Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 78
Filtrar
1.
Microsc Microanal ; 29(3): 1087-1095, 2023 Jun 09.
Artigo em Inglês | MEDLINE | ID: mdl-37749690

RESUMO

Material properties strongly depend on the nature and concentration of defects. Characterizing these features may require nano- to atomic-scale resolution to establish structure-property relationships. 4D-STEM, a technique where diffraction patterns are acquired at a grid of points on the sample, provides a versatile method for highlighting defects. Computational analysis of the diffraction patterns with virtual detectors produces images that can map material properties. Here, using multislice simulations, we explore different virtual detectors that can be applied to the diffraction patterns that go beyond the binary response functions that are possible using ordinary STEM detectors. Using graphene and lead titanate as model systems, we investigate the application of virtual detectors to study local order and in particular defects. We find that using a small convergence angle with a rotationally varying detector most efficiently highlights defect signals. With experimental graphene data, we demonstrate the effectiveness of these detectors in characterizing atomic features, including vacancies, as suggested in simulations. Phase and amplitude modification of the electron beam provides another process handle to change image contrast in a 4D-STEM experiment. We demonstrate how tailored electron beams can enhance signals from short-range order and how a vortex beam can be used to characterize local symmetry.

2.
Microsc Microanal ; 29(6): 1950-1960, 2023 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-37851063

RESUMO

In a scanning transmission electron microscope (STEM), producing a high-resolution image generally requires an electron beam focused to the smallest point possible. However, the magnetic lenses used to focus the beam are unavoidably imperfect, introducing aberrations that limit resolution. Modern STEMs overcome this by using hardware aberration correctors comprised of many multipole elements, but these devices are complex, expensive, and can be difficult to tune. We demonstrate a design for an electrostatic phase plate that can act as an aberration corrector. The corrector is comprised of annular segments, each of which is an independent two-terminal device that can apply a constant or ramped phase shift to a portion of the electron beam. We show the improvement in image resolution using an electrostatic corrector. Engineering criteria impose that much of the beam within the probe-forming aperture be blocked by support bars, leading to large probe tails for the corrected probe that sample the specimen beyond the central lobe. We also show how this device can be used to create other STEM beam profiles such as vortex beams and probes with a high degree of phase diversity, which improve information transfer in ptychographic reconstructions.

3.
J Struct Biol ; 214(1): 107827, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34915129

RESUMO

In principle, electron cryo-tomography (cryo-ET) of thin portions of cells provides high-resolution images of the three-dimensional spatial arrangement of all members of the proteome. In practice, however, radiation damage creates a tension between recording images at many different tilt angles, but at correspondingly reduced exposure levels, versus limiting the number of tilt angles in order to improve the signal-to-noise ratio (SNR). Either way, it is challenging to read the available information out at the level of atomic structure. Here, we first review work that explores the optimal strategy for data collection, which currently seems to favor the use of a limited angular range for tilting the sample or even the use of a single image to record the high-resolution information. Looking then to the future, we point to the alternative of so-called "deconvolution microscopy", which may be applied to tilt-series or optically-sectioned, focal series data. Recording data as a focal series has the advantage that little or no translational alignment of frames might be needed, and a three-dimensional reconstruction might require only 2/3 the number of images as does standard tomography. We also point to the unexploited potential of phase plates to increase the contrast, and thus to reduce the electron exposure levels while retaining the ability align and merge the data. In turn, using much lower exposures per image could have the advantage that high-resolution information is retained throughout the full data-set, whether recorded as a tilt series or a focal series of images.


Assuntos
Tomografia com Microscopia Eletrônica , Processamento de Imagem Assistida por Computador , Microscopia Crioeletrônica/métodos , Tomografia com Microscopia Eletrônica/métodos , Processamento de Imagem Assistida por Computador/métodos , Substâncias Macromoleculares/química , Razão Sinal-Ruído
4.
J Microsc ; 288(2): 142-150, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36106606

RESUMO

Fluorescence nanoscopy methods based on the RESOLFT principle, such as beam-scanning STED nanoscopy, require the co-alignment of optical beams for molecular state (on/off) switching and fluorescence excitation. The complexity and stability of the beam alignment can be drastically simplified and improved by using a single-mode fibre as the sole light source for all required laser beams. This in turn then requires a chromatic optical element for shaping the off-switching beam into a focal-plane donut while simultaneously leaving the focal intensity distributions at other wavelengths shaped as regular focal spots. Here we describe novel designs of such so-called 'easySTED phase plates' and provide a rationale how to find the desired spectral signature for combinations of multiple wavelengths.


Assuntos
Luz , Microscopia de Fluorescência/métodos
5.
J Microsc ; 287(1): 45-58, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35438194

RESUMO

Phase plates (PPs) in transmission electron microscopy (TEM) improve the contrast of weakly scattering objects under in-focus imaging conditions. A well-established PP type is the Zernike (Z)PP, which consists of a thin amorphous carbon (aC) film with a microscaled hole in the centre. The mean inner potential of the aC film is exploited to shift the phase of the scattered electrons while the unscattered electrons in the zero-order beam propagate through the hole and remain unaffected. However, the abrupt thickness increase at the hole edge induces an abrupt change of the phase-shift distribution and leads to fringing, that is, intensity oscillations around imaged objects, in TEM images. In this work, we have used focused-ion-beam milling to fabricate ZPPs with abrupt and graded thickness profiles around the centre hole. Depending on the thickness gradient and inner hole radius, graded-ZPP-TEM images of an aC/vacuum interface and bundles of carbon nanotubes (CNTs) show strongly reduced fringing. Image simulations were performed with ZPP-phase-shift distributions derived from measured thickness profiles of graded ZPPs, which show good agreement with the experimental images. Fringing artefacts, that is, intensity oscillations around imaged objects, are strongly reduced for Zernike phase plates with a graded thickness profile around the centre hole. Focused-ion-beam milling is used to fabricate graded Zernike phase plates with specific inner hole radius and thickness gradients. The phase-shift distribution is obtained from measured thickness profiles around the centre hole. Image simulations based on experimentally measured thickness/phase-shift distributions show good agreement with experimental Zernike phase-plate TEM images.

6.
J Struct Biol ; 213(2): 107742, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33971285

RESUMO

Cryo-electron tomography (cryo-ET) is a pivotal imaging technique for studying the structure of pleomorphic enveloped viruses and their interactions with the host at native conditions. Owing to the limited tilting range of samples with a slab geometry, electron tomograms suffer from so-called missing wedge information in Fourier space. In dual-axis cryo-ET, two tomograms reconstructed from orthogonally oriented tilt series are combined into a tomogram with improved resolution as the missing wedge information is reduced to a pyramid. Volta phase plate (VPP) allows to perform in-focus cryo-ET with high contrast transfer at low-resolution frequencies and thus its application may improve the quality of dual-axis tomograms. Here, we compare dual-axis cryo-ET with and without VPP on Ebola virus-like particles to visualize and segment viral and host cell proteins within the membrane-enveloped filamentous particles. Dual-axis VPP cryo-ET reduces the missing wedge information and ray artifacts arising from the weighted back-projection during tomogram reconstruction, thereby minimizing ambiguity in the analysis of crowded environments and facilitating 3D segmentation. We show that dual-axis VPP tomograms provide a comprehensive description of macromolecular organizations such as nucleocapsid assembly states, the distribution of glycoproteins on the viral envelope and asymmetric arrangements of the VP40 layer in non-filamentous regions of virus-like particles. Our data reveal actin filaments within virus-like particles in close proximity to the viral VP40 scaffold, suggesting a direct interaction between VP40 and actin filaments. Dual-axis VPP cryo-ET provides more complete 3D information at high contrast and allows for better interpretation of macromolecule interactions and pleomorphic organizations.


Assuntos
Actinas/química , Microscopia Crioeletrônica/métodos , Ebolavirus/química , Proteínas da Matriz Viral/química , Actinas/metabolismo , Membrana Celular , Ebolavirus/metabolismo , Ebolavirus/ultraestrutura , Tomografia com Microscopia Eletrônica/métodos , Células HEK293 , Doença pelo Vírus Ebola/patologia , Doença pelo Vírus Ebola/virologia , Interações Hospedeiro-Patógeno , Humanos , Imageamento Tridimensional , Nucleocapsídeo/química , Proteínas da Matriz Viral/metabolismo
7.
J Synchrotron Radiat ; 28(Pt 5): 1343-1356, 2021 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-34475283

RESUMO

Imaging of biomolecules by ionizing radiation, such as electrons, causes radiation damage which introduces structural and compositional changes of the specimen. The total number of high-energy electrons per surface area that can be used for imaging in cryogenic electron microscopy (cryo-EM) is severely restricted due to radiation damage, resulting in low signal-to-noise ratios (SNR). High resolution details are dampened by the transfer function of the microscope and detector, and are the first to be lost as radiation damage alters the individual molecules which are presumed to be identical during averaging. As a consequence, radiation damage puts a limit on the particle size and sample heterogeneity with which electron microscopy (EM) can deal. Since a transmission EM (TEM) image is formed from the scattering process of the electron by the specimen interaction potential, radiation damage is inevitable. However, we can aim to maximize the information transfer for a given dose and increase the SNR by finding alternatives to the conventional phase-contrast cryo-EM techniques. Here some alternative transmission electron microscopy techniques are reviewed, including phase plate, multi-pass transmission electron microscopy, off-axis holography, ptychography and a quantum sorter. Their prospects for providing more or complementary structural information within the limited lifetime of the sample are discussed.


Assuntos
Microscopia Crioeletrônica/métodos , Substâncias Macromoleculares/ultraestrutura , Elétrons , Razão Sinal-Ruído , Relação Estrutura-Atividade
8.
J Synchrotron Radiat ; 28(Pt 3): 1030, 2021 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-33950011

RESUMO

A correction in the paper by Seiboth et al. [(2018). J. Synchrotron Rad. 25, 108-115] is made.

9.
J Struct Biol ; 209(3): 107450, 2020 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-31954841

RESUMO

Troponin is an essential component of striated muscle and it regulates the sliding of actomyosin system in a calcium-dependent manner. Despite its importance, the structure of troponin has been elusive due to its high structural heterogeneity. In this study, we analyzed the 3D structures of murine cardiac thin filaments using a cryo-electron microscope equipped with a Volta phase plate (VPP). Contrast enhancement by a VPP enabled us to reconstruct the entire repeat of the thin filament. We determined the orientation of troponin relative to F-actin and tropomyosin, and characterized the interactions between troponin and tropomyosin. This study provides a structural basis for understanding the molecular mechanism of actomyosin system.


Assuntos
Citoesqueleto de Actina/ultraestrutura , Actinas/ultraestrutura , Músculo Estriado/ultraestrutura , Troponina/ultraestrutura , Actinas/química , Actomiosina/química , Actomiosina/ultraestrutura , Animais , Cálcio , Microscopia Crioeletrônica , Camundongos , Sarcômeros/química , Sarcômeros/ultraestrutura , Tropomiosina/ultraestrutura , Troponina/química
10.
J Synchrotron Radiat ; 27(Pt 5): 1121-1130, 2020 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-32876586

RESUMO

Modern subtractive and additive manufacturing techniques present new avenues for X-ray optics with complex shapes and patterns. Refractive phase plates acting as glasses for X-ray optics have been fabricated, and spherical aberration in refractive X-ray lenses made from beryllium has been successfully corrected. A diamond phase plate made by femtosecond laser ablation was found to improve the Strehl ratio of a lens stack with a numerical aperture (NA) of 0.88 × 10-3 at 8.2 keV from 0.1 to 0.7. A polymer phase plate made by additive printing achieved an increase in the Strehl ratio of a lens stack at 35 keV with NA of 0.18 × 10-3 from 0.15 to 0.89, demonstrating diffraction-limited nanofocusing at high X-ray energies.

11.
Proc Natl Acad Sci U S A ; 114(34): 9110-9115, 2017 08 22.
Artigo em Inglês | MEDLINE | ID: mdl-28739947

RESUMO

Neurotransmitter release is orchestrated by synaptic proteins, such as SNAREs, synaptotagmin, and complexin, but the molecular mechanisms remain unclear. We visualized functionally active synaptic proteins reconstituted into proteoliposomes and their interactions in a native membrane environment by electron cryotomography with a Volta phase plate for improved resolvability. The images revealed individual synaptic proteins and synaptic protein complex densities at prefusion contact sites between membranes. We observed distinct morphologies of individual synaptic proteins and their complexes. The minimal system, consisting of neuronal SNAREs and synaptotagmin-1, produced point and long-contact prefusion states. Morphologies and populations of these states changed as the regulatory factors complexin and Munc13 were added. Complexin increased the membrane separation, along with a higher propensity of point contacts. Further inclusion of the priming factor Munc13 exclusively restricted prefusion states to point contacts, all of which efficiently fused upon Ca2+ triggering. We conclude that synaptic proteins have evolved to limit possible contact site assemblies and morphologies to those that promote fast Ca2+-triggered release.


Assuntos
Proteínas de Fusão de Membrana/metabolismo , Fusão de Membrana , Neurônios/metabolismo , Membranas Sinápticas/metabolismo , Animais , Cálcio/metabolismo , Microscopia Crioeletrônica/métodos , Proteínas de Fusão de Membrana/química , Modelos Moleculares , Proteínas do Tecido Nervoso/química , Proteínas do Tecido Nervoso/metabolismo , Ligação Proteica , Domínios Proteicos , Proteolipídeos/metabolismo , Proteolipídeos/ultraestrutura , Proteínas SNARE/química , Proteínas SNARE/metabolismo , Membranas Sinápticas/ultraestrutura , Vesículas Sinápticas/metabolismo , Vesículas Sinápticas/ultraestrutura , Sinaptotagmina I/química , Sinaptotagmina I/metabolismo
12.
Proc Natl Acad Sci U S A ; 114(17): 4412-4417, 2017 04 25.
Artigo em Inglês | MEDLINE | ID: mdl-28396430

RESUMO

Tripeptidyl peptidase II (TPPII) is a eukaryotic protease acting downstream of the 26S proteasome; it removes tripeptides from the degradation products released by the proteasome. Structural studies in vitro have revealed the basic architecture of TPPII, a two-stranded linear polymer that assembles to form a spindle-shaped complex of ∼6 MDa. Dependent on protein concentration, TPPII has a distinct tendency for polymorphism. Therefore, its structure in vivo has remained unclear. To resolve this issue, we have scrutinized cryo-electron tomograms of rat hippocampal neurons for the occurrence and spatial distribution of TPPII by template matching. The quality of the tomograms recorded with the Volta phase plate enabled a detailed structural analysis of TPPII despite its low abundance. Two different assembly states (36-mers and 32-mers) coexist as well as occasional extended forms with longer strands. A distance analysis of the relative locations of TPPII and 26S proteasomes confirmed the visual impression that these two complexes spatially associate in agreement with TPPII's role in postproteasomal degradation.


Assuntos
Aminopeptidases/metabolismo , Dipeptidil Peptidases e Tripeptidil Peptidases/metabolismo , Neurônios/metabolismo , Complexo de Endopeptidases do Proteassoma/química , Serina Endopeptidases/metabolismo , Aminopeptidases/genética , Animais , Animais Recém-Nascidos , Células Cultivadas , Dipeptidil Peptidases e Tripeptidil Peptidases/genética , Modelos Moleculares , Neurônios/ultraestrutura , Complexo de Endopeptidases do Proteassoma/metabolismo , Ligação Proteica , Conformação Proteica , Ratos , Serina Endopeptidases/genética
13.
J Struct Biol ; 206(2): 225-232, 2019 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-30928614

RESUMO

Volta Phase Plate (VPP) has become an invaluable tool for cryo-EM structural determination of small protein complexes by increasing image contrast. Currently, the standard protocol of VPP usage periodically changes the VPP position to a fresh spot during data collection. Such a protocol was to target the phase shifts to a relatively narrow range (around 90°) based on the observations of increased phase shifts and image blur associated with more images taken with a single VPP position. Here, we report a 2.87 Šresolution structure of apoferritin reconstructed from a dataset collected using only a single position of VPP. The reconstruction resolution and map density features are nearly identical to the reconstruction from the control dataset collected with periodic change of VPP positions. Further experiments have verified that similar results, including a 2.5 Šresolution structure, could be obtained with a full range of phase shifts, different spots of variable phase shift increasing rates, and at different ages of the VPP post-installation. Furthermore, we have found that the phase shifts at low resolutions, probably related to the finite size of the Volta spots, could not be correctly modeled by current CTF model using a constant phase shift at all frequencies. In dataset III, severe beam tilt issue was identified but could be computationally corrected with iterative refinements. The observations in this study may provide new insights into further improvement of both the efficiency and robustness of VPP, and to help turn VPP into a plug-and-play device for high-resolution cryo-EM.


Assuntos
Apoferritinas/química , Microscopia Crioeletrônica/métodos , Coleta de Dados , Conformação Proteica
14.
Sensors (Basel) ; 19(3)2019 Jan 22.
Artigo em Inglês | MEDLINE | ID: mdl-30678200

RESUMO

Printed electronic devices are attracting significant interest due to their versatility and low cost; however, quality control during manufacturing is a significant challenge, preventing the widespread adoption of this promising technology. We show that terahertz (THz) radiation can be used for the in situ inspection of printed electronic devices, as confirmed through a comparison with conventional electrical conductivity methods. Our in situ method consists of printing a simple test pattern exhibiting a distinct signature in the THz range that enables the precise characterization of the static electrical conductivities of the printed ink. We demonstrate that contactless dual-wavelength THz spectroscopy analysis, which requires only a single THz measurement, is more precise and repeatable than the conventional four-point probe conductivity measurement method. Our results open the door to a simple strategy for performing contactless quality control in real time of printed electronic devices at any stage of its production line.

15.
Int J Mol Sci ; 20(4)2019 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-30795505

RESUMO

Heteromeric amino acid transporters (HATs) are protein complexes that catalyze the transport of amino acids across plasma membranes. HATs are composed of two subunits, a heavy and a light subunit, which belong to the solute carrier (SLC) families SLC3 and SLC7. The two subunits are linked by a conserved disulfide bridge. Several human diseases are associated with loss of function or overexpression of specific HATs making them drug targets. The human HAT 4F2hc-LAT2 (SLC3A2-SLC7A8) is specific for the transport of large neutral L-amino acids and specific amino acid-related compounds. Human 4F2hc-LAT2 can be functionally overexpressed in the methylotrophic yeast Pichia pastoris and pure recombinant protein purified. Here we present the first cryo-electron microscopy (cryo-EM) 3D-map of a HAT, i.e., of the human 4F2hc-LAT2 complex. The structure could be determined at ~13 Å resolution using direct electron detector and Volta phase plate technologies. The 3D-map displays two prominent densities of different sizes. The available X-ray structure of the 4F2hc ectodomain fitted nicely into the smaller density revealing the relative position of 4F2hc with respect to LAT2 and the membrane plane.


Assuntos
Proteínas Adaptadoras de Transdução de Sinal/química , Microscopia Crioeletrônica/métodos , Cadeia Pesada da Proteína-1 Reguladora de Fusão/química , Proteínas Adaptadoras de Transdução de Sinal/metabolismo , Microscopia Crioeletrônica/instrumentação , Cadeia Pesada da Proteína-1 Reguladora de Fusão/metabolismo , Humanos , Domínios Proteicos , Multimerização Proteica
16.
J Struct Biol ; 202(3): 191-199, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29337113

RESUMO

A current bottleneck in structure determination of macromolecular complexes by cryo electron microscopy (cryo-EM) is the large amount of data needed to obtain high-resolution 3D reconstructions, including through sorting into different conformations and compositions with advanced image processing. Additionally, it may be difficult to visualize small ligands that bind in sub-stoichiometric levels. Volta phase plates (VPP) introduce a phase shift in the contrast transfer and drastically increase the contrast of the recorded low-dose cryo-EM images while preserving high frequency information. Here we present a comparative study to address the behavior of different data sets during image processing and quantify important parameters during structure refinement. The automated data collection was done from the same human ribosome sample either as a conventional defocus range dataset or with a Volta phase plate close to focus (cfVPP) or with a small defocus (dfVPP). The analysis of image processing parameters shows that dfVPP data behave more robustly during cryo-EM structure refinement because particle alignments, Euler angle assignments and 2D & 3D classifications behave more stably and converge faster. In particular, less particle images are required to reach the same resolution in the 3D reconstructions. Finally, we find that defocus range data collection is also applicable to VPP. This study shows that data processing and cryo-EM map interpretation, including atomic model refinement, are facilitated significantly by performing VPP cryo-EM, which will have an important impact on structural biology.


Assuntos
Microscopia Crioeletrônica/métodos , Processamento de Imagem Assistida por Computador/métodos , Substâncias Macromoleculares/química , Coleta de Dados , Humanos , Ligantes , Substâncias Macromoleculares/ultraestrutura , Ribossomos/química , Ribossomos/ultraestrutura
17.
J Synchrotron Radiat ; 25(Pt 1): 108-115, 2018 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-29271759

RESUMO

Wavefront errors of rotationally parabolic refractive X-ray lenses made of beryllium (Be CRLs) have been recovered for various lens sets and X-ray beam configurations. Due to manufacturing via an embossing process, aberrations of individual lenses within the investigated ensemble are very similar. By deriving a mean single-lens deformation for the ensemble, aberrations of any arbitrary lens stack can be predicted from the ensemble with \bar{\sigma} = 0.034λ. Using these findings the expected focusing performance of current Be CRLs are modeled for relevant X-ray energies and bandwidths and it is shown that a correction of aberrations can be realised without prior lens characterization but simply based on the derived lens deformation. The performance of aberration-corrected Be CRLs is discussed and the applicability of aberration-correction demonstrated over wide X-ray energy ranges.

18.
J Struct Biol ; 197(2): 94-101, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-27235783

RESUMO

Cryo-electron tomography (CET) and subtomogram analysis allow studying the structures of macromolecular complexes in their natural context. The radiation sensitivity of vitrified biological specimens and the resulting low signal-to-noise ratio (SNR) in CET limit the amount of structural information that can be mined from tomographic data. The Volta phase plate (VPP) has emerged as an effective means to increase the SNR and hence contrast compared to 'conventional' defocus-based phase contrast transmission electron microscopy (CTEM). Here, we assess the performance of the VPP compared to CTEM in subtomogram analysis, using the mammalian 80S ribosome as a test case. Accurate focusing is the major factor for achieving high resolution with the VPP, as highlighted by a comparison of slightly different focusing strategies. From only 1400 subtomograms, the VPP yields a subtomogram average of the mammalian 80S ribosome at 9.6Å resolution without laborious contrast transfer function (CTF) correction. The subtomogram averages obtained using CTEM approaches are comparable, but suffer from lower signal transfer in certain frequency bands due to the oscillations of the CTF. Our study demonstrates that the VPP is a valuable tool for subtomogram analysis, because it enables improved performance and efficiency in terms of structure localization and number of subtomograms required for a given resolution.


Assuntos
Microscopia Crioeletrônica/instrumentação , Microscopia Crioeletrônica/métodos , Microscopia Eletrônica de Transmissão/instrumentação , Microscopia Eletrônica de Transmissão/métodos , Animais , Tomografia com Microscopia Eletrônica/instrumentação , Tomografia com Microscopia Eletrônica/métodos , Humanos , Ribossomos/ultraestrutura , Razão Sinal-Ruído
19.
J Struct Biol ; 197(2): 155-162, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-27663685

RESUMO

Phase plates in cryo-electron tomography (cryoET) improve contrast, increasing the ability to discern separate molecules and molecular complexes in dense biomolecular environments. Here, we applied this new technology to the activation of the human complement system. Binding of C1 to antigen-antibody complexes initiates a cascade of proteolytic events that deposits molecules onto adjacent surfaces and terminates with the formation of membrane-attack-complex (MAC) pores in the targeted membranes. We imaged steps in this process using a Volta phase plate mounted on a Titan Krios equipped with a Falcon-II direct electron detector. The data show patches of single-layer antibodies on the surface and C1 bound to antibody platforms, with ca. ∼4% of instances where C1r and C1s proteases have dissociated from C1, and potentially instances of C1 transiently interacting with its substrate C4 or product C4b. Next, extensive deposition of C4b and C3b molecules is apparent, although individual molecules cannot always be properly distinguished with the current methods. Observations of MAC pores include formation of both single and composite pores, and instances of potential soluble-MAC dissociation upon failure of membrane insertion. Overall, application of the Volta phase plate cryoET markedly improved the contrast in the tomograms, which allowed for individual components to be more readily interpreted. However, variability in the phase shift induced by the phase-plate during the course of an experiment, together with incomplete sampling during tomogram acquisition, limited the interpretability of the resulting tomograms. Our studies exemplify the potential in studying molecular processes with complex spatial topologies by phase-plate cryoET.


Assuntos
Complemento C1/ultraestrutura , Microscopia Crioeletrônica , Tomografia com Microscopia Eletrônica , Humanos
20.
J Struct Biol ; 197(2): 73-82, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-27444390

RESUMO

While cryo-electron tomography (cryo-ET) can reveal biological structures in their native state within the cellular environment, it requires the production of high-quality frozen-hydrated sections that are thinner than 300nm. Sample requirements are even more stringent for the visualization of membrane-bound protein complexes within dense cellular regions. Focused ion beam (FIB) sample preparation for transmission electron microscopy (TEM) is a well-established technique in material science, but there are only few examples of biological samples exhibiting sufficient quality for high-resolution in situ investigation by cryo-ET. In this work, we present a comprehensive description of a cryo-sample preparation workflow incorporating additional conductive-coating procedures. These coating steps eliminate the adverse effects of sample charging on imaging with the Volta phase plate, allowing data acquisition with improved contrast. We discuss optimized FIB milling strategies adapted from material science and each critical step required to produce homogeneously thin, non-charging FIB lamellas that make large areas of unperturbed HeLa and Chlamydomonas cells accessible for cryo-ET at molecular resolution.


Assuntos
Secções Congeladas/métodos , Proteínas de Membrana/ultraestrutura , Manejo de Espécimes/métodos , Chlamydomonas/ultraestrutura , Tomografia com Microscopia Eletrônica/métodos , Células HeLa , Humanos , Microscopia Eletrônica de Transmissão/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA