial for ultrasensitive nucleic acid isolation and detection from cells (eukaryotic and prokaryotic). This binary nanomaterial couples a zinc oxide nanomultigonal shuttle (ZnO NMS) for cell membrane rupture without detergent and temperature control and diatomaceous earth with dimethyl suberimidate complex (DDS) for the capture and isolation of nucleic acids (NA) from cells. The ZnO NMS was synthesized to a size of 500 nm to permit efficient cell lysis at room temperature within 2 min using the biological, chemical, and physical properties of the nanomaterial. By combining the ZnO NMS with the DDS and proteinase K, the nucleic acid extraction could be completed in 15 min with high quantity and quality. For bacterial cells, DNA isolation with the binary nanomaterial yielded 100 times more DNA, than a commercial spin column based reference kit, as determined by the NanoDrop spectrophotometer. We believe that this binary nanomaterial will be a useful tool for rapid and sensitive nucleic acid isolation and detection without large instruments and detergent in the field of molecular diagnostics.


Subject(s)
Nanostructures/chemistry , Nucleic Acids/analysis , Polymerase Chain Reaction/methods , Bacteria/genetics , DNA, Bacterial/analysis , DNA, Bacterial/isolation & purification , Detergents/chemistry , Dimethyl Suberimidate/chemistry , Endopeptidase K/metabolism , HCT116 Cells , Humans , Nucleic Acids/isolation & purification , Particle Size , Point-of-Care Testing , Temperature , Zinc Oxide/chemistry
4.
Clin Chem ; 64(3): 556-565, 2018 03.
Article in English | MEDLINE | ID: mdl-29208659

ABSTRACT

BACKGROUND: Scrub typhus and severe fever with thrombocytopenia syndrome (SFTS) are the most common tick-borne illnesses in South Korea. Early differentiation of SFTS from scrub typhus in emergency departments is essential but difficult because of their overlapping epidemiology, shared risk factors, and similar clinical manifestations. METHODS: We compared the diagnostic performance of one-step isothermal nucleic acid amplification with bio-optical sensor detection (iNAD) under isothermal conditions, which is rapid (20-30 min), with that of real-time PCR, in patients with a confirmed tick-borne illness. Fifteen patients with confirmed SFTS who provided a total of 15 initial blood samples and 5 follow-up blood samples, and 21 patients with confirmed scrub typhus, were evaluated. RESULTS: The clinical sensitivity of iNAD (100%; 95% CI, 83-100) for SFTS was significantly higher than that of real-time PCR (75%; 95% CI, 51-91; P = 0.047), while its clinical specificity (86%; 95% CI, 65-97) was similar to that of real-time PCR (95%; 95% CI, 77-99; P = 0.61). The clinical sensitivity of iNAD for scrub typhus (100%; 95% CI, 81-100) was significantly higher than that of real-time PCR for scrub typhus (67%; 95% CI, 43-85; P = 0.009), while its clinical specificity (90%; 95% CI, 67-98) was similar to that of real-time PCR (95%; 95% CI, 73-100; P > 0.99). CONCLUSIONS: iNAD is a valuable, rapid method of detecting SFTS virus and Orientia tsutsugamushi with high clinical sensitivity and specificity.


Subject(s)
Nucleic Acid Amplification Techniques/methods , Phlebotomus Fever/diagnosis , Scrub Typhus/diagnosis , Tick-Borne Diseases/diagnosis , Aged , Aged, 80 and over , Humans , Middle Aged , Optics and Photonics/instrumentation , Optics and Photonics/methods , Real-Time Polymerase Chain Reaction , Republic of Korea , Retrospective Studies , Sensitivity and Specificity
5.
Anal Biochem ; 544: 87-92, 2018 03 01.
Article in English | MEDLINE | ID: mdl-29289485

ABSTRACT

Rapid and sensitive detection of low amounts of pathogen in large samples is needed for early diagnosis and treatment of patients and surveillance of pathogen. In this study, we report a microfluidic platform for detection of low pathogen levels in a large sample volume that couples an Magainin 1 based microfluidic platform for pathogen enrichment and a recombinase polymerase amplification (RPA) sensor for simultaneous pathogenic DNA amplification and detection in a label-free and real-time manner. Magainin 1 is used as a pathogen enrichment agent with a herringbone microfluidic chip. Using this enrichment platform, the detection limit was found to be 20 times more sensitive in 10 ml urine with Salmonella and 10 times more sensitive in 10 ml urine with Brucella than that of real-time PCR without the enrichment process. Furthermore, the combination system of the enrichment platform and an RPA sensor that based on an isothermal DNA amplification method with rapidity and sensitivity for detection can detect a pathogen at down to 50 CFU in 10 ml urine for Salmonella and 102 CFU in 10 ml urine for Brucella within 60 min. This system will be useful as it has the potential for better diagnosis of pathogens by increasing the capture efficiency of the pathogen in large samples, subsequently enhancing the detection limit of pathogenic DNA.


Subject(s)
Communicable Diseases/diagnosis , DNA, Bacterial/genetics , Microfluidic Analytical Techniques , Nucleic Acid Amplification Techniques , Real-Time Polymerase Chain Reaction , Communicable Diseases/genetics
6.
Sens Actuators B Chem ; 273: 316-321, 2018 Nov 10.
Article in English | MEDLINE | ID: mdl-32288252

ABSTRACT

Rapid and highly sensitive detection of biomolecules is greatly needed for pathogen diagnosis in clinical samples, but the method needs to be significantly improved in terms of sensitivity and specificity for actual use in clinical settings. Here, we report the development of an improved molecular diagnostics tool that utilizes CRISPR/dCas9-mediated biosensor that couples a nuclease inactivated Cas9 (dCas9) and single microring resonator biosensor, enables label-free and real-time detection of pathogenic DNA and RNA. We addressed the clinical utility of this CRISPR/dCas9-mediated biosensor in tick-borne illnesses including scrub typhus (ST) and severe fever with thrombocytopenia syndrome (SFTS), whose clinical presentations are too similar to be easily differentiated. By using CRISPR/dCas9-mediated biosensor, we achieved single molecule sensitivity for the detection of ST (0.54 aM) and SFTS (0.63 aM); this detection sensitivity is 100 times more sensitive than that of RT-PCR assay. Finally, CRISPR/dCas9-mediated biosensor was able to clearly distinguish between ST and SFTS in serum samples within 20 min. We believe that CRISPR/dCas9-mediated biosensor will be useful for rapid and accurate molecular diagnostic tool that is suitable for immediate clinical applications.

7.
Anal Chem ; 89(14): 7502-7510, 2017 07 18.
Article in English | MEDLINE | ID: mdl-28633525

ABSTRACT

The isolation of nucleic acids in the lab on a chip is crucial to achieve the maximal effectiveness of point-of-care testing for detection in clinical applications. Here, we report on the use of a simple and versatile single-channel microfluidic platform that combines dimethyl pimelimidate (DMP) for nucleic acids (both RNA and DNA) extraction without electricity using a thin-film system. The system is based on the adaption of DMP into nonchaotropic-based nucleic acids and the capture of reagents into a low-cost thin-film platform for use as a microfluidic total analysis system, which can be utilized for sample processing in clinical diagnostics. Moreover, we assessed the use of the DMP system for the extraction of nucleic acids from various samples, including mammalian cells, bacterial cells, and viruses from human disease, and we also confirmed that the quality and quantity of the nucleic acids extracted were sufficient to allow for the robust detection of biomarkers and/or pathogens in downstream analysis. Furthermore, this DMP system does not require any instruments and electricity, and has improved time efficiency, portability, and affordability. Thus, we believe that the DMP system may change the paradigm of sample processing in clinical diagnostics.

9.
Inquiry ; 58: 469580211065684, 2021.
Article in English | MEDLINE | ID: mdl-34930054

ABSTRACT

BACKGROUND: Sexually transmitted diseases (STDs) are common infectious diseases in humans transmitted through unprotected sexual activities. In South Korea, despite the high annual incidence of STDs, detailed examinations of pathogen-specific factors and causes for delays in diagnosis and treatment are still lacking. Furthermore, STD prevalence patterns and important pathogen-specific factors remain unclear. Herein, we retrospectively analyzed the epidemiology of STDs in South Korea in 2019 by analyzing the association of pathogen-specific infection patterns with factors such as sex, age, region, and month. METHODS: We obtained the STD test results of 172,973 individuals from the Seoul Clinic Laboratory in 2019, most of whom had multiple infections; hence, 275,296 STD-positive cases were included in this analysis. Through deoxyribonucleic acid (DNA) amplification, they were categorized by pathogen type. Subsequently, they were further classified by month, region, and age while concurrently being stratified according to sex. RESULTS: Among the 12 pathogens detected in this study, Gardnerella vaginalis had the highest prevalence, with 92,490 cases in both sex groups; moreover, many of them were concurrently infected by two or more pathogens. The prevalence of STDs did not differ according to month or region. Conversely, the pathogen-specific prevalence rates significantly differed according to age. Older adults had higher prevalence rates of Chlamydia trachomatis, Trichomonas vaginalis, Candida albicans, and herpes simplex virus type 1 infections than younger adults. CONCLUSION: These pathogen-specific prevalence patterns provide information that helps to understand population vulnerability according to region and age and helps develop STD prevention and treatment strategies in South Korea.


Subject(s)
Sexually Transmitted Diseases , Aged , Humans , Incidence , Prevalence , Republic of Korea/epidemiology , Retrospective Studies , Sexually Transmitted Diseases/epidemiology
10.
Micromachines (Basel) ; 10(7)2019 Jun 27.
Article in English | MEDLINE | ID: mdl-31252533

ABSTRACT

Blood plasma from patients is a powerful resource for diagnosing infectious disease due to it having many genetic materials as well as being relatively easy to obtain. Thus, various biosensors have been investigated for diagnosing diseases in blood plasma. However, there are no optimized and validated sensors for clinical use due to the low sensitivity, complexity, and difficulties of removing the inhibitors from plasma samples. In this study, we described a silicon microring resonator sensor used to detect Coxiella burnetii from the blood plasma of Q-fever patients in a label-free, real-time manner. Q-fever is an infectious disease caused by Coxiella burnetii via direct contact or inhalation aerosols. We validated this biosensor in the blood plasma of 35 clinical samples (including 16 Q fever samples infected with Coxiella burnetii and 19 samples infected with other febrile diseases. The biosensors are capable of rapid (10 min), highly sensitive (87.5%), and specific (89.5%) detection in plasma samples compared to the use of the conventional method.

11.
Medicine (Baltimore) ; 98(23): e15724, 2019 Jun.
Article in English | MEDLINE | ID: mdl-31169672

ABSTRACT

Diagnosis of Q fever is difficult due to the lack of distinct clinical features that distinguish it from other febrile diseases. Serologic testing is the gold standard method for diagnosing Q fever, but antibody formation may not be detectable for 2 to 3 weeks from symptom onset, limiting early diagnosis. We thus evaluated the diagnostic utility of polymerase chain reaction (PCR) to detect Coxellia burnetii DNA in serum from patients with suspected acute Q fever.All adult patients with suspected acute Q fever were prospectively enrolled at a tertiary-care hospital from January 2016 through July 2018. Acute Q fever was diagnosed using clinical and laboratory criteria: fever with at least one other symptoms (myalgia, headache, pneumonia, or hepatitis) and single phase II immunoglobulin G (IgG) antibody titers ≥1:200 or immunoglobulin M (IgM) antibody titer ≥1:50 (probable), or a fourfold increase or seroconversion in phase II IgG antibody titers as measured by indirect immunofluorescence assays between paired samples (confirmed). We performed PCR targeting the transposase gene insertion element IS1111a of C. burnetii.Of the 35 patients with suspected acute Q fever, 16 (46%) were diagnosed with acute Q fever including 8 probable and 8 confirmed cases; the remaining 19 (54%) were diagnosed with other febrile diseases. The proportion of males diagnosed with Q fever was higher than those diagnosed with other febrile diseases (88% vs 44%, P = .03), but there were no other significant differences in clinical characteristics between the 2 groups. The Q fever PCR sensitivity was 81% (95% confidence interval [CI], 54-96), specificity was 90% (95% CI, 67-99), positive predictive value was 87% (95% CI, 63-96), and negative predictive value was 85% (95% CI, 67-94).Q fever PCR testing using blood from patients with suspected acute Q fever seems to be a rapid and useful test for early diagnosis of Q fever.


Subject(s)
Coxiella burnetii/genetics , DNA, Bacterial/blood , Polymerase Chain Reaction/statistics & numerical data , Q Fever/diagnosis , Acute Disease , Adult , Antibodies, Bacterial/blood , Coxiella burnetii/immunology , Female , Fluorescent Antibody Technique, Indirect , Humans , Immunoglobulin G/immunology , Immunoglobulin M/immunology , Male , Middle Aged , Predictive Value of Tests , Prospective Studies , Republic of Korea , Sensitivity and Specificity
12.
Lab Chip ; 19(13): 2256-2264, 2019 06 25.
Article in English | MEDLINE | ID: mdl-31173022

ABSTRACT

The isolation of bio-molecules such as proteins and nucleic acids is a necessary step for both diagnostic and analytical processes in the broad fields of research and clinical applications. Although a myriad of isolation technologies have been developed, a method for simultaneous protein and nucleic acid isolation has not been explored for clinical use. Obtaining samples from certain cancers or rare diseases can be difficult. In addition, the heterogeneity of cancer tissues typically leads to inconsistent results when analyzing biomolecules. We here describe a homobifunctional imidoester (HI)-based microfluidic system for simultaneous DNA and protein isolation from either a solid or liquid single biopsy sample. An efficient and cost effective microfluidic design with less air bubbles was identified among several candidates using simulation and experimental results from the streamlining of isolation processing. HI groups were used as capture reagents for the simultaneous isolation of bio-molecules from a single specimen in a single microfluidic system. The clinical utility of this system for the simultaneous isolation of DNA and proteins within 40 min was validated in cancer cell lines and 23 tissue biopsies from colorectal cancer patients. The quantity of isolated protein and DNA was high using this system compared to the spin-column method. This HI-based microfluidic system shows good rapidity, affordability, and portability in the isolation of bio-molecules from limited samples for subsequent clinical analysis.


Subject(s)
Colorectal Neoplasms/chemistry , DNA/isolation & purification , Microfluidic Analytical Techniques , Proteins/isolation & purification , Colorectal Neoplasms/pathology , DNA/chemistry , Humans , Liquid Biopsy , Microfluidic Analytical Techniques/instrumentation , Proteins/chemistry
13.
Adv Sci (Weinh) ; 5(10): 1800614, 2018 Oct.
Article in English | MEDLINE | ID: mdl-30356899

ABSTRACT

Cell-free nucleic acids (cfNAs) are emerging diagnostic biomarkers for monitoring the treatment and recurrence of cancers. In particular, the biological role and clinical usefulness of cfNAs obtained from the plasma of patients with various cancers are popular and still intensely explored, yet most studies are limited by technical problems during cfNA isolation. A dimethyl dithiobispropionimidate (DTBP)-based microchannel platform that enables spontaneous cfNA capture in 15 min with minimal cellular background and no requirements for use of bulky instruments is reported first. This platform identified KRAS and BRAF hot-spot mutations following cfDNA isolation from the blood plasma and tissues obtained from 30 colorectal cancer patients. The correlation of mutations between the primary tissues and plasma from the patients was high using this platform with whole genome sequencing compared to the spin-column method. This platform can also be combined with various detection approaches (biooptical sensor, Sanger sequencing, and polymerase chain reaction (PCR)) for rapid, simple, low-cost, and sensitive circulating tumor DNA detection in blood plasma. The efficiency and versatility of this platform in isolating cfNAs from liquid biopsies has applications in cancer treatment and precision medicine.

14.
Biosens Bioelectron ; 111: 66-73, 2018 Jul 15.
Article in English | MEDLINE | ID: mdl-29653418

ABSTRACT

Diseases caused by pathogenic microorganisms including bacteria and viruses can cause serious medical issues including death and result in huge economic losses. Despite the myriad of recent advances in the rapid and accurate detection of pathogens, large volume clinical samples with a low concentration of pathogens continue to present challenges for diagnosis and surveillance. We here report a simple and label-free approach via homobifunctional imidoesters (HIs) with a microfluidic platform (SLIM) to efficiently enrich and extract pathogens at low concentrations from clinical samples. The SLIM system consists of an assembled double microfluidic chip for streamlining large volume processing and HIs for capturing pathogens and isolating nucleic acids by both electrostatic and covalent interaction without a chaotropic detergent or bulky instruments. The SLIM system significantly increases the enrichment and extraction rate of pathogens (up to 80% at 10 CFU (colony forming unit) in a 1 mL volume within 50 min). We demonstrated its clinical utility in large sample volumes from 46 clinical specimens including environmental swabs, saliva, and blood plasma. The SLIM system showed higher sensitivity with these samples and could detect pathogens that were below the threshold of detection with other methods. Finally, by combining our SLIM approach with an isothermal optical sensor, pathogens could be detected at a very high sensitivity in blood plasma samples within 80 min via enrichment, extraction and detection steps. Our SLIM system thus provides a simple, reliable, cost-effective and ultrasensitive pathogen diagnosis platform for use with large volume clinical samples and would thus have significant utility for various infectious diseases.


Subject(s)
Biosensing Techniques/instrumentation , Communicable Diseases/microbiology , Communicable Diseases/virology , Imidoesters/chemistry , Lab-On-A-Chip Devices , Communicable Diseases/blood , Communicable Diseases/diagnosis , Equipment Design , Escherichia coli/isolation & purification , Escherichia coli Infections/blood , Escherichia coli Infections/diagnosis , Herpes Zoster/blood , Herpes Zoster/diagnosis , Herpesvirus 3, Human/isolation & purification , Humans , Point-of-Care Systems , Saliva/microbiology , Saliva/virology
15.
Biosens Bioelectron ; 119: 79-85, 2018 Nov 15.
Article in English | MEDLINE | ID: mdl-30103157

ABSTRACT

Rapid identification of emerging infectious pathogens is crucial for preventing public health threats. Various pathogen detection techniques have been introduced; however, most techniques are time-consuming and lack multiple-target detection specificity. Although multiple-target detection techniques can distinguish emerging infectious pathogens from related pathogens, direct amplification methods have not been widely examined. Here, we present a novel arch-shaped multiple-target sensor capable of rapid pathogen identification using direct amplification in clinical samples. In this study, an arch-shaped amplification containing primer sequences was designed to rapidly amplify multiple targets. Further, the sensing platform allowed for sensitive and specific detection of human coronavirus, Middle East respiratory syndrome, Zika virus, and Ebola virus down to several copies. This platform also simultaneously distinguished between Middle East respiratory syndrome and human coronavirus in clinical specimens within 20 min. This arch-shaped multiple-target sensing assay can provide rapid, sensitive, and accurate diagnoses of emerging infectious diseases in clinical applications.


Subject(s)
Biosensing Techniques/methods , Communicable Diseases, Emerging/diagnosis , Communicable Diseases/diagnosis , Communicable Diseases/virology , Communicable Diseases, Emerging/virology , Humans , Nucleic Acid Amplification Techniques , Sensitivity and Specificity , Viruses/genetics
16.
J Biophotonics ; 11(4): e201700167, 2018 04.
Article in English | MEDLINE | ID: mdl-29024445

ABSTRACT

Recent zoonotic outbreaks, such as Zika, Middle East respiratory syndrome and Ebola, have highlighted the need for rapid and accurate diagnostic assays that can be used to aid pathogen control. Q fever is a zoonotic disease caused by the transmission of Coxiella burnetii that can cause serious illness in humans through aerosols and is considered a potential bioterrorism agent. However, the existing assays are not suitable for the detection of this pathogen due to its low levels in real samples. We here describe a rapid bio-optical sensor for the accurate detection of Q fever and validate its clinical utility. By combining a bio-optical sensor, that transduces the presence of the target DNA based on binding-induced changes in the refractive index on the waveguide surface in a label-free and real-time manner, with isothermal DNA amplification, this new diagnostic tool offers a rapid (<20 min), 1-step DNA amplification/detection method. We confirmed the clinical sensitivity (>90%) of the bio-optical sensor by detecting C. burnetii in 11 formalin-fixed, paraffin-embedded liver biopsy samples from acute Q fever hepatitis patients and in 16 blood plasma samples from patients in which Q fever is the cause of fever of unknown origin.


Subject(s)
Biosensing Techniques/instrumentation , Optical Devices , Q Fever/diagnosis , Coxiella burnetii/genetics , Coxiella burnetii/isolation & purification , Coxiella burnetii/physiology , Fever of Unknown Origin/blood , Hepatitis/diagnosis , Humans , Polymerase Chain Reaction , Q Fever/microbiology , Time Factors
17.
Medicine (Baltimore) ; 97(34): e11881, 2018 Aug.
Article in English | MEDLINE | ID: mdl-30142785

ABSTRACT

Coxiella burnetii is a common cause of blood culture-negative infective endocarditis (IE). Molecular detection of C burnetii DNA in clinical specimens is a promising method of diagnosing Q fever endocarditis. Here, we examined the diagnostic utility of Q fever polymerase chain reaction (PCR) of formalin-fixed heart valve tissue from patients with blood culture-negative IE who underwent heart valve surgery. Clinical and laboratory data of patients with blood culture-negative IE who underwent heart valve surgery during a 6-year period and for whom biopsy tissues were available were reviewed retrospectively. Blood culture-positive IE patients who underwent heart valve surgery within the last 3 years were used as controls. Heart valve samples were cultured and also subjected to histological examination and PCR for Q fever, brucellosis, and bartonellosis. Data from 20 patients with blood culture-negative IE and 20 with blood culture-positive IE were analyzed. Eight cases of blood culture-negative IE were PCR-positive for C burnetii (40%; 95% confidence interval, 19-64). No specimen was PCR-positive for brucellosis or bartonellosis. Histologically, 4 of 8 specimens with a positive Q fever PCR result were characterized by clusters of multinucleated giant cells without a fibrin ring. None of 20 patients with blood culture-negative IE received anti-Coxiella antibiotic therapy due to lack of clinical suspicion. Six-month mortality was higher in the Q fever PCR-positive group than in the Q fever PCR-negative group [38% (3/8) vs 0% (0/12), P = .049). Of the 20 patients with blood culture-positive IE, none yielded a positive Q fever PCR result for valve tissue. Approximately 40% of patients with culture-negative IE who received heart valve surgery were PCR-positive for Q fever; patients without clinical suspicion suffered high mortality. These data suggest that Q fever IE in patients with culture-negative IE is often missed in routine clinical practice.


Subject(s)
Coxiella burnetii/genetics , Endocarditis/microbiology , Heart Valves/microbiology , Polymerase Chain Reaction/methods , Q Fever/diagnosis , Adult , Aged , Blood Culture , Cardiac Surgical Procedures/adverse effects , Endocarditis/diagnosis , Endocarditis/etiology , Female , Humans , Male , Middle Aged , Q Fever/complications , Retrospective Studies , Survival Rate
18.
Oncotarget ; 8(48): 83860-83871, 2017 Oct 13.
Article in English | MEDLINE | ID: mdl-29137388

ABSTRACT

Although KRAS mutational status testing is becoming a companion diagnostic tool for managing patients with colorectal cancer (CRC), there are still several difficulties when analyzing KRAS mutations using the existing assays, particularly with regard to low sensitivity, its time-consuming, and the need for large instruments. We developed a rapid, sensitive, and specific mutation detection assay based on the bio-photonic sensor termed ISAD (isothermal solid-phase amplification/detection), and used it to analyze KRAS gene mutations in human clinical samples. To validate the ISAD-KRAS assay for use in clinical diagnostics, we examined for hotspot KRAS mutations (codon 12 and codon 13) in 70 CRC specimens using PCR and direct sequencing methods. In a serial dilution study, ISAD-KRAS could detect mutations in a sample containing only 1% of the mutant allele in a mixture of wild-type DNA, whereas both PCR and direct sequencing methods could detect mutations in a sample containing approximately 30% of mutant cells. The results of the ISAD-KRAS assay from 70 clinical samples matched those from PCR and direct sequencing, except in 5 cases, wherein ISAD-KRAS could detect mutations that were not detected by PCR and direct sequencing. We also found that the sensitivity and specificity of ISAD-KRAS were 100% within 30 min. The ISAD-KRAS assay provides a rapid, highly sensitive, and label-free method for KRAS mutation testing, and can serve as a robust and near patient testing approach for the rapid detection of patients most likely to respond to anti-EGFR drugs.

19.
Biosens Bioelectron ; 90: 187-194, 2017 Apr 15.
Article in English | MEDLINE | ID: mdl-27894035

ABSTRACT

Recently, RNA viral infections caused by respiratory viruses, such as influenza, parainfluenza, respiratory syncytial virus, coronavirus, and Middle East respiratory syndrome-coronavirus (MERS-CoV), and Zika virus, are a major public health threats in the world. Although myriads of diagnostic methods based on RNA amplification have been developed in the last decades, they continue to lack speed, sensitivity, and specificity for clinical use. A rapid and accurate diagnostic method is needed for appropriate control, including isolation and treatment of the patients. Here, we report an isothermal, label-free, one-step RNA amplification and detection system, termed as iROAD, for the diagnosis of respiratory diseases. It couples a one-step isothermal RNA amplification method and a bio-optical sensor for simultaneous viral RNA amplification/detection in a label-free and real-time manner. The iROAD assay offers a one-step viral RNA amplification/detection example to rapid analysis (<20min). The detection limit of iROAD assay was found to be 10-times more sensitive than that of real-time reverse transcription-PCR method. We confirmed the clinical utility of the iROAD assay by detecting viral RNAs obtained from 63 human respiratory samples. We envision that the iROAD assay will be useful and potentially adaptable for better diagnosis of emerging infectious diseases including respiratory diseases.


Subject(s)
Biosensing Techniques/methods , Nucleic Acid Amplification Techniques/methods , RNA, Viral/isolation & purification , Virus Diseases/diagnosis , Coronavirus/genetics , Coronavirus/isolation & purification , Coronavirus Infections/diagnosis , Coronavirus Infections/genetics , Humans , Influenza, Human/diagnosis , Influenza, Human/genetics , Alphainfluenzavirus/genetics , Alphainfluenzavirus/isolation & purification , Betainfluenzavirus/genetics , Betainfluenzavirus/isolation & purification , Limit of Detection , RNA, Viral/genetics , Virus Diseases/genetics
20.
PLoS One ; 12(7): e0180237, 2017.
Article in English | MEDLINE | ID: mdl-28672014

ABSTRACT

BACKGROUND: Serologic diagnosis is one of the most widely used diagnostic methods for Q fever, but the window period in antibody response of 2 to 3 weeks after symptom onset results in significant diagnostic delay. We investigated the diagnostic utility of Q fever PCR from formalin-fixed liver tissues in Q fever patients with acute hepatitis. METHODS: We reviewed the clinical and laboratory data in patients with Q fever hepatitis who underwent liver biopsy during a 17-year period, and whose biopsied tissues were available. We also selected patients who revealed granuloma in liver biopsy and with no Q fever diagnosis within the last 3 years as control. Acute Q fever hepatitis was diagnosed if two or more of the following clinical, serologic, or histopathologic criteria were met: (1) an infectious hepatitis-like clinical feature such as fever (≥ 38°C) with elevated hepatic transaminase levels; (2) exhibition of a phase II immunoglobulin G (IgG) antibodies titer by IFA of ≥ 1:128 in single determination, or a four-fold or greater rise between two separate samples obtained two or more weeks apart; (3) histologic finding of biopsy tissue showing characteristic fibrin ring granuloma. RESULTS: A total of 11 patients with acute Q fever hepatitis were selected and analyzed. Of the 11 patients, 3 (27%) had exposure to zoonotic risk factors and 7 (63%) met the serologic criteria. Granulomas with either circumferential or radiating fibrin deposition were observed in 10 cases on liver biopsy and in 1 case on bone marrow biopsy. 8 (73%) revealed positive Coxiella burnetii PCR from their formalin-fixed liver tissues. In contrast, none of 10 patients with alternative diagnosis who had hepatic granuloma revealed positive C. burnetii PCR from their formalin-fixed liver tissues. CONCLUSIONS: Q fever PCR from formalin-fixed liver tissues appears to be a useful adjunct for diagnosing Q fever hepatitis.


Subject(s)
Coxiella burnetii/isolation & purification , Formaldehyde , Hepatitis/complications , Q Fever/pathology , Tissue Fixation , Acute Disease , Adult , Aged , Coxiella burnetii/genetics , Humans , Male , Middle Aged , Q Fever/complications , Retrospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL