Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
1.
Rev. méd. Chile ; 139(12): 1544-1552, dic. 2011. ilus, tab
Article in Spanish | LILACS | ID: lil-627588

ABSTRACT

Background: The preferred treatment for ischemic mitral insufficiency is mitral valve repair with a prosthetic ring, because it does not deteriorate left ventricular function, allowing better immediate and long-term results. Aim: To assess long-term results of mitral annuloplasty with a prosthetic ring for ischemic mitral insufficiency. Patients and Methods: One hundred patients (68 men), with a mean age of 65.7 ± 8.6 years were included. They underwent a mitral annuloplasty with a prosthetic ring to treat ischemic mitral insufficiency, between February 1992 and May 2009. Fortyfour had a history of prior myocardial infarction and 46 had an evolving acute coronary syndrome. The inferior left ventricular wall was involved, exclusively or associated with an adjacent wall, in 72 cases. Coronary artery bypass grafts were performed in 92 patients and 32 required intra-aortic balloon pumping at some time during the peri-operative period. Results: Operative mortality was 10% (10 patients). During follow-up 30 patients died, at an average of 39 months after surgery (range: 3-142 months). Actuarial long-term survival rates at 1, 3 and 5 years were 79%, 72% and 64.5%, respectively. Trans esophageal echocardiogram performed in the operating room showed none or minimal residual mitral insufficiency in 96% of the cases. Echocardiographic follow-up was completed in 80% of the survivors; 79% of them had no or minimal mitral insufficiency. Only one patient was re-operated on due to severe mitral insufficiency and 4 required a permanent pacemaker. Conclusions: Considering the critical illness of these patients, good long-term results were observed after treatment of ischemic mitral regurgitation performing a mitral annuloplasty with a prosthetic ring.


Subject(s)
Aged , Female , Humans , Male , Heart Valve Prosthesis Implantation , Mitral Valve Annuloplasty , Mitral Valve Insufficiency/surgery , Follow-Up Studies , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/mortality , Kaplan-Meier Estimate , Mitral Valve Annuloplasty/adverse effects , Mitral Valve Annuloplasty/mortality , Mitral Valve Insufficiency/mortality , Mitral Valve Insufficiency/pathology , Reoperation/statistics & numerical data , Survival Rate , Treatment Outcome
2.
Rev. chil. radiol ; 17(3): 134-140, 2011. ilus
Article in Spanish | LILACS | ID: lil-608816

ABSTRACT

Purpose. To demonstrate the utility of 4D flow MR imaging for analyzing blood flow patterns and flow distribution in patients with congenital heart diseases. Methods: Six patients with congenital heart diseases were scanned using a standard cardiac MRI protocol, according to their condition. Additionally, 2D flow sequences of the great vessels, and a 4D flow sequence covering the entire heart were acquired. Flow patterns were visualized by using vector fields, streamlines and particle traces. Results: 4D flow technique depicted vortices and helical flow in the pulmonary artery of most patients, as well as in the aorta and superior vena cava of one patient with corrected aortic coarctation and a levoatrial cardinal vein. Conclusion: 4D flow MR imaging enables the identification of flow patterns difficult to detect with other diagnostic modalities. Comprehensive evaluation of flow patterns might help to understand the hemodynamic consequences of congenital heart diseases and their surgical procedures.


Objetivo. Demostrar la utilidad de 4D flow para el análisis de patrones y distribución de flujos en pacientes con cardiopatías congénitas. Métodos: Seis pacientes con cardiopatías congénitas fueron escaneados con un protocolo de resonancia magnética cardíaca estándar. Además se incluyeron secuencias de flujo 2D en los principales vasos del tórax y una secuencia 4D flow que cubría todo el corazón. Para la visualización de los patrones de flujo se emplearon vectores de velocidad, líneas de flujo y trazadores de partículas. Resultados: 4D flow reveló vórtices y hélices en la arteria pulmonar de la mayoría de los pacientes, y en la aorta y vena cava superior de un paciente con coartación aórtica reparada y vena cardinal levoatrial. Conclusiones: 4D flow permite identificar patrones de flujo en pacientes con cardiopatías congénitas, difíciles de observar con otros métodos diagnósticos. La evaluación de patrones de flujo podría contribuir a comprender las consecuencias hemodinámicas de diferentes cardiopatías congénitas.


Subject(s)
Humans , Male , Adolescent , Adult , Female , Child , Middle Aged , Heart Defects, Congenital/diagnosis , Heart Defects, Congenital/physiopathology , Magnetic Resonance Imaging/methods , Blood Flow Velocity/physiology , Aorta, Thoracic/physiopathology , Pulmonary Artery/physiopathology , Image Enhancement/methods , Aortic Coarctation/physiopathology , Regional Blood Flow , Vena Cava, Superior/physiopathology
SELECTION OF CITATIONS
SEARCH DETAIL