Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 129
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Cardiovasc Electrophysiol ; 35(1): 136-145, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37990448

RESUMO

INTRODUCTION: Pulmonary vein isolations (PVI) are being performed using a high-power, short-duration (HPSD) strategy. The purpose of this study was to compare the clinical efficacy and safety outcomes of an HPSD versus low-power, long-duration (LPLD) approach to PVI in patients with paroxysmal atrial fibrillation (AF). METHODS: Patients were grouped according to a HPSD (≥40 W) or LPLD (≤35 W) strategy. The primary endpoint was the 1-year recurrence of any atrial arrhythmia lasting ≥30 s, detected using three 14-day ambulatory continuous ECG monitoring. Procedural and safety endpoints were also evaluated. The primary analysis were regression models incorporating propensity scores yielding adjusted relative risk (RRa ) and mean difference (MDa ) estimates. RESULTS: Of the 398 patients included in the AWARE Trial, 173 (43%) underwent HPSD and 225 (57%) LPLD ablation. The distribution of power was 50 W in 75%, 45 W in 20%, and 40 W in 5% in the HPSD group, and 35 W with 25 W on the posterior wall in the LPLD group. The primary outcome was not statistically significant at 30.1% versus 22.2% in HPSD and LPLD groups with RRa 0.77 (95% confidence interval [CI]) 0.55-1.10; p = .165). The secondary outcome of repeat catheter ablation was not statistically significant at 6.9% and 9.8% (RRa 1.59 [95% CI 0.77-3.30]; p = .208) respectively, nor was the incidence of any ECG documented AF during the blanking period: 1.7% versus 8.0% (RRa 3.95 [95% CI 1.00-15.61; p = .049) in the HPSD versus LPLD group respectively. The total procedure time was significantly shorter in the HPSD group (MDa 97.5 min [95% CI 84.8-110.4)]; p < .0001) with no difference in adjudicated serious adverse events. CONCLUSIONS: An HPSD strategy was associated with significantly shorter procedural times with similar efficacy in terms of clinical arrhythmia recurrence. Importantly, there was no signal for increased harm with a HPSD strategy.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Veias Pulmonares/cirurgia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Resultado do Tratamento , Recidiva
2.
J Cardiovasc Electrophysiol ; 35(4): 625-638, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38174841

RESUMO

INTRODUCTION: The utility of ablation index (AI) to guide ventricular tachycardia (VT) ablation in patients with structural heart disease is unknown. The aim of this study was to assess procedural characteristics and clinical outcomes achieved using AI-guided strategy (target value 550) or conventional non-AI-guided parameters in patients undergoing scar-related VT ablation. METHODS: Consecutive patients (n = 103) undergoing initial VT ablation at a single center from 2017 to 2022 were evaluated. Patient groups were 1:1 propensity-matched for baseline characteristics. Single lesion characteristics for all 4707 lesions in the matched cohort (n = 74) were analyzed. The impact of ablation characteristics was assessed by linear regression and clinical outcomes were evaluated by Cox proportional hazard model. RESULTS: After propensity-matching, baseline characteristics were well-balanced between AI (n = 37) and non-AI (n = 37) groups. Lesion sets were similar (scar homogenization [41% vs. 27%; p = .34], scar dechanneling [19% vs. 8%; p = .18], core isolation [5% vs. 11%; p = .4], linear and elimination late potentials/local abnormal ventricular activities [35% vs. 44%; p = .48], epicardial mapping/ablation [11% vs. 14%; p = .73]). AI-guided strategy had 21% lower procedure duration (-47.27 min, 95% confidence interval [CI] [-81.613, -12.928]; p = .008), 49% lower radiofrequency time per lesion (-13.707 s, 95% CI [-17.86, -9.555]; p < .001), 21% lower volume of fluid administered (1664 cc [1127, 2209] vs. 2126 cc [1750, 2593]; p = .005). Total radiofrequency duration (-339 s [-24%], 95%CI [-776, 62]; p = .09) and steam pops (-155.6%, 95% CI [19.8%, -330.9%]; p = .08) were nonsignificantly lower in the AI group. Acute procedural success (95% vs. 89%; p = .7) and VT recurrence (0.97, 95% CI [0.42-2.2]; p = .93) were similar for both groups. Lesion analysis (n = 4707) demonstrated a plateau in the magnitude of impedance drops once reaching an AI of 550-600. CONCLUSION: In this pilot study, an AI-guided ablation strategy for scar-related VT resulted in shorter procedure time and average radiofrequency time per lesion with similar acute procedural and intermediate-term clinical outcomes to a non-AI-guided approach utilizing traditional ablation parameters.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Humanos , Projetos Piloto , Cicatriz/diagnóstico , Cicatriz/etiologia , Cicatriz/cirurgia , Resultado do Tratamento , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Arritmias Cardíacas/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos
3.
J Cardiovasc Electrophysiol ; 35(1): 60-68, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37888200

RESUMO

INTRODUCTION: Carina breakthrough (CB) at the right pulmonary vein (RPV) can occur after circumferential pulmonary vein isolation (PVI) due to epicardial bridging or transient tissue edema. High-power short-duration (HPSD) ablation may increase the incidence of RPV CB. Currently, the surrogate of ablation parameters to predict RPV CB is not well established. This study investigated predictors of RPV CB in patients undergoing ablation index (AI)-guided PVI with HPSD. METHODS: The study included 62 patients with symptomatic atrial fibrillation (AF) who underwent AI-guided PVI using HPSD. Patients were categorized into two groups based on the presence or absence of RPV CB. Lesions adjacent to the RPV carina were assessed, and CB was confirmed through residual voltage, low voltage along the ablation lesions, and activation wavefront propagation. RESULTS: Out of the 62 patients, 21 (33.87%) experienced RPV CB (Group 1), while 41 (66.13%) achieved first-pass RPV isolation (Group 2). Despite similar AI and HPSD, patients with RPV CB had lower contact force (CF) at lesions adjacent to the RPV carina. Receiver operating characteristic (ROC) curve analysis identified CF < 10.5 g as a predictor of RPV CB, with 75.7% sensitivity and 56.2% specificity (area under the curve: 0.714). CONCLUSION: In patients undergoing AI-guided PVI with HPSD, lower CF adjacent to the carina was associated with a higher risk of RPV CB. These findings suggest that maintaining higher CF during ablation in this region may reduce the occurrence of RPV CB.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Veias Pulmonares/cirurgia , Ablação por Cateter/efeitos adversos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Resultado do Tratamento , Recidiva
4.
J Cardiovasc Electrophysiol ; 35(3): 469-477, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38282257

RESUMO

INTRODUCTION: The optimized ablation index (AI) value for catheter ablation of atrial fibrillation (AF) remains to be defined. We aimed to compare the efficacy and safety of CLOSE protocol and lower AI protocol in paroxysmal AF. METHODS AND RESULTS: Patients with symptomatic, drug-resistant paroxysmal AF for first ablation were prospectively enrolled from September 2020 to January 2022. The patients were randomly divided into CLOSE group (AI ≥ 550 for anterior/roof segments and ≥400 for posterior/inferior segments) and lower AI group (AI ≥ 450 for anterior/roof segments and ≥350 for posterior/inferior segments). First-pass isolation, acute pulmonary vein (PV) reconnections, 1-year arrhythmia recurrence, and major complications were assessed. Of the 270 enrolled patients, 238 completed 1-year follow-up (118 in CLOSE group and 120 in lower AI group). First-pass isolation in left PVs was higher in CLOSE group (71.2% vs. 53.3%, p = .005). Acute PV reconnections were comparable between groups (9.3% vs. 14.2%, p = .246). At 1 year, 86.4% in CLOSE group versus 81.7% in lower AI group were free from atrial arrhythmia (log rank p = .334). The proportion difference was -4.8% (95% CI: -14.1% to 4.6%), and p = .475 for noninferiority. Stroke occurred in four patients of lower AI group, and no cardiac tamponade, atrioesophageal fistula, major bleeding or death occurred post procedure. CONCLUSION: For patients with paroxysmal AF and treated by AI-guided PV ablation, lower AI is not noninferior to CLOSE protocol.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia , Resultado do Tratamento , Protocolos Clínicos
5.
J Cardiovasc Electrophysiol ; 34(9): 1811-1819, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37595097

RESUMO

INTRODUCTION: Although left atrial wall thickness (LAWT) is known to be varied, a fixed target Ablation Index (AI) based pulmonary vein isolation (PVI) has been suggested in catheter ablation for atrial fibrillation (AF). We aimed to evaluate the efficacy and safety of PVI applying tailored AI based on LAWT assessed by cardiac computed tomography (CT). METHODS: The thick segment was defined as the segment including ≥LAWT grade 3 (≥1.5 mm). The fixed AI strategy was defined as AI targets were 450 on the anterior/roof segments and 350 on the posterior/inferior/carina segments regardless of LAWT. The tailored AI strategy consisted of AI increasing the targets to 500 on the anterior/roof segments and to 400 on the posterior/inferior/carina segments when ablating the thick segment. After PVI, acute pulmonary vein (PV) reconnection, defined by the composite of residual potential and early reconnection, was evaluated. RESULTS: A total of 156 patients (paroxysmal AF 72%) were consecutively included (86 for the fixed AI group and 70 for the tailored AI group). The tailored AI group showed a significantly lower rate of segments with acute PV reconnection than the fixed AI group (8% vs. 5%, p = .007). The tailored AI group showed a trend for shorter ablation time for PVI. One-year AF/atrial tachycardia free survival rate was similar in two groups (87.2% in the fixed AI group and 90.0% in the tailored AI group, p = .606). CONCLUSION: Applying tailored AI based on the LAWT was a feasible and effective strategy to reduce acute PV reconnection after PVI.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Tomografia Computadorizada por Raios X , Ablação por Cateter/efeitos adversos
6.
J Cardiovasc Electrophysiol ; 34(9): 1820-1827, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37493500

RESUMO

INTRODUCTION: To investigate the optimal range of quantitative ablation index (AI) value during superior vena cava (SVC) electrical isolation by radiofrequency catheter ablation (RFCA). METHODS: First, in a development cohort of patients with atrial fibrillation (AF), the RFCA with 40 W was performed to complete SVC isolation guided by the conduction breakthrough point from the right atrium to SVC. Then, the range of AI value was calculated by offline analysis on different segments of SVC. Lastly, for the validation of AF patients, the safety and effectiveness of SVC isolation with the optimized target range of AI value were evaluated with an additional adenosine test. RESULTS: A total of 101 patients with AF were included in the study (44 patients in the development cohort/57 in the validation cohort). The segmental ablation strategy was applied in 70% of the patients. According to the offline analysis of the AI values in the development cohort, the target AI value range was set as 350-400. The success rate of SVC isolation in the validation cohort was significantly higher than that in the exploration cohort (100% vs. 90.9%, p = .02), and no complications occurred in the exploration cohort. During the adenosine test, the recovery rate of electrical conduction in SVC was significantly lower than that in the pulmonary vein (3.5% vs. 17.5%). CONCLUSION: The target AI value with a range from 350 to 400 is safe and effective for high-power RFCA to complete SVC isolation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Veia Cava Superior/cirurgia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Átrios do Coração , Frequência Cardíaca , Ablação por Cateter/efeitos adversos , Adenosina , Veias Pulmonares/cirurgia , Resultado do Tratamento
7.
J Cardiovasc Electrophysiol ; 34(1): 82-89, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36321661

RESUMO

INTRODUCTION: Aim of this study was to evaluate the incidence of ablation-induced endoscopically detected esophageal lesions (EDEL) and gastroparesis in patients undergoing high-power short-duration (HPSD) atrial fibrillation (AF) ablation using different target ablation index (AI) values. METHODS AND RESULTS: Consecutive patients undergoing AF ablation were included. Radiofrequency (RF) ablation was performed using HPSD ablation (50 W, target AI of 320 and 350 (group 1) and 380 (group 2) at posterior wall). Postablation endoscopy was performed in all patients. In total, 233 patients (66.8 ± 10 years; 52% male) were included consecutively (n = 137 patients in group 1 and n = 96 patients in group 2). Mean AI values und RF time at posterior wall was significantly higher and longer in group 2 compared to group 1 patients (413 ± 9 vs. 392 ± 19 AI, p < 0.01; 9.0 ± 0.8 s vs. 7.8 ± 0.7 s, p < 0.01). Esophageal endoscopy revealed esophageal lesions or gastroparesis in 43 of 233 patients (18.5%) in the total cohort (13.1% in group 1 and 26.0% in group 2; p = 0.02). Incidence of EDEL was 8.0% and 13.5% in group 1 and group 2, respectively. According to logistic analysis incidence of EDEL and/or gastroparesis was significantly lower in patients with a higher body mass index and higher in group 2 patients compared to group 1 patients. CONCLUSION: The incidence of EDEL or gastroparesis in patients undergoing HPSD AF ablation was 18.5% in the total cohort. The risk of EDEL and gastroparesis was associated with a higher AI target value of 380 compared to 320 and 350 at posterior wall and was reversely associated with body mass index.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Gastroparesia , Veias Pulmonares , Humanos , Masculino , Feminino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Incidência , Gastroparesia/diagnóstico , Gastroparesia/epidemiologia , Gastroparesia/etiologia , Esôfago/diagnóstico por imagem , Esôfago/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia , Resultado do Tratamento
8.
Europace ; 25(9)2023 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-37490850

RESUMO

AIMS: The effectiveness of pulmonary vein isolation (PVI) guided by VISITAG SURPOINT (VS) has been demonstrated in Western populations. However, data for Asian populations are limited. VS settings may differ for Asians, given their smaller body size. This study aimed to describe outcomes of radiofrequency atrial fibrillation (AF) ablation guided by VS in a large Asian population. METHODS AND RESULTS: The prospective, observational, multicentre MIYABI registry collected real-world data from patients undergoing VS-guided AF ablation using ThermoCool SmartTouch and ThermoCool SmartTouch SF catheters from 50 Japanese centres. All patients had paroxysmal AF or persistent AF for <6 months. Primary adverse events (PAEs) were evaluated for safety. The primary efficacy endpoint was the proportion of patients with PVI at the end of the procedure. Mid-term effectiveness (up to 12 months) was evaluated by freedom from documented atrial arrhythmias. Of the 1011 patients enrolled, 1002 completed AF ablation. The mean number of VS values per procedure was 428.8 on the anterior wall and 400.4 on the posterior wall. Nine patients (0.9%) experienced PAEs. Upon procedure completion, 99.7% of patients had PVI. Twelve-month freedom from atrial arrhythmia recurrence was 88.5%; 5.7% of patients were re-ablated. At repeat ablation, 54% of RSPV, 73% of RIPV, 70% of LSPV, and 86% of LIPV evaluated remained durably isolated. CONCLUSION: Despite lower anterior wall VS values compared with the CLOSE protocol (≥550), the present study demonstrated comparable efficacy outcomes, indicating that a VS of ≥550 for the anterior wall may not be necessary for Asian patients.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/etiologia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Japão , Estudos Prospectivos , Veias Pulmonares/cirurgia , Recidiva , Sistema de Registros , Resultado do Tratamento
9.
Europace ; 25(6)2023 06 02.
Artigo em Inglês | MEDLINE | ID: mdl-37345859

RESUMO

AIMS: Pulmonary vein isolation (PVI) guided by the Ablation Index (AI) has shown high acute and mid-term efficacy in the treatment of paroxysmal atrial fibrillation (AF). Previous data before the AI-era had suggested that wide-area circumferential ablation (WACA) was preferable to ostial ablation. However, with the use of AI, we hypothesize that ostial circumferential ablation is non-inferior to WACA and can improve outcomes in paroxysmal AF. METHODS AND RESULTS: Prospective, multicentre, non-randomized, non-inferiority study of consecutive patients were referred for paroxysmal AF ablation from January 2020 to September 2021. All procedures were performed using the AI software, and patients were separated into two different groups: WACA vs. ostial circumferential ablation. Acute reconnection, procedural data, and 1-year arrhythmia recurrence were assessed. During the enrolment period, 162 patients (64% males, mean age of 60 ± 11 years) fulfilled the study inclusion criteria-81 patients [304 pulmonary vein (PV)] in the WACA group and 81 patients (301 PV) in the ostial group. Acute PV reconnection was identified in 7.9% [95% confidence interval (CI), 4.9-11.1%] of PVs in the WACA group compared with 3.3% (95% CI, 1.8-6.1%) of PVs in the ostial group [P < 0.001 for non-inferiority; adjusted odds ratio 0.51 (95% CI, 0.23-0.83), P = 0.05]. Patients in the WACA group had longer ablation (35 vs. 29 min, P = 0.001) and procedure (121 vs. 102 min, P < 0.001) times. No significant difference in arrhythmia recurrence was seen at 1-year of follow-up [11.1% in WACA vs. 9.9% in ostial, hazard ratio 1.13 (95% CI, 0.44-1.94), P = 0.80 for superiority]. CONCLUSION: In paroxysmal AF patients treated with tailored AI-guided PVI, ostial circumferential ablation is not inferior to WACA with regard to acute PV reconnection, while allowing quicker procedures with less ablation time.


Assuntos
Fibrilação Atrial , Veias Pulmonares , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Feminino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Estudos Prospectivos , Razão de Chances , Veias Pulmonares/cirurgia , Software
10.
Europace ; 25(4): 1379-1391, 2023 04 15.
Artigo em Inglês | MEDLINE | ID: mdl-36881791

RESUMO

AIMS: Pulmonary vein isolation using radiofrequency ablation is an effective treatment option for patients with symptomatic atrial fibrillation (AF). Application of high power over a short period of time (HPSD) is reported to create more efficient lesions and may prevent collateral thermal oesophageal injury. This study aims to compare efficacy and safety of two different HPSD ablation approaches using different ablation index settings. METHODS AND RESULTS: Consecutive patients undergoing AF ablation with HPSD (50 W; ablation index-guided) using the ThermoCool SmartTouch SF catheter were included. Patients were grouped by ablation protocol: ablation with target ablation index (AI) of 400 on the anterior left atrial wall vs. 300 at the posterior left atrial wall (AI 400/300) or AI 450/350 was performed upon the operator's preference and compared. Peri-procedural parameters and complications were recorded, and incidences of endoscopically detected thermal oesophageal lesions (EDEL) analysed. Recurrence rates after a mean follow-up of 25 ± 7 months and reconnection patterns in patients undergoing redo procedures were investigated. A total of 795 patients (67 ± 10 years; 58% male; 48% paroxysmal AF) underwent a first AF ablation with HPSD (211 in group AI 400/300 and 584 in group 450/350). Median procedure time was 82.9 ± 24.6 min with longer ablation times in patients with target AI 400/300 due to higher intraprocedural reconnection rates, increased box lesions, and additional right atrial isthmus ablations. EDEL rates among target AI 400/300 procedures were significantly lower (3% vs. 7%; P = 0.019). Correspondingly, AI 450/350 was the strongest independent predictor of post-ablation EDEL (OR 4.799, CI 1.427-16.138, P = 0.011). Twelve-month (76% vs. 76%; P = 0.892) and long-term ablation single procedure success (68% vs. 71%; log-rank P = 0.452) after a mean of 25 ± 7 months were comparable among both target AI groups; however, long-term success was significantly higher for paroxysmal AF compared to persistent AF (12 months: 80% vs. 72%; P = 0.010; end of follow-up: 76% vs. 65%; log-rank P = 0.001). One hundred three patients (16%) underwent a redo procedure during follow-up documented comparable pulmonary vein (PV) reconnection among groups. Multivariate predictors of AF recurrence were age, left atrium (LA) size, persistent AF, and extra-PV ablation targets. CONCLUSION: High-power short-duration AF ablation with target AI of 400 for non-posterior wall and 300 for posterior wall lesions resulted in comparable long-term results compared to higher AI (450/350) ablations with significantly lower risk for thermal oesophageal lesions. Older age, larger LA size, persistent AF, and extra-PV ablation targets were identified in a multivariate analysis as independent risk factors for recurrences of atrial arrhythmias.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Masculino , Feminino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/etiologia , Seguimentos , Resultado do Tratamento , Esôfago/cirurgia , Inteligência Artificial , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia , Recidiva
11.
Pacing Clin Electrophysiol ; 46(2): 138-143, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36514201

RESUMO

BACKGROUND: Pulmonary vein isolation (PVI) using radiofrequency catheter ablation is a widely accepted therapy for drug-refractory atrial fibrillation patients. Elimination of the negative component of the local unipolar electrogram (UEGM) during PVI is a marker of transmural lesion formation. The ablation index (AI) can predict the quality of ablation lesion. Combining these two parameters could make PVI safer and efficient. The purpose of this pilot study was to examine the correlation between UEGM modification characteristics of the different target areas of left atrium and the associated AI values during PVI. METHODS: We analyzed 10 patients who underwent PVI using radiofrequency energy. The local electrophysiological properties and ablation parameters of 15 designated areas of interest in the left atria targeted by radiofrequency catheter ablation were collected. RESULTS: Out of the 10 patients, six were men (mean age 66 years) and 80% had paroxysmal AF. The mean time to achieve the UEGM modification in the posterior wall was shorter than that of the anterior wall (8.9 seconds vs. 11.1 s, respectively). The UEGM modification for every lesion was achieved at significantly lower AI values than conventional AIs (p < .001). CONCLUSION: During PVI, the AIs deduced according to the local UEGM modification are markedly shorter than those generally recommended AIs in contemporary practice. This indicates that conventionally recommended AIs could be safely reduced while ensuring the efficacy and quality of radiofrequency ablation during PVI. This approach would probably reduce to risk of collateral thermal injuries.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Masculino , Humanos , Idoso , Feminino , Projetos Piloto , Veias Pulmonares/cirurgia , Fibrilação Atrial/cirurgia , Átrios do Coração , Resultado do Tratamento , Recidiva
12.
Heart Vessels ; 38(1): 90-95, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35852611

RESUMO

Ablation index (AI)-guided ablation is useful for pulmonary vein isolation (PVI) and cavotricuspid isthmus (CTI) ablation. However, the impact of radiofrequency (RF) application power on CTI ablation with a fixed target AI remains unclear. One-hundred-thirty drug-refractory atrial fibrillation and/or atrial flutter patients who underwent AI-guided CTI ablation with or without PVI between July 2020 and August 2021 were randomly assigned to high-power (45 W) and moderate-power (35 W) groups. We performed CTI ablation with the same target AI value in both groups: 500 for the anterior 1/3 segments and 450 for the posterior 2/3 segments. In total, first-pass conduction block of the CTI was obtained in 111 patients (85.4%), with 7 patients (5.4%) showing CTI reconnection. The rate of first-pass conduction block was significantly higher in the 45 W group (61/65, 93.8%) than in the 35 W group (50/65, 76.9%, P = 0.01). CTI ablation and CTI fluoroscopy time were significantly shorter in the 45 W group than in the 35 W group (CTI ablation time: 192.3 ± 84.8 vs. 319.8 ± 171.4 s, P < 0.0001; CTI fluoroscopy time: 125.2 ± 122.4 vs. 171.2 ± 124.0 s, P = 0.039). Although there was no significant difference, steam pops were identified in two patients from the 45 W group at the anterior segment of the CTI. The 45 W ablation strategy was faster and provided a higher probability of first-pass conduction block than the 35 W ablation strategy for CTI ablation with a fixed AI target.


Assuntos
Fibrilação Atrial , Flutter Atrial , Ablação por Cateter , Humanos , Resultado do Tratamento , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Flutter Atrial/diagnóstico , Flutter Atrial/cirurgia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Bloqueio Cardíaco
13.
J Cardiovasc Electrophysiol ; 33(12): 2546-2557, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36284450

RESUMO

INTRODUCTION: The IMPACT study established the role of controlled esophageal cooling in preventing esophageal thermal injury during radiofrequency (RF) ablation for atrial fibrillation (AF). The effect of esophageal cooling on ablation lesion delivery and procedural and patient outcomes had not been previously studied. The objective was to determine the effect of esophageal cooling on the formation of RF lesions, the ability to achieve procedural endpoints, and clinical outcomes. METHODS: Participants in the IMPACT trial underwent AF ablation guided by Ablation Index (30 W at 350-400 AI posteriorly, 40 W at ≥450 AI anteriorly). A blinded 1:1 randomization assigned patients to the use of the ensoETM® device to keep esophageal temperature at 4°C during ablation or standard practice using a single-sensor temperature probe. Ablation parameters and clinical outcomes were analyzed. RESULTS: Procedural data from 188 patients were analyzed. Procedure and fluoroscopy times were similar, and all pulmonary veins were isolated. First-pass pulmonary vein isolation and reconnection at the end of the waiting period were similar in both randomized groups (51/64 vs. 51/68; p = 0.54 and 5/64 vs. 7/68; p = 0.76, respectively). Posterior wall isolation was also similar: 24/33 versus 27/38; p = 0.88. Ablation effect on tissue, measured in impedance drop, was no different between the two randomized groups: 8.6Ω (IQR: 6-11.8) versus 8.76Ω (IQR: 6-12.2; p = 0.25). Arrhythmia recurrence was similar after 12 months (21.1% vs. 24.1%; 95% CI: 0.38-1.84; HR: 0.83; p = 0.66). CONCLUSIONS: Esophageal cooling has been shown to be effective in reducing ablation-related thermal injury during RF ablation. This protection does not compromise standard procedural endpoints or clinical success at 12 months.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Resultado do Tratamento , Átrios do Coração/cirurgia , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/etiologia , Recidiva
14.
J Cardiovasc Electrophysiol ; 33(8): 1725-1733, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35637604

RESUMO

PURPOSE: Since the widespread availability of contact-force sensing catheters, the need for a waiting period after pulmonary vein isolation (PVI) has not been reassessed. We aim to evaluate whether a waiting period is still necessary after PVI guided by the ablation Index (AI). METHODS: Prospective, multicenter, randomized study of consecutive patients referred for paroxysmal atrial fibrillation (AF) ablation from May 2019 to February 2020. Patients were randomized in a 1:1 ratio to PVI with versus without a waiting period of 20 min. Acute pulmonary vein (PV) reconnection after adenosine challenge was the primary endpoint. A per-protocol analysis was designed to determine whether a strategy of dismissing the waiting period after PVI was noninferior to waiting for 20 min for identifying acute PV reconnection. PVI was guided by tailored AI values and an interlesion distance ≤6 mm. RESULTS: During the enrollment period, 167 patients (56% males, mean age of 57 ± 14 years) fulfilled the study inclusion criteria - 84 patients (308 PV) in the waiting period group (Group A) and 83 patients (314 PV) in the group without a waiting period (Group B). Acute PV reconnection was identified in 3.8% (95% confidence interval [CI], 1.7%-5.9%) of PVs in the study group B compared to 2.9% (95% CI, 1.0%-4.8%) of PVs in the Group A (p = .002 for non-inferiority). At 1-year follow-up, there was no significant difference in arrhythmia recurrence between groups (9.5% in Group A vs. 9.6% in Group B, hazard ratio: 1.03 [95% CI, 0.39-2.73], p = .98). CONCLUSION: In paroxysmal AF patients submitted to ablation, a tailored PVI guided by the AI rendered a 20-min waiting period unnecessary.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Adulto , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Veias Pulmonares/cirurgia , Recidiva , Software , Resultado do Tratamento
15.
J Cardiovasc Electrophysiol ; 33(4): 698-712, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35048448

RESUMO

BACKGROUND: Ablation Index (AI) is a multiparametric quality marker to assess the durability of radiofrequency (RF) lesions. The comparative effectiveness and safety of AI versus time-based energy dosing for ablation of ventricular arrhythmias are unknown. OBJECTIVE: We compared AI and time-based RF dosing strategies in the left ventricles (LVs) of freshly harvested porcine hearts. METHODS: Ablation was performed in vitro with an open-irrigated ablation catheter (Thermocool ST/SF), 40 W, contact force 10-15 g. Tissue samples were stained in triphenyltetrazolium chloride for the measurement of lesion dimensions. RESULTS: A total of 560 lesions were performed (AI-group: [n = 360]; time-group: [n = 200]). Using normal saline (NS) (n = 280), growth in lesion depth slowed after 30 s and AI > 550 in comparison to width, volume, and magnitude of impedance drops which continued to increase with longer RF duration. Risk of steam pop (SP) was higher for RF > 30 s (RF < 30 s:1 SP [2.5%] vs. RF > 30 s: 15 SP [25%]; p = .002) or AI targets >550 (AI: 350-550: 2 SP [2%] vs. AI 600-750: 15 SP [19%]; p = .001). Using half-normal saline (HNS) (n = 280), lesion dimension and impedance drops were larger and growth in lesion depth slowed earlier (AI: 500). Risk of SPs was higher above AI 550 (AI: 350-550: 7 [7%] SPs vs. AI 600-750: 28 [35%] SPs; p < .00001). While codependent variables, correlation between AI and time was modest-to-strong but decreased with longer RF duration. CONCLUSION: In this ex vivo study, AI was a better predictor of lesion dimensions than ablation time and magnitude of impedance drop in the LV using NS and HNS irrigation. AI targets above 550 led to a higher risk of SPs. Future trials are required to verify these findings.


Assuntos
Ablação por Cateter , Solução Salina , Animais , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Desenho de Equipamento , Coração , Ventrículos do Coração/patologia , Ventrículos do Coração/cirurgia , Suínos , Irrigação Terapêutica/efeitos adversos , Irrigação Terapêutica/métodos
16.
J Cardiovasc Electrophysiol ; 33(1): 64-72, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34820931

RESUMO

INTRODUCTION: Radiofrequency (RF) atrial fibrillation (AF) ablation using a catheter dragging technique may shorten procedural duration and improve durability of pulmonary vein isolation (PVI) by creating uninterrupted linear ablation lesions. We compared a novel AF ablation approach guided by Grid annotation allowing for "drag lesions" with a standard point-by-point ablation approach in a single-center randomized study. METHODS: Eighty-eight paroxysmal or persistent AF patients were randomized 1:1 to undergo RF-PVI with either a catheter dragging ablation technique guided by Grid annotation or point-by-point ablation guided by Ablation Index (AI) annotation. In the Grid annotation arm, ablation was visualized using 1 mm³ grid points coloring red after meeting predefined stability and contact force criteria. In the AI annotation arm, ablation lesions were created in a point-by-point fashion with AI target values set at 380 and 500 for posterior/inferior and anterior/roof segments, respectively. Patients were followed up for 12 months after PVI using ECGs, 24-h Holter monitoring and a mobile-based one-lead ECG device. RESULTS: Procedure time was not different between the two randomization arms (Grid annotation 71 ± 19 min, AI annotation 72 ± 26 min, p = .765). RF time was significantly longer in the Grid annotation arm compared with the AI annotation arm (49 ± 8 min vs. 37 ± 8 min, respectively, p < .001). Atrial tachyarrhythmia recurrence was documented in 10 patients (23%) in the Grid annotation arm compared with 19 patients (42%) in the AI annotation arm with time to recurrence not reaching statistical significance (p = .074). CONCLUSIONS: This study shows that a Grid annotation-guided dragging approach provides an alternative to point-by-point RF-PVI using AI annotation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Humanos , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
17.
J Cardiovasc Electrophysiol ; 33(6): 1136-1145, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35118734

RESUMO

INTRODUCTION: Ablation of atrial fibrillation (AF) with high-power-short-duration (HPSD) radiofrequency (RF) technology is emerging as a new standard of care in many electrophysiology laboratories. While procedural short-term efficacy and efficiency is very promising, little is known about mid- to long-term effects of HPSD ablation for pulmonary vein isolation (PVI) and left atrial substrate modification. METHODS: In a single-center registry, 412 AF procedures were performed in 400 individual patients using a standardized CLOSE protocol-guided fixed 50 W HPSD ablation, aiming for an ablation index (AI) of 400 on the posterior and 550 on the anterior wall. Additional substrate-tailored lines were performed when required. RESULTS: After a mean clinical follow-up of 337 ± 134 days, 15 patients suffered from AF recurrence beyond the blinding period. Twelve gave consent to the indicated reablation. Here, 11 of 12 patients had chronic isolation of all four pulmonary veins (PV). In three of six patients, a reconnection of additional left atrial ablation lines was revealed. Ten out of 12 patients showed progressive fibrous atrial cardiomyopathy and required additional left atrial substrate modification or reisolation of left-atrial lines. During the follow-up no clinical case of atrioesophageal fistula was registered. No PV stenosis after initial HPSD PVI was documented. CONCLUSIONS: Patients requiring reablation of AF or other atrial tachycardia after a fixed 50 W HPSD circumferential PVI and substrate modification predominantly suffer from progressive fibrous atrial cardiomyopathy, while PV reconnection appears to be a rare cause of AF recurrence.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Humanos , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
18.
J Cardiovasc Electrophysiol ; 33(11): 2276-2284, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35979645

RESUMO

INTRODUCTION: Pulmonary vein isolation (PVI) using high-power-short-duration (HPSD) radiofrequency ablation (RF) is emerging as the standard of care for treatment of atrial fibrillation (AF). While procedural short-term to midterm efficacy and efficiency are very promising, this registry aims to investigate esopahgeal safety using an optimized ablation approach. METHODS: In a single-center experience, 388 consecutive standardized first-time AF ablation were performed using a CLOSE-guided-fixed-50 W-circumferential PVI and substrate modification without intraprocedural esophageal temperature measurement. Three hundred patients underwent postprocedural esophageal endoscopy to diagnose and grade endoscopically detected esophageal lesions (EDEL) and were included in the analysis. RESULTS: EDEL were detected in 35 of 300 patients (11.6%), 25 of 35 were low-grade Kansas-city-classification (KCC) 1 lesions with fast healing tendencies. Six patients suffered KCC 2a lesions, 4 patients had KCC 2b lesions (1.3% of all patients). No esophageal perforation or fistula formation was observed. Patient baseline characteristics, especially patients age, gender, and body mass index did not influence EDEL incidence. Additional posterior box isolation did not increase the incidence of EDEL. In patients diagnosed with EDEL, mean catheter contact force during posterior wall ablation was higher (11.9 ± 1.8 vs. 14.7 ± 3 g, p < .001), mean RF duration was shorter (11.9 ± 1 vs. 10.7 ± 1.2 s, p < .001), while achieved ablation index was not different between groups (434 ± 4.9 vs. 433 ± 9.5, n.s.). CONCLUSION: Incidence of EDEL after CLOSE-guided-50 W-HPSD PVI is lower compared to historical cohorts using standard-power RF settings. Catheter contact force during posterior HPSD ablation should not exceed 15 g.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Veias Pulmonares/cirurgia , Fatores de Risco , Ablação por Cateter/efeitos adversos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Sistema de Registros , Resultado do Tratamento , Recidiva
19.
Europace ; 24(3): 390-399, 2022 03 02.
Artigo em Inglês | MEDLINE | ID: mdl-34480548

RESUMO

AIMS: To determine if adapting the ablation index (AI) to the left atrial wall thickness (LAWT), which is a determinant of lesion transmurality, is feasible, effective, and safe during paroxysmal atrial fibrillation (PAF) ablation. METHODS AND RESULTS: Consecutive patients referred for PAF first ablation. Left atrial wall thickness three-dimensional maps were obtained from multidetector computed tomography and integrated into the CARTO navigation system. Left atrial wall thickness was categorized into 1 mm layers and AI was titrated to the LAWT. The ablation line was personalized to avoid thicker regions. Primary endpoints were acute efficacy and safety, and freedom from atrial fibrillation (AF) recurrences. Follow-up (FU) was scheduled at 1, 3, 6, and every 6 months thereafter. Ninety patients [60 (67%) male, age 58 ± 13 years] were included. Mean LAWT was 1.25 ± 0.62 mm. Mean AI was 366 ± 26 on the right pulmonary veins with a first-pass isolation in 84 (93%) patients and 380 ± 42 on the left pulmonary veins with first-pass in 87 (97%). Procedure time was 59 min (49-66); radiofrequency (RF) time 14 min (12.5-16); and fluoroscopy time 0.7 min (0.5-1.4). No major complication occurred. Eighty-four out of 90 (93.3%) patients were free of recurrence after a mean FU of 16 ± 4 months. CONCLUSION: Personalized AF ablation, adapting the AI to LAWT allowed pulmonary vein isolation with low RF delivery, fluoroscopy, and procedure time while obtaining a high rate of first-pass isolation, in this patient population. Freedom from AF recurrences was as high as in more demanding ablation protocols. A multicentre trial is ongoing to evaluate reproducibility of these results.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Idoso , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Recidiva , Reprodutibilidade dos Testes , Resultado do Tratamento
20.
Europace ; 24(12): 1909-1916, 2022 Dec 09.
Artigo em Inglês | MEDLINE | ID: mdl-35851917

RESUMO

AIMS: Left atrial ablation using radiofrequency (RF) is associated with endoscopically detected thermal oesophageal lesions (EDELs). The aim of this study was to compare EDEL occurrence after conventional contact force-guided (CFG) RF ablation vs. an ablation index-guided (AIG) approach in clinical routine of voltage-guided ablation (VGA). Predictors of EDEL were also assessed. METHODS AND RESULTS: This study compared CFG (n = 100) with AIG (n = 100) in consecutive atrial fibrillation ablation procedures, in which both pulmonary vein isolation and VGA were performed. In the AIG group, AI targets were ≥500 anteriorly and ≥350-400 posteriorly. Upper endoscopy was performed after ablation.The CFG and AIG groups had comparable baseline characteristics. The EDEL occurred in 6 and 5% (P = 0.86) in the CFG and AIG groups, respectively. Category 2 lesions occurred in 4 and 2% (P = 0.68), respectively. All EDEL healed under proton pump inhibitor therapy. The AI > 520 was the only predictor of EDEL [odds ratio (OR) 3.84; P = 0.039]. The more extensive Category 2 lesions were predicted by: AI max > 520 during posterior ablation (OR 7.05; P = 0.042), application of posterior or roof lines (OR 5.19; P = 0.039), existence of cardiomyopathy (OR 4.93; P = 0.047), and CHA2DS2-VASc score (OR 1.71; P = 0.044). The only Category 2 lesion with AI max < 520 (467) occurred in a patient with low body mass index. CONCLUSIONS: Both methods were comparable with respect to clinical complications and EDEL. In consideration of previous reconnection data and our study results regarding oesophageal safety, optimal AI target range might be between 400 and 450.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia , Esôfago , Átrios do Coração/cirurgia , Resultado do Tratamento , Recidiva
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA