Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters

Database
Language
Journal subject
Affiliation country
Publication year range
1.
J Ophthalmol ; 2024: 2443887, 2024.
Article in English | MEDLINE | ID: mdl-38500553

ABSTRACT

Purpose: The purpose of this study was to investigate the utility of steady state pattern electroretinogram (ss-PERG) in detecting retinal ganglion cell (RGC) dysfunction in glaucoma suspects (GS) who had normal 24-2 Humphrey Visual Fields (HFA). Materials and Methods: This was a prospective cohort study of GS patients who were identified based on optic disc appearance with normal HFAs. Patients received a complete eye examination, standard automated perimetry (SAP), optical coherence tomography (OCT), and ss-PERG measurements. The ss-PERG parameters, Magnitude (Mag), Magnitude D (MagD), and MagD/Mag ratio, were examined, along with their relationships between HFA and OCT measurements. Results: Twenty-five patients were included in this study, with a total of 49 eyes. Fifteen eyes had abnormal ss-PERG parameters and when compared to GS eyes with normal ss-PERG parameters, there were significant differences in HFA 24-2, retinal nerve fiber layer (RNFL) thickness, and ganglion cell layer and inner plexiform layer (GCL + IPL) thickness. All ss-PERG parameters were significantly correlated with 24-2 VF mean deviation (MD) and visual field index (VFI), as well as 10-2 VF MD after controlling for age, sex, intraocular pressure, central corneal thickness, and spherical equivalent. When controlled for age, spherical equivalent, and IOP, MagD/Mag ratio significantly contributed to the variance in average GCL + IPL thicknesses, whereas 24-2 VF MD and 10-2 VF MD did not. MagD/Mag ratio also significantly accounted for variance in all macular GCL + IPL sectors, while 10-2 VF MD did not. Conclusions: ss-PERG has significant correlations with HFA global indices and was predictive of GCL + IPL thickness in GS patients. Clinical Significance. ss-PERG may serve as a useful functional tool for detecting and measuring RGC dysfunction in GS. It appears to be more sensitive than HFA in the detection of early changes in GCL + IPL thicknesses and may be helpful to use in conjunction with current diagnostic studies to improve the ability of monitoring GS progression.

2.
J Glaucoma ; 33(8): 566-575, 2024 Aug 01.
Article in English | MEDLINE | ID: mdl-38709197

ABSTRACT

PRCIS: This systematic review and meta-analysis found that 360-degree selective laser trabeculoplasty (SLT) is significantly more effective than 180-degree SLT at reducing intraocular pressure at 1-month and 1-year follow-ups without increased serious adverse event risk. PURPOSE: To determine the efficacy of 180- versus 360-degree selective laser trabeculoplasty (SLT) in adults with open angle glaucoma (OAG) and ocular hypertension (OHT). METHODS: A systematic review was performed using PubMed, Embase, and Scopus databases, from 1995 to December 30, 2023, for studies comparing 180 and 360-degree SLT in adults with OAG and OHT (PROSPERO ID: CRD42024497832). Meta-analyses were performed to calculate nominal percent and raw reductions in intraocular pressure (IOP) between treatment groups at 1-month, 1-year, and 2-year follow-ups, as well as success rates, defined as a 20% or greater IOP reduction. RESULTS: Nine studies with 1044 eyes were included; 491 received 180-degree SLT, and 553 received 360-degree SLT. At the 1-month follow-up, 360-degree SLT reduced IOP by 3.45% more (WMD=3.45; 95% CI: 2.02-4.88; P <0.00001) and 0.87 mm Hg more (WMD=0.87; 95% CI: 0.35-1.38; P =0.0010). At the 1-year follow-up, 360-degree SLT reduced IOP by 4.33% more (WMD=4.33; 95% CI: 2.35-6.32; P <0.0001) and 1.15 mm Hg more (WMD=1.15; 95% CI: 0.25-2.04; P =0.01). At 2 years of follow-up, 360-degree SLT reduced IOP by 4.86% more (WMD=4.86; 95% CI: -0.32, 10.0; P =0.07) and 1.25 mm Hg more (WMD=1.25; 95% CI: -0.29, 2.79; P =0.11); however, the difference was not statistically significant. Compared with 360-degree SLT, 180-degree SLT had a significantly lower success rate (OR=0.50; 95% CI: 0.35-0.72; P =0.0002). There was no difference in serious complications between interventions. CONCLUSIONS: 360-degree SLT is more effective than 180-degree SLT at lowering IOP at 1-month and 1-year follow-ups as well as achieving successful IOP control without increased risk of serious complications.


Subject(s)
Glaucoma, Open-Angle , Intraocular Pressure , Laser Therapy , Ocular Hypertension , Trabeculectomy , Humans , Trabeculectomy/methods , Glaucoma, Open-Angle/surgery , Glaucoma, Open-Angle/physiopathology , Ocular Hypertension/surgery , Ocular Hypertension/physiopathology , Intraocular Pressure/physiology , Laser Therapy/methods , Tonometry, Ocular , Treatment Outcome
3.
Clin Ophthalmol ; 18: 2205-2215, 2024.
Article in English | MEDLINE | ID: mdl-39131544

ABSTRACT

Purpose: To perform a meta-analysis and systematic review to compare the efficacy and complications of micropulse laser trabeculoplasty (MLT) and selective laser trabeculoplasty (SLT) in adult patients with open-angle glaucoma (OAG) and ocular hypertension (OHT). Methods: We performed a systematic review utilizing PubMed, Embase, and Scopus, on April 8, 2024. Meta-analyses were performed for the mean change in intraocular pressure (IOP) at one-month, six-month, and one-year follow-up visits, rate of IOP spikes (>5 mmHg increase from the pre-procedure baseline IOP), rate of treatment failure (<20% or <3 mmHg reduction in IOP or requiring additional medications or procedures), and mean change in number of medications. Results: Six studies, with a total of 593 eyes, were included: 283 underwent MLT, while 310 underwent SLT. A statistically significant difference in the efficacy of MLT versus SLT at one-month and six-month follow-ups was present, with SLT reducing IOP by 0.83 mmHg (95% CI: 0.20, 1.47; P = 0.01) more and 0.55 mmHg (95% CI: 0.02, 1.08; P = 0.04) more than MLT, respectively. At the one-year follow-up, there was no significant disparity in IOP reduction between SLT and MLT (WMD = 0.16; 95% CI: -0.40, 0.71; P = 0.58). There was a significantly lower rate of IOP spikes in the MLT treatment group (RR = 0.37; 95% CI: 0.16, 0.89; P = 0.03). There was no statistically significant difference in the rate of treatment failures (RR = 1.05; 95% CI: 0.68, 1.62; P = 0.84) or number of topical medications reduced (WMD = 0.06; 95% CI: -0.13, 0.26; P = 0.53). Conclusion: While SLT may offer greater short-term reductions in IOP, it may be associated with more postoperative IOP spikes when compared to MLT. At one-year follow-up, there were no significant differences in IOP reduction or failure rates between the MLT and SLT groups.

4.
J Curr Glaucoma Pract ; 17(4): 178-190, 2023.
Article in English | MEDLINE | ID: mdl-38269268

ABSTRACT

Aim and background: To evaluate the ability of pattern electroretinogram (PERG) to detect improvement of retinal ganglion cell (RGC) function in glaucoma suspects (GS) after medically reducing intraocular pressure (IOP) using prostaglandin analog drops. Materials and methods: Six subjects (eight eyes) received topical IOP lowering treatment based on their clinical examination and were observed at Manhattan Eye, Ear & Throat Hospital over an average of 3.1 ± 2.2 months. During this time, participants underwent a full ophthalmologic exam and were evaluated with a Humphrey visual field analyzer (HFA) 24-2 [24-2 mean deviation (MD), 24-2 pattern standard deviation (PSD), and 24-2 visual field indices (VFI)], Diopsys NOVA PERG optimized for glaucoma [magnitude (Mag), magnitudeD (MagD), and magnitudeD/magnitude ratio (MagD/Mag ratio)] and optical coherence tomography (OCT)-derived average retinal nerve fiber layer thickness (avRNFLT) and average ganglion cell layer + inner plexiform layer (avGCL + IPL) thicknesses at baseline visit (pretreatment) and 3 months later (posttreatment). Goldman applanation tonometry was used to measure IOP at each visit. Paired sample t-tests were conducted to determine the statistical significance of the change in IOP, HFA indices, PERG parameters, and OCT thickness measurements between the two visits. Results: Lowering IOP by 22.29% resulted in a significant increase (32.98 and 15.49%) in MagD [t (7) = -3.174, 95% confidence interval (CI) = -0.53, -0.08, p = 0.016] and MagD/Mag ratio [t (7) = -3.233, 95% CI = -0.20, -0.03, p = 0.014], respectively. There was a positive percentage change for all variables of interest, however, 24-2 MD, Mag, avRNFLT, and GCL+ IPLT did not reach statistical significance. Conclusion: After reducing IOP by 22.29% for a duration of 3.1 months, the PERG parameters, MagD and MagD/Mag ratio, significantly improved by 32.98 and 15.49%, respectively. Clinical significance: Pattern electroretinogram (PERG) may be a crucial tool for clinicians to locate a window of opportunity in which degenerating yet viable RGCs could be rescued from irreversible damage. We suggest consideration of PERG as a tool in early retinal ganglion cell (RGC) dysfunction detection as well as for monitoring IOP lowering treatment. How to cite this article: Tirsi A, Gliagias V, Sheha H, et al. Retinal Ganglion Cell Functional Recovery after Intraocular Pressure Lowering Treatment Using Prostaglandin Analogs in Glaucoma Suspects: A Prospective Pilot Study. J Curr Glaucoma Pract 2023;17(4):178-190.

SELECTION OF CITATIONS
SEARCH DETAIL