Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-38750671

RESUMEN

BACKGROUND: Management of atrial fibrillation (AF) in very severe obese patients is challenging. Cryoballoon ablation (CBA) represents an effective rhythm control strategy. However, data in this patient group were limited. METHODS: Highly symptomatic AF patients with body mass index (BMI) ≥ 40 kg/m2 who had failed antiarrhythmic drug therapy and electrocardioversion and failure to achieve targeted body-weight-reduction underwent CBA. RESULTS: Data of 72 very severe obese AF patients (Group A) and 129 AF patients with normal BMI (Group B, BMI < 25 kg/m2) were consecutively collected. Group A had significantly younger age (60.6 ± 10.4 vs. 69.2 ± 11.2 years), higher BMI (44.3 ± 4.3 vs. 22.5 ± 1.6 kg/m2). Procedural pulmonary vein isolation (PVI) was successful in all patients (2 touch-up ablation in Group A). Compared to Group B, Group A had similar procedural (61.3 ± 22.6 vs. 57.5 ± 19 min), similar fluoroscopy time (10.1 ± 5.5 vs. 9.2 ± 4.8 min) but significantly higher radiation dose (2852 ± 2095 vs. 884 ± 732 µGym2). We observed similar rates of real-time-isolation (78.6% vs. 78.5%), single-shot-isolation (86.5% vs. 88.8%), but significantly longer time-to-sustained-isolation (53.5 ± 33 vs. 43.2 ± 25 s). There was significantly higher rate of puncture-site-complication (6.9% vs. 1.6%) in Group A. One-year clinical success in paroxysmal AF was (Group A: 69.4% vs. Group B: 80.2%; p < .001), in persistent AF was (Group A: 58.1% vs. Group B: 62.8%; p = .889). In Re-Do procedures Group A had a numerically lower PVI durability (75.0% vs. 83.6%, p = .089). CONCLUSION: For very severe obese AF patients, CBA appears feasible, leads to relatively good clinical outcome.

2.
Europace ; 26(6)2024 Jun 03.
Artículo en Inglés | MEDLINE | ID: mdl-38916275

RESUMEN

AIMS: Technological advancements have contributed to the enhanced precision and lesion flexibility in pulsed-field ablation (PFA) by integrating a three-dimensional mapping system combined with a point-by-point ablation strategy. Data regarding the feasibility of this technology remain limited to some clinical trials. This study aims to elucidate initial real-world data on catheter ablation utilizing a lattice-tip focal PFA/radiofrequency ablation (RFA) catheter in patients with persistent atrial fibrillation (AF). METHODS AND RESULTS: Consecutive patients who underwent catheter ablation for persistent AF via the lattice-tip PFA/RFA catheter were enrolled. We evaluated acute procedural data including periprocedural data as well as the clinical follow-up within a 90-day blanking period. In total, 28 patients with persistent AF underwent AF ablation either under general anaesthesia (n = 6) or deep sedation (n = 22). In all patients, pulmonary vein isolation was successfully achieved. Additional linear ablations were conducted in 21 patients (78%) with a combination of successful anterior line (n = 13, 46%) and roof line (n = 19, 68%). The median procedural and fluoroscopic times were 97 (interquartile range, IQR: 80-114) min and 8.5 (IQR: 7.2-9.5) min, respectively. A total of 27 patients (96%) were interviewed during the follow-up within the blanking period, and early recurrent AF was documented in four patients (15%) including one case of recurrent AF during the hospital stay. Neither major nor minor procedural complication occurred. CONCLUSION: In terms of real-world data, our data confirmed AF ablation feasibility utilizing the lattice-tip focal PFA/RFA catheter in patients with persistent AF.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Diseño de Equipo , Venas Pulmonares , Humanos , Fibrilación Atrial/cirugía , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Masculino , Ablación por Catéter/métodos , Ablación por Catéter/instrumentación , Femenino , Persona de Mediana Edad , Resultado del Tratamiento , Anciano , Venas Pulmonares/cirugía , Catéteres Cardíacos , Recurrencia , Factores de Tiempo
3.
J Electrocardiol ; 85: 37-38, 2024 May 29.
Artículo en Inglés | MEDLINE | ID: mdl-38830293

RESUMEN

We present the case of a 60-year-old male patient who was admitted to our hospital after experiencing a syncopal episode. First ECGs showed sinus rhythm with polymorphic premature ventricular complexes and later ventricular tachycardia with a left bundle branch block morphology were recorded. Imaging with TEE and MRI revealed a space-occupying lesion in the left ventricle, which was ultimately identified as a rare cardiac metastasis of renal cell carcinoma. Treatment was initiated with monoclonal antibodies resulting in lesion regression. This case highlights the importance of comprehensive diagnostic in patients with history of malignancy.

4.
J Cardiovasc Electrophysiol ; 34(12): 2425-2433, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37767744

RESUMEN

INTRODUCTION: Pulsed field ablation (PFA) is a new ablation technology for atrial fibrillation (AF). Data regarding early recurrences of atrial tachyarrhythmia (ERAT) after PFA-pulmonary vein isolation (PVI) are sparse. METHODS: Consecutive patients with symptomatic AF were enrolled to undergo PFA-PVI. A dedicated catheter delivering bipolar energy (1.9-2.0 kV) was used. Late recurrence (LR) was defined as documented AF/atrial tachycardia (AT) lasting more than 30 s after a 90-day blanking period. RESULTS: Two hundred and thirty-one patients (42% female, age 69 ± 12, 55% paroxysmal AF [PAF]) were included in this analysis. Median follow-up time was 367 days (interquartile range: 253-400). Forty-six patients (21%) experienced ERAT after a median of 23 days (46% in PAF and 54% in persistent AF [persAF]). Kaplan-Meier estimated freedom of AF/AT was 74.2% at 1 year, 81.8% for PAF, and 64.8% for persAF (p = .0079). Of patients experiencing ERAT, an LR was observed in 54%. There was no significant difference of LR between those who presented with very early ERAT (0-45 days) and those with ERAT (46-90 days) (p = .57). In multivariate analysis, ERAT (hazard ratio [HR]: 3.370; 95% confidence interval [95% CI]: 1.851-6.136; p < .001) and female sex (HR: 2.048; 95% CI: 1.114-3.768; p = .021) were the only independent predictors for LR. CONCLUSIONS: ERAT could be recorded in 21% of patients after PFA-PVI and was an independent predictor for LR. We found no difference in the rate of LRs among patients experiencing ERAT before or after 45 days.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Taquicardia Supraventricular , Humanos , Femenino , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Masculino , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Resultado del Tratamiento , Factores de Tiempo , Recurrencia , Atrios Cardíacos , Ablación por Catéter/efectos adversos , Venas Pulmonares/cirugía
5.
Europace ; 25(2): 433-440, 2023 02 16.
Artículo en Inglés | MEDLINE | ID: mdl-36427201

RESUMEN

AIMS: Pulsed-field ablation (PFA) can offer a novel perspective for atrial fibrillation (AF) ablation. We aimed to characterize the incidence of pulmonary vein (PV) reconnection, types of recurrent atrial tachyarrhythmia (ATa) and lesion quality after PFA-guided PV isolation (PVI). METHODS AND RESULTS: Patients undergoing second ablation for recurrent ATa following the initial PVI using the pentaspline PFA catheter were investigated. The rate of PV reconnection, the features of recurrent ATa, and the amount of isolated posterior wall (PW) surface area (ISAPW%) (ratio of the isolated- to total surface area on PW) were analyzed. RESULTS: Among 360 patients treated with PFA, 25 patients (paroxysmal AF, n = 19) with 99 PVs underwent a second procedure 6.1 ± 4.0 months after the initial procedure. The rate of PV reconnection was 9.1% (9 PVs). Patients presented with atrial tachycardia (AT) (n = 16), AF (n = 8) and typical atrial flutter (n = 1). The mechanism of all but one AT was macro-reentry. The critical isthmus was found to be linked to the initial lesion set at the left atrial (LA) PW in eight patients and linked to pre-existing substrate at the LA anterior wall in four patients. One AT had a focal origin at the septum. In three patients, AT were unmappable. Mean ISAPW% was 72.7 ± 19.0%. CONCLUSION: We revealed a remarkable low reconnection rate with a large antral lesion at the PW after pentaspline PFA catheter-guided PVI. However, macro-reentrant AT with a critical isthmus at the LAPW linked to the PVI lesion set was commonly observed.


Asunto(s)
Fibrilación Atrial , Aleteo Atrial , Ablación por Catéter , Venas Pulmonares , Taquicardia Supraventricular , Humanos , Venas Pulmonares/cirugía , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/etiología , Atrios Cardíacos , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Recurrencia , Resultado del Tratamiento
6.
Europace ; 25(5)2023 05 19.
Artículo en Inglés | MEDLINE | ID: mdl-37116126

RESUMEN

AIMS: A novel irrigated radiofrequency (RF) balloon (RFB) for pulmonary vein (PV) isolation (PVI) was released in selected centres. We pooled the procedural data on efficacy and safety of RFB-PVI from two high volume German centres. METHODS AND RESULTS: Consecutive patients with RFB procedures were enrolled. A 3D electroanatomical left atrial map guided the RFB navigation. Every RF delivery lasted 60 s, and duration was automatically reduced to 20 s for electrodes facing the posterior wall. Procedural data and post-procedural endoscopy data (<48 h) were analysed. Data from 140 patients were collected (57% male, 67 ± 11 years, 57% paroxysmal atrial fibrillation). There were 547 PVs identified, and 99.1% could be isolated using solely the RFB. Single-shot PVI was recorded in 330/547 (60%) PVs. Median time to isolation during the first application was 10 s (IQR 8-13). A total of 2.1 ± 1.8 applications per PV were delivered, with the left superior PV requiring more application compared to other PVs. Median procedure and fluoroscopy time were 77 min (61-99) and 13 min (10-17), respectively. Major safety events were recorded only in the first 25 cases at each centre and included 1/140(0.7%) cardiac tamponade, 1/140(0.7%) phrenic nerve palsy, and 2/140 strokes (1.4%). An oesophageal temperature rise was recorded in 81/547 (15%) PVs, and endoscopy detected oesophageal lesions in 7/85 (8%) patients undergoing endoscopy. CONCLUSION: The RFB showed a high efficacy allowing for fast PVI procedures, and 60% of PVs could be isolated at the first application. Most safety events were recorded during the learning phase. An oesophageal temperature monitoring is suggested: oesophageal lesions were detected in 8% of patients.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Masculino , Femenino , Resultado del Tratamiento , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/etiología , Atrios Cardíacos , Venas Pulmonares/cirugía
7.
Med Teach ; 38(5): 515-22, 2016 May.
Artículo en Inglés | MEDLINE | ID: mdl-27008432

RESUMEN

BACKGROUND: Germany's first student-run free clinic (SRFC) for medically underserved patients has been established at the medical faculty of the Goethe-University, Frankfurt/Germany. Participating students are educated in a Peer Assisted Learning program (PAL). Little is known about the effectiveness of PAL in SRFCs. METHODS: We conducted a randomized, controlled, prospective study involving 50 participants. Students were either tested before or after receiving PAL. Knowledge and skill level were measured by theoretical and practical tests. In addition, curricular Objective Structured Clinical Examination (OSCE) results were compared between the groups. RESULTS: Students receiving PAL had significantly better results in theoretical (p < 0.001) and practical (p < 0.001) tests, as well as in the OSCE (p < 0.01). A control test showed no significant difference (p = 0.205) indicating similar prerequisites between the groups. CONCLUSION: Improved results of the study group indicate an increase in the clinical knowledge and skills. PAL appears to be suitable for the training of basic medical skills and family medicine related knowledge and similar teaching projects could be based on it at other SRFCs.


Asunto(s)
Competencia Clínica , Educación de Pregrado en Medicina/métodos , Grupo Paritario , Clínica Administrada por Estudiantes , Femenino , Humanos , Masculino , Estudios Prospectivos
8.
J Interv Card Electrophysiol ; 67(4): 675-677, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38652213

RESUMEN

Catheter ablation of atrial fibrillation using non-thermal electroporation represents a promising ablation modality due to its believed superior safety profile. Still, if electroporation is delivered in proximity to a coronary artery, vasospasms can occur. We report the first case of severe right coronary artery vasospasm resulting in ST-segment elevation and AV block despite a remote distance from the ablation site to the right coronary artery, indicating a different mechanism. In this case, electroporation most likely triggered a previously unknown Prinzmetal vasospastic angina in the patient, resulting in the coronary vasospasm. Thus, meticulous monitoring of ST-segment changes following PFA delivery even from regions remote to coronary arteries is required.


Asunto(s)
Fibrilación Atrial , Bloqueo Atrioventricular , Ablación por Catéter , Vasoespasmo Coronario , Electrocardiografía , Humanos , Vasoespasmo Coronario/etiología , Vasoespasmo Coronario/diagnóstico por imagen , Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Bloqueo Atrioventricular/etiología , Bloqueo Atrioventricular/terapia , Masculino , Angina Pectoris Variable , Persona de Mediana Edad , Electroporación/métodos , Angiografía Coronaria , Femenino , Resultado del Tratamiento
9.
Artículo en Inglés | MEDLINE | ID: mdl-38573537

RESUMEN

BACKGROUND: Vascular complications are a common occurrence during atrial fibrillation ablation. Observational studies indicate that the utilization of ultrasound (US)-guided puncture may decrease the incidence of vascular complications; however, its routine use is not established in many centres. METHODS: Patients undergoing catheter ablation for atrial fibrillation were included sequentially. All patients receiving US-guided punctures were prospectively enrolled (US group), while patients who underwent the procedure with standard puncture technique served as control group (No-US group). Periprocedural vascular complications requiring intervention within 30 days of the procedure were defined as the primary endpoint. RESULTS: A total of 599 patients (average age: 69 ± 11 years, 62.9% male) were analysed. The incidence of vascular complications was lower with the US-guided puncture than with the anatomic landmark-guided puncture (14/299 [4.7%] vs. 27/300 [9%], p = 0.036). The US-guided vascular access significantly reduced the rate of false aneurysms (3/299 [1%] vs. 12/300 [4%], p = 0.019). In addition, the occurrence of arteriovenous fistula (2/299 [0.7%] vs. 4/300 [1.3%], p = 0.686) and haematoma requiring treatment (9/299 [3%] vs. 11/300 [3.7%], p = 0.655) were also lower in the US group. US-guided puncture did not prolong the procedure time (mean procedure time: 57.48 ± 24.47 min vs. 56.09 ± 23.36 min, p = 0.478). Multivariate regression analysis identified female gender (OR 2.079, CI 95% 1.096-3.945, p = 0.025) and conventional vascular access (OR 2.079, CI 95% 1.025-3.908, p = 0.042) as predictors of vascular complications. CONCLUSIONS: The implementation of US-guided vascular access for left atrial catheter ablation resulted in a significant decrease of the overall vascular complication rate.

10.
Artículo en Inglés | MEDLINE | ID: mdl-37427302

RESUMEN

Catheter ablation is a widely used, effective and safe treatment for AF. Pulsed field ablation (PFA), as a novel energy source for cardiac ablation, has been shown to be tissue selective and is expected to decrease damage to non-cardiac tissue while providing high efficacy in pulmonary vein isolation. The FARAPULSE ablation system (Boston Scientific) follows the idea of single-shot ablation and is the first device approved for clinical use in Europe. Since its approval, multiple high-volume centres have performed increasing numbers of PFA procedures in patients with AF and have published their experiences. This review summarises the current clinical experience regarding the use of PFA for AF using the FARAPULSE system. It provides an overview of its efficacy and safety.

11.
JACC Clin Electrophysiol ; 9(9): 1864-1875, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37480870

RESUMEN

BACKGROUND: Although the autonomic reaction such as bradycardia is observed frequently during pulsed-field ablation (PFA)-guided pulmonary vein isolation (PVI), its mechanism and effect on the adjacent intrinsic cardiac autonomic nervous system (ICANS) are unclear. OBJECTIVES: This study aimed to reveal the clinical impact of PFA on ICANS by investigating the serum S100 increase (ΔS100), a well-known denervation relevant biomarker. METHODS: Pre- and postprocedural serum S100 analyses were systematically conducted in patients undergoing PVI using either the pentaspline PFA or cryoballoon ablation (CBA) system. ΔS100 release kinetics were compared between both technologies. Cerebral magnetic resonance imaging was conducted to eliminate the effect of central nervous system release. RESULTS: A total of 97 patients (PFA: n = 54 and CBA: n = 43) were enrolled. Overall S100 increased in both groups with a lower amount in PFA (0.035 µg/L; IQR: 0.02-0.063 µg/L) compared with CBA (0.12 µg/L; IQR: 0.09-0.17 µg/L; P < 0.0001). In cerebral magnetic resonance imaging, silent emboli were detected in 10 patients (18.5%) in PFA and 7 patients (16.3%) in CBA (P = 0.773). Even after excluding patients with cerebral emboli, ΔS100 was lower in PFA. During PFA PVI, 30 patients (56%) demonstrated transient bradycardia in 70 of 210 PVs (35%). ΔS100 was similar between patients with or without transient bradycardia. CONCLUSIONS: We report a significantly lower S100 release following PFA PVI vs CBA PVI even if silent cerebral emboli were excluded. Notably, vagal response during PFA was not associated with S100 release. These observations are in line with lower nervous tissue destruction of PFA compared with CBA.


Asunto(s)
Embolia Intracraneal , Venas Pulmonares , Humanos , Bradicardia , Venas Pulmonares/cirugía , Corazón , Sistema Nervioso Autónomo
12.
Circ Arrhythm Electrophysiol ; 16(7): 389-398, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37254781

RESUMEN

BACKGROUND: The cryoballoon (CB) represents the gold standard single-shot device for pulmonary vein isolation (PVI) in patients with atrial fibrillation (AF). Single-shot pulsed field PVI ablation (nonthermal, cardiac tissue selective) has recently entered the arena. We sought to compare procedural data and long-term outcome of both techniques. METHODS: Consecutive AF patients who underwent pulsed field ablation (PFA) and CB-based PVI were enrolled. CB PVI was performed using the second-generation 28-mm CB; PFA was performed using a 31/35-mm pentaspline catheter. Success was defined as freedom from atrial tachyarrhythmia after a 3-month blanking period. RESULTS: Four hundred patients were included (56.5% men; 60.8% paroxysmal AF; age 70 [interquartile range, 59-77] years), 200 in each group (CB and PFA), and baseline characteristics did not differ. Acute PVI was achieved in 100% of PFA and in 98% (196/200) of CB patients (P=0.123; 4 touch-up ablations). Median procedure time was significantly shorter in PFA (34.5 [29-40] minutes) versus CB (50 [45-60] minutes; P<0.001), fluoroscopy time was similar. Overall procedural complications were 6.5% in CB and 3.0% in PFA (P=0.1), driven by a higher rate of phrenic nerve palsies using CB. The 1-year success rates in paroxysmal AF (CB, 83.1%; PFA, 80.3%; P=0.724) and persistent AF (CB, 71%; PFA, 66.8%; P=0.629) were similar for both techniques. CONCLUSIONS: PFA compared with CB PVI shows a similar procedural efficacy but is associated with shorter procedure time and no phrenic nerve palsies. Importantly, 12-month clinical success rates are favorable but not different between both groups.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Masculino , Humanos , Anciano , Femenino , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Estudios de Seguimiento , Resultado del Tratamiento , Venas Pulmonares/cirugía , Parálisis/cirugía , Ablación por Catéter/métodos , Recurrencia
13.
Herzschrittmacherther Elektrophysiol ; 33(4): 367-372, 2022 Dec.
Artículo en Alemán | MEDLINE | ID: mdl-36131155

RESUMEN

Metabolic syndrome is defined by the simultaneous occurrence of the cardiovascular risk factors obesity, hypertension, diabetes and dyslipidemia. Overweight, in particular, is continuously increasing in many countries. In this respect, metabolic syndrome is a strong risk factor for atrial fibrillation. Only few data are available on the influence of obesity on antiarrhythmic drugs. Sodium channel blockers, in particular, appear to show a reduced effectiveness. Direct oral anticoagulants can be used for anticoagulation in obese patients. With a body weight > 140 kg, a plasma level measurement is recommended. Severe overweight reduces the chances of successful ablation treatment and leads to more complications. Consistent treatment of the metabolic syndrome, and in particular weight reduction, can significantly improve the risk and the frequency of atrial fibrillation, the associated symptoms and the success of treatment for maintaining cardiac rhythm.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Síndrome Metabólico , Humanos , Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Síndrome Metabólico/complicaciones , Síndrome Metabólico/tratamiento farmacológico , Síndrome Metabólico/cirugía , Sobrepeso/complicaciones , Sobrepeso/tratamiento farmacológico , Sobrepeso/cirugía , Antiarrítmicos/uso terapéutico , Anticoagulantes/uso terapéutico , Obesidad/complicaciones , Obesidad/epidemiología , Obesidad/cirugía
17.
Appl Opt ; 41(7): 1282-90, 2002 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-11900005

RESUMEN

Applications of optical systems, including depth by focus and three-dimensional metrology, have been developed recently in which the image is characterized over a range of object depths simultaneously and in which the focus of the systems is also varied. Important to such applications is the variation of image magnification with focus. A general understanding of this phenomenon is developed, and two new and useful concepts associated with the variation of the magnification of an image are introduced. Errors and oversights in the existing literature are explained and corrected, and the requirements for an optical system to exhibit the magnification properties desired in such applications are identified. It is shown that not all telecentric systems have these properties and that there exist practical and attractive nontelecentric systems that do exhibit them.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA