Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Appl Opt ; 54(33): 9939-48, 2015 Nov 20.
Artigo em Inglês | MEDLINE | ID: mdl-26836561

RESUMO

Large-aperture ultrashort ultrahigh intensity laser systems are able to achieve unprecedented super-high peak power. However, output power from a single laser channel is not high enough for some important applications and it is difficult to improve output power from a single laser channel significantly in the near future. Coherent beam combining is a promising method which combines many laser channels to obtain much higher peak power than a single channel. In this work, phase effects of coherent beam combining for large-aperture ultrashort laser systems are investigated theoretically. A series of numerical simulations are presented to obtain the requirements of spatial phase for specific goals and the changing trends of requirements for different pulse durations and number of channels. The influence of wavefront distortion on coherent beam combining is also discussed. Some advice is proposed for improving the performance of combining. In total, this work could help to design a practical large-aperture ultrashort ultrahigh intensity laser system in the future.

2.
Appl Opt ; 51(15): 2941-50, 2012 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-22614597

RESUMO

Aiming at getting the general requirements of the beam combine for ignition scale laser facilities, the analytical expressions including the factors affecting the combine results are derived. The physical meanings of every part are illustrated. Based on these expressions, the effects of the factors, including the beam configuration, piston error, and tip/tilt error, are studied analytically and numerically. The results show that the beam configuration cannot affect the Strehl ratio (SR) of the combined beam, but it influences the FWHM of the main peak and the ratio of the main peak and the side peak. The beam separation should be no more than 1.24 times the individual beam width for the multibeam combine, and be close to the individual beam width for the two-beam combine as much as possible. The piston error can change the characteristics of the combine beam focus, including the peak intensity, the focal spot morphology, the fractional energy contained within a certain area, and the center of mass. For the two-beam combine, a piston error less than 2π/5 rad is suitable, and for the multibeam combine, the standard deviation of the piston error should be no more than 2π/10 rad. The tip/tilt error has a great influence on the combined results. It affects the superposition degree of the focal spots of the combined elements directly. A requirement of 0.5~1 µrad for the standard deviation of the tip/tilt error is adequate.

3.
Sci Rep ; 7(1): 12929, 2017 10 10.
Artigo em Inglês | MEDLINE | ID: mdl-29018232

RESUMO

V/Sc multilayer is experimentally demonstrated for the first time as a high reflectance mirror for the soft X-ray water window region. It primarily works at above the Sc-L edge (λ = 3.11 nm) under near normal incidence while a second peak appears at above the V-L edge (λ = 2.42 nm) under grazing incidence. The V/Sc multilayer fabricated with a d-spacing of 1.59 nm and 30 bilayers has a smaller interface width (σ = 0.27 and 0.32 nm) than the conventional used Cr/Sc (σ = 0.28 and 0.47 nm). For V/Sc multilayer with 30 bilayers, the introduction of B4C barrier layers has little improvement on the interface structure. As the number of bilayers increasing to 400, the growth morphology and microstructure of the V/Sc layers evolves with slightly increased crystallization. Nevertheless, the surface roughness remains to be 0.25 nm. A maximum soft X-ray reflectance of 18.4% is measured at λ = 3.129 nm at 9° off-normal incidence using the 400-bilayers V/Sc multilayer. According to the fitted model, an s-polarization reflectance of 5.2% can also be expected at λ = 2.425 nm under 40° incidence. Based on the promising experimental results, further improvement of the reflectance can be achieved by using a more stable deposition system, exploring different interface engineering methods and so on.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA