Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Hematol., Transfus. Cell Ther. (Impr.) ; 44(3): 352-357, July-Sept. 2022. tab, graf
Article in English | LILACS | ID: biblio-1405006

ABSTRACT

ABSTRACT Introduction: Erythrocyte phenotyping is a very important test in the adoption of prophylactic measures to reduce transfusion reactions/alloimmunizations in polytransfused patients. The blood group Diego, in its current, form has 22 antigens, of which 4 are immunogenic, being Dia/Dib and Wra/Wrb, while the others are less expressive. The antigen Dia is of low incidence among whites and blacks, however, it is common in the South American indigenous and Asian Mongolian populations. It is also considered a system of clinical importance for its immunogenicity. Method: The present study aimed to carry out a retrospective and descriptive survey of the frequency of the Dia antigen in the blood donor population at the HEMOPA Foundation Coordinating Blood Center from 12/2018 to 1/2000. The data obtained were from the HEMOPA Foundation SBS Progress and SBS WEB Systems databases. Results: During this period, 941,744 blood bags were collected and, of these, 930 bags were phenotyped for the Dia antigen, of which 842 were negative and 88 (9.7%) positive. The research showed that, among the positive donors for the antigen Dia, 88.6% were brown, 3.4%, black and 8%, white. In the statistical analysis, the frequency observed was higher in browns. Conclusion: In the present investigation, we concluded that our region has a relatively higher frequency of the Dia antigen, when compared to the rest of Brazil, and it occurs more often in browns.


Subject(s)
Transfusion Reaction , Blood Group Antigens , Hemotherapy Service
2.
J. Bras. Patol. Med. Lab. (Online) ; 58: e4422022, 2022. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1375695

ABSTRACT

ABSTRACT Introduction Differential counting of erythroblasts in blood samples by hematology analyzers still has limitations. Technological advances in blood count equipment have proposed the fully automated counting of these cells, however, not without its validation. Objective Validate the automated count of erythroblasts in peripheral blood in the Mindray BC6000 hematology analyzer and verify the existence of correlation of the maturation stages of erythroblasts with the equipment's graphics. Material and Methods Prospective study with peripheral blood samples from the Clinical Pathology Laboratory Dr Paulo C. Azevedo, regardless of age and gender, to validate the erythroblast count in the Mindray BC6000 hematology analyzer compared to the manual method (gold standard), in the period of June 2019 to December 2020. Results Seventeen peripheral blood samples were analyzed from newborns (09/17 - 52.3%) and from patients older than 2 years (08/17 - 47.7%) who had more than 18% of erythroblasts after morphological analysis of the sample. Statistical analysis of erythroblast counts by the two methodologies showed that the Mindray BC6000 hematological counter has good reproducibility, precision and linearity. There was no correlation between the maturation stages of erythroblasts and the equipment graphics. Conclusion The proposed validation showed that the Mindray BC6000 hematological counter has good analytical performance for counting erythroblasts in peripheral blood. However, there is no correlation between the maturation stages of erythroblasts with the graphics generated by the equipment.


RESUMO Introdução A contagem diferencial de eritroblastos em amostras de sangue por analisadores de hematologia ainda apresenta limitações. Os avanços tecnológicos nos equipamentos de hemograma têm proposto a contagem totalmente automatizada dessas células, porém, não sem sua validação. Objetivo Validar a contagem automatizada de eritroblastos no sangue periférico no analisador hematológico Mindray BC6000 e verificar a existência de correlação dos estágios de maturação dos eritroblastos com os gráficos do equipamento. Material e Métodos Estudo prospectivo com amostras de sangue periférico do Laboratório de Patologia Clínica Dr. Paulo C. Azevedo, independente de idade e sexo, para validação da contagem de eritroblastos no analisador hematológico Mindray BC6000 em comparação ao método manual (padrão ouro), no período de junho de 2019 a dezembro de 2020. Resultados Foram analisadas 17 amostras de sangue periférico de recém-nascidos (17/09 - 52,3%) e de pacientes maiores de 2 anos (17/08 - 47,7%) que apresentavam mais de 18% de eritroblastos após análise morfológica da amostra. A análise estatística das contagens de eritroblastos pelas duas metodologias mostrou que o contador hematológico Mindray BC6000 tem boa reprodutibilidade, precisão e linearidade. Não houve correlação entre os estágios de maturação dos eritroblastos e os gráficos do equipamento. Conclusão A validação proposta mostrou que o contador hematológico Mindray BC6000 apresenta bom desempenho analítico para contagem de eritroblastos em sangue periférico. Porém, não há correlação entre os estágios de maturação dos eritroblastos com os gráficos gerados pelo equipamento.

SELECTION OF CITATIONS
SEARCH DETAIL