Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Chinese Journal of Radiological Health ; (6): 269-275, 2021.
Article in Chinese | WPRIM | ID: wpr-974367

ABSTRACT

Objective This study reconstructed 4D-CBCT for fully automatic compensated sliding motion by incorporating the bilateral filtering into the Deformable Vector Field (DVF). Methods First, a motion compensated simultaneous algebraic reconstruction technique (Modified Simultaneous Algebra Reconstruction Technique, mSART) was used to generate a high quality reference phase by using all phase projection stogether with the initial 4D-DVFs, which were generated via Demons registration between 0% phase and each other phaseimage. The 4D-DVF was optimized by matching the forward projection of the deformed 0% phase with the measured projection of the target phase. The loss function’s DVF smoothing constrain term contained bilateral filtering kernel that contained: 1) an spatial domain Guassian kernel; 2) animage intensity domain Guassian kernel; and 3) a DVF domain Guassian kernel. By choosing suitable kernel variances, the sliding motion can be extracted. A non-linear conjugate gradient optimizer wasused. We validated the algorithm on a Non-Uniform Rotational B- spline based Cardiac-Torso (NCAT) phantom. Quantification was evaluated by: 1) the Root-Mean-Square-Error (RMSE) together with the Maximum-Error (MaxE); 2) the Dice coefficient of the extracted lung contour from the final reconstructed images and 3) the relative reconstruction error (RE) to evaluate the algorithm's performance. Results The motion trajectory's RMSE/MaxEare 0.796/1.02 mm for bilateral filtering reconstruction; and 2.704/4.08 mm for original reconstruction. Image content such a stherib position, the hearted gedefinition, the fibrous structures all had been better corrected with bilateral filtering. Conclusion We developed a bilateral filtering based fully automatic sliding motion compensated 4D-CBCT scheme. Digital phantom study confirmed the improved motion estimation and image reconstruction ability. It can be used as a 4D-CBCT image guidance tool for lung SBRTtreatment.

2.
Basic & Clinical Medicine ; (12): 1261-1263, 2015.
Article in Chinese | WPRIM | ID: wpr-479323

ABSTRACT

Objective To explore the expression of thrombospondin-1 ( TSP-1 ) and bone morphogenetic protein-7 ( BMP-7 ) in mucus membrcane of chronic rhinosinusitis ( CRS ) and its potential significance in pathogenesis . Methods TSP-1 ,BMP-7 and TGF-β1 were detected by ELISA .Results The expression level of TSP-1 and TGF-β1 increased gradually with the advanced stage of CRSsNP ( P<0.05 ) .The expression of BMP-7 decreased gradu-ally with the advanced stage of CRSsNP ( P<0.05 ) .The expression of TSP-1 and TGF-β1 decreased gradually with the advanced stage of CRSwNP ( P<0.05 ) .The expression level of BMP-7 increased gradually with the ad-vanced stage of CRSwNP ( P<0.05 ) .Conclusions The expressions of TSP-1 and BMP-7 were abnormal in nasal mucosa of CRS , which might be involved in the pathogenesis of CRS .

SELECTION OF CITATIONS
SEARCH DETAIL