Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 67
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Pacing Clin Electrophysiol ; 47(2): 185-194, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38010836

RESUMO

BACKGROUND: Despite its clinical benefits, patient compliance to remote monitoring (RM) of cardiac implantable electronic devices (CIEDs) varies and remains under-studied in diverse populations. OBJECTIVE: We sought to evaluate RM compliance, clinical outcomes, and identify demographic and socioeconomic factors affecting RM in a diverse urban population in New York. METHODS: This retrospective cohort study included patients enrolled in CIED RM at Montefiore Medical Center between December 2017 and May 2022. RM compliance was defined as the percentage of days compliant to RM transmission divided by the total prescribed days of RM. Patients were censored when they were lost to follow-up or at the time of death. The cohorts were categorized into low (≤30%), intermediate (31-69%), and high (≥70%) RM compliance groups. Statistical analyses were conducted accordingly. RESULTS: Among 853 patients, median RM compliance was 55%. Age inversely affected compliance (p < .001), and high compliance was associated with guideline-directed medical therapy (GDMT) usage and implantable cardioverter defibrillator (ICD)/cardiac resynchronization defibrillator (CRTD) devices. The low-compliance group had a higher mortality rate and fewer regular clinic visits (p < .001) than high-compliance group. Socioeconomic factors did not significantly impact compliance, while Asians showed higher compliance compared with Whites (OR 3.67; 95% CI 1.08-12.43; p = .04). Technical issues were the main reason for non-compliance. CONCLUSION: We observed suboptimal compliance to RM, which occurred most frequently in older patients. Clinic visit compliance, optimal medical therapy, and lower mortality were associated with higher compliance, whereas insufficient understanding of RM usage was the chief barrier to compliance.


Assuntos
Desfibriladores Implantáveis , Tecnologia de Sensoriamento Remoto , Humanos , Idoso , Estudos Retrospectivos , Dispositivos de Terapia de Ressincronização Cardíaca , Demografia
2.
Europace ; 25(1): 175-184, 2023 02 08.
Artigo em Inglês | MEDLINE | ID: mdl-36196043

RESUMO

AIMS: The aim of this study is to provide guidance for the clinical interpretation of electrocardiograms (ECGs) in prone position and to establish the electroanatomic explanations for the possible differences to supine position ECGs that may be observed. Additionally, to determine if prone back ECG can be used as an alternative to standard ECG in patients who may benefit from prone position. METHODS AND RESULTS: The ECG in supine (standard ECG), prone back (precordial leads placed on the patient's back), and prone anterior position (precordial leads placed in the standard position with the subjects in prone position) were prospectively examined on 85 subjects. Comparisons of ECG parameters between these positions were performed. Computed tomography (CT) scans were performed in both positions to determine possible electroanatomic aetiologies for prone-associated ECG changes. There were significant differences in QRS amplitude in Leads V1-V5 between supine and prone positions. Q waves were more frequently observed in prone back position vs. supine position (V1: 74.1 vs. 10.6%, P < 0.0001; V2: 23.5 vs. 0%, P < 0.0001, respectively). Flat and inverted T waves were more common in prone back leads (V1: 98 vs. 66%, P < 0.0001; V2: 96 vs. 8%, P < 0.0001; V3: 45 vs. 7%, P < 0.0001). The 3D-CT reconstructions measurements corroborated the significant inverse correlation between QRS amplitude and the distance from the centre of the heart to the estimated lead positions. CONCLUSION: In prone back position ECG, low QRS amplitude should not be misinterpreted as low voltage conditions, neither should Q waves and abnormal T waves are considered anteroseptal myocardial infarction. These changes can be explained by an increased impedance (due to interposing lung tissue) and by the increased distance between the electrodes to the centre of the heart.


Assuntos
Eletrocardiografia , Posicionamento do Paciente , Humanos , Decúbito Ventral , Estudos Prospectivos , Eletrocardiografia/métodos , Coração
3.
J Cardiovasc Electrophysiol ; 31(11): 2803-2811, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32852868

RESUMO

INTRODUCTION: Coronavirus disease 2019 (COVID-19) is a worldwide pandemic, and cardiovascular complications and arrhythmias in these patients are common. Cardiac monitoring is recommended for at risk patients; however, the availability of telemetry capable hospital beds is limited. We sought to evaluate a patch-based mobile telemetry system for inpatient cardiac monitoring during the pandemic. METHODS: A prospective cohort study was performed of inpatients hospitalized during the pandemic who had mobile telemetry devices placed; patients were studied up until the time of discharge or death. The primary outcome was a composite of management changes based on data obtained from the system and detection of new arrhythmias. Other clinical outcomes and performance characteristics of the mobile telemetry system were studied. RESULTS: Eighty-two patients underwent mobile telemetry device placement, of which 31 (37.8%) met the primary outcome, which consisted of 24 (29.3%) with new arrhythmias detected and 18 (22.2%) with management changes. Twenty-one patients (25.6%) died during the study, but none from primary arrhythmias. In analyses, age and heart failure were associated with the primary outcome. Monitoring occurred for an average of 5.3 ± 3.4 days, with 432 total patient-days of monitoring performed; of these, QT-interval measurements were feasible in 400 (92.6%). CONCLUSION: A mobile telemetry system was successfully implemented for inpatient use during the COVID-19 pandemic and was shown to be useful to inform patient management, detect occult arrhythmias, and monitor the QT-interval. Patients with advanced age and structural heart disease may be more likely to benefit from this system.


Assuntos
Arritmias Cardíacas/diagnóstico , COVID-19/complicações , Eletrocardiografia/instrumentação , Frequência Cardíaca , Pacientes Internados , Telemetria/instrumentação , Potenciais de Ação , Idoso , Idoso de 80 Anos ou mais , Arritmias Cardíacas/etiologia , Arritmias Cardíacas/mortalidade , Arritmias Cardíacas/terapia , COVID-19/diagnóstico , COVID-19/mortalidade , COVID-19/terapia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Fatores de Tempo , Resultado do Tratamento
4.
Pacing Clin Electrophysiol ; 43(1): 30-36, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31693197

RESUMO

BACKGROUND: Early repolarization (ER) pattern on ECG is associated with an increased mortality in Caucasians. This study analyzed the association between ER pattern and all-cause mortality in a population of multiple ethnicities. METHODS: A total of 20 000 individuals were randomly selected and their ECGs were analyzed for ER pattern using the 2015 consensus: end-QRS notching or slurring with a J-point (Jp) ≥0.1 mV in contiguous inferior or lateral leads. Exclusion criteria were age <18, QRS duration of ≥120 ms, and acute myocardial infarction. Kaplan-Meier survival curves were used to assess crude survival, and multivariable logistic regression models were used to determine predictors of all-cause mortality. RESULTS: A total of 17 901 patients with a mean age of 53 met inclusion criteria. Individuals were 62% female, 14% White, 37% Black, 40% Hispanic, and 9% other. Median follow-up time was 6.4 years. ER pattern was noted in 995 (5.6%) patients. Jp ≥2 mm was noted in 282 (1.6%) patients. In those with ER pattern and Jp ≥1 mm, there was no difference in mortality when compared to individuals without Jp elevation (odds ratio [OR]: 0.962, 95% confidence of interval [CI]: 0.819-1.131). Patients with Jp ≥2 mm had a significantly increased all-cause mortality (OR: 1.333, 95% CI: 1.009-1.742). This increased mortality was also significant in Hispanic patients with Jp ≥2 mm (OR: 1.584, 95% CI: 1.003-2.502). CONCLUSION: ER pattern with Jp ≥2 mm is associated with increased mortality in a multiethnic population, apparently driven by an increased risk in Hispanics.


Assuntos
Arritmias Cardíacas/etnologia , Arritmias Cardíacas/fisiopatologia , Sistema de Condução Cardíaco/fisiopatologia , Hispânico ou Latino/estatística & dados numéricos , Negro ou Afro-Americano/estatística & dados numéricos , Arritmias Cardíacas/mortalidade , Eletrocardiografia , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Retrospectivos , Fatores de Risco , População Branca/estatística & dados numéricos
5.
J Electrocardiol ; 62: 211-215, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32992259

RESUMO

BACKGROUND: Wellens' sign is considered to be an ominous sign indicative of underlying significant proximal left anterior descending artery stenosis. We sought to identify the prevalence of the Wellens' pattern in a large ethnically diverse urban population and assess its association with the presence and extent of coronary artery disease. METHODS: We utilized the MUSE ECG database of Montefiore Medical Center, an academic tertiary health care system, to identify ECGs from 2012 to 2019 exhibiting a Wellens' pattern. From a dataset of 1.76 million tracings, six screening diagnosis codes were selected to approximate the Wellens' pattern. These codes were used to generate a cohort of ECGs for manual review by a board certified cardiologist to determine if a Wellens' pattern was present. RESULTS: Of 1,756,742 ECGs performed on 433,218 patients from 2012 to 2019; after initial screening 2186 ECGs were identified for manual review. Of these, 448 (0.1%) patients were confirmed to have a Wellens' pattern. 229 patients underwent cardiac catheterization, while 219 patients were managed medically. No statistical difference was seen in the occurrence of Wellens' Type A and B pattern across the ethnic groups after multivariate analysis. Women were more likely to have Type B Wellens' compared to men (OR 2.40 (1.58, 3.62) P < 0.0001). 80 (35%) patients had single vessel LAD disease of which 22 (10%) had proximal, 40 (17%) had mid, 4 (1%) had distal stenosis, while diffuse LAD disease was seen in 14 (6%) patients. Two vessel disease was seen in 46 (20%) patients with a Wellens' pattern, and triple vessel disease was seen in 23 (10%) patients. Of note, 71 (31%) patients had either normal or nonobstructive coronary disease despite exhibiting a Wellens' pattern ECG. CONCLUSION: Wellens' sign is a rare electrocardiographic pattern which when seen in a patient with an appropriate clinical presentation, suggests but is not definitive for the presence of significant coronary disease, often but not exclusively in an LAD distribution. We found no statistical difference in the occurrence of Wellens' sign among different racial/ethnic groups. Patients with a Wellens' pattern may have critical lesions at a variety of LAD sites as well as in multiple vessels. As such, the interventionalist needs to be prepared for these uncertainties at the time of cardiac catheterization.


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/epidemiologia , Eletrocardiografia , Feminino , Humanos , Masculino , Prevalência , Síndrome , População Urbana
6.
Pacing Clin Electrophysiol ; 41(10): 1298-1306, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-30109698

RESUMO

PURPOSE: Survey the usage and application protocol of antimicrobial agent pocket irrigation for cardiovascular implantable electronic device (CIED) infection prophylaxis. BACKGROUND: Local antibiotic usage for CIED infection prophylaxis, in particular pocket irrigation, is a well-known strategy but with little data on its clinical effectiveness. METHODS: An anonymous voluntary online survey was sent to a total of 2,092 arrhythmia-oriented cardiologists in 51 countries (1,490 from the United States). RESULTS: There were 487 responses (response rate 23.3%: U.S. 28.2%, outside of the U.S. 11.1%). Eighty-seven percent of respondents use intraoperative antimicrobial agent pocket irrigation and/or an antimicrobial eluting pouch to reduce CIED infection. Fifty-four percent of respondents believe that it is effective to use an antimicrobial agent pocket irrigation to reduce CIED infection; 33% of respondents are uncertain; a few consider this strategy ineffective (13%) or offered no opinion. Significant differences exist in the practice patterns and beliefs between the U.S. and non-U.S. countries (P < 0.05). Ninety-eight percent of respondents report using the same pocket irrigation protocol for permanent pacemaker versus implantable cardioverter defibrillator. Bacitracin (48%), vancomycin (39%), and a cephalosporin (29%) are the most commonly chosen antibiotics. A majority of the respondents are unaware of the cost of using antimicrobial agent pocket irrigation (69%) and neither are they concerned (67%). CONCLUSION: This international survey suggests that, while there are little clinical data to support or discourage such practice, the usage of antimicrobial agent pocket irrigation for CIED infection prophylaxis is widely used in current practice.


Assuntos
Anti-Infecciosos/administração & dosagem , Antibioticoprofilaxia/métodos , Desfibriladores Implantáveis , Marca-Passo Artificial , Padrões de Prática Médica/estatística & dados numéricos , Infecções Relacionadas à Prótese/prevenção & controle , Irrigação Terapêutica/métodos , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Inquéritos e Questionários
7.
Emerg Med J ; 35(2): 96-102, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28821492

RESUMO

OBJECTIVE: To examine the ability of the low-frequency/high-frequency (LF/HF) ratio of heart rate variability (HRV) analysis to identify patients with sepsis at risk of early deterioration. METHODS: This is a prospective observational cohort study of patients with sepsis presenting to the Montefiore Medical Center ED from December 2014 through September 2015. On presentation, a single ECG Holter recording was obtained and analysed to obtain the LF/HF ratio of HRV. Initial Sequential Organ Failure Assessment (SOFA) scores were computed. Patients were followed for 72 hours to identify those with early deterioration. RESULTS: 466 patients presenting to the ED with sepsis were analysed. Thirty-two (7%) reached at least one endpoint within 72 hours. An LF/HF ratio <1 had a sensitivity and specificity of 34% (95% CI (19% to 53%)) and 82% (95% CI (78% to 85%)), respectively, with positive and negative likelihood ratios of 1.9 (95% CI (1.1 to 3.2)) and 0.8 (95% CI (0.6 to 1.0)). An initial SOFA score ≥3 had a sensitivity and specificity of 38% (95% CI (22% to 56%)) and 92% (95% CI (89% to 95%)), with positive and negative likelihood ratios of 4.9 (95% CI (2.8 to 8.6)) and 0.7 (95% CI (0.5 to 0.9)). The composite measure of HRV+SOFA had improved sensitivity (56%, 95% CI (38% to 73%)) but at the expense of specificity (77%, 95% CI (72% to 80%)), with positive and negative likelihood ratios of 2.4 (95% CI (1.7 to 3.4)) and 0.6 (95% CI (0.4 to 0.9)). Receiver operating characteristic analysis did not identify a superior alternate threshold for the LF/HF ratio. Kaplan-Meier survival functions differed significantly (p=0.02) between low (<1) and high (≥1) LF/HF groups. CONCLUSIONS: While we found a statistically significant relationship between HRV, SOFA and HRV+SOFA, and early deterioration, none reliably functioned as a clinical predictive tool. More complex multivariable models will likely be required to construct models with clinical utility.


Assuntos
Deterioração Clínica , Determinação da Frequência Cardíaca/métodos , Ondas de Rádio , Sepse/diagnóstico , Adulto , Idoso , Estudos de Coortes , Eletrocardiografia/métodos , Serviço Hospitalar de Emergência/organização & administração , Feminino , Frequência Cardíaca/fisiologia , Determinação da Frequência Cardíaca/normas , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sensibilidade e Especificidade , Sepse/fisiopatologia
9.
Pacing Clin Electrophysiol ; 38(12): 1396-404, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26260160

RESUMO

BACKGROUND: Early repolarization (ER), once thought to be a benign finding on electrocardiograph (ECG), has recently been associated with an increased risk of sudden cardiac death. As there are limited data in the Hispanic population, we investigated possible associations between automated ECG ER readings and overall mortality, using the classic definition involving J-point elevation with ST segment elevation. METHODS: An ECG and electronic medical record (EMR) database from a regional medical center was interrogated. Inclusion criteria included Hispanic ethnicity and age over 18 from 2000 to 2011. A Cox model assessed the outcome of death. Varying morphological characteristics of ER were analyzed for high-risk features. RESULTS: There were n = 33,944 Hispanics of who n = 532 (1.6%) had ER with a mean follow-up period of 5.29 years. After adjustment for demographic, clinical, lifestyle, and laboratory variables, ER was not significantly related to all-cause mortality (hazard ratio [HR]: 1.18, 95% confidence interval [CI]: 0.90-1.54, P = 0.23). However, mortality risk of ER varied by gender and age (P interaction = 0.007). The risk of ER for mortality was highest for females (HR: 2.01, CI: 1.39-3.10, P = 0.001), with the highest overall risk for women over the age of 75 (HR: 2.09, CI: 1.12-3.92, P = 0.021) compared to women under age 75 (HR: 1.72, CI: 0.95-3.11, P = 0.075). CONCLUSIONS: ER is not associated with an increased risk of death in the overall Hispanic population. However, our analysis suggests a higher risk of overall mortality in the elderly Hispanic female population with ER.


Assuntos
Hispânico ou Latino/estatística & dados numéricos , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/etnologia , Infarto do Miocárdio/mortalidade , Distribuição por Idade , Morte Súbita Cardíaca/etnologia , Feminino , Humanos , Incidência , Masculino , New York/epidemiologia , Prognóstico , Reprodutibilidade dos Testes , Medição de Risco , Sensibilidade e Especificidade , Distribuição por Sexo , Taxa de Sobrevida
10.
J Electrocardiol ; 48(4): 703-9, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26025203

RESUMO

BACKGROUND: PR interval prolongation on electrocardiogram (ECG) increases the risk of atrial fibrillation (AF). Non-Hispanic Whites are at higher risk of AF compared to African Americans and Hispanics. However, it remains unknown if prolongation of the PR interval for the development of AF varies by race/ethnicity. Therefore, we determined whether race affects the PR interval length's ability to predict AF and if the commonly used criterion of 200 ms in AF prediction models can continue to be used for non-White cohorts. METHODS: This is a retrospective epidemiological study of consecutive inpatient and outpatients. An ECG database was initially interrogated. Patients were included if their initial ECG demonstrated sinus rhythm and had two or more electrocardiograms and declared a race and/or ethnicity as non-Hispanic White, African American or Hispanic. Development of AF was stratified by race/ethnicity along varying PR intervals. Cox models controlled for age, gender, race/ethnicity, systolic blood pressure, BMI, QRS, QTc, heart rate, murmur, treatment for hypertension, heart failure and use of AV nodal blocking agents to assess PR interval's predictive ability for development of AF. RESULTS: 50,870 patients met inclusion criteria of which 5,199 developed AF over 3.72 mean years of follow-up. When the PR interval was separated by quantile, prolongation of the PR interval to predict AF first became significant in Hispanic and African Americans at the 92.5th quantile of 196-201 ms (HR: 1.42, 95% CI: 1.09-1.86, p=0.01; HR: 1.32, 95% CI: 1.07-1.64, p=0.01, respectively) then in non-Hispanic Whites at the 95th quantile at 203-212 ms (HR: 1.24, 95% CI: 1.24-1.53, p=0.04). For those with a PR interval above 200 ms, African Americans had a lower risk than non-Hispanic Whites to develop AF (HR: 0.80, 95% CI: 0.64-0.95, p=0.012), however, no significant difference was demonstrated in Hispanics. CONCLUSIONS: This is the first study to validate a PR interval value of 200 ms as a criterion in African Americans and Hispanics for the development of AF. However, a value of 200 ms may be less sensitive as a predictive measure for the development of AF in African Americans compared to non-Hispanic Whites.


Assuntos
Fibrilação Atrial/etnologia , Fibrilação Atrial/mortalidade , Negro ou Afro-Americano/estatística & dados numéricos , Eletrocardiografia/estatística & dados numéricos , Hispânico ou Latino/estatística & dados numéricos , População Branca/estatística & dados numéricos , Idoso , Diagnóstico por Computador/métodos , Eletrocardiografia/métodos , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , New York/etnologia , Prevalência , Reprodutibilidade dos Testes , Medição de Risco/métodos , Sensibilidade e Especificidade , Taxa de Sobrevida
11.
Am J Emerg Med ; 32(9): 1113-6, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25053264

RESUMO

Syncope is a frequent presenting complaint in the emergency department and is associated with significant medical costs. We examined the utility of inpatient evaluation of syncope for patients in whom a diagnosis was not established in the emergency department. We retrospectively reviewed consecutive patients presenting with syncope to an urban tertiary care medical center. A diagnosis was not established after initial evaluation in the emergency department in 171 of 230 patients admitted. Inhospital evaluation led to a diagnosis in 26 patients. Acute intervention was required in 2 patients. Our observations suggest that an inpatient evaluation of syncope for patients in whom a diagnosis is not made on initial evaluation is of low yield, and outpatient follow-up may be safe.


Assuntos
Hospitalização , Síncope/etiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Comorbidade , Serviço Hospitalar de Emergência/estatística & dados numéricos , Feminino , Hospitalização/estatística & dados numéricos , Hospitais Urbanos/estatística & dados numéricos , Humanos , Tempo de Internação/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Avaliação de Processos e Resultados em Cuidados de Saúde , Estudos Retrospectivos , Síncope/diagnóstico , Síncope/epidemiologia , Centros de Atenção Terciária/estatística & dados numéricos , Adulto Jovem
12.
Heart Rhythm ; 2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38641221

RESUMO

BACKGROUND: Premature ventricular contraction (PVC) burden is a risk factor for heart failure and cardiovascular death in patients with structural heart disease. Long-term electrocardiographic monitoring can have a significant impact on PVC burden evaluation by further defining PVC distribution patterns. OBJECTIVE: This study aimed to ascertain the optimal duration of electrocardiographic monitoring to characterize PVC burden and to understand clinical characteristics associated with frequent PVCs and nonsustained ventricular tachycardia in a large US cohort. METHODS: Commercial data (iRhythm's Zio patch) from June 2011 to April 2022 were analyzed. Inclusion criteria were age >18 years, PVC burden ≥5%, and wear period ≥13 days. PVC burden cutoffs were determined on the basis of AHA/ACC/HRS guidelines for very frequent PVCs (10,000-20,000 during 24 hours). Patients were assigned to categories by PVC densities: low, <10%; moderate, 10% to <20%; and high, ≥20%. Mean measured error was assessed at baseline and daily until the wear period's end for overall PVC burden and different PVC densities. RESULTS: Analysis of 106,705 patch monitors revealed a study population with mean age of 70.6 ± 14.6 years (33.6% female). PVC burden was higher in male patients and those >65 years of age. PVC burden mean error decreased from 2.9% at 24 hours to 1.3% at 7 days and 0.7% at 10 days. Number of ventricular tachycardia episodes per patient increased with increasing PVC burden (P < .0001). CONCLUSION: Extending ambulatory monitoring beyond 24 hours to 7 days or more improves accuracy of assessing PVC burden. Ventricular tachycardia frequency and duration vary by initial PVC density, highlighting the need for prolonged cardiac monitoring.

13.
Am J Cardiol ; 202: 151-159, 2023 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-37437356

RESUMO

Implantable cardiac monitors are routinely placed for long-term monitoring (LTM) after a period of negative short-term monitoring (STM) to increase atrial fibrillation (AF) detection after a cryptogenic stroke or transient ischemic attack (TIA). Optimizing AF monitoring after a cryptogenic stroke is critical to improve outcomes and reduce costs. We sought to compare the diagnostic yield of STM versus LTM, assess the impact of routine STM on hospitalization length of stay, and perform a financial analysis comparing the current model to a theoretical model wherein patients can proceed directly to LTM. Our retrospective observational cohort study analyzed patients admitted to Montefiore Medical Center between May 2017 and June 2022 with a primary diagnosis of cryptogenic stroke or TIA who underwent Holter device monitoring. Of 396 subjects, STM detected AF in 10 (2.5%) compared with a diagnostic yield of 14.6% for LTM (median time to diagnosis of 76 days). Of the 386 patients with negative STM, 130 (33.7%) received an implantable cardiac monitor while an inpatient, and 256 (66.3%) did not. We calculated a point estimate of 1.67 days delay of discharge attributable to the requirement for STM to precede LTM. Our model showed that the expected cost per patient in the STM-first paradigm is $28,615.33 versus $27,111.24 in the LTM-or-STM paradigm. Considering the relatively lower diagnostic yield of STM and its association with a longer length of stay and higher costs, it may be reasonable to proceed directly to LTM to optimize AF detection after a cryptogenic stroke or TIA.


Assuntos
Fibrilação Atrial , Ataque Isquêmico Transitório , AVC Isquêmico , Acidente Vascular Cerebral , Humanos , Ataque Isquêmico Transitório/diagnóstico , Acidente Vascular Cerebral/complicações , Estudos Retrospectivos , AVC Isquêmico/complicações , Eletrocardiografia Ambulatorial , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico
14.
Am Heart J Plus ; 13: 100084, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35036973

RESUMO

BACKGROUND: Coronavirus infection is the cause of the current world-wide pandemic. Cardiovascular complications occur in 20-30% of patients with COVID-19 infection including myocardial injury and arrhythmias. Current understanding of specific arrhythmia type and frequency is limited. OBJECTIVE: We aimed to analyze arrhythmia type and frequency in patients with COVID infection, identifying arrhythmia patterns over time during hospitalization and post discharge utilizing a patch based mobile cardiac telemetry system. METHODS: A prospective cohort study during the COVID-19 pandemic was performed. We included in our study patients hospitalized with COVID-19 infection who had a patch-based mobile telemetry device placed for cardiac monitoring. RESULTS: Quantitative reports for 59 patients were available for analysis. Arrhythmias were detected in 72.9% of patients and at a consistent frequency throughout the monitoring period in 52.9%-89.5% of patients daily. The majority of arrhythmias were SVT (59.3% of patients) and AF (22.0%). New onset AF was noted in 15.0% of all patients and was significantly associated with older age (OR 1.4 for 5 yrs. difference; 95% CI 1.03-2.13). Of 9 patients who were discharged with continued patch monitoring, 7 (78%) had arrhythmic events during their outpatient monitoring period. CONCLUSION: In COVID-19 patients arrhythmias were observed throughout hospitalization with a consistent daily frequency. Patients continued to exhibit cardiac arrhythmias after hospital discharge of a type and frequency similar to that seen during hospitalization. These findings suggest that the risk of arrhythmia associated with COVID infection remains elevated throughout the hospital course as well as following hospital discharge.

15.
Int J Cardiol ; 364: 35-37, 2022 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-35662560

RESUMO

INTRODUCTION: Despite the technological advances and increasing operator experience, the rate of permanent pacemaker implantation (PPI) after transcatheter aortic valve replacement (TAVR) has not decreased over time. With a continuous downward trend in post-TAVR length of stay, prolonged home-monitoring may have a key role in detecting potentially serious conduction abnormalities after TAVR discharge. METHODS: In this study, the ZioPatch-AT monitor was used to detect conduction abnormalities after TAVR discharge. The cardiac monitoring device was systematically provided to all patients having pre-existing right bundle branch block or developing intra-/peri-procedural conduction disturbances, in the absence of guideline indication for PPI at discharge. RESULTS: From a total of 75 patients at high-risk of conduction disturbances, 8 (11%) of them underwent PPI and most of them (6/8) were detected before symptoms' occurrence. Paired analysis between baseline and discharge electrocardiograms detected a significant widening of the QRS in all patients; on the contrary, PR length was significantly increased only in the group experiencing HAVB after discharge (p < 0.01). CONCLUSIONS: In an early post-TAVR discharge era, 30-day outpatient cardiac rhythm monitoring is potentially a safe solution to allow timely recognition of new conduction disturbances requiring PPI.


Assuntos
Estenose da Valva Aórtica , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Doença do Sistema de Condução Cardíaco/diagnóstico , Doença do Sistema de Condução Cardíaco/etiologia , Doença do Sistema de Condução Cardíaco/terapia , Estimulação Cardíaca Artificial , Estudos de Viabilidade , Humanos , Marca-Passo Artificial/efeitos adversos , Alta do Paciente , Fatores de Risco , Telemetria , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
16.
Am J Cardiol ; 144: 77-82, 2021 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-33383004

RESUMO

Application of artificial intelligence techniques in medicine has rapidly expanded in recent years. Two algorithms for identification of cardiac implantable electronic devices using chest radiography were recently developed: The PacemakerID algorithm, available as a mobile phone application (PIDa) and a web platform (PIDw) and The Pacemaker Identification with Neural Networks (PPMnn), available via web platform. In this study, we assessed the relative accuracy of these algorithms. The machine learning algorithms (PIDa, PIDw, PPMnn) were used to predict device manufacturer using chest X-rays for patients with implanted devices. Each prediction was considered correct if predicted certainty was >75%. For comparative purposes, accuracy of each prediction was compared to the result using the CARDIA-X algorithm. 500 X-rays were included from a convenience sample. Raw accuracy was PIDa 89%, PIDw 73%, PPMnn 71% and CARDIA-X 85%. In conclusion, machine learning algorithms for identification of cardiac devices are accurate at determining device manufacturer, have capacity for improved accuracy with additional training sets and can utilize simple user interfaces. These algorithms have clinical utility in limiting potential infectious exposures and facilitate rapid identification of devices as needed for device reprogramming.


Assuntos
Desfibriladores Implantáveis , Aprendizado de Máquina , Marca-Passo Artificial , Radiografia Torácica , Algoritmos , Humanos , Interpretação de Imagem Assistida por Computador , Redes Neurais de Computação
17.
ESC Heart Fail ; 8(2): 1571-1581, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33619893

RESUMO

AIMS: This study aims to characterize the range of implantable device-based sensor values including heart sounds, markers of ventilation, thoracic impedance, activity, and heart rate for patients with heart failure (HF) when patients were deemed to be in clinically stable periods against the time course of acute decompensation and recovery from HF events. METHODS AND RESULTS: The MultiSENSE trial followed 900 patients implanted with a COGNIS CRT-D for up to 1 year. Chronic, ambulatory diagnostic sensor data were collected and evaluated during clinically stable periods (CSP: unchanged NYHA classification, no adverse events, and weight change ≤2.27 kg), and in the timeframe leading up to and following HF events (HF admissions or unscheduled visits with intravenous HF treatment). Physiologic sensor data from 1667 CSPs occurring in 676 patients were compared with those data leading up to and following 192 HF events in 106 patients. Overall, the mean age was 66.6 years, and the population were predominantly male (73%). Patients were primarily in NYHA II (67%), with a mean LVEF of 29.6% and median NT-proBNP of 754.5 pg/mL. Sensor values during CSP were poorer in patients who had HF events during the study period than those without HF events, including first heart sound (S1: 2.18 ± 0.84 mG vs. 2.62 ± 0.95 mG, P = 0.002), third heart sound (S3: 1.13 ± 0.36 mG vs. 0.91 ± 0.30 mG, P < 0.001), thoracic impedance (45.66 ± 8.78 Ohm vs. 50.33 ± 8.43 Ohm, P < 0.001), respiratory rate (19.09 ± 3.10 br/min vs. 17.66 ± 2.39 br/min, P = 0.002), night time heart rate (73.39 ± 8.36 b.p.m. vs. 69.56 ± 8.09 b.p.m., P = 0.001), patient activity (1.69 ± 1.84 h vs. 2.56 ± 2.20 h, P = 0.006), and HeartLogic index (11.07 ± 12.14 vs. 5.31 ± 5.13, P = 0.001). Sensor parameters measured worsening status leading up to HF events with recovery of values following treatment. CONCLUSIONS: Device-based physiologic sensors not only revealed progressive worsening leading up to HF events but also differentiated patients at increased risk of HF events when presumed to be clinically stable.


Assuntos
Insuficiência Cardíaca , Idoso , Insuficiência Cardíaca/diagnóstico , Frequência Cardíaca , Hospitalização , Humanos , Masculino
18.
Pacing Clin Electrophysiol ; 33(8): 939-44, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20487338

RESUMO

BACKGROUND: Atrioventricular (AV) node ablation with implantation of a permanent pacemaker is an established mode of therapy in the treatment of atrial fibrillation. However, concern exists regarding subsequent dependency on an entirely paced rhythm and the possible sequela of unheralded pacemaker failure. Data regarding escape rhythm lability, an important feature of pacemaker dependency, are limited. AIMS AND METHODS: The purpose of this study was twofold: (1) to determine the characteristics of escape rhythms at predefined serial time intervals following AV node ablation and pacemaker implantation, and (2) to identify risk factors predictive of unstable escape rhythms. Patients undergoing AV node ablation and pacemaker implantation were assessed for the presence or absence of an escape rhythm during pacemaker interrogation at five predetermined serial time points. Baseline demographics and comorbid conditions were evaluated as potential predictors of those with labile escape rhythms. RESULTS: Seventy-nine percent of the 96 patients studied had an underlying escape rhythm (> or =30 beats per minute) immediately postablation. Although the percentage of patients with an escape rhythm increased at each follow-up interval, the number of patients who consistently demonstrated an escape rhythm declined with each follow-up, with 28% of patients lacking an escape rhythm at some time point, i.e., labile escape rhythm. There were no significant predictors of a labile escape rhythm. CONCLUSION: Among patients who have undergone AV node ablation and pacemaker implantation, 72% have a stable escape rhythm over time, but others are at risk for pacemaker dependency, as predicted by an underlying absent or labile escape rhythm.


Assuntos
Fibrilação Atrial/cirurgia , Nó Atrioventricular/cirurgia , Ablação por Cateter , Frequência Cardíaca , Adulto , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/terapia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Marca-Passo Artificial , Fatores de Risco
19.
Heart Rhythm ; 17(12): 2119-2125, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32679267

RESUMO

BACKGROUND: Premature ventricular contractions (VPC) have hour-to-hour and day-to-day variation. High VPC burden correlates with cardiomyopathy. OBJECTIVE: To determine the optimal duration for ambulatory electrocardiogram monitoring for accurate assessment of VPC burden. METHODS: Our group performed a retrospective analysis on patch monitors used for any indication with overall VPC burden ≥5.0% between February 1, 2016, and February 1, 2020. We generated cumulative daily VPC averages for each day of wear and performed linear regression analysis between each cumulative daily average and overall burden. Patients were divided into groups based on low or high VPC frequency, and the analysis was repeated. Split-sample validation was used to internally validate the overall prediction model. RESULTS: A total of 116 patches representing 107 patients (mean age: 64.5; female: 48%) were analyzed. Mean overall VPC burden was 13.4% ± 7.5% (range: 5.0%-42.0%). Day 1 R2 was 60%, P < .001, and continued to increase to R2 88%, P < .001 at day 14. Median percent and absolute error decreased from 22.70% (interquartile range [IQR]: 9.73-34.39) and 2.58% (IQR: 1.24-4.59) at day 1 to 5.62% (IQR: 2.82-8.39) and 0.55% (IQR: 0.28-1.05) at day 14. Patients with higher overall VPC frequencies achieved a more rapid rise in R2 relative to those with lower frequencies. Split-sample validation supported the internal validity of our linear regression prediction model. CONCLUSION: Mobile telemetry for a period of ∼7 days accurately reflects overall VPC burden. Measurement of VPC burden for only 24-48 hours may not accurately reflect total burden. Monitoring for 2 weeks or longer adds little additional VPC information.


Assuntos
Eletrocardiografia Ambulatorial/métodos , Frequência Cardíaca/fisiologia , Ventrículos do Coração/fisiopatologia , Contração Miocárdica/fisiologia , Função Ventricular Esquerda/fisiologia , Complexos Ventriculares Prematuros/fisiopatologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Tempo , Complexos Ventriculares Prematuros/diagnóstico
20.
J Interv Card Electrophysiol ; 59(2): 337-345, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32654098

RESUMO

PURPOSE: Hydroxychloroquine, chloroquine, and azithromycin have been used for treatment of COVID-19, but may cause QT prolongation. Minority populations are disproportionately impacted by COVID-19. This study evaluates the risk of QT prolongation and subsequent outcomes after administration of these medications in largely underrepresented minority COVID-19 patients. METHODS: We conducted an observational study on hospitalized COVID-19 patients in the Montefiore Health System (Bronx, NY). We examined electrocardiograms (ECG) pre/post-medication initiation to evaluate QTc, HR, QRS duration, and presence of other arrhythmias. RESULTS: One hundred five patients (mean age 67 years; 44.8% F) were analyzed. The median time from the first dose of any treatment to post-medication ECG was 2 days (IQR: 1-3). QTc in men increased from baseline (440 vs 455 ms, p < 0.001), as well as in women (438 vs 463 ms, p < 0.001). The proportion of patients with QT prolongation increased significantly (14.3% vs 34.3%, p < 0.001) even when adjusted for electrolyte abnormalities. The number of patients whose QTc > 500 ms was significantly increased after treatment (16.2% vs. 4.8%, p < 0.01). Patients with either QTc > 500 ms or an increase of 60 ms had a higher frequency of death (47.6% vs. 22.6%, p = 0.02) with an odds ratio of 3.1 (95% CI: 1.1-8.7). Adjusting for race/ethnicity yielded no significant associations. CONCLUSIONS: Hydroxychloroquine, chloroquine, and/or azithromycin were associated with QTc prolongation but did not result in fatal arrhythmias. Our findings suggest that any harm is unlikely to outweigh potential benefits of treatment. Careful risk-benefit analyses for individual patients should guide the use of these medications. Randomized control trials are necessary to evaluate their efficacies.


Assuntos
Antimaláricos/efeitos adversos , Azitromicina/efeitos adversos , Infecções por Coronavirus/tratamento farmacológico , Eletrocardiografia/métodos , Síndrome do QT Longo/induzido quimicamente , Pneumonia Viral/tratamento farmacológico , Distribuição por Idade , Idoso , Idoso de 80 Anos ou mais , Antimaláricos/administração & dosagem , Azitromicina/administração & dosagem , COVID-19 , Cloroquina/administração & dosagem , Cloroquina/efeitos adversos , Infecções por Coronavirus/diagnóstico , Infecções por Coronavirus/epidemiologia , Feminino , Seguimentos , Hospitalização/estatística & dados numéricos , Humanos , Hidroxicloroquina/administração & dosagem , Hidroxicloroquina/efeitos adversos , Incidência , Síndrome do QT Longo/diagnóstico por imagem , Síndrome do QT Longo/tratamento farmacológico , Síndrome do QT Longo/epidemiologia , Masculino , Pessoa de Meia-Idade , Pandemias/prevenção & controle , Pandemias/estatística & dados numéricos , Pneumonia Viral/diagnóstico , Pneumonia Viral/epidemiologia , Medição de Risco , Distribuição por Sexo , População Urbana
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA