Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 130
Filtrar
1.
NMR Biomed ; : e5147, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38561247

RESUMO

Partial Fourier encoding is popular in single-shot (ss) diffusion-weighted (DW) echo planar imaging (EPI) because it enables a shorter echo time (TE) and, hence, improves the signal-to-noise-ratio. Motion during diffusion encoding causes k-space shifting and dispersion, which compromises the quality of the homodyne reconstruction. This work provides a comprehensive understanding of the artifacts in homodyne reconstruction of partial Fourier ss-DW-EPI data in the presence of motion-induced phase and proposes the motion-induced phase-corrected homodyne (mpc-hdyne) reconstruction method to ameliorate these artifacts. Simulations with different types of motion-induced phase were performed to provide an understanding of the potential artifacts that occur in the homodyne reconstruction of partial Fourier ss-DW-EPI data. To correct for the artifacts, the mpc-hdyne reconstruction is proposed. The algorithm recenters k-space, updates the partial Fourier factor according to detected global k-space shifts, and removes low-resolution nonlinear phase before the conventional homodyne reconstruction. The mpc-hdyne reconstruction is tested on both simulation and in vivo data. Motion-induced phase can cause signal overestimation, worm artifacts, and signal loss in partial Fourier ss-DW-EPI data with the conventional homodyne reconstruction. Simulation and in vivo data showed that the proposed mpc-hdyne reconstruction ameliorated artifacts, yielding higher quality DW images compared with conventional homodyne reconstruction. Based on the understanding of the artifacts in homodyne reconstruction of partial Fourier ss-DW-EPI data, the mpc-hdyne reconstruction was proposed and showed superior performance compared with the conventional homodyne reconstruction on both simulation and in vivo data.

2.
NMR Biomed ; 37(5): e5097, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38269568

RESUMO

PURPOSE: Liver T1 mapping techniques typically require long breath holds or long scan time in free-breathing, need correction for B 1 + inhomogeneities and process composite (water and fat) signals. The purpose of this work is to accelerate the multi-slice acquisition of liver water selective T1 (wT1) mapping in a single breath hold, improving the k-space sampling efficiency. METHODS: The proposed continuous inversion-recovery (IR) Look-Locker methodology combines a single-shot gradient echo spiral readout, Dixon processing and a dictionary-based analysis for liver wT1 mapping at 3 T. The sequence parameters were adapted to obtain short scan times. The influence of fat, B 1 + inhomogeneities and TE on the estimation of T1 was first assessed using simulations. The proposed method was then validated in a phantom and in 10 volunteers, comparing it with MRS and the modified Look-Locker inversion-recovery (MOLLI) method. Finally, the clinical feasibility was investigated by comparing wT1 maps with clinical scans in nine patients. RESULTS: The phantom results are in good agreement with MRS. The proposed method encodes the IR-curve for the liver wT1 estimation, is minimally sensitive to B 1 + inhomogeneities and acquires one slice in 1.2 s. The volunteer results confirmed the multi-slice capability of the proposed method, acquiring nine slices in a breath hold of 11 s. The present work shows robustness to B 1 + inhomogeneities ( wT 1 , No B 1 + = 1.07 wT 1 , B 1 + - 45.63 , R 2 = 0.99 ) , good repeatability ( wT 1 , 2 ° = 1 . 0 wT 1 , 1 ° - 2.14 , R 2 = 0.96 ) and is in better agreement with MRS ( wT 1 = 0.92 wT 1 MRS + 103.28 , R 2 = 0.38 ) than is MOLLI ( wT 1 MOLLI = 0.76 wT 1 MRS + 254.43 , R 2 = 0.44 ) . The wT1 maps in patients captured diverse lesions, thus showing their clinical feasibility. CONCLUSION: A single-shot spiral acquisition can be combined with a continuous IR Look-Locker method to perform rapid repeatable multi-slice liver water T1 mapping at a rate of 1.2 s per slice without a B 1 + map. The proposed method is suitable for nine-slice liver clinical applications acquired in a single breath hold of 11 s.


Assuntos
Interpretação de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Humanos , Imageamento por Ressonância Magnética/métodos , Interpretação de Imagem Assistida por Computador/métodos , Fígado/diagnóstico por imagem , Abdome , Respiração , Imagens de Fantasmas , Reprodutibilidade dos Testes , Coração
3.
Eur Radiol ; 34(4): 2437-2444, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37691079

RESUMO

OBJECTIVES: MR imaging-based proton density fat fraction (PDFF) and T2* imaging has shown to be useful for the evaluation of degenerative changes in the spine. Therefore, the aim of this study was to investigate the influence of myelotoxic chemotherapy on the PDFF and T2* of the thoracolumbar spine in comparison to changes in bone mineral density (BMD). METHODS: In this study, 19 patients were included who had received myelotoxic chemotherapy (MC) and had received a MR imaging scan of the thoracolumbar vertebrates before and after the MC. Every patient was matched for age, sex, and time between the MRI scans to two controls without MC. All patients underwent 3-T MR imaging including the thoracolumbar spine comprising chemical shift encoding-based water-fat imaging to extract PDFF and T2* maps. Moreover, trabecular BMD values were determined before and after chemotherapy. Longitudinal changes in PDFF and T2* were evaluated and compared to changes in BMD. RESULTS: Absolute mean differences of PDFF values between scans before and after MC were at 8.7% (p = 0.01) and at -0.5% (p = 0.57) in the control group, resulting in significantly higher changes in PDFF in patients with MC (p = 0.008). BMD and T2* values neither showed significant changes in patients with nor in those without myelotoxic chemotherapy (p = 0.15 and p = 0.47). There was an inverse, yet non-significant correlation between changes in PDFF and BMD found in patients with myelotoxic chemotherapy (r = -0.41, p = 0.12). CONCLUSION: Therefore, PDFF could be a useful non-invasive biomarker in order to detect changes in the bone marrow in patients receiving myelotoxic therapy. CLINICAL RELEVANCE STATEMENT: Using PDFF as a non-invasive biomarker for early bone marrow changes in oncologic patients undergoing myelotoxic treatment may help enable more targeted countermeasures at commencing states of bone marrow degradation and reduce risks of possible fragility fractures. KEY POINTS: Quantifying changes in bone marrow fat fraction, as well as T2* caused by myelotoxic pharmaceuticals using proton density fat fraction, is feasible. Proton density fat fraction could potentially be established as a non-invasive biomarker for early bone marrow changes in oncologic patients undergoing myelotoxic treatment.


Assuntos
Medula Óssea , Prótons , Humanos , Medula Óssea/diagnóstico por imagem , Coluna Vertebral , Imageamento por Ressonância Magnética/métodos , Biomarcadores , Tecido Adiposo/diagnóstico por imagem
4.
Int J Colorectal Dis ; 39(1): 21, 2024 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-38273097

RESUMO

PURPOSE: Sigmoid diverticulitis is a disease with a high socioeconomic burden, accounting for a high number of left-sided colonic resections worldwide. Modern surgical scheduling relies on accurate prediction of operation times to enhance patient care and optimize healthcare resources. This study aims to develop a predictive model for surgery duration in laparoscopic sigmoid resections, based on preoperative CT biometric and demographic patient data. METHODS: This retrospective single-center cohort study included 85 patients who underwent laparoscopic sigmoid resection for diverticular disease. Potentially relevant procedure-specific anatomical parameters recommended by a surgical expert were measured in preoperative CT imaging. After random split into training and test set (75% / 25%) multiclass logistic regression was performed and a Random Forest classifier was trained on CT imaging parameters, patient age, and sex in the training cohort to predict categorized surgery duration. The models were evaluated in the test cohort using established performance metrics including receiver operating characteristics area under the curve (AUROC). RESULTS: The Random Forest model achieved a good average AUROC of 0.78. It allowed a very good prediction of long (AUROC = 0.89; specificity 0.71; sensitivity 1.0) and short (AUROC = 0.81; specificity 0.77; sensitivity 0.56) procedures. It clearly outperformed the multiclass logistic regression model (AUROC: average = 0.33; short = 0.31; long = 0.22). CONCLUSION: A Random Forest classifier trained on demographic and CT imaging biometric patient data could predict procedure duration outliers of laparoscopic sigmoid resections. Pending validation in a multicenter study, this approach could potentially improve procedure scheduling in visceral surgery and be scaled to other procedures.


Assuntos
Laparoscopia , Algoritmo Florestas Aleatórias , Humanos , Estudos de Coortes , Laparoscopia/métodos , Estudos Retrospectivos , Resultado do Tratamento
5.
MAGMA ; 2024 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-38743376

RESUMO

PURPOSE: To investigate the effect of respiratory motion in terms of signal loss in prostate diffusion-weighted imaging (DWI), and to evaluate the usage of partial Fourier in a free-breathing protocol in a clinically relevant b-value range using both single-shot and multi-shot acquisitions. METHODS: A controlled breathing DWI acquisition was first employed at 3 T to measure signal loss from deep breathing patterns. Single-shot and multi-shot (2-shot) acquisitions without partial Fourier (no pF) and with partial Fourier (pF) factors of 0.75 and 0.65 were employed in a free-breathing protocol. The apparent SNR and ADC values were evaluated in 10 healthy subjects to measure if low pF factors caused low apparent SNR or overestimated ADC. RESULTS: Controlled breathing experiments showed a difference in signal coefficient of variation between shallow and deep breathing. In free-breathing single-shot acquisitions, the pF 0.65 scan showed a significantly (p < 0.05) higher apparent SNR than pF 0.75 and no pF in the peripheral zone (PZ) of the prostate. In the multi-shot acquisitions in the PZ, pF 0.75 had a significantly higher apparent SNR than 0.65 pF and no pF. The single-shot pF 0.65 scan had a significantly lower ADC than single-shot no pF. CONCLUSION: Deep breathing patterns can cause intravoxel dephasing in prostate DWI. For single-shot acquisitions at a b-value of 800 s/mm2, any potential risks of motion-related artefacts at low pF factors (pF 0.65) were outweighed by the increase in signal from a lower TE, as shown by the increase in apparent SNR. In multi-shot acquisitions however, the minimum pF factor should be larger, as shown by the lower apparent SNR at low pF factors.

6.
Magn Reson Med ; 89(1): 144-160, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36098347

RESUMO

PURPOSE: To assess the effect of respiratory motion and cardiac driven pulsation in renal DWI and to examine asymmetrical velocity-compensated diffusion encoding waveforms for robust ADC mapping in the kidneys. METHODS: The standard monopolar Stejskal-Tanner pulsed gradient spin echo (pgse) and the asymmetric bipolar velocity-compensated (asym-vc) diffusion encoding waveforms were used for coronal renal DWI at 3T. The robustness of the ADC quantification in the kidneys was tested with the aforementioned waveforms in respiratory-triggered and breath-held cardiac-triggered scans at different trigger delays in 10 healthy subjects. RESULTS: The pgse waveform showed higher ADC values in the right kidney at short trigger delays in comparison to longer trigger delays in the respiratory triggered scans when the diffusion gradient was applied in the feet-head (FH) direction. The coefficient of variation over all respiratory trigger delays, averaged over all subjects was 0.15 for the pgse waveform in the right kidney when diffusion was measured in the FH direction; the corresponding coefficient of variation for the asym-vc waveform was 0.06. The effect of cardiac driven pulsation was found to be small in comparison to the effect of respiratory motion. CONCLUSION: Short trigger delays in respiratory-triggered scans can cause higher ADC values in comparison to longer trigger delays in renal DWI, especially in the right kidney when diffusion is measured in the FH direction. The asym-vc waveform can reduce ADC variation due to respiratory motion in respiratory-triggered scans at the cost of reduced SNR compared to the pgse waveform.


Assuntos
Imagem de Difusão por Ressonância Magnética , Rim , Humanos , Imagem de Difusão por Ressonância Magnética/métodos , Movimento (Física) , Rim/diagnóstico por imagem , Coração/diagnóstico por imagem , Difusão , Reprodutibilidade dos Testes
7.
Magn Reson Med ; 90(3): 894-909, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37093981

RESUMO

PURPOSE: To develop a high spatiotemporal resolution 3D dynamic pulse sequence for preclinical imaging of hyperpolarized [1-13 C]pyruvate-to-[1-13 C]lactate metabolism at 7T. METHODS: A standard 3D balanced SSFP (bSSFP) sequence was modified to enable alternating-frequency excitations. RF pulses with 2.33 ms duration and 900 Hz FWHM were placed off-resonance of the target metabolites, [1-13 C]pyruvate (by approximately -245 Hz) and [1-13 C]lactate (by approximately 735 Hz), to selectively excite those resonances. Relatively broad bandwidth (compared to those metabolites' chemical shift offset) permits a short TR of 6.29 ms, enabling higher spatiotemporal resolution. Bloch equation simulations of the bSSFP response profile guided the sequence parameter selection to minimize spectral contamination between metabolites and preserve magnetization over time. RESULTS: Bloch equation simulations, phantom studies, and in vivo studies demonstrated that the two target resonances could be cleanly imaged without substantial bSSFP banding artifacts and with little spectral contamination between lactate and pyruvate and from pyruvate hydrate. High spatiotemporal resolution 3D images were acquired of in vivo pyruvate-lactate metabolism in healthy wild-type and endogenous pancreatic tumor-bearing mice, with 1.212 s acquisition time per single-metabolite image and (1.75 mm)3 isotropic voxels with full mouse abdomen 56 × 28 × 21 mm3 FOV and fully-sampled k-space. Kidney and tumor lactate/pyruvate ratios of two consecutive measurements in one animal, 1 h apart, were consistent. CONCLUSION: Spectrally selective bSSFP using off-resonant RF excitations can provide high spatio-temporal resolution 3D dynamic images of pyruvate-lactate metabolic conversion.


Assuntos
Ácido Láctico , Ácido Pirúvico , Camundongos , Animais , Ácido Pirúvico/metabolismo , Ácido Láctico/metabolismo , Imageamento por Ressonância Magnética/métodos , Imageamento Tridimensional/métodos , Imagens de Fantasmas , Isótopos de Carbono/metabolismo
8.
Eur Radiol ; 33(3): 1844-1851, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36282311

RESUMO

OBJECTIVE: To evaluate the perception of different types of AI-based assistance and the interaction of radiologists with the algorithm's predictions and certainty measures. METHODS: In this retrospective observer study, four radiologists were asked to classify Breast Imaging-Reporting and Data System 4 (BI-RADS4) lesions (n = 101 benign, n = 99 malignant). The effect of different types of AI-based assistance (occlusion-based interpretability map, classification, and certainty) on the radiologists' performance (sensitivity, specificity, questionnaire) were measured. The influence of the Big Five personality traits was analyzed using the Pearson correlation. RESULTS: Diagnostic accuracy was significantly improved by AI-based assistance (an increase of 2.8% ± 2.3%, 95 %-CI 1.5 to 4.0 %, p = 0.045) and trust in the algorithm was generated primarily by the certainty of the prediction (100% of participants). Different human-AI interactions were observed ranging from nearly no interaction to humanization of the algorithm. High scores in neuroticism were correlated with higher persuasibility (Pearson's r = 0.98, p = 0.02), while higher consciousness and change of accuracy showed an inverse correlation (Pearson's r = -0.96, p = 0.04). CONCLUSION: Trust in the algorithm's performance was mostly dependent on the certainty of the predictions in combination with a plausible heatmap. Human-AI interaction varied widely and was influenced by personality traits. KEY POINTS: • AI-based assistance significantly improved the diagnostic accuracy of radiologists in classifying BI-RADS 4 mammography lesions. • Trust in the algorithm's performance was mostly dependent on the certainty of the prediction in combination with a reasonable heatmap. • Personality traits seem to influence human-AI collaboration. Radiologists with specific personality traits were more likely to change their classification according to the algorithm's prediction than others.


Assuntos
Neoplasias da Mama , Doenças Vasculares , Humanos , Feminino , Estudos Retrospectivos , Algoritmos , Mamografia , Radiologistas , Neoplasias da Mama/diagnóstico por imagem
9.
Eur Radiol ; 33(10): 6892-6901, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37133518

RESUMO

OBJECTIVES: To examine the effect of high-b-value computed diffusion-weighted imaging (cDWI) on solid lesion detection and classification in pancreatic intraductal papillary mucinous neoplasm (IPMN), using endoscopic ultrasound (EUS) and histopathology as a standard of reference. METHODS: Eighty-two patients with known or suspected IPMN were retrospectively enrolled. Computed high-b-value images at b = 1000 s/mm2 were calculated from standard (b = 0, 50, 300, and 600 s/mm2) DWI images for conventional full field-of-view (fFOV, 3 × 3 × 4 mm3 voxel size) DWI. A subset of 39 patients received additional high-resolution reduced-field-of-view (rFOV, 2.5 × 2.5 × 3 mm3 voxel size) DWI. In this cohort, rFOV cDWI was compared against fFOV cDWI additionally. Two experienced radiologists evaluated (Likert scale 1-4) image quality (overall image quality, lesion detection and delineation, fluid suppression within the lesion). In addition, quantitative image parameters (apparent signal-to-noise ratio (aSNR), apparent contrast-to-noise ratio (aCNR), contrast ratio (CR)) were assessed. Diagnostic confidence regarding the presence/absence of diffusion-restricted solid nodules was assessed in an additional reader study. RESULTS: High-b-value cDWI at b = 1000 s/mm2 outperformed acquired DWI at b = 600 s/mm2 regarding lesion detection, fluid suppression, aCNR, CR, and lesion classification (p = < .001-.002). Comparing cDWI from fFOV and rFOV revealed higher image quality in high-resolution rFOV-DWI compared to conventional fFOV-DWI (p ≤ .001-.018). High-b-value cDWI images were rated non-inferior to directly acquired high-b-value DWI images (p = .095-.655). CONCLUSIONS: High-b-value cDWI may improve the detection and classification of solid lesions in IPMN. Combining high-resolution imaging and high-b-value cDWI may further increase diagnostic precision. CLINICAL RELEVANCE STATEMENT: This study shows the potential of computed high-resolution high-sensitivity diffusion-weighted magnetic resonance imaging for solid lesion detection in pancreatic intraductal papillary mucinous neoplasia (IPMN). The technique may enable early cancer detection in patients under surveillance. KEY POINTS: • Computed high-b-value diffusion-weighted imaging (cDWI) may improve the detection and classification of intraductal papillary mucinous neoplasms (IPMN) of the pancreas. • cDWI calculated from high-resolution imaging increases diagnostic precision compared to cDWI calculated from conventional-resolution imaging. • cDWI has the potential to strengthen the role of MRI for screening and surveillance of IPMN, particularly in view of the rising incidence of IPMNs combined with now more conservative therapeutic approaches.


Assuntos
Neoplasias Intraductais Pancreáticas , Neoplasias Pancreáticas , Humanos , Estudos Retrospectivos , Neoplasias Pancreáticas/diagnóstico por imagem , Razão Sinal-Ruído , Imagem de Difusão por Ressonância Magnética/métodos , Pâncreas
10.
Crit Care ; 27(1): 201, 2023 05 26.
Artigo em Inglês | MEDLINE | ID: mdl-37237287

RESUMO

BACKGROUND: A quantitative assessment of pulmonary edema is important because the clinical severity can range from mild impairment to life threatening. A quantitative surrogate measure, although invasive, for pulmonary edema is the extravascular lung water index (EVLWI) extracted from the transpulmonary thermodilution (TPTD). Severity of edema from chest X-rays, to date is based on the subjective classification of radiologists. In this work, we use machine learning to quantitatively predict the severity of pulmonary edema from chest radiography. METHODS: We retrospectively included 471 X-rays from 431 patients who underwent chest radiography and TPTD measurement within 24 h at our intensive care unit. The EVLWI extracted from the TPTD was used as a quantitative measure for pulmonary edema. We used a deep learning approach and binned the data into two, three, four and five classes increasing the resolution of the EVLWI prediction from the X-rays. RESULTS: The accuracy, area under the receiver operating characteristic curve (AUROC) and Mathews correlation coefficient (MCC) in the binary classification models (EVLWI < 15, ≥ 15) were 0.93 (accuracy), 0.98 (AUROC) and 0.86(MCC). In the three multiclass models, the accuracy ranged between 0.90 and 0.95, the AUROC between 0.97 and 0.99 and the MCC between 0.86 and 0.92. CONCLUSION: Deep learning can quantify pulmonary edema as measured by EVLWI with high accuracy.


Assuntos
Aprendizado Profundo , Edema Pulmonar , Humanos , Edema Pulmonar/diagnóstico por imagem , Edema Pulmonar/etiologia , Raios X , Estudos Retrospectivos , Água Extravascular Pulmonar/diagnóstico por imagem , Radiografia , Termodiluição
11.
Eur J Epidemiol ; 38(5): 573-586, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37017830

RESUMO

Treatment concepts in oncology are becoming increasingly personalized and diverse. Successively, changes in standards of care mandate continuous monitoring of patient pathways and clinical outcomes based on large, representative real-world data. The German Cancer Consortium's (DKTK) Clinical Communication Platform (CCP) provides such opportunity. Connecting fourteen university hospital-based cancer centers, the CCP relies on a federated IT-infrastructure sourcing data from facility-based cancer registry units and biobanks. Federated analyses resulted in a cohort of 600,915 patients, out of which 232,991 were incident since 2013 and for which a comprehensive documentation is available. Next to demographic data (i.e., age at diagnosis: 2.0% 0-20 years, 8.3% 21-40 years, 30.9% 41-60 years, 50.1% 61-80 years, 8.8% 81+ years; and gender: 45.2% female, 54.7% male, 0.1% other) and diagnoses (five most frequent tumor origins: 22,523 prostate, 18,409 breast, 15,575 lung, 13,964 skin/malignant melanoma, 9005 brain), the cohort dataset contains information about therapeutic interventions and response assessments and is connected to 287,883 liquid and tissue biosamples. Focusing on diagnoses and therapy-sequences, showcase analyses of diagnosis-specific sub-cohorts (pancreas, larynx, kidney, thyroid gland) demonstrate the analytical opportunities offered by the cohort's data. Due to its data granularity and size, the cohort is a potential catalyst for translational cancer research. It provides rapid access to comprehensive patient groups and may improve the understanding of the clinical course of various (even rare) malignancies. Therefore, the cohort may serve as a decisions-making tool for clinical trial design and contributes to the evaluation of scientific findings under real-world conditions.


Assuntos
Neoplasias , Adolescente , Adulto , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Adulto Jovem , Neoplasias/diagnóstico , Neoplasias/epidemiologia , Neoplasias/terapia , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes
12.
MAGMA ; 36(6): 957-974, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37436611

RESUMO

OBJECTIVES: Development of a protocol for validation and quality assurance of filter-exchange imaging (FEXI) pulse sequences with well-defined and reproducible phantoms. MATERIALS AND METHODS: A FEXI pulse sequence was implemented on a 7 T preclinical MRI scanner. Six experiments in three different test categories were established for sequence validation, demonstration of the reproducibility of phantoms and the measurement of induced changes in the apparent exchange rate (AXR). First, an ice-water phantom was used to investigate the consistency of apparent diffusion coefficient (ADC) measurements with different diffusion filters. Second, yeast cell phantoms were utilized to validate the determination of the AXR in terms of repeatability (same phantom and session), reproducibility (separate but comparable phantoms in different sessions) and directionality of diffusion encodings. Third, the yeast cell phantoms were, furthermore, used to assess potential AXR bias because of altered cell density and temperature. In addition, a treatment experiment with aquaporin inhibitors was performed to evaluate the influence of these compounds on the cell membrane permeability in yeast cells. RESULTS: FEXI-based ADC measurements of an ice-water phantom were performed for three different filter strengths, showed good agreement with the literature value of 1.099 × 10-3 mm2/s and had a maximum coefficient of variation (CV) of 0.55% within the individual filter strengths. AXR estimation in a single yeast cell phantom and imaging session with five repetitions resulted in an overall mean value of (1.49 ± 0.05) s-1 and a CV of 3.4% between the chosen regions of interest. For three separately prepared phantoms, AXR measurements resulted in a mean value of (1.50 ± 0.04) s-1 and a CV of 2.7% across the three phantoms, demonstrating high reproducibility. Across three orthogonal diffusion directions, a mean value of (1.57 ± 0.03) s-1 with a CV of 1.9% was detected, consistent with isotropy of AXR in yeast cells. Temperature and AXR were linearly correlated (R2 = 0.99) and an activation energy EA of 37.7 kJ/mol was determined by Arrhenius plot. Furthermore, a negative correlation was found between cell density (as determined by the reference ADC/fe) and AXR (R2 = 0.95). The treatment experiment resulted in significantly decreased AXR values at different temperatures in the treated sample compared to the untreated control indicating an inhibiting effect. CONCLUSIONS: Using ice-water and yeast cell-based phantoms, a protocol for the validation of FEXI pulse sequences was established for the assessment of stability, repeatability, reproducibility and directionality. In addition, a strong dependence of AXR on cell density and temperature was shown. As AXR is an emerging novel imaging biomarker, the suggested protocol will be useful for quality assurance of AXR measurements within a study and potentially across multiple sites.


Assuntos
Gelo , Saccharomyces cerevisiae , Reprodutibilidade dos Testes , Imagem de Difusão por Ressonância Magnética/métodos , Água , Imagens de Fantasmas
13.
Ultraschall Med ; 44(5): e248-e256, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36646113

RESUMO

PURPOSE: This prospective two-centre study investigated localisation-dependent lesion patterns in COVID-19 with standard lung ultrasonography (LUS) and their relationship with thoracic computed tomography (CT) and clinical parameters. MATERIALS AND METHODS: Between April 2020 and April 2021, 52 SARS-CoV-2-positive patients in two hospitals were examined by means of LUS for "B-lines", fragmented pleura, consolidation and air bronchogram in 12 lung regions and for pleural effusions. A newly developed LUS score based on the number of features present was correlated with clinical parameters (respiration, laboratory parameters) and the CT and analysed with respect to the 30- and 60-day outcome. All patients were offered an outpatient LUS follow-up. RESULTS: The LUS and CT showed a bilateral, partially posteriorly accentuated lesion distribution pattern. 294/323 (91%) of CT-detected lesions were pleural. The LUS score showed an association with respiratory status and C-reactive protein; the correlation with the CT score was weak (Spearman's rho = 0.339, p < 0.001). High LUS scores on admission were also observed in patients who were discharged within 30 days. LUS during follow-up showed predominantly declining LUS scores. CONCLUSION: The LUS score reflected the clinical condition of the patients. No conclusion could be made on the prognostic value of the LUS, because of the low event rate. The LUS and CT score showed no sufficient correlation. This is probably due to different physical principles, which is why LUS could be of complementary value.

14.
Gastroenterology ; 161(1): 318-332.e9, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33819482

RESUMO

BACKGROUND & AIMS: The existence of different subtypes of pancreatic ductal adenocarcinoma (PDAC) and their correlation with patient outcome have shifted the emphasis on patient classification for better decision-making algorithms and personalized therapy. The contribution of mechanisms regulating the cancer stem cell (CSC) population in different subtypes remains unknown. METHODS: Using RNA-seq, we identified B-cell CLL/lymphoma 3 (BCL3), an atypical nf-κb signaling member, as differing in pancreatic CSCs. To determine the biological consequences of BCL3 silencing in vivo and in vitro, we generated bcl3-deficient preclinical mouse models as well as murine cell lines and correlated our findings with human cell lines, PDX models, and 2 independent patient cohorts. We assessed the correlation of bcl3 expression pattern with clinical parameters and subtypes. RESULTS: Bcl3 was significantly down-regulated in human CSCs. Recapitulating this phenotype in preclinical mouse models of PDAC via BCL3 genetic knockout enhanced tumor burden, metastasis, epithelial to mesenchymal transition, and reduced overall survival. Fluorescence-activated cell sorting analyses, together with oxygen consumption, sphere formation, and tumorigenicity assays, all indicated that BCL3 loss resulted in CSC compartment expansion promoting cellular dedifferentiation. Overexpression of BCL3 in human PDXs diminished tumor growth by significantly reducing the CSC population and promoting differentiation. Human PDACs with low BCL3 expression correlated with increased metastasis, and BCL3-negative tumors correlated with lower survival and nonclassical subtypes. CONCLUSIONS: We demonstrate that bcl3 impacts pancreatic carcinogenesis by restraining CSC expansion and by curtailing an aggressive and metastatic tumor burden in PDAC across species. Levels of BCL3 expression are a useful stratification marker for predicting subtype characterization in PDAC, thereby allowing for personalized therapeutic approaches.


Assuntos
Proteína 3 do Linfoma de Células B/metabolismo , Carcinoma Ductal Pancreático/metabolismo , Células-Tronco Neoplásicas/metabolismo , Neoplasias Pancreáticas/metabolismo , Animais , Proteína 3 do Linfoma de Células B/genética , Carcinoma Ductal Pancreático/genética , Carcinoma Ductal Pancreático/secundário , Diferenciação Celular , Linhagem Celular Tumoral , Movimento Celular , Proliferação de Células , Metabolismo Energético , Regulação Neoplásica da Expressão Gênica , Humanos , Camundongos Endogâmicos C57BL , Camundongos Knockout , Camundongos Nus , Invasividade Neoplásica , Células-Tronco Neoplásicas/patologia , Neoplasias Pancreáticas/genética , Neoplasias Pancreáticas/patologia , Transdução de Sinais , Carga Tumoral , Células Tumorais Cultivadas
15.
Eur J Nucl Med Mol Imaging ; 49(4): 1157-1165, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34651225

RESUMO

BACKGROUND: Transpathology highlights the interpretation of the underlying physiology behind molecular imaging. However, it remains challenging due to the discrepancies between in vivo and in vitro measurements and difficulties of precise co-registration between trans-scaled images. This study aims to develop a multimodal intravital molecular imaging (MIMI) system as a tool for in vivo tumour transpathology investigation. METHODS: The proposed MIMI system integrates high-resolution positron imaging, magnetic resonance imaging (MRI) and microscopic imaging on a dorsal skin window chamber on an athymic nude rat. The window chamber frame was designed to be compatible with multimodal imaging and its fiducial markers were customized for precise physical alignment among modalities. The co-registration accuracy was evaluated based on phantoms with thin catheters. For proof of concept, tumour models of the human colorectal adenocarcinoma cell line HT-29 were imaged. The tissue within the window chamber was sectioned, fixed and haematoxylin-eosin (HE) stained for comparison with multimodal in vivo imaging. RESULTS: The final MIMI system had a maximum field of view (FOV) of 18 mm × 18 mm. Using the fiducial markers and the tubing phantom, the co-registration errors are 0.18 ± 0.27 mm between MRI and positron imaging, 0.19 ± 0.22 mm between positron imaging and microscopic imaging and 0.15 ± 0.27 mm between MRI and microscopic imaging. A pilot test demonstrated that the MIMI system provides an integrative visualization of the tumour anatomy, vasculatures and metabolism of the in vivo tumour microenvironment, which was consistent with ex vivo pathology. CONCLUSIONS: The established multimodal intravital imaging system provided a co-registered in vivo platform for trans-scale and transparent investigation of the underlying pathology behind imaging, which has the potential to enhance the translation of molecular imaging.


Assuntos
Imageamento por Ressonância Magnética , Neoplasias , Humanos , Microscopia Intravital , Imageamento por Ressonância Magnética/métodos , Imagem Molecular , Neoplasias/diagnóstico por imagem , Imagens de Fantasmas , Microambiente Tumoral
16.
Eur J Nucl Med Mol Imaging ; 50(1): 115-129, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36074156

RESUMO

PURPOSE: Pancreatic ductal adenocarcinoma (PDAC) is a molecularly heterogeneous tumor entity with no clinically established imaging biomarkers. We hypothesize that tumor morphology and physiology, including vascularity and perfusion, show variations that can be detected by differences in contrast agent (CA) accumulation measured non-invasively. This work seeks to establish imaging biomarkers for tumor stratification and therapy response monitoring in PDAC, based on this hypothesis. METHODS AND MATERIALS: Regional CA accumulation in PDAC was correlated with tumor vascularization, stroma content, and tumor cellularity in murine and human subjects. Changes in CA distribution in response to gemcitabine (GEM) were monitored longitudinally with computed tomography (CT) Hounsfield Units ratio (HUr) of tumor to the aorta or with magnetic resonance imaging (MRI) ΔR1 area under the curve at 60 s tumor-to-muscle ratio (AUC60r). Tissue analyses were performed on co-registered samples, including endothelial cell proliferation and cisplatin tissue deposition as a surrogate of chemotherapy delivery. RESULTS: Tumor cell poor, stroma-rich regions exhibited high CA accumulation both in human (meanHUr 0.64 vs. 0.34, p < 0.001) and mouse PDAC (meanAUC60r 2.0 vs. 1.1, p < 0.001). Compared to the baseline, in vivo CA accumulation decreased specifically in response to GEM treatment in a subset of human (HUr -18%) and mouse (AUC60r -36%) tumors. Ex vivo analyses of mPDAC showed reduced cisplatin delivery (GEM: 0.92 ± 0.5 mg/g, vs. vehicle: 3.1 ± 1.5 mg/g, p = 0.004) and diminished endothelial cell proliferation (GEM: 22.3% vs. vehicle: 30.9%, p = 0.002) upon GEM administration. CONCLUSION: In PDAC, CA accumulation, which is related to tumor vascularization and perfusion, inversely correlates with tumor cellularity. The standard of care GEM treatment results in decreased CA accumulation, which impedes drug delivery. Further investigation is warranted into potentially detrimental effects of GEM in combinatorial therapy regimens.


Assuntos
Carcinoma Ductal Pancreático , Neoplasias Pancreáticas , Humanos , Camundongos , Animais , Cisplatino/uso terapêutico , Ensaios Antitumorais Modelo de Xenoenxerto , Carcinoma Ductal Pancreático/diagnóstico por imagem , Carcinoma Ductal Pancreático/tratamento farmacológico , Carcinoma Ductal Pancreático/patologia , Neoplasias Pancreáticas/diagnóstico por imagem , Neoplasias Pancreáticas/tratamento farmacológico , Neoplasias Pancreáticas/patologia , Neovascularização Patológica/diagnóstico por imagem , Neovascularização Patológica/tratamento farmacológico , Biomarcadores , Tomografia Computadorizada por Raios X , Imageamento por Ressonância Magnética , Tomografia , Linhagem Celular Tumoral , Gencitabina , Neoplasias Pancreáticas
17.
Eur Radiol ; 32(3): 1465-1474, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34687347

RESUMO

OBJECTIVES: To determine the accuracy of an artificial neural network (ANN) for fully automated detection of the presence and phase of iodinated contrast agent in routine abdominal multidetector computed tomography (MDCT) scans and evaluate the effect of contrast correction for osteoporosis screening. METHODS: This HIPPA-compliant study retrospectively included 579 MDCT scans in 193 patients (62.4 ± 14.6 years, 48 women). Three different ANN models (2D DenseNet with random slice selection, 2D DenseNet with anatomy-guided slice selection, 3D DenseNet) were trained in 462 MDCT scans of 154 patients (threefold cross-validation), who underwent triphasic CT. All ANN models were tested in 117 unseen triphasic scans of 39 patients, as well as in a public MDCT dataset containing 311 patients. In the triphasic test scans, trabecular volumetric bone mineral density (BMD) was calculated using a fully automated pipeline. Root-mean-square errors (RMSE) of BMD measurements with and without correction for contrast application were calculated in comparison to nonenhanced (NE) scans. RESULTS: The 2D DenseNet with anatomy-guided slice selection outperformed the competing models and achieved an F1 score of 0.98 and an accuracy of 98.3% in the test set (public dataset: F1 score 0.93; accuracy 94.2%). Application of contrast agent resulted in significant BMD biases (all p < .001; portal-venous (PV): RMSE 18.7 mg/ml, mean difference 17.5 mg/ml; arterial (AR): RMSE 6.92 mg/ml, mean difference 5.68 mg/ml). After the fully automated correction, this bias was no longer significant (p > .05; PV: RMSE 9.45 mg/ml, mean difference 1.28 mg/ml; AR: RMSE 3.98 mg/ml, mean difference 0.94 mg/ml). CONCLUSION: Automatic detection of the contrast phase in multicenter CT data was achieved with high accuracy, minimizing the contrast-induced error in BMD measurements. KEY POINTS: • A 2D DenseNet with anatomy-guided slice selection achieved an F1 score of 0.98 and an accuracy of 98.3% in the test set. In a public dataset, an F1 score of 0.93 and an accuracy of 94.2% were obtained. • Automated adjustment for contrast injection improved the accuracy of lumbar bone mineral density measurements (RMSE 18.7 mg/ml vs. 9.45 mg/ml respectively, in the portal-venous phase). • An artificial neural network can reliably reveal the presence and phase of iodinated contrast agent in multidetector CT scans ( https://github.com/ferchonavarro/anatomy_guided_contrast_c ). This allows minimizing the contrast-induced error in opportunistic bone mineral density measurements.


Assuntos
Densidade Óssea , Osteoporose , Feminino , Humanos , Tomografia Computadorizada Multidetectores , Redes Neurais de Computação , Osteoporose/diagnóstico por imagem , Estudos Retrospectivos
18.
Eur Radiol ; 32(9): 6207-6214, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35384459

RESUMO

OBJECTIVES: To determine the correlation between cervicothoracic and lumbar volumetric bone mineral density (vBMD) in an average cohort of adults and to identify specific diagnostic thresholds for the cervicothoracic spine on the individual subject level. METHODS: In this HIPPA-compliant study, we retrospectively included 260 patients (59.7 ± 18.3 years, 105 women), who received a contrast-enhanced or non-contrast-enhanced CT scan. vBMD was extracted using an automated pipeline ( https://anduin.bonescreen.de ). The association of vBMD between each vertebra spanning C2-T12 and the averaged values at the lumbar spine (L1-L3) was analyzed before and after semiquantitative assessment of fracture status and degeneration, and respective vertebra-specific cut-off values for osteoporosis were calculated using linear regression. RESULTS: In both women and men, trabecular vBMD decreased with age in the cervical, thoracic, and lumbar regions. vBMD values of cervicothoracic vertebrae showed strong correlations with lumbar vertebrae (L1-L3), with a median Pearson value of r = 0.87 (range: rC2 = 0.76 to rT12 = 0.96). The correlation coefficients were significantly lower (p < 0.0001) without excluding fractured and degenerated vertebrae, median r = 0.82 (range: rC2 = 0.69 to rT12 = 0.93). Respective cut-off values for osteoporosis peaked at C4 (209.2 mg/ml) and decreased to 83.8 mg/ml at T12. CONCLUSION: Our data show a high correlation between clinically used mean L1-L3 values and vBMD values elsewhere in the spine, independent of age. The proposed cut-off values for the cervicothoracic spine therefore may allow the determination of low bone mass even in clinical cases where only parts of the spine are imaged. KEY POINTS: vBMD of all cervicothoracic vertebrae showed strong correlation with lumbar vertebrae (L1-L3), with a median Pearson's correlation coefficient of r = 0.87 (range: rC2 = 0.76 to rT12 = 0.96). The correlation coefficients were significantly lower (p < 0.0001) without excluding fractured and moderate to severely degenerated vertebrae, median r = 0.82 (range: rC2 = 0.69 to rT12 = 0.93). We postulate that trabecular vBMD < 200 mg/ml for the cervical spine and < 100 mg/ml for the thoracic spine are strong indicators of osteoporosis, similar to < 80 mg/ml at the lumbar spine.


Assuntos
Doenças Ósseas Metabólicas , Fraturas Ósseas , Vértebras Lombares , Osteoporose , Absorciometria de Fóton/métodos , Adulto , Densidade Óssea , Doenças Ósseas Metabólicas/diagnóstico por imagem , Feminino , Humanos , Vértebras Lombares/diagnóstico por imagem , Região Lombossacral , Masculino , Osteoporose/diagnóstico por imagem , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos
19.
MAGMA ; 35(5): 827-841, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34894335

RESUMO

OBJECTIVE : To experimentally characterize the effectiveness of a gradient nonlinearity correction method in removing ADC bias for different motion-compensated diffusion encoding waveforms. METHODS: The diffusion encoding waveforms used were the standard monopolar Stejskal-Tanner pulsed gradient spin echo (pgse) waveform, the symmetric bipolar velocity-compensated waveform (sym-vc), the asymmetric bipolar velocity-compensated waveform (asym-vc) and the asymmetric bipolar partial velocity-compensated waveform (asym-pvc). The effectiveness of the gradient nonlinearity correction method using the spherical harmonic expansion of the gradient coil field was tested with the aforementioned waveforms in a phantom and in four healthy subjects. RESULTS: The gradient nonlinearity correction method reduced the ADC bias in the phantom experiments for all used waveforms. The range of the ADC values over a distance of ± 67.2 mm from isocenter reduced from 1.29 × 10-4 to 0.32 × 10-4 mm2/s for pgse, 1.04 × 10-4 to 0.22 × 10-4 mm2/s for sym-vc, 1.22 × 10-4 to 0.24 × 10-4 mm2/s for asym-vc and 1.07 × 10-4 to 0.11 × 10-4 mm2/s for asym-pvc. The in vivo results showed that ADC overestimation due to motion or bright vessels can be increased even further by the gradient nonlinearity correction. CONCLUSION: The investigated gradient nonlinearity correction method can be used effectively with various motion-compensated diffusion encoding waveforms. In coronal liver DWI, ADC errors caused by motion and residual vessel signal can be increased even further by the gradient nonlinearity correction.


Assuntos
Imagem de Difusão por Ressonância Magnética , Processamento de Imagem Assistida por Computador , Humanos , Imagem de Difusão por Ressonância Magnética/métodos , Processamento de Imagem Assistida por Computador/métodos , Fígado/diagnóstico por imagem , Movimento (Física)
20.
Entropy (Basel) ; 24(5)2022 May 16.
Artigo em Inglês | MEDLINE | ID: mdl-35626597

RESUMO

The increasing prevalence of large-scale data collection in modern society represents a potential threat to individual privacy. Addressing this threat, for example through privacy-enhancing technologies (PETs), requires a rigorous definition of what exactly is being protected, that is, of privacy itself. In this work, we formulate an axiomatic definition of privacy based on quantifiable and irreducible information flows. Our definition synthesizes prior work from the domain of social science with a contemporary understanding of PETs such as differential privacy (DP). Our work highlights the fact that the inevitable difficulties of protecting privacy in practice are fundamentally information-theoretic. Moreover, it enables quantitative reasoning about PETs based on what they are protecting, thus fostering objective policy discourse about their societal implementation.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA