Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Bases de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Anal Chem ; 81(19): 8041-7, 2009 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-19711965

RESUMO

We describe a novel method of generating monodisperse subfemtoliter aqueous droplets on demand by means of piezoelectric injection. Droplets with volumes down to 200 aL are generated by this technique. The droplets are injected into a low refractive index perfluorocarbon so that they can be optically trapped. We demonstrate the use of optical tweezers to manipulate and mix droplets. For example, using optical tweezers we bring two droplets, one containing a calcium sensitive dye and the other calcium chloride, into contact. The droplets coalesce with a resulting reaction time of about 1 ms. The monodispersity, manipulability, repeatability, small size, and fast mixing afforded by this system offer many opportunities for nanochemistry and observation of chemical reactions on a molecule-by-molecule basis.

2.
PLoS One ; 5(12): e14359, 2010 Dec 16.
Artigo em Inglês | MEDLINE | ID: mdl-21179558

RESUMO

BACKGROUND: Mitochondrial DNA (mtDNA) genome mutations can lead to energy and respiratory-related disorders like myoclonic epilepsy with ragged red fiber disease (MERRF), mitochondrial myopathy, encephalopathy, lactic acidosis and stroke (MELAS) syndrome, and Leber's hereditary optic neuropathy (LHON). It is not well understood what effect the distribution of mutated mtDNA throughout the mitochondrial matrix has on the development of mitochondrial-based disorders. Insight into this complex sub-cellular heterogeneity may further our understanding of the development of mitochondria-related diseases. METHODOLOGY: This work describes a method for isolating individual mitochondria from single cells and performing molecular analysis on that single mitochondrion's DNA. An optical tweezer extracts a single mitochondrion from a lysed human HL-60 cell. Then a micron-sized femtopipette tip captures the mitochondrion for subsequent analysis. Multiple rounds of conventional DNA amplification and standard sequencing methods enable the detection of a heteroplasmic mixture in the mtDNA from a single mitochondrion. SIGNIFICANCE: Molecular analysis of mtDNA from the individually extracted mitochondrion demonstrates that a heteroplasmy is present in single mitochondria at various ratios consistent with the 50/50 heteroplasmy ratio found in single cells that contain multiple mitochondria.


Assuntos
DNA Mitocondrial/genética , Mitocôndrias/metabolismo , Técnicas Citológicas , DNA/genética , Células HL-60 , Humanos , Doenças Mitocondriais/genética , Miopatias Mitocondriais/genética , Modelos Genéticos , Mutação , Reação em Cadeia da Polimerase/métodos , Análise de Sequência de DNA , Raios Ultravioleta
3.
Langmuir ; 24(9): 4975-8, 2008 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-18366235

RESUMO

We inertially inject and study the contents of optically trappable aqueous nanodroplets (hydrosomes) emulsified in a perfluorinated matrix. A new piezoelectric actuated device for production of single hydrosomes on demand is introduced. Hydrosomes containing enhanced green fluorescent protein (EGFP) were injected, optically trapped, and held at the focus of an excitation laser in a confocal microscope, and single-molecule photobleaching events were observed. The rotational diffusion time of EGFP in trapped hydrosomes was measured using time-resolved fluorescence anisotropy. In free solution, the mean rotational diffusion time was determined to be 13.8 +/- 0.1 ns at 3 microM and 14.0 +/- 0.2 ns at 10 microM. In hydrosomes, the mean rotational diffusion time was similar and determined to be 12.6 +/- 1.0 ns at 3 microM and 15.5 +/- 1.6 ns at 10 microM. We conclude that the rotational motion inside the nanodroplets is consistent with rotation in free solution and that the protein therefore does not aggregate at the water-oil interface. Protein can be confined in hydrosomes with high efficiency using this technique, which provides an alternative to surface attachment or lipid encapsulation and opens up new avenues of research using single molecules contained in fluid nanovolumes.


Assuntos
Proteínas de Fluorescência Verde/química , Nanoestruturas/química , Espectrofotometria , Termodinâmica
4.
Proc Natl Acad Sci U S A ; 103(5): 1173-7, 2006 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-16432242

RESUMO

We create long polymer nanotubes by directly pulling on the membrane of polymersomes using either optical tweezers or a micropipette. The polymersomes are composed of amphiphilic diblock copolymers, and the nanotubes formed have an aqueous core connected to the aqueous interior of the polymersome. We stabilize the pulled nanotubes by subsequent chemical cross-linking. The cross-linked nanotubes are extremely robust and can be moved to another medium for use elsewhere. We demonstrate the ability to form networks of polymer nanotubes and polymersomes by optical manipulation. The aqueous core of the polymer nanotubes together with their robust character makes them interesting candidates for nanofluidics and other applications in biotechnology.


Assuntos
Nanotubos/química , Polímeros/química , Fenômenos Químicos , Físico-Química , Reagentes de Ligações Cruzadas/farmacologia , Bicamadas Lipídicas/química , Teste de Materiais , Microscopia Confocal , Microscopia Eletrônica de Transmissão , Microscopia de Vídeo , Nanotecnologia , Temperatura
5.
Langmuir ; 21(23): 10814-7, 2005 Nov 08.
Artigo em Inglês | MEDLINE | ID: mdl-16262357

RESUMO

The morphology of self-assembled phospholipid membranes (e.g., micelles, vesicles, rods, tubes, etc.) depends on the method of formation, secondary manipulation, temperature, and storage conditions. In this contribution, microfluidic systems are used to create pure phosphatidylcholine (PC) micro- and nanotubes with unprecedented lengths. Tubes up to several centimeters in length and aligned with the long axis of the microchannel were created from spots of dry films of 1,2-dilauroyl-sn-glycero-3-phosphocholine (DLPC), 1,2-dimyristoyl-sn-glycero-3-phosphocholine (DMPC), and 1,2-dipalmitoyl-sn-glycero-3-phosphocholine (DPPC). These high aspect ratio structures, which, to our knowledge, represent the first examples of extended tubes formed from pure PC lipids, were examined by fluorescence microscopy, electron and optical microscopy, and optical manipulation tools (i.e., a laser trap and laser scalpel) to characterize structure and stability. In particular, the tubular structure was confirmed by observation of fluorescent dyes that were sequestered within the aqueous cavity or within the phospholipid tube. Compared to other phospholipid tubes, the tubes formed from PC lipids in microfluidic channels show high mechanical stability and rigidity that depend on tube size, age, and storage conditions.


Assuntos
Microfluídica/instrumentação , Nanotubos , Fosfatidilcolinas/química , Microscopia de Fluorescência
6.
Biophys J ; 83(4): 1965-73, 2002 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-12324415

RESUMO

We report observations in real time of thermally driven adhesion and dissociation between a monoclonal IgE antibody and its specific antigen N-epsilon-2,4-dinitrophenyl-L-lysine. Both molecules were attached to the surfaces of different polystyrene microspheres trapped by optical tweezers. Monitoring spontaneous successive attachment and detachment events allowed a direct determination of the reaction-limited detachment rate k(off) for a single bond and also for multiple bonds. We observed both positive and negative cooperativity between multiple bonds depending on whether the antigen was linked to the microsphere with or without a tether, respectively.


Assuntos
Reações Antígeno-Anticorpo , Imunoglobulina E/química , Lisina/análogos & derivados , Lisina/química , Fenômenos Biofísicos , Biofísica , Adesão Celular , Relação Dose-Resposta a Droga , Citometria de Fluxo , Haptenos/química , Imunoglobulina E/metabolismo , Cinética , Lisina/metabolismo , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA