Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Tipo de documento
Ano de publicação
Intervalo de ano de publicação
1.
Br J Anaesth ; 121(5): 1041-1051, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30336848

RESUMO

BACKGROUND: Cardiopulmonary bypass (CPB) during cardiac surgery impairs microcirculatory perfusion and is paralleled by vascular leakage. The endothelial angiopoietin/Tie2 system controls microvascular leakage. This study investigated whether targeting Tie2 with the angiopoietin-1 mimetic vasculotide reduces vascular leakage and preserves microcirculatory perfusion in a rat CPB model. METHODS: Rats were subjected to 75 min of CPB after treatment with vasculotide or phosphate buffered solution as control or underwent a sham procedure. Microcirculatory perfusion and leakage were assessed with intravital microscopy (n=10 per group) and Evans blue dye extravasation (n=13 per group), respectively. Angiopoietin-1, -2, and Tie2 protein and gene expression were determined in plasma, kidney, and lung. RESULTS: CPB immediately impaired microcirculatory perfusion [5 (4-8) vs 10 (7-12) vessels per recording, P=0.002] in untreated CPB rats compared with sham, which persisted after weaning from CPB. CPB increased circulating angiopoeietin-1, -2, and soluble Tie2 concentrations and reduced Tie2 messenger ribonucleic acid (mRNA) expression in kidney and lung. Moreover, CPB increased Evans blue dye leakage in kidney [12 (8-25) vs 7 (1-12) µg g-1, P=0.04] and lung [and 23 (13-60) vs 6 (4-16) µg g-1, P=0.001] compared with sham. Vasculotide treatment preserved microcirculatory perfusion during and after CPB. Moreover, vasculotide treatment reduced Evans blue dye extravasation in lung compared with CPB control [18 (6-28) µg g-1vs 23 (13-60) µg g-1, P=0.04], but not in kidney [10 (3-23) vs 12 (8-25) µg g-1, P=0.38]. Vasculotide did not affect circulating or mRNA expression of angiopoietin-1, -2, and Tie2 concentrations compared with untreated CPB controls. CONCLUSIONS: Treatment with the angiopoietin-1 mimetic vasculotide reduced pulmonary vascular leakage and preserved microcirculatory perfusion during CPB in a rat model.


Assuntos
Angiopoietina-1/uso terapêutico , Ponte Cardiopulmonar/efeitos adversos , Fragmentos de Peptídeos/uso terapêutico , Circulação Pulmonar/efeitos dos fármacos , Angiopoietina-1/biossíntese , Angiopoietina-1/genética , Angiopoietina-2/biossíntese , Angiopoietina-2/genética , Animais , Capilares/efeitos dos fármacos , Expressão Gênica/efeitos dos fármacos , Masculino , Microcirculação/efeitos dos fármacos , Ratos , Ratos Wistar , Receptor TIE-2/biossíntese , Receptor TIE-2/genética , Receptor TIE-2/metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA