Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
1.
Clinics in Orthopedic Surgery ; : 793-799, 2023.
Article in English | WPRIM | ID: wpr-1000184

ABSTRACT

Background@#The application of biportal endoscopic spinal surgery (BESS) in spine surgery is increasing. However, the clinical results of related studies have been inconsistent. In this study, the perioperative and clinical outcomes of two techniques in singlelevel lumbar decompression surgery were compared using the perspective of a spine surgeon experienced in microscopic surgery but inexperienced in BESS. @*Methods@#This is a retrospective study performed with prospectively collected data. From April 2019, 50 consecutive patients who underwent a single-level lumbar decompression surgery with BESS were evaluated. Additionally, the data of 150 consecutive patients who underwent the same microscopic surgery before April 2019 were collected. We performed 1 : 1 ratio propensity score matching for these two groups to adjust for baseline variables. The postoperative patient-reported outcome measures included the Oswestry Disability Index (ODI) and numeric rating scale for the back and leg preoperatively and at 6 months after surgery. The laboratory data (C-reactive protein [CRP, mg/L] and hemoglobin [Hb, g/dL]) were measured preoperatively and 3 times (1, 2, and 3 or 4 days) postoperatively. In these periods, the peak and lowest CRP and Hb concentrations were evaluated. The perioperative outcomes, operation time (from skin incision to dressing), length of hospital stay, drainage (for 24 hours after surgery), and surgeryrelated complications were also evaluated. @*Results@#Forty-seven patients (27 men and 20 women) were included in each group. The postoperative 6-month ODI was significantly lower in the BESS group than in the microscope group (6.90 ± 5.98 vs. 11.54 ± 9.70). The peak CRP concentration (16.63 ± 19.41 vs. 42.40 ± 37.73, p < 0.001) and CRP increment (peak CRP minus preoperative CRP, 14.69 ± 19.47 vs. 40.71 ± 37.32, p < 0.001) were significantly higher in the microscope group. Operation time (83.72 ± 35.71 vs. 70.27 ± 23.24, p = 0.047) was significantly longer in the BESS group. Surgery-related complications were found in 6 and 3 cases in the BESS group (3 revisions, 2 dural tears, and 1 conversion to open surgery) and microscope group (2 revisions and 1 hematoma), respectively. @*Conclusions@#BESS as a new technique resulted in satisfying short-term outcomes. It was a well-tolerated option for surgical treatment of single-level lumbar degenerative disease. The relatively high incidence of recurrence at the index level and incidental dural tears should be considered for surgeons new to BESS; however, these were manageable complications.

2.
Clinics in Orthopedic Surgery ; : 960-967, 2023.
Article in English | WPRIM | ID: wpr-1000163

ABSTRACT

Background@#The commercially available design of a three-dimensional (3D)–printed titanium (3D-Ti) cage can be divided into two types according to the presence of a window: a cage with a window that allows filling of bone graft materials and a non-window cage for stand-alone use. This prospective observational case series study aimed to explore the clinical feasibility of using a nonwindow type 3D-Ti cage in cases of combined window and non-window cage implantation. Furthermore, we evaluated the bone in growth patterns of non-window cages and their correlation with published fusion grading systems. @*Methods@#A total of 31 consecutive patients who underwent single-level posterior lumbar interbody fusion surgery were included. Two 3D-Ti cages with different designs were inserted: a non-window cage on the left side and a window cage on the right side.Radiographic fusion was defined by the segmental angle between flexion and extension radiographs (F-E angle) and cage bridging bone (CBB) scores on computed tomography. The association between the F-E angle and osteointegration scoring system including the surface osteointegration ratio (SOR) score was analyzed. @*Results@#Radiographic fusion was achieved in 27 of 31 patients (87%) at 12 months postoperatively. Among the non-window cages, 23 of 31 (74.2%) had fair SOR scores, while 19 of 31 (61.3%) window cages had fair intra-cage CBB scores. The higher the SOR score was, the smaller the flexion-extension angle (SOR 0 vs. SOR 1: 6.30° ± 2.43° vs. 1.95° ± 0.99°, p < 0.001; SOR 0 vs. SOR 2: 6.03° ± 2.43° vs. 0.99°± 0.74°, p < 0.001). @*Conclusions@#The clinical feasibility of using a non-window 3D-Ti cage during lumbar interbody fusion might be acceptable. Furthermore, a newly suggested fusion criterion for the use of the non-window cage, the SOR score, showed a significant association with the published fusion grading systems, demonstrating its feasibility in determining interbody fusion in lumbar spinal surgery.

3.
Asian Spine Journal ; : 492-499, 2023.
Article in English | WPRIM | ID: wpr-999633

ABSTRACT

Methods@#In retrospectively collected data, 149 patients who underwent single-level ACDF for degenerative disease were enrolled and divided into non-plating (n=66) and plating (n=83). Interspinous motion (ISM) at the arthrodesis segment, Numeric Rating Scale (NRS) for neck pain, and Neck Disability Index (NDI) were serially evaluated at 3, 6, and 12 months postoperatively. Predictable factors for fusion, including age, sex, plating, diabetes, smoking, and type of grafts, were investigated, and fusion was defined as ISM <1 mm. @*Results@#In both groups, ISM was the highest at 3 months and gradually decreased thereafter, and the plating group showed significantly lower serial ISM than the non-plating group at 12 months. The plating group had lower NRS and NDI scores than the nonplating group at 12 months, and the difference in the NRS scores was statistically significant, particularly at 3 and 6 months, although that of the NDI scores was not. In a multivariate analysis, plating was the most powerful predictor for fusion. @*Conclusions@#Plating significantly decreases the serial ISM compared with non-plating in single-level ACDF, and such decreased motion is correlated with decreased neck pain until 12 months postoperatively, particularly at 3 and 6 months. Given that plating was the most predictive factor for fusion, we recommend plating even in single-level ACDF for better early clinical outcomes.

4.
Journal of Korean Medical Science ; : e116-2020.
Article | WPRIM | ID: wpr-831501

ABSTRACT

Background@#Vertebral fragility fracture (VFF) is a common fracture related to osteoporosis. However, VFF might be asymptomatic and often occurs in patients without osteoporosis. Therefore, we investigated the characteristics of age-related VFF and their correlation with bone mineral density (BMD). Furthermore, we analyzed other factors affecting VFF @*Methods@#Medical records from a single center were retrospectively reviewed for 2,216 patients over 50 years old with vertebral fractures conservatively treated from 2005 to 2016. Patients' age, gender, body mass index (BMI), BMD, fracture level, previous vertebral fractures, and anti-osteoporosis medications were obtained. Patients were divided into fragilityon-fragility groups and age sub-groups. The odds ratio for VFF in relation to BMD was evaluated. We also identified other predictive factors for VFF by age groups. @*Results@#The fragility group had a higher women ratio, older age, lower BMI, lower BMD, and greater incidence of previous vertebral fractures than the non-fragility group. VFFs were seen in 41.18% of normal BMD patients aged 50–59 and 67.82% of those aged 60–69. The proportion of VFFs increased with age in all WHO osteoporosis classifications. Patients with osteopenia and osteoporosis were 1.57 and 2.62 fold more likely to develop VFFs than normal BMD. In the younger group (under 70), age, women, BMD, and previous vertebral fracture were significant factors affecting VFF, and in the older group (70 and over), age, women, and BMD were factors. In the fragility group, anti-osteoporosis medication rates were 25.08% before and 45.96% after fracture. @*Conclusion@#Considerable VFFs occurred in the younger age groups without osteoporosis and age itself was another important predictor of VFF especially in older age groups. The discrepancy between the incidence of VFF and BMD suggests the necessity of supplemental screening factors and anti-osteoporosis treatment guidelines using only BMD should be reconsidered.

5.
Asian Spine Journal ; : 694-701, 2020.
Article | WPRIM | ID: wpr-830898

ABSTRACT

Over the past few decades, interest in minimally invasive spine surgery (MISS) has increased tremendously due to its core principle of minimizing approach-related injury while providing outcomes similar to traditional open spine procedures. With technical and technological advancements, MISS has expanded its utility not only to simple spinal stenosis, but also to complex spinal pathologies such as metastasis, trauma, or adult spinal deformity. In this article, we review the techniques and technology in MISS and discuss the indications, benefits, and limitations of MISS.

6.
Clinics in Orthopedic Surgery ; : 482-489, 2019.
Article in English | WPRIM | ID: wpr-763600

ABSTRACT

BACKGROUND: Recently, biplanar fluoroscopy is used to evaluate the cervical kinematics, especially to locate the instant center of rotation (ICR) during in vivo motion. This study aims to ascertain the ICR at each cervical segment in the sagittal plane during dynamic motion and assess the differences from previous studies. METHODS: While three healthy subjects were performing full flexion-extension, two oblique views aligned horizontally and angled at approximately 55° were obtained by biplanar fluoroscopy. The minimum degree to detect significant movement in a helical axis model was set at 2°, and anterior-posterior and superior-inferior locations of each ICR were defined. To evaluate the possible distribution area and overlapping area of the ICR with disc space, we drew a circle by using the calculated distance between each coordination and the mean coordination of ICR as the radius. RESULTS: During flexion-extension motion, the mean superior-inferior location of the ICR became progressively more superior, except the C5–6 segment (p = 0.015), and the mean anterior-posterior location of the ICR became progressively more anterior without exception from C2–3 to C6–7 segments, but anterior-posterior ICR locations were not significantly different among segments. The overlapping area with the distribution circle of ICR was mainly located in the posterior half in the C3–4 segment, but the overlapping area was about 80% of the total disc space in C4–5 and C6–7 segments. The overlapping was more noticeable in the lower cervical segments after exclusion of the outlier data of the C5–6 segment in subject 1. CONCLUSIONS: The ICR in the cervical spine showed a trend of moving progressively more superiorly and anteriorly and the disc space overlapping the distribution circle of ICR increased along the lower motion segments except the C5–6 segment. These findings could provide a good basis for level-specific cervical arthroplasty designs.


Subject(s)
Arthroplasty , Biomechanical Phenomena , Fluoroscopy , Healthy Volunteers , Radius , Spine
7.
Asian Spine Journal ; : 661-674, 2017.
Article in English | WPRIM | ID: wpr-79451

ABSTRACT

Systematic literature review. To review the evidence from high-quality studies regarding the treatment of neuropathic pain originating specifically from spinal disorders. In general, treatment guidelines for neuropathic pain cover all its various causes, including medical disease, peripheral neuropathy, and cancer. However, the natural history of neuropathic pain originating from spinal disorders may differ from that of the pain originating from other causes or lesions. An expert research librarian used terms related to neuropathic pain and spinal disorders, disc herniation, stenosis, and spinal cord injury to search in MEDLINE, Embase, and Cochrane CENTRAL for primary research from January 2000 to October 2015. Among 2,313 potential studies of interest, 25 randomized controlled trials (RCTs) and 21 systematic reviews (SRs) were included in the analysis. The selection was decided based on the agreement of two orthopedic surgeons. There was a lack of evidence about medication for radiculopathy arising from disc herniation and stenosis, but intervention procedures, including epidural block, showed positive efficacy in radiculopathy and also limited efficacy in spinal stenosis. There was some evidence based on the short-term follow-up regarding surgery being superior to conservative treatments for radiculopathy and stenosis. There was limited evidence regarding the efficacy of pharmacological and electric or magnetic stimulation therapies for neuropathic pain after spinal cord injury. This review of RCTs and SRs with high-quality evidence found some evidence regarding the efficacy of various treatment modalities for neuropathic pain related specifically to spinal disorders. However, there is a need for much more supportive evidence.


Subject(s)
Humans , Constriction, Pathologic , Follow-Up Studies , Librarians , Magnetic Field Therapy , Natural History , Neuralgia , Orthopedics , Peripheral Nervous System Diseases , Radiculopathy , Spinal Cord Injuries , Spinal Stenosis , Surgeons
SELECTION OF CITATIONS
SEARCH DETAIL