RESUMO
The study aims to define how imaging findings, patient demographics, patient-provider interactions, and health care practices may affect a woman's decision to follow-up in the setting of a BI-RADS Category 3. A total of 398 women from the University of Arizona Breast Imaging Center with a BI-RADS Category 3 assessment for mammography and/or ultrasound findings were evaluated between February 2012 and June 2014. Demographic information was analyzed for all patients, regardless of follow-up. Women who returned for follow-up within the recommended time period were given one survey at the time of their follow-up appointment, and women who returned for follow-up, but later than recommended, were given a separate survey to complete. Age, palpability of a lesion, and menopause status were related to follow-up. Self-rated general health was the only factor found to be associated with the decision to follow-up on time. The majority of patients who followed up on time reported that mailed reminder cards were the primary practice that prompted follow-up. Of patients who followed up later than recommended, the major reason was "no time." The findings suggest that additional counseling regarding the benefits of short-interval imaging follow-up might be advantageous for patients.
Assuntos
Assistência ao Convalescente/estatística & dados numéricos , Neoplasias da Mama/patologia , Cooperação do Paciente/estatística & dados numéricos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Neoplasias da Mama/diagnóstico por imagem , Criança , Feminino , Seguimentos , Inquéritos Epidemiológicos , Humanos , Mamografia , Menopausa , Pessoa de Meia-Idade , Cooperação do Paciente/psicologia , Relações Médico-Paciente , Fatores de Tempo , Adulto JovemRESUMO
Background An important difficulty regarding the Breast Imaging Reporting and Data System (BI-RADS) category 3 assessment is the need for extensive diagnostic workup and an additional 6-month follow-up study. Purpose To evaluate the feasibility of the BI-RADS category 3 assessments at opportunistic screening. Material and Methods Mammography charts of 9062 screening patients in a major teaching hospital situated in an urban setting of a developing country were evaluated retrospectively (1997-2010). BI-RADS category 3 patients, called for a 6-month follow-up, which comprised a single-view spot or magnification mammogram. The length of follow-up period, compliance to periodic mammographic surveillance, cancer detection rate, and negative predictive values of category 3 assessments were calculated. Results Of the screened population, 9.2% were assigned BI-RADS category 3, and 31.2% of these cases were lost to follow-up. The mean follow-up period for 606 patients was 36.9 months. The negative predictive values for 6-month, 12-month, and final control studies were 90.9%, 87.5%, and 100%, respectively. Patient compliance for 6 months, 12 months, and any control evaluations beyond 12 months was low (50.0%, 29.8%, and 47.5%, respectively). Cancer detection rate was 0.8%. Conclusion Results of the study supports the feasibility of the BI-RADS category 3 assessments at opportunistic screening without any additional diagnostic workup. The practice of category 3 assessment following screening mammograms may be a more cost-effective method for developing countries with high recall rates and low resources in eliminating the maximum risk with minimum cost within the limits of available resources.
Assuntos
Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/epidemiologia , Competência Clínica/estatística & dados numéricos , Países em Desenvolvimento/estatística & dados numéricos , Detecção Precoce de Câncer/estatística & dados numéricos , Mamografia/estatística & dados numéricos , Adulto , Idoso , Idoso de 80 Anos ou mais , Neoplasias da Mama/classificação , Feminino , Humanos , Pessoa de Meia-Idade , Cooperação do Paciente/estatística & dados numéricos , Prevalência , Prognóstico , Reprodutibilidade dos Testes , Medição de Risco/métodos , Sensibilidade e Especificidade , Turquia/epidemiologiaRESUMO
The aim of our study was to verify the utility of surveillance ultrasound (US) using real-time virtual sonography (RVS)--to coordinate present US images with past US images reconstructed from previously acquired US volume data using an image fusion technique--for short-interval follow-up of Breast Imaging-Reporting and Data System (BI-RADS) category 3 mass lesions. We enrolled 20 women (23 lesions) with more than 24 mo of follow-up after classification as BI-RADS category 3 during initial US. US surveillance was scheduled at 6, 12 and 24 mo. Measurement of the target lesion diameter was performed after the probe was adjusted to include the maximum diameter of a past US image at each visit. RVS was technically successful in 100% of patients. All target lesions were detected, including two iso-echoic lesions. The mean target lesion diameters at baseline and at 6, 12 and 24 mo were 8.2 ± 4.2, 8.4 ± 4.5, 8.1 ± 4.5 and 8.3 ± 5.0 mm, respectively (p = 0.785). Our results suggest that RVS is a reproducible, operator-independent technique for comparison of US images of BI-RADS category 3 mass lesions obtained at different time points.