Article in Japanese | WPRIM | ID: wpr-367234

ABSTRACT

A 79-year-old woman had received implantation of a pace maker for sick sinus syndrome at age 64 and tricuspid valve annuloplasty and Maze at age 68. Furthermore, she underwent tricuspid valve and mitral valve replacement with a bioprosthesis because of tricuspid valve and mitral valve regurgitation at age 73. She was referred to our institution for congestive heart failure in November 2005, because her bioprostheses at the mitral and tricuspid positions had shown significant regurgitation due to the degeneration of the prostheses, which required rereplacement. Because 1) surgical treatment of the heart had been performed twice in the past, 2) the general condition was not good owing to cirrhosis and hypothyroidism and 3) the durability of bioprostheses is short, we performed mitral valve re-replacement by using the “valve-on-valve” technique for reducing the invasion of surgical therapy. She had a satisfactory postoperative course. The “valve-on-valve” technique is a useful option for the re-replacement of bioprosthesis because it obviates the need for removing the sewing ring of the previous bioprosthesis.

2.
Article in Japanese | WPRIM | ID: wpr-367140

ABSTRACT

We report a rare case with infection of a stent-graft. A 82-year-old man, who had undergone endovascular stent grafting to repair the descending aortic aneurysm 2 years previously, was admitted with high-grade fever. The blood culture detected methicillin-resistant <i>Staphylococcus aureus</i> (MRSA). Endoleak due to stent-graft infection was diagnosed and operation for synthetic graft replacement was performed. The synthetic graft was infiltrated in Rifampicin prior to the graft replacement to prevent re-infection. Additionally, the graft was covered with the greater omentum. He was discharged on the 45th day after surgery without any problems. One year follow-up showed no sign of re-infection of the graft.

3.
Article in Japanese | WPRIM | ID: wpr-367196

ABSTRACT

A 49-year-old woman was found to have unruptured Valsalva's sinus aneurysm. All of the sinuses were involved in the anuerysmal dilatation and the aortic valve was intact with no aortic insufficiency. Aortic root reconstruction surgery (root remodeling operation) was successfully performed and the histopathology of the aortic wall showed healed aortitis. Her postoperative course was uneventful. Valve-Sparing surgery can be one option, even in cases with aortitis.

4.
Article in Japanese | WPRIM | ID: wpr-367044

ABSTRACT

Although recent progress in surgery for acute traumatic rupture of the thoracic aorta is encouraging, hospital mortality remains high due to associated fatal lesions. Delayed repair of acute aortic rupture, after management of critical lesions, has been reported in the literature with increasing frequency. We present here a successful operative case of a 54-year-old-woman with acute traumatic aortic rupture. She was admitted to the intensive care unit with loss of consciousness, rib fracture and lung contusion in order to investigate additional critical lesions under strict control of systolic blood pressure under 120mmHg. After completion of all diagnostic procedures, aortic repair was performed 2 days after the accident. The intima of the aorta was found to be disrupted for two thirds of the circumference and pseudoaneurysm was diagnosed. A gelatin-coated vascular prosthesis with one branch was interposed under cardiopulmonary bypass during which general heparinization, systemic hypothermia (20°C) and retrograde brain perfusion method were used. She recovered uneventfully and was discharged 2 weeks after the operation.

5.
Article in Japanese | WPRIM | ID: wpr-366931

ABSTRACT

The non-invasive cardiac output (NICO) monitor is a new device in order to measure cardiac output (CO). A rebreathing circuit is built in the NICO monitor and CO is calculated using the Fick CO<sub>2</sub> equation. We compared this technique with the standard thermodilution (TDCO) technique in patients with thoracic and abdominal surgery. Thirty-two paired data were obtained in 17 patients. Correlation between the two methods in patients with controlled mechanical ventilation (CMV) was fair, with a correlation coefficient of 0.85. However, the correlation coefficient of the two methods was 0.60 in spontaneous breathing patients. Bland-Altman analysis showed a bias of 0.24±0.68 (mean±2SD) in CMV patients and 1.44±1.28 in spontaneous breathing patients. The NICO value was inversely proportional to an end-tidal CO<sub>2</sub> difference (ΔETCO<sub>2</sub>) between pre-rebreathing and post-rebreathing. The large bias in spontaneously breathing patients might be due to a small ΔETCO<sub>2</sub> in spontaneously breathing patients. The NICO monitor has a tendency to measure higher CO values in spontaneously breathing patients.