Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 976
Filtrar
Más filtros

Tipo del documento
Intervalo de año de publicación
1.
Circulation ; 148(1): 35-46, 2023 07 04.
Artículo en Inglés | MEDLINE | ID: mdl-37199171

RESUMEN

BACKGROUND: Pulsed field ablation is a novel nonthermal cardiac ablation modality using ultra-rapid electrical pulses to cause cell death by a mechanism of irreversible electroporation. Unlike the traditional ablation energy sources, pulsed field ablation has demonstrated significant preferentiality to myocardial tissue ablation, and thus avoids certain thermally mediated complications. However, its safety and effectiveness remain unknown in usual clinical care. METHODS: MANIFEST-PF (Multi-National Survey on the Methods, Efficacy, and Safety on the Post-Approval Clinical Use of Pulsed Field Ablation) is a retrospective, multinational, patient-level registry wherein patients at each center were prospectively included in their respective center registries. The registry included all patients undergoing postapproval treatment with a multielectrode 5-spline pulsed field ablation catheter to treat atrial fibrillation (AF) between March 1, 2021, and May 30, 2022. The primary effectiveness outcome was freedom from clinical documented atrial arrhythmia (AF/atrial flutter/atrial tachycardia) of ≥30 seconds on the basis of electrocardiographic data after a 3-month blanking period (on or off antiarrhythmic drugs). Safety outcomes included the composite of acute (<7 days postprocedure) and latent (>7 days) major adverse events. RESULTS: At 24 European centers (77 operators) pulsed field ablation was performed in 1568 patients with AF: age 64.5±11.5 years, female 35%, paroxysmal/persistent AF 65%/32%, CHA2DS2-VASc 2.2±1.6, median left ventricular ejection fraction 60%, and left atrial diameter 42 mm. Pulmonary vein isolation was achieved in 99.2% of patients. After a median (interquartile range) follow-up of 367 (289-421) days, the 1-year Kaplan-Meier estimate for freedom from atrial arrhythmia was 78.1% (95% CI, 76.0%-80.0%); clinical effectiveness was more common in patients with paroxysmal AF versus persistent AF (81.6% versus 71.5%; P=0.001). Acute major adverse events occurred in 1.9% of patients. CONCLUSIONS: In this large observational registry of the postapproval clinical use of pulsed field technology to treat AF, catheter ablation using pulsed field energy was clinically effective in 78% of patients with AF.


Asunto(s)
Fibrilación Atrial , Aleteo Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Femenino , Persona de Mediana Edad , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/tratamiento farmacológico , Estudios Retrospectivos , Volumen Sistólico , Función Ventricular Izquierda , Resultado del Tratamiento , Aleteo Atrial/etiología , Sistema de Registros , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Recurrencia
2.
J Cardiovasc Electrophysiol ; 35(3): 511-515, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38225537

RESUMEN

INTRODUCTION: Atrial fibrillation and atrial flutter originating from the donor s heart is a commonly reported complication post heart transplant. Atrial tachyarrhythmia originating from the recipient s heart, propagated through recipient-to-donor connections, is rare with only few cases reported in the literature; most reported cases from our review occur years post-transplant. CASE: A 47-year-old male presented with atrial tachycardia 6 months post heart transplant. Electrophysiologic study demonstrated atrial fibrillation originating from native heart and propagated through atrio-atrial connections to the donor heart. This arrhythmia was successfully terminated with radiofrequency ablation. CONCLUSION: Atrio-atrial connection between recipient and donor can form as early as a few months post heart transplant. Radiofrequency ablation appears to be an effective treatment for atrial fibrillation propagated through donor-to-recipient connections.


Asunto(s)
Fibrilación Atrial , Aleteo Atrial , Ablación por Catéter , Trasplante de Corazón , Masculino , Humanos , Persona de Mediana Edad , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/etiología , Fibrilación Atrial/cirugía , Trasplante de Corazón/efectos adversos , Ablación por Catéter/efectos adversos , Donantes de Tejidos , Aleteo Atrial/diagnóstico , Aleteo Atrial/etiología , Aleteo Atrial/cirugía
3.
Europace ; 26(6)2024 Jun 03.
Artículo en Inglés | MEDLINE | ID: mdl-38934242

RESUMEN

AIMS: Wild-type transthyretin amyloid cardiomyopathy (ATTRwt-CM) is often accompanied by atrial fibrillation (AF), atrial flutter (AFL), and atrial tachycardia (AT), which are difficult to control because beta-blockers and antiarrhythmic drugs can worsen heart failure (HF). This study aimed to investigate the outcomes of catheter ablation (CA) for AF/AFL/AT in patients with ATTRwt-CM and propose a treatment strategy for CA. METHODS AND RESULTS: A cohort study was conducted on 233 patients diagnosed with ATTRwt-CM, including 54 who underwent CA for AF/AFL/AT. The background of each arrhythmia and the details of the CA and its outcomes were investigated. The recurrence-free rate of AF/AFL/AT overall in ATTRwt-CM patients with multiple CA was 70.1% at 1-year, 57.6% at 2-year, and 44.0% at 5-year follow-up, but CA significantly reduced all-cause mortality [hazard ratio (HR): 0.342, 95% confidence interval (CI): 0.133-0.876, P = 0.025], cardiovascular mortality (HR: 0.378, 95% CI: 0.146-0.981, P = 0.045), and HF hospitalization (HR: 0.488, 95% CI: 0.269-0.889, P = 0.019) compared with those without CA. There was no recurrence of the cavotricuspid isthmus (CTI)-dependent AFL, non-CTI-dependent simple AFL terminated by one linear ablation, and focal AT originating from the atrioventricular (AV) annulus or crista terminalis eventually. Twelve of 13 patients with paroxysmal AF and 27 of 29 patients with persistent AF did not have recurrence as AF. However, all three patients with non-CTI-dependent complex AFL not terminated by a single linear ablation and 10 of 13 cases with focal AT or multiple focal ATs originating beyond the AV annulus or crista terminalis recurred even after multiple CA. CONCLUSION: The outcomes of CA for ATTRwt-CM were acceptable, except for multiple focal AT and complex AFL. Catheter ablation may be aggressively considered as a treatment strategy with the expectation of improving mortality and hospitalization for HF.


Asunto(s)
Neuropatías Amiloides Familiares , Fibrilación Atrial , Aleteo Atrial , Cardiomiopatías , Ablación por Catéter , Humanos , Ablación por Catéter/efectos adversos , Masculino , Aleteo Atrial/cirugía , Aleteo Atrial/etiología , Femenino , Fibrilación Atrial/cirugía , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Anciano , Neuropatías Amiloides Familiares/cirugía , Neuropatías Amiloides Familiares/complicaciones , Neuropatías Amiloides Familiares/mortalidad , Cardiomiopatías/mortalidad , Cardiomiopatías/terapia , Resultado del Tratamiento , Persona de Mediana Edad , Recurrencia , Taquicardia Supraventricular/cirugía , Taquicardia Supraventricular/etiología , Taquicardia Supraventricular/fisiopatología , Taquicardia Supraventricular/diagnóstico , Estudios Retrospectivos , Prealbúmina/genética , Prealbúmina/metabolismo
4.
Am Heart J ; 263: 141-150, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37271358

RESUMEN

BACKGROUND: Adults with repaired tetralogy of Fallot (TOF) have right atrial (RA) remodeling and dysfunction, and RA function can be measured using speckle tracking echocardiography. There are limited data about the role of RA strain imaging for risk stratification in this population. We hypothesized that RA reservoir strain can identify TOF patients at risk of developing atrial arrhythmia. To test this hypothesis, we assessed the relationship between RA reservoir strain and atrial arrhythmias in adults with repaired TOF. METHOD: Retrospective cohort study of adults with repaired TOF, and no prior history of atrial arrhythmias. Atrial arrhythmia was defined as atrial fibrillation, atrial flutter/atrial tachycardia, and categorized as new-onset versus recurrent atrial arrhythmias. RESULTS: We identified 426 patients (age 33 ± 12 years; males 208 (49%)) that met the inclusion criteria. The mean RA reservoir strain, conduit strain, and booster strain were 34 ± 11%, 20 ± 9%, and 15 ± 12%, respectively. Of 426 patients, 73 (17%) developed new-onset atrial arrhythmias (atrial flutter/tachycardia n = 42; atrial fibrillation n = 31); annual incidence 1.9%. RA reservoir strain was associated with new-onset atrial arrhythmias (adjusted HR 0.95, 95% CI 0.93-0.97) after multivariable adjustment. Of 73 patients with new-onset atrial arrhythmia, 41 (56%) had recurrent atrial arrhythmia (atrial flutter/tachycardia n = 18; atrial fibrillation n = 23); annual incidence 11.2%. Similarly, RA reservoir strain was associated with recurrent atrial arrhythmias (adjusted HR 0.92, 95% CI 0.88-0.96) after multivariable adjustment. CONCLUSIONS: RA strain indices can identify patients at risk for atrial arrhythmias, and this can in turn, be used to guide the type/intensity of therapy in such patients.


Asunto(s)
Fibrilación Atrial , Aleteo Atrial , Taquicardia Supraventricular , Tetralogía de Fallot , Masculino , Humanos , Adulto , Adulto Joven , Persona de Mediana Edad , Fibrilación Atrial/epidemiología , Fibrilación Atrial/etiología , Fibrilación Atrial/terapia , Aleteo Atrial/epidemiología , Aleteo Atrial/etiología , Aleteo Atrial/terapia , Tetralogía de Fallot/complicaciones , Tetralogía de Fallot/cirugía , Estudios Retrospectivos , Taquicardia
5.
J Cardiovasc Electrophysiol ; 34(10): 2145-2151, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-36598419

RESUMEN

The exponential rise in the incidence of peri-mitral flutter has paralleled the increasing use of more extensive atrial substrate ablation for atrial fibrillation (AF). Given the relative paucity of randomized evidence to support its role in AF management, mitral isthmus ablation should largely be reserved for patients with peri-mitral flutter. Catheter ablation for peri-mitral flutter is challenging due to complex anatomic relationships. The aim of this report is to review the anatomic considerations and approaches to catheter ablation for peri-mitral flutter.


Asunto(s)
Fibrilación Atrial , Aleteo Atrial , Ablación por Catéter , Humanos , Aleteo Atrial/diagnóstico , Aleteo Atrial/cirugía , Aleteo Atrial/etiología , Resultado del Tratamiento , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/complicaciones , Ablación por Catéter/efectos adversos , Incidencia
6.
Europace ; 25(9)2023 08 02.
Artículo en Inglés | MEDLINE | ID: mdl-37470443

RESUMEN

AIMS: Electro-anatomical mapping may be critical to identify atrial fibrillation (AF) subjects who require substrate modification beyond pulmonary vein isolation (PVI). The objective was to determine correlations between pre-ablation mapping characteristics and 12-month outcomes after a single PVI-only catheter ablation of AF. METHODS AND RESULTS: This study enrolled paroxysmal AF (PAF), early persistent AF (PsAF; 7 days-3 months), and non-early PsAF (>3-12 months) subjects undergoing de novo PVI-only radiofrequency catheter ablation. Sinus rhythm (SR) and AF voltage maps were created with the Advisor HD Grid™ Mapping Catheter, Sensor Enabled™ for each subject, and the presence of low-voltage area (LVA) (low-voltage cutoffs: 0.1-1.5 mV) was investigated. Follow-up visits were at 3, 6, and 12 months, with a 24-h Holter monitor at 12 months. A Cox proportional hazards model identified associations between mapping data and 12-month recurrence after a single PVI procedure. The study enrolled 300 subjects (113 PAF, 86 early PsAF, and 101 non-early PsAF) at 18 centres. At 12 months, 75.5% of subjects were free from AF/atrial flutter (AFL)/atrial tachycardia (AT) recurrence. Univariate analysis found that arrhythmia recurrence did not correlate with AF diagnosis, but LVA was significantly correlated. Low-voltage area (<0.5 mV) >28% of the left atrium in SR [hazard ratio (HR): 4.82, 95% confidence interval (CI): 2.08-11.18; P = 0.0003] and >72% in AF (HR: 5.66, 95% CI: 2.34-13.69; P = 0.0001) was associated with a higher risk of AF/AFL/AT recurrence at 12 months. CONCLUSION: Larger extension of LVA was associated with an increased risk of arrhythmia recurrence. These subjects may benefit from substrate modification beyond PVI.


Asunto(s)
Fibrilación Atrial , Aleteo Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Venas Pulmonares/cirugía , Frecuencia Cardíaca , Resultado del Tratamiento , Técnicas Electrofisiológicas Cardíacas , Recurrencia , Factores de Tiempo , Atrios Cardíacos , Aleteo Atrial/diagnóstico , Aleteo Atrial/cirugía , Aleteo Atrial/etiología , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos
7.
Europace ; 26(1)2023 12 28.
Artículo en Inglés | MEDLINE | ID: mdl-38102318

RESUMEN

AIMS: In-hospital complications of catheter ablation for atrial fibrillation (AF), atrial flutter (AFL), and ventricular tachycardia (VT) may be overestimated by analyses of administrative data. METHODS AND RESULTS: We determined the incidences of in-hospital mortality, major bleeding, and stroke around AF, AFL, and VT ablations in four German tertiary centres between 2005 and 2020. All cases were coded by the G-DRG- and OPS-systems. Uniform code search terms were applied defining both the types of ablations for AF, AFL, and VT and the occurrence of major adverse events including femoral vascular complications, iatrogenic tamponade, stroke, and in-hospital death. Importantly, all complications were individually reviewed based on patient-level source records. Overall, 43 031 ablations were analysed (30 361 AF; 9364 AFL; 3306 VT). The number of ablations/year more than doubled from 2005 (n = 1569) to 2020 (n = 3317) with 3 times and 2.5 times more AF and VT ablations in 2020 (n = 2404 and n = 301, respectively) as compared to 2005 (n = 817 and n = 120, respectively), but a rather stable number of AFL ablations (n = 554 vs. n = 612). Major peri-procedural complications occurred in 594 (1.4%) patients. Complication rates were 1.1% (n = 325) for AF, 1.0% (n = 95) for AFL, and 5.3% (n = 175) for VT. With an increase in complex AF/VT procedures, the overall complication rate significantly increased (0.76% in 2005 vs. 1.81% in 2020; P = 0.004); but remained low over time. Following patient-adjudication, all in-hospital cardiac tamponades (0.7%) and strokes (0.2%) were related to ablation. Major femoral vascular complications requiring surgical intervention occurred in 0.4% of all patients. The in-hospital mortality rate adjudicated to be ablation-related was lower than the coded mortality rate: AF: 0.03% vs. 0.04%; AFL: 0.04% vs. 0.14%; VT: 0.42% vs. 1.48%. CONCLUSION: Major adverse events are low and comparable after catheter ablation for AFL and AF (∼1.0%), whereas they are five times higher for VT ablations. In the presence of an increase in complex ablation procedures, a moderate but significant increase in overall complications from 2005-20 was observed. Individual case analysis demonstrated a lower than coded ablation-related in-hospital mortality. This highlights the importance of individual case adjudication when analysing administrative data.


Asunto(s)
Fibrilación Atrial , Aleteo Atrial , Ablación por Catéter , Accidente Cerebrovascular , Taquicardia Ventricular , Humanos , Mortalidad Hospitalaria , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/epidemiología , Aleteo Atrial/diagnóstico , Aleteo Atrial/cirugía , Aleteo Atrial/etiología , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/epidemiología , Taquicardia Ventricular/cirugía , Hospitales , Accidente Cerebrovascular/epidemiología , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Resultado del Tratamiento
8.
Pediatr Transplant ; 27(1): e14410, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36314299

RESUMEN

BACKGROUND: Atrial arrhythmia's (AA) following lung transplant in adults are a well-described clinical finding. In pediatrics, however, there are limited data with some reports suggesting that arrhythmias are rare. METHODS: We performed a single-center retrospective review of lung transplant recipients from January 2013 to June 2020. A detailed evaluation of clinical characteristics, presence of arrhythmias, and outcomes was completed. Arrhythmias were documented based on inpatient telemetry or remote Holter monitoring. Analyses assessing risk factors for arrhythmias and associations with clinical outcomes were performed. RESULTS: Ninety-one lung transplants were performed in 90 patients. Post-operative AA occurred following 19% transplants. Ectopic atrial tachycardia was seen in 14%, atrial flutter in 2%, and a combination in 2%. The majority of these arrhythmias occurred within the first 45 days post-operatively. Antiarrhythmic treatment was required in 59%, but none required ablation or electrical cardioversion. In patients followed for a year or more, 88% had resolution of their arrhythmia. Arrhythmias were not associated with mortality. In further analysis, however, the presence of arrhythmia was associated with an increased length of ICU stay (median of 12 days (IQR 6, 23) versus 5 days (IQR 4, 9); p = .019) and overall length of hospital stay (median of 26 days (IQR 19, 36) versus 17 days (IQR 19, 36); p = .043). CONCLUSIONS: Atrial tachyarrhythmias after lung transplantation are common in the pediatric population and usually occur early. Although they frequently require medical therapy and are associated with longer stays, there is no associated increased mortality. In addition, the arrhythmias typically self-resolve.


Asunto(s)
Fibrilación Atrial , Aleteo Atrial , Trasplante de Pulmón , Taquicardia Supraventricular , Adulto , Niño , Humanos , Fibrilación Atrial/etiología , Fibrilación Atrial/terapia , Fibrilación Atrial/epidemiología , Taquicardia/terapia , Taquicardia/complicaciones , Taquicardia Supraventricular/etiología , Aleteo Atrial/etiología , Aleteo Atrial/terapia , Trasplante de Pulmón/efectos adversos
9.
Pacing Clin Electrophysiol ; 46(10): 1239-1241, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-36856337

RESUMEN

BACKGROUND: 51-year-old female with extensive prior atrial surgery involving myxoma resection and patch septum repair and prior typical atrial flutter as well as peripatch reentry underwent redo radiofrequency ablation of typical atrial flutter. METHODS: After high density mapping was performed, and gap in the prior typical flutter line was ablated. RESULT: During the ablation transient atrioventricular (AV) block was noted. Subsequent remapping of the right atrium revealed that there was a narrow strip of tissue between the cavo-tricuspid isthmus (CTI) and the coronary sinus (CS) os on which activation of the AV node was now depending. From all other directions, the AV node was surrounded by scar tissue. CONCLUSIONS: The most likely explanation for the transient AV block during the ablation procedure is that there was reversible injury to the tissue strip between the CTI and the CS os, which is critical for the activation of the AV node.


Asunto(s)
Aleteo Atrial , Bloqueo Atrioventricular , Ablación por Catéter , Femenino , Humanos , Persona de Mediana Edad , Aleteo Atrial/etiología , Aleteo Atrial/cirugía , Electrocardiografía/métodos , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Nodo Atrioventricular
10.
Ann Noninvasive Electrocardiol ; 28(2): e13010, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36165099

RESUMEN

Atrial flutter (AFL) is the second most common atrial tachyarrhythmia after atrial fibrillation. Catheter ablation (CA) for typical AFL is well-established and has a high success rate and adequate safety. However, sick sinus syndrome (SSS) occasionally occurs when long-term, persistent AFL is terminated by ablation. Sinus node function cannot be assessed during AFL, and the preoperative prediction of underlying SSS has not yet been investigated. When this situation occurs, pacemaker implantation is often necessary. Here, we report a case of SSS after persistent AFL CA.


Asunto(s)
Fibrilación Atrial , Aleteo Atrial , Ablación por Catéter , Humanos , Aleteo Atrial/etiología , Aleteo Atrial/cirugía , Síndrome del Seno Enfermo/cirugía , Electrocardiografía , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Resultado del Tratamiento
11.
J Cardiovasc Electrophysiol ; 33(6): 1190-1196, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35362181

RESUMEN

BACKGROUND: The two most common postoperative atrial flutter (AFL) circuits after right atriotomy are the cavotricuspid isthmus (CTI) dependent and the lateral, peri-incisional. We investigated whether radiofrequency ablation (RFA) of both circuits results in more favorable long-term outcomes. METHODS: Single-center retrospective cohort study of consecutive patients who underwent RFA of AFL after open-heart surgery. The effect of surgery type and RFA strategy on AFL recurrence was evaluated. RESULTS: One hundred and forty-two patients (mean age 64.5 ± 12.7 years, 65.% male) were enrolled. Patients with right atrial (RA) flutter (n = 124) were divided into two groups based on the index RFA procedure: only one RA circuit was ablated (Group 1, n = 84, 67.7%) or both the CTI and the peri-incisional circuit ablated (Group 2, n = 40, 32.3%). The previous open-heart surgery was categorized based on the extension of the RA incision: limited (Type A) or extended (Type B) atriotomy. After a mean follow-up of 36 ± 28 months, flutter recurrence was not different among patients with limited RA atriotomy (25% vs. 22% in Groups 1A and 2A, respectively, p = 1.0). However, after type B surgery, ablation of both AFL circuits was associated with a reduced recurrence rate (63% vs. 26% in Groups 1B and 2B, respectively, p = .002). CONCLUSIONS: In patients with postoperative RA flutter after extended right atriotomy, ablation of both the CTI and the peri-incisional isthmus significantly reduces the AFL recurrence rate. Prophylactic ablation of both isthmi, even if not proven to support reentry, is reasonable in this population.


Asunto(s)
Aleteo Atrial , Ablación por Catéter , Anciano , Arritmias Cardíacas/cirugía , Aleteo Atrial/diagnóstico , Aleteo Atrial/etiología , Aleteo Atrial/prevención & control , Ablación por Catéter/efectos adversos , Femenino , Atrios Cardíacos , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
12.
J Cardiovasc Electrophysiol ; 33(8): 1655-1664, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35598280

RESUMEN

INTRODUCTION: To target posterior wall isolation (PWI) in atrial fibrillation (AF) ablation, diffuse ablation theoretically confers a lower risk of conduction recovery compared to box set. We sought to assess the safety and efficacy of diffuse PWI with low-flow, medium-power, and short-duration (LF-MPSD) ablation, and evaluate the durability of pulmonary vein isolation (PVI) and PWI among patients undergoing repeat ablations. METHODS: We retrospectively studied patients undergoing LF-MPSD ablation for AF (PVI + diffuse PWI) between August 2017 and December 2019. Clinical characteristics were collected. Kaplan-Meier survival analysis was performed to study AF/atrial flutter (AFL) recurrence. Ablation data were analyzed in patients who underwent a repeat AF/AFL ablation. RESULTS: Of the 463 patients undergoing LF-MPSD AF ablation (PVI alone, or PVI + diffuse PWI), 137 patients had PVI + diffuse PWI. Acute PWI with complete electrocardiogram elimination was achieved in 134 (97.8%) patients. Among the 126 patients with consistent follow-up, 38 (30.2%) patients had AF/AFL recurrence during a median duration of 14 months. Eighteen patients underwent a repeat AF/AFL ablation after PVI + diffuse PWI, and 16 (88.9%) patients had durable PVI, in contrast to 10 of 45 (23.9%) patients who had redo ablation after LF-MPSD PVI alone. Seven patients (38.9%) had durable PWI, while 11 patients had partial electrical recovery at the posterior wall. The median percentage of area without electrical activity at the posterior wall was 70.7%. Conduction block across the posterior wall was maintained in 16 (88.9%) patients. CONCLUSION: There was a high rate of PVI durability in patients undergoing diffuse PWI and PVI. Partial posterior wall electrical recovery was common but conduction block across the posterior wall was maintained in most patients.


Asunto(s)
Fibrilación Atrial , Aleteo Atrial , Ablación por Catéter , Venas Pulmonares , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/etiología , Fibrilación Atrial/cirugía , Aleteo Atrial/diagnóstico , Aleteo Atrial/etiología , Aleteo Atrial/cirugía , Ablación por Catéter/efectos adversos , Humanos , Venas Pulmonares/cirugía , Recurrencia , Estudios Retrospectivos , Resultado del Tratamiento
13.
J Cardiovasc Electrophysiol ; 33(1): 40-45, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34676946

RESUMEN

BACKGROUND: Cavo-tricuspid isthmus (CTI) linear ablation is performed not only for atrial flutter (AFL) but empirically during atrial fibrillation (AF) ablation in real-world practice.  PURPOSE: We sought to evaluate the safety and durability of the CTI ablation.  METHODS: This retrospective study included 1078 consecutive patients who underwent a CTI ablation. AFL was documented before or during the procedure in 249 (23.1%) patients, and an empirical CTI and AF ablation were performed in 829 (76.9%) patients.  RESULTS: CTI block was successfully created in 1051 (97.5%) patients with a 10.3 ± 6.6 min total radiofrequency time. Repeat procedures were performed for recurrent arrhythmias in 187 (17.3%) patients at a median of 11.0 (5.0-30.0) months postprocedure, and conduction resumption was identified in 68/174 (39.1%). Among those undergoing a CTI ablation with an AF ablation, the durability was significantly higher in those with than without documented AFL (78.1% vs. 58.2%, p = .031).  The total radiofrequency time was significantly shorter (9.0 ± 5.3 vs. 10.0 ± 6.4 [mins], p = .024) and durability significantly higher (78.1 vs. 58.7[%], p = .043) in the large-tip than irrigated-tip catheter group. Iatrogenic AFL was observed after the empiric CTI ablation in 11 (1.3%) patients. Procedure-related complications occurred in 15 (1.4%) patients. Eight patients experienced coronary artery spasms, including one with ventricular fibrillation following ST elevation on the ward. The other six patients experienced transient atrioventricular block and one experienced cardiac tamponade requiring drainage.  CONCLUSIONS: Despite a high acute CTI ablation success, the conduction block durability was relatively low after the empiric ablation. An empiric CTI ablation at the time of the AF ablation is not recommended.


Asunto(s)
Fibrilación Atrial , Aleteo Atrial , Ablación por Catéter , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/etiología , Fibrilación Atrial/cirugía , Aleteo Atrial/diagnóstico , Aleteo Atrial/etiología , Aleteo Atrial/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Humanos , Estudios Retrospectivos , Resultado del Tratamiento
14.
J Cardiovasc Electrophysiol ; 33(5): 932-942, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35224802

RESUMEN

BACKGROUND: Ablation of atrial arrhythmias in patients with congenital heart disease (CHD) has markedly improved with advanced mapping systems. However, recurrence rates remain high. The linear ablation strategy is not uncommonly practiced necessitating prolonged ablation times. We report the outcomes of adopting a strategy of minimal, cluster delivery of radiofrequency (RF) energy at critical substrates identified by ultrahigh-definition mapping for atrial arrhythmias in patients with CHD. METHODS: Non-cavotricuspid isthmus (non-CTI) atrial tachycardias were ablated with a targeted ablation cluster technique (TACT) using an ultrahigh-density mapping system combined with multielectrode monitoring and endpoint determination in preference to linear ablation. The arrhythmia substrates, RF times, and acute- and medium-term success rates were studied. RESULTS: Fifty-eight tachycardias were mapped and ablated in 42 procedures: 34 non-CTIs and 24 CTIs. A targeted ablation cluster was performed for non-CTI tachycardias, with a median ablation time of 3.1 min. In 53% of non-CTI tachycardias, arrhythmia termination was achieved with ≤2 RF applications. After a mean follow-up of 23.6 months, 27 (80%) patients were free of recurrent atrial arrhythmias. One of 34 targeted non-CTI tachycardia recurred, with a final success rate of 91%. Linear ablation was performed for CTI flutters with a median ablation time of 6.8 min (vs. non-CTIs, p = .006). Three of 21 tachycardias recurred due to reconnection of the ablation line but the final success rate was 100%. CONCLUSIONS: The TACT approach for non-CTI atrial arrhythmias in congenital patients as guided by the ultrahigh-density mapping is an effective method with short ablation times and excellent medium-term outcomes.


Asunto(s)
Aleteo Atrial , Ablación por Catéter , Cardiopatías Congénitas , Aleteo Atrial/diagnóstico , Aleteo Atrial/etiología , Aleteo Atrial/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Cardiopatías Congénitas/diagnóstico , Cardiopatías Congénitas/diagnóstico por imagen , Humanos , Taquicardia/cirugía , Resultado del Tratamiento
15.
Europace ; 24(7): 1186-1194, 2022 07 21.
Artículo en Inglés | MEDLINE | ID: mdl-35045172

RESUMEN

AIMS: Atrial flutter (AFlut) is a common re-entrant atrial tachycardia driven by self-sustainable mechanisms that cause excitations to propagate along pathways different from sinus rhythm. Intra-cardiac electrophysiological mapping and catheter ablation are often performed without detailed prior knowledge of the mechanism perpetuating AFlut, likely prolonging the procedure time of these invasive interventions. We sought to discriminate the AFlut location [cavotricuspid isthmus-dependent (CTI), peri-mitral, and other left atrium (LA) AFlut classes] with a machine learning-based algorithm using only the non-invasive signals from the 12-lead electrocardiogram (ECG). METHODS AND RESULTS: Hybrid 12-lead ECG dataset of 1769 signals was used (1424 in silico ECGs, and 345 clinical ECGs from 115 patients-three different ECG segments over time were extracted from each patient corresponding to single AFlut cycles). Seventy-seven features were extracted. A decision tree classifier with a hold-out classification approach was trained, validated, and tested on the dataset randomly split after selecting the most informative features. The clinical test set comprised 38 patients (114 clinical ECGs). The classifier yielded 76.3% accuracy on the clinical test set with a sensitivity of 89.7%, 75.0%, and 64.1% and a positive predictive value of 71.4%, 75.0%, and 86.2% for CTI, peri-mitral, and other LA class, respectively. Considering majority vote of the three segments taken from each patient, the CTI class was correctly classified at 92%. CONCLUSION: Our results show that a machine learning classifier relying only on non-invasive signals can potentially identify the location of AFlut mechanisms. This method could aid in planning and tailoring patient-specific AFlut treatments.


Asunto(s)
Aleteo Atrial , Ablación por Catéter , Aleteo Atrial/diagnóstico , Aleteo Atrial/etiología , Aleteo Atrial/cirugía , Electrocardiografía/métodos , Sistema de Conducción Cardíaco , Humanos , Aprendizaje Automático
16.
Eur J Clin Invest ; 51(2): e13428, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-33043453

RESUMEN

BACKGROUND: The coronavirus disease 2019 (COVID-19) pandemic has affected millions of people worldwide resulting in significant morbidity and mortality. Arrhythmias are prevalent and reportedly, the second most common complication. Several mechanistic pathways are proposed to explain the pro-arrhythmic effects of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection. A number of treatment approaches have been trialled, each with its inherent unique challenges. This rapid systematic review aimed to examine the current incidence and available treatment of arrhythmias in COVID-19, as well as barriers to implementation. METHODS: Our search of scientific databases identified relevant published studies from 1 January 2000 until 1 June 2020. We also searched Google Scholar for grey literature. We identified 1729 publications of which 1704 were excluded. RESULTS: The incidence and nature of arrhythmias in the setting of COVID-19 were poorly documented across studies. The cumulative incidence of arrhythmia across studies of hospitalised patients was 6.9%. Drug-induced long QT syndrome secondary to antimalarial and antimicrobial therapy was a significant contributor to arrhythmia formation, with an incidence of 14.15%. Torsades de pointes (TdP) and sudden cardiac death (SCD) were reported. Treatment strategies aim to minimise this through risk stratification and regular monitoring of corrected QT interval (QTc). CONCLUSION: Patients with SARS-CoV-2 are at an increased risk of arrhythmias. Drug therapy is pro-arrhythmogenic and may result in TdP and SCD in these patients. Risk assessment and regular QTc monitoring are imperative for safety during the treatment course. Further studies are needed to guide future decision-making.


Asunto(s)
Arritmias Cardíacas/etiología , COVID-19/complicaciones , Síndrome de QT Prolongado/inducido químicamente , Antiarrítmicos/uso terapéutico , Antibacterianos/efectos adversos , Antimaláricos/efectos adversos , Arritmias Cardíacas/epidemiología , Arritmias Cardíacas/terapia , Fibrilación Atrial/epidemiología , Fibrilación Atrial/etiología , Fibrilación Atrial/terapia , Aleteo Atrial/epidemiología , Aleteo Atrial/etiología , Aleteo Atrial/terapia , Azitromicina/efectos adversos , Bradicardia/epidemiología , Bradicardia/etiología , Bradicardia/terapia , Estimulación Cardíaca Artificial/métodos , Muerte Súbita Cardíaca/epidemiología , Muerte Súbita Cardíaca/etiología , Cardioversión Eléctrica/métodos , Hospitalización , Humanos , Hidroxicloroquina/efectos adversos , Incidencia , Síndrome de QT Prolongado/epidemiología , Síndrome de QT Prolongado/terapia , SARS-CoV-2 , Taquicardia Ventricular/epidemiología , Taquicardia Ventricular/etiología , Taquicardia Ventricular/terapia , Torsades de Pointes/epidemiología , Torsades de Pointes/etiología , Torsades de Pointes/terapia , Fibrilación Ventricular/epidemiología , Fibrilación Ventricular/etiología , Fibrilación Ventricular/terapia , Tratamiento Farmacológico de COVID-19
17.
Clin Transplant ; 35(10): e14429, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-34265128

RESUMEN

BACKGROUND: Atrial flutter is the most common arrhythmia post cardiac transplantation. Observational studies in the non-transplant population have shown prognostic benefit with catheter ablation; however, there are no data in the heart transplant population. OBJECTIVES: This study evaluated the experience of catheter ablation in atrial flutter post cardiac transplantation. METHODS: A retrospective review of experience of late onset atrial flutter at the Freeman Hospital, Newcastle-upon-Tyne, UK, between 1985 and January 2020. RESULTS: Sixty eight of the 722 patients who survived 6 months post cardiac transplantation developed late atrial flutter giving an incidence of 9.4%. Thirty-two patients were managed with ablation with treatment largely determined by time of flutter onset. Kaplan Meier estimates for arrhythmia free survival post first ablation for organized atrial arrhythmias was 83.3% at 1 year. Kaplan-Meier estimates for median survival post onset of atrial arrhythmias treated with ablation was 11.34 years (95% CI 8.00-14.57), compared to 5.79 years in patients managed medically (95%CI 2.26-9.32) (P = .026). CONCLUSIONS: Atrial flutter is an important late complication of cardiac transplantation. Patients treated with ablation in the modern era had increased survival compared to a historical cohort.


Asunto(s)
Fibrilación Atrial , Aleteo Atrial , Ablación por Catéter , Trasplante de Corazón , Fibrilación Atrial/cirugía , Aleteo Atrial/etiología , Aleteo Atrial/cirugía , Ablación por Catéter/efectos adversos , Trasplante de Corazón/efectos adversos , Humanos , Pronóstico , Estudios Retrospectivos
18.
BMC Cardiovasc Disord ; 21(1): 507, 2021 10 20.
Artículo en Inglés | MEDLINE | ID: mdl-34670505

RESUMEN

OBJECTIVES: Atrial remodeling is the main developmental cause of atrial arrhythmias (AA), which may induce atrial fibrillation, atrial flutter, atrial tachycardia, and frequent premature atrial beats in acute myocardial infarction (AMI) patients. Thrombospondin-1 (TSP-1) has been shown to play an important role in inflammatory and fibrotic processes, but its role in atrial arrhythmias is not well described. The purpose of this study was to investigate the role of TSP-1 in AMI patients with atrial arrhythmias. METHODS: A total of 219 patients with AMI who underwent percutaneous coronary intervention and with no previous arrhythmias were included. TSP-1 were analyzed in plasma samples. Patients were classified into 2 groups, namely, with and without AA during the acute phase of MI. Continuous electrocardiographic monitoring was used for AA diagnosis in hospital. RESULTS: Twenty-four patients developed AA. Patients with AA had higher TSP-1 levels (29.01 ± 25.87 µg/mL vs 18.36 ± 10.89 µg/mL, p < 0.001) than those without AA. AA patients also tended to be elderly (65.25 ± 9.98 years vs 57.47 ± 10.78 years, p < 0.001), had higher Hs-CRP (39.74 ± 43.50 mg/L vs 12.22 ± 19.25 mg/L, p < 0.001) and worse heart function. TSP-1 (OR 1.033; 95% CI 1.003-1.065, p = 0.034), Hs-CRP (OR 1.023; 95% CI 1.006-1.041, p = 0.008), age (OR 1.067; 95% CI 1.004-1.135, p = 0.038) and LVDd (OR 1.142; 95% CI 1.018-1.282, p = 0.024) emerged as independent risk factors for AA in AMI patients. CONCLUSION: TSP-1 is a potential novel indicator of atrial arrhythmias during AMI.


Asunto(s)
Fibrilación Atrial/sangre , Aleteo Atrial/sangre , Complejos Atriales Prematuros/sangre , Infarto del Miocardio/sangre , Taquicardia Supraventricular/sangre , Trombospondina 1/sangre , Adulto , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/etiología , Aleteo Atrial/diagnóstico , Aleteo Atrial/etiología , Complejos Atriales Prematuros/diagnóstico , Complejos Atriales Prematuros/etiología , Remodelación Atrial , Biomarcadores/sangre , Femenino , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/complicaciones , Infarto del Miocardio/diagnóstico , Valor Predictivo de las Pruebas , Medición de Riesgo , Factores de Riesgo , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/etiología , Regulación hacia Arriba , Adulto Joven
19.
BMC Cardiovasc Disord ; 21(1): 592, 2021 12 09.
Artículo en Inglés | MEDLINE | ID: mdl-34886795

RESUMEN

BACKGROUND: COVID-19 and Fontan physiology have each been associated with an elevated risk of venous thromboembolism (VTE), however little is known about the risks and potential consequences of having both. CASE PRESENTATION: A 51 year old male with tricuspid atresia status post Fontan and extracardiac Glenn shunt, atrial flutter, and sinus sick syndrome presented with phlegmasia cerulea dolens (PCD) of the left lower extremity in spite of supratherapeutic INR in the context of symptomatic COVID-10 pneumonia. He was treated with single session, catheter directed mechanical thrombectomy that was well-tolerated. CONCLUSIONS: This report of acute PCD despite therapeutic anticoagulation with a Vitamin K antagonist, managed with emergent mechanical thrombectomy, calls to attention the importance of altered flow dynamics in COVID positive patients with Fontan circulation that may compound these independent risk factors for developing deep venous thrombosis with the potential for even higher morbidity.


Asunto(s)
COVID-19 , Procedimiento de Fontan , Gangrena , Trombolisis Mecánica , Complicaciones Posoperatorias , Tromboflebitis , Atresia Tricúspide , Warfarina/uso terapéutico , Amputación Quirúrgica/métodos , Aleteo Atrial/tratamiento farmacológico , Aleteo Atrial/etiología , COVID-19/sangre , COVID-19/complicaciones , COVID-19/terapia , Procedimiento de Fontan/efectos adversos , Procedimiento de Fontan/métodos , Gangrena/etiología , Gangrena/cirugía , Cardiopatías Congénitas/cirugía , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Extremidad Inferior/irrigación sanguínea , Extremidad Inferior/patología , Extremidad Inferior/cirugía , Masculino , Trombolisis Mecánica/efectos adversos , Trombolisis Mecánica/métodos , Persona de Mediana Edad , Flebografía/métodos , Complicaciones Posoperatorias/diagnóstico , Complicaciones Posoperatorias/fisiopatología , Complicaciones Posoperatorias/cirugía , Síndrome del Seno Enfermo/diagnóstico , Síndrome del Seno Enfermo/etiología , Tromboflebitis/diagnóstico , Tromboflebitis/etiología , Tromboflebitis/cirugía , Tomografía Computarizada por Rayos X/métodos , Resultado del Tratamiento , Atresia Tricúspide/etiología , Atresia Tricúspide/cirugía
20.
Echocardiography ; 38(6): 1084-1088, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-34018636

RESUMEN

We report isolated extramedullary relapse in a 14-year-old boy, sequentially presenting with intestinal and cardiac myeloid sarcoma (MS). Acute myeloblastic leukemia M5 was diagnosed 41 months ago. On the 14th month of the second HSCT, he presented with ileus and underwent surgical treatment. After 2 weeks, arrhythmia, bradycardia, complete heart block, and atrial flutter developed and echocardiography revealed multiple cardiac masses. There was no bone marrow relapse but pathology of the intestinal biopsy showed leukemic infiltration. Patient was successfully treated with a permanent pacemaker and salvage chemotherapy. To the best of our knowledge, this is the first pediatric cardiac MS developed after HSCT.


Asunto(s)
Aleteo Atrial , Bloqueo Atrioventricular , Trasplante de Células Madre Hematopoyéticas , Leucemia Mieloide Aguda , Sarcoma Mieloide , Adolescente , Arritmias Cardíacas , Aleteo Atrial/etiología , Niño , Trasplante de Células Madre Hematopoyéticas/efectos adversos , Humanos , Leucemia Mieloide Aguda/complicaciones , Leucemia Mieloide Aguda/terapia , Masculino , Recurrencia , Sarcoma Mieloide/diagnóstico por imagen , Trasplante Homólogo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA