Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 57
Filter
1.
Article in English | WPRIM | ID: wpr-1043573

ABSTRACT

Background@#Coronary artery disease patients undergoing percutaneous coronary intervention (PCI) often exhibit reduced left ventricular ejection fraction (LVEF). However, the impact of LV dysfunction status in conjunction with platelet reactivity on clinical outcomes has not been previously investigated. @*Methods@#From the multicenter PTRG-DES (Platelet function and genoType-Related long-term prognosis in DES-treated patients) consortium, the patients were classified as preserved-EF (PEF: LVEF ≥ 50%) and reduced-EF (REF: LVEF< 5 0%) group by echocardiography. Platelet reactivity was measured using VerifyNow P2Y 12 assay and high platelet reactivity (HPR) was defined as PRU ≥ 252. The major adverse cardiac and cerebrovascular events (MACCEs) were a composite of death, myocardial infarction, stent thrombosis and stroke at 5 years after PCI. Major bleeding was defined as Bleeding Academic Research Consortium bleeding types 3–5. @*Results@#A total of 13,160 patients from PTRG-DES, 9,319 (79.6%) patients with the results of both PRU and LVEF were analyzed. The incidence of MACCE and major bleeding was higher in REF group as compared with PEF group (MACCEs: hazard ratio [HR] 2.17, P < 0.001, 95% confidence interval [CI] 1.85–2.55; major bleeding: HR 1.78, P < 0.001, 95% CI 1.39–2.78).The highest rate of MACCEs was found in patients with REF and HPR, and the difference between the groups was statistically significant (HR 3.14 in REF(+)/HPR(+) vs. PEF(+)/HPR(-) group,P <0.01, 95% CI 2.51–3.91). The frequency of major bleeding was not associated with the HPR in either group. @*Conclusion@#LV dysfunction was associated with an increased incidence of MACCEs and major bleeding in patients who underwent PCI. The HPR status further exhibited significant increase of MACCEs in patients with LV dysfunction in a large, real-world registry.Trial Registration: ClinicalTrials.gov Identifier: NCT04734028

2.
Yonsei Medical Journal ; : 257-264, 2024.
Article in English | WPRIM | ID: wpr-1045643

ABSTRACT

Purpose@#In a preclinical study using a swine myocardial infarction (MI) model, a delayed enhancement (DE)-multi-detector computed tomography (MDCT) scan was performed using a hybrid system alongside diagnostic invasive coronary angiography (ICA) without the additional use of a contrast agent, and demonstrated an excellent correlation in the infarct area compared with histopathologic specimens. In the present investigation, we evaluated the feasibility and diagnostic accuracy of a myocardial viability assessment by DE-MDCT using a hybrid system comprising ICA and MDCT alongside diagnostic ICA without the additional use of a contrast agent. @*Materials and Methods@#We prospectively enrolled 13 patients (median age: 67 years) with a previous MI (>6 months) scheduled to undergo ICA. All patients underwent cardiac magnetic resonance (CMR) imaging before diagnostic ICA. MDCT viability scans were performed concurrently with diagnostic ICA without the use of additional contrast. The total myocardial scar volume per patient and average transmurality per myocardial segment measured by DE-MDCT were compared with those from DE-CMR. @*Results@#The DE volume measured by MDCT showed an excellent correlation with the volume measured by CMR (r=0.986, p<0.0001). The transmurality per segment by MDCT was well-correlated with CMR (r=0.900, p<0.0001); the diagnostic performance of MDCT in differentiating non-viable from viable myocardium using a 50% transmurality criterion was good with a sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of 87.5%, 99.5%, 87.5%, 99.5%, and 99.1%, respectively. @*Conclusion@#The feasibility of the DE-MDCT viability assessment acquired simultaneously with conventional ICA was proven in patients with chronic MI using DE-CMR as the reference standard.

3.
Korean Circulation Journal ; : 843-854, 2023.
Article in English | WPRIM | ID: wpr-1041499

ABSTRACT

Background and Objectives@#We evaluated the effect of diabetes on the relationship between body mass index (BMI) and clinical outcomes in patients following percutaneous coronary intervention (PCI) with drug-eluting stent implantation. @*Methods@#A total of 6,688 patients who underwent PCI were selected from five different registries led by Korean Multicenter Angioplasty Team. They were categorized according to their BMI into the following groups: underweight (<18.5 kg/m 2 ), normal weight (18.5–24.9 kg/m 2 ), overweight to obese (≥25.0 kg/m 2 ). Major adverse cardiac and cerebrovascular events (MACCE), defined as a composite of death, nonfatal myocardial infarction, stroke, and target-vessel revascularization, were compared according to the BMI categories (underweight, normal and overweight to obese group) and diabetic status. All subjects completed 1-year follow-up. @*Results@#Among the 6,688 patients, 2,561 (38%) had diabetes. The underweight group compared to normal weight group had higher 1-year MACCE rate in both non-diabetic (adjusted hazard ratio [HR], 2.24; 95% confidence interval [CI], 1.04–4.84; p=0.039) and diabetic patients (adjusted HR, 2.86; 95% CI, 1.61–5.07; p<0.001). The overweight to obese group had a lower MACCE rate than the normal weight group in diabetic patients (adjusted HR, 0.67 [0.49–0.93]) but not in non-diabetic patients (adjusted HR, 1.06 [0.77–1.46]), with a significant interaction (p-interaction=0.025). @*Conclusions@#Between the underweight and normal weight groups, the association between the BMI and clinical outcomes was consistent regardless of the presence of diabetes.However, better outcomes in overweight to obese over normal weight were observed only in diabetic patients. These results suggest that the association between BMI and clinical outcomes may differ according to the diabetic status.

4.
Korean Circulation Journal ; : 324-337, 2022.
Article in English | WPRIM | ID: wpr-926511

ABSTRACT

Background and Objectives@#Identifying patients with high bleeding risk (HBR) is important when making decisions for antiplatelet therapy strategy. This study evaluated the impact of ticagrelor monotherapy after 3-month dual antiplatelet therapy (DAPT) according to HBR in acute coronary syndrome (ACS) patients treated with drug eluting stents (DESs). @*Methods@#In this post-hoc analysis of the TICO trial, HBR was defined by 2 approaches: meeting Academic Research Consortium for HBR (ARC-HBR) criteria or Predicting Bleeding Complications in Patients Undergoing Stent Implantation and Subsequent DAPT (PRECISEDAPT) score ≥25. The primary outcome was a 3–12 months net adverse clinical event (composite of major bleeding and adverse cardiac and cerebrovascular events). @*Results@#Of the 2,980 patients without adverse events during the first 3 months after DES implantation, 453 (15.2%) were HBR by ARC-HBR criteria and 504 (16.9%) were HBR by PRECISE-DAPT score. The primary outcome rate was higher in HBR versus non-HBR patients (by ARC-HBR criteria: hazard ratio [HR], 2.87; 95% confidence interval [CI], 1.76– 4.69; p<0.001; by PRECISE-DAPT score: HR, 3.09; 95% CI, 1.92–4.98; p<0.001). Ticagrelor monotherapy after 3-month DAPT was associated with lower primary outcome rate than ticagrelor-based 12-month DAPT regardless of HBR by ARC-HBR criteria, with similar magnitudes of therapy effect for HBR and non-HBR patients (p-interaction=0.400). Results were consistent by PRECISE-DAPT score (p-interaction=0.178). @*Conclusions@#In ACS patients treated with DESs, ticagrelor monotherapy after 3-month DAPT was associated with lower rate of adverse clinical outcomes regardless of HBR, with similar magnitudes of therapy effect between HBR and non-HBR.Trial Registration: ClinicalTrials.gov Identifier: NCT02494895

5.
Yonsei Medical Journal ; : 413-421, 2022.
Article in English | WPRIM | ID: wpr-927172

ABSTRACT

Purpose@#Platelet function test (PFT) results and genotype hold unique prognostic implications in East Asian patients. The aim of the PTRG-DES (Platelet function and genoType-Related long-term proGnosis in Drug-Eluting Stent-treated Patients with coronary artery disease) consortium is to assess the clinical impact thereof on long-term clinical outcomes in Korean patients with coronary artery disease during dual antiplatelet therapy (DAPT) including clopidogrel. @*Materials and Methods@#Searching publications on the PubMed, we reviewed clopidogrel treatment studies with PFT and/or genotype data for potential inclusion in this study. Lead investigators were invited to share PFT/genotype results, patient characteristics, and clinical outcomes to evaluate relationships among them. @*Results@#Nine registries from 32 academic centers participated in the PTRG-DES consortium, contributing individual patient data from 13160 patients who underwent DES implantation between July 2003 and August 2018. The PTRG-PFT cohort was composed of 11714 patients with available VerifyNow assay results. Platelet reactivity levels reached 218±79 P2Y12 reaction units (PRU), and high on-clopidogrel platelet reactivity based on a consensus-recommended cutoff (PRU >208) was observed in 55.9%. The PTRGGenotype cohort consisted of 8163 patients with candidate genotypes related with clopidogrel responsiveness. Of those with cytochrome P450 (CYP) 2C19 genotype, frequencies of carrying one and two loss-of-function allele (s) (*2 or *3) were 47.9% (intermediate metabolizers) and 14.2% (poor metabolizers), respectively. @*Conclusion@#The PTRG-DES consortium highlights unique values for on-clopidogrel platelet reactivity and CYP2C19 phenotype that may be important to developing optimal antiplatelet regimens in East Asian patients.

6.
Korean Circulation Journal ; : 123-133, 2022.
Article in English | WPRIM | ID: wpr-917386

ABSTRACT

Background and Objectives@#Atherectomy as a pretreatment has the potential to improve the outcomes of drug-coated balloon (DCB) treatment by reducing and modifying atherosclerotic plaques. The present study investigated the outcomes of atherectomy plus DCB (A+DCB) compared with DCB alone for the treatment of femoropopliteal artery disease. @*Methods@#A total of 311 patients (348 limbs) underwent endovascular therapy using DCB for native femoropopliteal artery lesions at two endovascular centers. Of these, 82 limbs were treated with A+DCB and 266 limbs with DCB alone. After propensity score matching based on clinical and lesion characteristics, a total of 82 pairs was compared for immediate and mid-term outcomes. @*Results@#For the matched study groups, the lesion length was 172.7±111.2 mm, and severe calcification was observed in 43.3%. The technical success rate was higher in the A+DCB group than in the DCB group (80.5% vs. 62.2%, p=0.015). However, the A+DCB group showed more procedure-related minor complications (37.0% vs. 13.4%, p=0.047). At 2-year follow-up, primary clinical patency (73.8% vs. 82.6%, p=0.158) and the target lesion revascularization (TLR)-free survival (84.3% vs. 88.2%, p=0.261) did not differ between the two groups. In Cox proportional hazard analysis, atherectomy showed no significant impact on the outcome of DCB treatments. @*Conclusions@#The pretreatment with atherectomy improved technical success of DCB treatment; however, it was associated with increased minor complications. In this study, A+DCB showed no clinical benefit in terms of TLR-free survival or clinical patency compared with DCB treatment alone.

7.
Article in English | WPRIM | ID: wpr-893907

ABSTRACT

Background and Objectives@#DENEX™ is a novel renal sympathetic denervation (RDN) system that is equipped with 3 electrodes that deliver radiofrequency energy to the renal nerves along renal arteries. The purpose of this study was to evaluate the safety and efficacy of RDN with DENEX™ in resistant hypertension. @*Methods@#This was an open-label, single-arm, multicenter, first-in-man pilot study. Between November 2016 and May 2018, a total of 16 patients were enrolled at 4 centers in South Korea. The inclusion criteria were systolic blood pressure (SBP) ≥150 mmHg and use of 3 or more antihypertensive medications, including diuretics. The primary objective was the safety outcome of RDN with the DENEX™ system. The secondary objective was efficacy outcome based on changes of office, and 24-hour ambulatory SBP from baseline to 3 months. The patients underwent abdominal computed tomography (CT) or duplex ultrasonogram before and 6 months after RDN. @*Results@#No major adverse events occurred after RDN for 6 month of follow-up period. There was no vascular complication either by CT or duplex ultrasonogram. The office SBP was significantly reduced from 164.6±11.6 mmHg at baseline to 142.0±20.4 mmHg (−24.4±24.4 mmHg, p=0.003) at 3 months. The ambulatory SBP was reduced from 151.44±12.85 mmHg at baseline to 140.0±16.5 mmHg (−13.1±18.9 mmHg, p=0.056) at 3 months. @*Conclusion@#RDN with the DENEX™ system showed a favorable safety profile in resistant hypertension. A significant reduction in office SBP and a borderline reduction in ambulatory SBP were observed.

8.
Korean Circulation Journal ; : 222-231, 2021.
Article in English | WPRIM | ID: wpr-893943

ABSTRACT

Background and Objectives@#Transcatheter aortic valve replacement (TAVR) has been reported as a good alternative for surgical aortic valve replacement in patients with small aortic annulus. Head-to-head comparisons of different transcatheter aortic valves in these patients are insufficient. We compared the outcomes after TAVR between two different types of recent transcatheter aortic valves (self-expanding vs. balloon-expandable) in patients with small aortic annulus. @*Methods@#A total of 70 patients with severe aortic stenosis and small annulus (mean diameter ≤23 mm or minimal diameter ≤21 mm on computed tomography) underwent TAVR with either a self-expanding valve with supra-annular location (n=45) or a balloon-expandable valve with intra-annular location (n=25). The echocardiographic hemodynamic parameters after TAVR and 1-year follow-up were compared. @*Results@#Between the self-expanding and balloon-expandable valve-treated patients, the clinical outcomes including permanent pacemaker implantation (11.1% vs. 8.0%), acute kidney injury stage 2 or 3 (4.4% vs. 4.0%), and major vascular complication (4.4% vs. 0.0%) were similar without all-cause mortality, stroke, and life-threatening bleeding during 30-day follow-up. Compared with the balloon-expandable valve-treated patients, the self-expanding valve-treated patients presented larger effective orifice area (EOA) (1.46±0.28 vs. 1.75±0.42 cm2 , p=0.002) and indexed EOA (0.95±0.21 vs. 1.18±0.28 cm2 /m2 , p=0.001), whereas mean aortic valve gradient (11.7±2.9 vs. 8.9±5.2 mmHg, P=0.005) and incidence of ≥moderate prosthesis-patient mismatch (36.0% vs. 8.9%, p=0.009) were lower. These hemodynamic differences were maintained at 1-year follow-up. @*Conclusions@#TAVR with self-expanding valves was associated with superior hemodynamic outcomes compared with balloon-expandable valves in patients with small aortic annulus.

9.
Yonsei Medical Journal ; : 990-996, 2021.
Article in English | WPRIM | ID: wpr-896574

ABSTRACT

Purpose@#Concerns have been consistently raised in regards to the considerable amount of contrast dye used during transcatheter aortic valve replacement (TAVR) in patients with renal insufficiency. In the present study, we introduced minimal contrast TAVR and compared its 30-day clinical outcomes with conventional TAVR. @*Materials and Methods@#We retrospectively investigated 369 patients who underwent TAVR between July 2011 and April 2020 in our institute. Among them, 93 patients with severe aortic stenosis and renal insufficiency (estimated glomerular filtration rate ≤50 mL/min/1.73 m2 ) were included and divided into a conventional TAVR group (n=56) and a minimal contrast TAVR group (n=37). In the minimal contrast TAVR group, the total amount of contrast was <10 mL during the entire TAVR procedure. Thirty-day major adverse clinical events (MACE), including death, stroke, implantation of permanent pacemaker, and initiation of hemodialysis, were investigated. @*Results@#The incidence of MACE was significantly lower in the minimal contrast TAVR group than the conventional TAVR group (16.2% vs. 42.9%, p=0.010). Death occurred in 9 patients (16.1%) in the conventional TAVR group and in 0 patients in the minimal contrast group (p=0.011). Hemodialysis was initiated in 2 patients (5.4%) in the minimal contrast TAVR group and in 7 patients (12.5%) in the conventional TAVR group (p=0.256). Multivariate regression analysis showed that the minimal contrast TAVR procedure was an independent predictor for reducing MACE (hazard ratio 0.208, 95% confidence interval: 0.080–0.541, p=0.001). @*Conclusion@#Minimal contrast TAVR is feasible and shows more favorable short-term clinical outcomes than conventional TAVR in patients with renal insufficiency.

10.
Yonsei Medical Journal ; : 209-214, 2021.
Article in English | WPRIM | ID: wpr-875617

ABSTRACT

Purpose@#Acute coronary occlusion is a rare but fatal complication that may occur during trans-catheter aortic valve implantation (TAVI) and appears more frequently in patients with low coronary heights. We evaluated the feasibility of self-expanding valves in patients with low coronary heights undergoing TAVI. @*Materials and Methods@#TAVI for native aortic valve stenosis was conducted in 276 consecutive patients between 2015 and 2019 at our institute. Using multi-detector computed tomography (MDCT), information on the aortic valve, coronary arteries, and vascular anatomy in 269 patients was analyzed. Patients with low coronary heights were defined as those with coronary heights of 10 mm or less during MDCT analysis. @*Results@#Among the 269 patients, 29 (10.8%) patients had coronary arteries with low heights. The mean coronary height was 8.9±1.2 mm in the left coronary artery. These patients with low coronary heights were treated with self-expandable (n=28) or balloon-expandable (n=1) valves. Prophylactic coronary protection with a guidewire, balloon, or stent prepositioned down at-risk coronary arteries was not pursued in all patients. No acute coronary occlusion occurred in any of these patients during TAVI. Five patients (17.9%) died during follow-up (average of 553.8 days), including four from non-cardiogenic causes and one from a cardiogenic (aggravation of heart failure) cause. @*Conclusion@#A considerable number of patients with low coronary heights were observed among TAVI candidates in this study. Use of a self-expandable valve may be feasible for successful TAVI without acute coronary occlusion in patients with low coronary heights.

11.
Article in English | WPRIM | ID: wpr-901611

ABSTRACT

Background and Objectives@#DENEX™ is a novel renal sympathetic denervation (RDN) system that is equipped with 3 electrodes that deliver radiofrequency energy to the renal nerves along renal arteries. The purpose of this study was to evaluate the safety and efficacy of RDN with DENEX™ in resistant hypertension. @*Methods@#This was an open-label, single-arm, multicenter, first-in-man pilot study. Between November 2016 and May 2018, a total of 16 patients were enrolled at 4 centers in South Korea. The inclusion criteria were systolic blood pressure (SBP) ≥150 mmHg and use of 3 or more antihypertensive medications, including diuretics. The primary objective was the safety outcome of RDN with the DENEX™ system. The secondary objective was efficacy outcome based on changes of office, and 24-hour ambulatory SBP from baseline to 3 months. The patients underwent abdominal computed tomography (CT) or duplex ultrasonogram before and 6 months after RDN. @*Results@#No major adverse events occurred after RDN for 6 month of follow-up period. There was no vascular complication either by CT or duplex ultrasonogram. The office SBP was significantly reduced from 164.6±11.6 mmHg at baseline to 142.0±20.4 mmHg (−24.4±24.4 mmHg, p=0.003) at 3 months. The ambulatory SBP was reduced from 151.44±12.85 mmHg at baseline to 140.0±16.5 mmHg (−13.1±18.9 mmHg, p=0.056) at 3 months. @*Conclusion@#RDN with the DENEX™ system showed a favorable safety profile in resistant hypertension. A significant reduction in office SBP and a borderline reduction in ambulatory SBP were observed.

12.
Korean Circulation Journal ; : 222-231, 2021.
Article in English | WPRIM | ID: wpr-901647

ABSTRACT

Background and Objectives@#Transcatheter aortic valve replacement (TAVR) has been reported as a good alternative for surgical aortic valve replacement in patients with small aortic annulus. Head-to-head comparisons of different transcatheter aortic valves in these patients are insufficient. We compared the outcomes after TAVR between two different types of recent transcatheter aortic valves (self-expanding vs. balloon-expandable) in patients with small aortic annulus. @*Methods@#A total of 70 patients with severe aortic stenosis and small annulus (mean diameter ≤23 mm or minimal diameter ≤21 mm on computed tomography) underwent TAVR with either a self-expanding valve with supra-annular location (n=45) or a balloon-expandable valve with intra-annular location (n=25). The echocardiographic hemodynamic parameters after TAVR and 1-year follow-up were compared. @*Results@#Between the self-expanding and balloon-expandable valve-treated patients, the clinical outcomes including permanent pacemaker implantation (11.1% vs. 8.0%), acute kidney injury stage 2 or 3 (4.4% vs. 4.0%), and major vascular complication (4.4% vs. 0.0%) were similar without all-cause mortality, stroke, and life-threatening bleeding during 30-day follow-up. Compared with the balloon-expandable valve-treated patients, the self-expanding valve-treated patients presented larger effective orifice area (EOA) (1.46±0.28 vs. 1.75±0.42 cm2 , p=0.002) and indexed EOA (0.95±0.21 vs. 1.18±0.28 cm2 /m2 , p=0.001), whereas mean aortic valve gradient (11.7±2.9 vs. 8.9±5.2 mmHg, P=0.005) and incidence of ≥moderate prosthesis-patient mismatch (36.0% vs. 8.9%, p=0.009) were lower. These hemodynamic differences were maintained at 1-year follow-up. @*Conclusions@#TAVR with self-expanding valves was associated with superior hemodynamic outcomes compared with balloon-expandable valves in patients with small aortic annulus.

13.
Yonsei Medical Journal ; : 990-996, 2021.
Article in English | WPRIM | ID: wpr-904278

ABSTRACT

Purpose@#Concerns have been consistently raised in regards to the considerable amount of contrast dye used during transcatheter aortic valve replacement (TAVR) in patients with renal insufficiency. In the present study, we introduced minimal contrast TAVR and compared its 30-day clinical outcomes with conventional TAVR. @*Materials and Methods@#We retrospectively investigated 369 patients who underwent TAVR between July 2011 and April 2020 in our institute. Among them, 93 patients with severe aortic stenosis and renal insufficiency (estimated glomerular filtration rate ≤50 mL/min/1.73 m2 ) were included and divided into a conventional TAVR group (n=56) and a minimal contrast TAVR group (n=37). In the minimal contrast TAVR group, the total amount of contrast was <10 mL during the entire TAVR procedure. Thirty-day major adverse clinical events (MACE), including death, stroke, implantation of permanent pacemaker, and initiation of hemodialysis, were investigated. @*Results@#The incidence of MACE was significantly lower in the minimal contrast TAVR group than the conventional TAVR group (16.2% vs. 42.9%, p=0.010). Death occurred in 9 patients (16.1%) in the conventional TAVR group and in 0 patients in the minimal contrast group (p=0.011). Hemodialysis was initiated in 2 patients (5.4%) in the minimal contrast TAVR group and in 7 patients (12.5%) in the conventional TAVR group (p=0.256). Multivariate regression analysis showed that the minimal contrast TAVR procedure was an independent predictor for reducing MACE (hazard ratio 0.208, 95% confidence interval: 0.080–0.541, p=0.001). @*Conclusion@#Minimal contrast TAVR is feasible and shows more favorable short-term clinical outcomes than conventional TAVR in patients with renal insufficiency.

14.
Korean Circulation Journal ; : 443-457, 2020.
Article in English | WPRIM | ID: wpr-833044

ABSTRACT

BACKGROUND AND OBJECTIVES@#We sought to investigate an anti-atherosclerotic and anti-inflammatory effect of sodium-glucose cotransporter-2 (SGLT-2) inhibitors in normoglycemic atherosclerotic rabbit model.@*METHODS@#Male New Zealand white rabbits (n=26) were fed with a 1% high-cholesterol diet for 7 weeks followed by normal diet for 2 weeks. After balloon catheter injury, the rabbits were administered with the Dapagliflozin (1mg/kg/day) or control-medium for 8 weeks (n=13 for each group). All lesions were assessed with angiography, optical coherence tomography (OCT), and histological assessment.@*RESULTS@#Atheroma burden (38.51±3.16% vs. 21.91±1.22%, p<0.01) and lipid accumulation (18.90±3.63% vs. 10.20±2.03%, p=0.047) was significantly decreased by SGLT-2 inhibitor treatment. The SGLT-2 inhibitor group showed lower macrophage infiltration (20.23±1.89% vs. 12.72±1.95%, p=0.01) as well as tumor necrosis factor (TNF)-α expression (31.17±4.40% vs. 19.47±2.10%, p=0.025). Relative area of inducible nitric oxide synthase+ macrophages was tended to be lower in the SGLT-2 inhibitor-treated group (1.00±0.16% vs. 0.71±0.10%, p=0.13), while relative proportion of Arg1⁺ macrophage was markedly increased (1.00±0.27% vs. 2.43±0.64%, p=0.04). As a result, progression of atherosclerosis was markedly attenuated in SGLT-2 inhibitor treated group (OCT area stenosis, 32.13±1.20% vs. 22.77±0.88%, p<0.01). Mechanistically, SGLT-2 treatment mitigated the inflammatory responses in macrophage. Especially, Toll-like receptor 4uclear factor-kappa B signaling pathway, and their downstream effectors such as interleukin-6 and TNF-α were markedly suppressed by SGLT-2 inhibitor treatment.@*CONCLUSIONS@#These results together suggest that SGLT-2 inhibitor exerts an anti-atherosclerotic effect through favorable modulation of inflammatory response as well as macrophage characteristics in non-diabetic situation.

15.
Korean Circulation Journal ; : 880-889, 2020.
Article | WPRIM | ID: wpr-833072

ABSTRACT

Previous pathologic, intravascular imaging, and clinical studies have investigated the association between adverse cardiac events and stent malapposition, including acute stent malapposition (ASM, that is detected at index procedure) and late stent malapposition (LSM, that is detected during follow-up) that can be further classified into late-persistent stent malapposition (LPSM, ASM that remains at follow-up) or late-acquired stent malapposition (LASM, newly developed stent malapposition at follow-up that was not present immediately after index stent implantation). ASM has not been associated with adverse cardiac events compared with non-ASM, even in lesions with large-sized malapposition. The clinical outcomes of LSM may depend on its subtype. The recent intravascular ultrasound studies with long-term follow-up have consistently demonstrated that LASM steadily increased the risk of thrombotic events in patients with first-generation drug-eluting stents (DESs). This association has not yet been identified in LPSM. Accordingly, it is reasonable that approaches to stent malapposition should be based on its relationship with clinical outcomes. ASM may be tolerable after successful stent implantation, whereas prolonged anti-thrombotic medications and/or percutaneous interventions to modify LASM may be considered in selected patients with first-generation DESs. However, these treatments are still questionable due to lack of firm evidences.

16.
Yonsei Medical Journal ; : 597-605, 2020.
Article | WPRIM | ID: wpr-833347

ABSTRACT

Purpose@#Although current guidelines recommend the administration of dual antiplatelet therapy (DAPT) for up to 12 months after the implantation of a drug-eluting stent (DES), extended DAPT is frequently used in real-world practice. @*Materials and Methods@#From the Korean Multicenter Angioplasty Team registry, we identified a total of 1414 patients who used DAPT for >3 years after DES implantation (extended-DAPT group) and conducted a landmark analysis at 36 months after the index procedure. We evaluated the determinants for and long-term outcomes of extended DAPT and compared the occurrence of major adverse cardiovascular and cerebrovascular events (MACCE), defined as the composite of all-cause death, myocardial infarction, stent thrombosis, and stroke, between the extended-DAPT group and the guideline-DAPT group [DAPT <1 year after DES implantation (n=1273)]. @*Results@#Multivariate analysis indicated the occurrence of acute coronary syndrome as the most significant clinical determinant of the use of extended DAPT. Bifurcation, stent diameter ≤3.0 mm, total stented length ≥28 mm, and use of first-generation DESs were also significant angiographic and procedural determinants. MACCE rates were similar between the extended-DAPT group and the guideline-DAPT group in crude analysis [hazard ratio (HR), 1.08; 95% confidence interval (CI), 0.69–1.68; p=0.739] and after propensity matching (HR, 1.22; 95% CI, 0.72–2.07; p=0.453). Major bleeding rates were comparable between the two groups. @*Conclusion@#In patients undergoing percutaneous coronary intervention, indefinite use of DAPT does not show superior outcomes to those of guideline-DAPT. Major bleeding rates are also similar.

17.
Yonsei Medical Journal ; : 851-859, 2020.
Article | WPRIM | ID: wpr-833398

ABSTRACT

Purpose@#Thrombocytopenia (platelet count <150×103 /μL) is associated with poor outcomes in various critical illness settings. However, the prognostic value of platelet count in patients with cardiogenic shock (CS) remains unclear. @*Materials and Methods@#We enrolled 1202 patients between January 2014 and December 2018 from a multicenter retrospective– prospective cohort registry of CS. Clinical characteristics and treatment outcomes were compared between the patients with and without thrombocytopenia. @*Results@#At presentation with CS, 244 (20.3%) patients had thrombocytopenia. The patients with thrombocytopenia had lower blood pressure, hemoglobin level, and worse liver and renal functions compared to the patients without. During hospitalization, the patients with thrombocytopenia had more frequent gastrointestinal bleeding (10.5% vs. 3.8%, p=0.009), sepsis (8.3% vs. 2.6%, p=0.013), requirement of renal replacement therapy (36.5% vs. 18.9%, p<0.001), requirement of mechanical ventilation (65.2% vs.54.4%, p=0.003), longer intensive care unit stay (8 days vs. 4 days, p<0.001), and thirty-day mortality (40.2% vs. 28.5%, p<0.001) compared to those without. In addition, the platelet count was an independent predictor of 30-day mortality (per 103 /µL decrease; adjusted hazard ratio: 1.002, 95% confidence interval: 1.000–1.003, p=0.021). @*Conclusion@#Thrombocytopenia at CS presentation was associated with worse clinical findings, higher frequencies of complications, and longer stay at the intensive care unit. Also, thrombocytopenia was independently associated with increased 30-day mortality.(Clinical trial registration No. NCT02985008).

18.
Korean Circulation Journal ; : 443-457, 2020.
Article in English | WPRIM | ID: wpr-816671

ABSTRACT

BACKGROUND AND OBJECTIVES: We sought to investigate an anti-atherosclerotic and anti-inflammatory effect of sodium-glucose cotransporter-2 (SGLT-2) inhibitors in normoglycemic atherosclerotic rabbit model.METHODS: Male New Zealand white rabbits (n=26) were fed with a 1% high-cholesterol diet for 7 weeks followed by normal diet for 2 weeks. After balloon catheter injury, the rabbits were administered with the Dapagliflozin (1mg/kg/day) or control-medium for 8 weeks (n=13 for each group). All lesions were assessed with angiography, optical coherence tomography (OCT), and histological assessment.RESULTS: Atheroma burden (38.51±3.16% vs. 21.91±1.22%, p<0.01) and lipid accumulation (18.90±3.63% vs. 10.20±2.03%, p=0.047) was significantly decreased by SGLT-2 inhibitor treatment. The SGLT-2 inhibitor group showed lower macrophage infiltration (20.23±1.89% vs. 12.72±1.95%, p=0.01) as well as tumor necrosis factor (TNF)-α expression (31.17±4.40% vs. 19.47±2.10%, p=0.025). Relative area of inducible nitric oxide synthase+ macrophages was tended to be lower in the SGLT-2 inhibitor-treated group (1.00±0.16% vs. 0.71±0.10%, p=0.13), while relative proportion of Arg1⁺ macrophage was markedly increased (1.00±0.27% vs. 2.43±0.64%, p=0.04). As a result, progression of atherosclerosis was markedly attenuated in SGLT-2 inhibitor treated group (OCT area stenosis, 32.13±1.20% vs. 22.77±0.88%, p<0.01). Mechanistically, SGLT-2 treatment mitigated the inflammatory responses in macrophage. Especially, Toll-like receptor 4/nuclear factor-kappa B signaling pathway, and their downstream effectors such as interleukin-6 and TNF-α were markedly suppressed by SGLT-2 inhibitor treatment.CONCLUSIONS: These results together suggest that SGLT-2 inhibitor exerts an anti-atherosclerotic effect through favorable modulation of inflammatory response as well as macrophage characteristics in non-diabetic situation.


Subject(s)
Humans , Male , Rabbits , Angiography , Atherosclerosis , Catheters , Constriction, Pathologic , Diet , Interleukin-6 , Macrophages , Nitric Oxide , Plaque, Atherosclerotic , Toll-Like Receptors , Tomography, Optical Coherence , Tumor Necrosis Factor-alpha
19.
Article in 0 | WPRIM | ID: wpr-836070

ABSTRACT

Objective@#The aim of this study was to investigate whether a new generic rosuvastatin is non-inferior to a proprietary one in terms of lipid-lowering efficacy. We also evaluated its non-lipid effects including adverse events. @*Methods@#One-hundred and fifty-eight patients with cardiovascular risks requiring pharmacological lipid-lowering therapy were screened. After a 4-week run-in period, 126 individuals who met the lipid criteria for drug therapy were randomly assigned to receive the new generic or proprietary rosuvastatin 10 mg daily for 8 weeks. The primary outcome variables were low-density lipoprotein-cholesterol (LDL-C) reduction and LDL-C target achievement. Hematological and biochemical parameters and adverse events were assessed. @*Results@#After 8 weeks of drug treatment, the mean percentage change in LDL-C was not different between the groups (−45.5%±19.9% and −45.1%±19.0% for generic and proprietary rosuvastatin, respectively; p=0.38). The LDL-C target achievement rate was similar between the groups (75.0% and 77.1% for generic and proprietary rosuvastatin, respectively; p=0.79). The percentage change in the other lipid profiles was not significantly different. Although generic- and proprietary rosuvastatins modestly affected creatine kinase and blood pressure, respectively, the changes were all within normal ranges. Incidence of adverse events did not differ between the receivers of the 2 formulations. @*Conclusion@#The new generic rosuvastatin was non-inferior to the proprietary rosuvastatin in terms of lipid-lowering efficacy. The rosuvastatin formulations did not exhibit clinically significant non-lipid effects with good safety profiles. Our study provides comprehensive data regarding 2 rosuvastatin formulations in East Asian subjects.

20.
Yonsei Medical Journal ; : 1108-1111, 2019.
Article in English | WPRIM | ID: wpr-762047

ABSTRACT

The primary concern in percutaneous coronary intervention for bifurcation lesions is occlusion of a side branch after stenting of a main branch, especially in high-risk patients. We describe a novel technique, consecutive jailed- and kissing-Corsair technique, using a Corsair microcatheter for protection of side branches in bifurcation lesions.


Subject(s)
Humans , Percutaneous Coronary Intervention , Stents
SELECTION OF CITATIONS
SEARCH DETAIL