Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Year range
1.
Kinesiologia ; 43(1): 67-72, 20240315.
Article in Spanish, English | LILACS-Express | LILACS | ID: biblio-1552614

ABSTRACT

Los sistemas de Cánula nasal de alto flujo (CNAF) han sido ampliamente utilizados en el campo clínico como soporte no invasivo en el manejo de la falla respiratoria aguda (sobre todo hipoxémica) y cuidados post extubación. Clínica y fisiológicamente, las cánulas nasales de alto flujo son capaces de entregar un flujo de oxigeno alto que, debido a que ese gas se encuentra optimamente humidificado y calefaccionado, permite una mejor tolerancia por parte del paciente al ser comparada con las cánulas de oxigeno tradicionales. Por otra parte, este alto. Flujo es capaz de generar una presión positiva al final de la espiración (CPAP) en la vía área y favorecer tanto en barrido de dióxido de carbono (CO2) desde la vía aérea superior, lo que disminuye el trabajo respiratorio del paciente y mejora su confort.. Sin embargo; aún existe un alto porcentaje de pacientes que fracasan la terapia con CNAF y requiere soportes mas complejos como la ventilación mecánica, ya sea imvasiva o no. Estos resultados con la terapia CNAF pueden ser influidos por aspectos técnicos como, por ejemplo, la turbulencia que pueden generar estos sistemas a nivel de la región nasal. Por esta razón se han desarrollado nuevas tecnologías en el diseño y uso de interfaces para suministrar este alto flujo. Una de estas innovaciones es el uso de cánulas asimétricas, las que potencian los beneficios fisiológicos que entrega una cánula de alto flujo convencional. La presente revisión pretende exponer las principales diferencias que presenta el sistema de alto flujo convencional versus la nueva interface asimétrica.


High-flow nasal cannula (HFNC) systems have been widely used in the clinical field as non-invasive support in the management of acute respiratory failure (especially hypoxemic) and post-extubation care. Clinically and physiologically, high flow nasal cannulas are capable of delivering a high flow of oxygen which, because this gas is optimally humidified and heated, allows better tolerance by the patient when compared to traditional oxygen cannulas. . On the other hand, this high. Flow is capable of generating positive pressure at the end of expiration (CPAP) in the airway and favoring the sweep of carbon dioxide (CO2) from the upper airway, which reduces the patient's respiratory work and improves their comfort. .. However; There is still a high percentage of patients who fail therapy with HFNC and require more complex supports such as mechanical ventilation, whether invasive or not. These results with HFNC therapy can be influenced by technical aspects such as, for example, the turbulence that these systems can generate in the nasal region. For this reason, new technologies have been developed in the design and use of interfaces to provide this high flow. One of these innovations is the use of asymmetric cannulas, which enhance the physiological benefits provided by a conventional high-flow cannula. The present review aims to expose the main differences that the conventional high flow system presents versus the new asymmetric interface.

2.
Kinesiologia ; 42(2): 70-77, 20230615.
Article in Spanish, English | LILACS-Express | LILACS | ID: biblio-1552461

ABSTRACT

Introducción. Introducción. El uso de humidificadores de burbuja asociados a equipos de oxigenoterapia es una práctica común en los centros hospitalarios de nuestro país. Sin embargo, no se ha evaluado el aporte real de humedad que entregan estos equipos cuando son usados con sistemas de concentración variable a distintas concentraciones de oxígeno. Además, se han descrito problemas de funcionamiento en la entrega de oxígeno cuando se han ocupado este tipo de humidificador. Objetivo. Determinar el aporte real de humedad que entregan los humidificadores de burbuja al ser usados con sistemas de oxigenoterapia de concentración variable. Métodos. Se evaluaron 10 humidificadores de burbuja, marca Hudson RCI®, con válvula liberadora de presión, los cuales se conectaron a un sistema de oxigenoterapia de concentración variable (Marca Hudson RCI®, modelo MULTI-VENT). La medición de la humedad relativa (HR) se realizó en una cámara de acrílico, donde se conectó el inyector del sistema de oxigenoterapia. Para medir H.R. y temperatura se utilizó un higrómetro digital (Veto®, Italia) y un higrómetro análogo (Hygromat®, Alemania). Cada medición requirió un tiempo de 5 minutos para lograr un valor estable. Se realizaron mediciones de la humedad relativa y temperatura entregada por este sistema, con y sin humidificador, a concentraciones de oxígeno de 0.24, 0.26, 0.28, 0.3, 0.35, 0.4 y 0.5. Resultados. Para las la temperatura, no hubo diferencias entre las mediciones realizadas con y sin humidificador de burbuja. Para la humedad relativa, sólo hubo diferencias estadísticamente significativas a concentraciones de oxígeno altas (> 0.35), pero con escaso cambio en la entrega de humedad absoluta. Cuando se utilizó flujos operativos ≥ 6 L/min se activó la válvula liberadora de presión del humidificador. Conclusión. El uso de humidificadores de burbuja asociados a sistemas de oxigenoterapia de concentración variable no genera un aumento significativo de la humedad entregada a concentraciones bajas de oxigeno, por lo cual se podría prescindir de su uso.


Background. The use of bubble humidifiers associated with oxygen therapy equipment is a common practice in hospitals in our country. However, the real contribution of humidity delivered by these equipments when used with variable concentration systems at different oxygen concentrations has not been evaluated. In addition, operating problems have been described in the delivery of oxygen when this type of humidifier has been used. Objetive. Determine the real contribution of humidity delivered by bubble humidifiers when used with variable concentration oxygen therapy systems. Methods. 10 Hudson RCI® brand bubble humidifiers with a pressure release valve were evaluated, which were connected to a variable concentration oxygen therapy system (Hudson RCI® brand, MULTI-VENT model). The relative humidity (RH) was measured in an acrylic chamber, where the injector of the oxygen therapy system was connected. To measure R.H. and temperature, a digital hygrometer (Veto®, Italy) and an analog hygrometer (Hygromat®, Germany) were used. Each measurement required a time of 5 minutes to achieve a stable value. Measurements of the relative humidity and temperature delivered by this system were made, with and without a humidifier, at oxygen concentrations of 0.24, 0.26, 0.28, 0.3, 0.35, 0.4 and 0.5. Results. For temperature, there were no differences between the measurements made with and without a bubble humidifier. For relative humidity, there were only statistically significant differences at high oxygen concentrations (> 0.35), but with little change in absolute humidity delivery. When operating flows ≥ 6 L/min were used, the humidifier pressure relief valve was activated. Conclusion. The use of bubble humidifiers associated with variable concentration oxygen therapy systems does not generate a significant increase in the humidity delivered at low oxygen concentrations, so their use could be dispensed with.

3.
Kinesiologia ; 41(2): 101-107, 15 jun 2022.
Article in Spanish, English | LILACS-Express | LILACS | ID: biblio-1552395

ABSTRACT

Introducción. La pandemia por coronavirus trajo consigo una modificación y una reestructuración de las unidades de cuidados intensivos(UCI). Además se produjo un cambio en el perfil de pacientes que ingresan y egresan en estas unidades. Objetivo. Valorar el impacto de la presente pandemia en el perfil de ingreso y egreso de pacientes en UCI según escala de categorización kinesiológica de la unidad. Métodos. Estudio observacional descriptivo que incluyó 50 sujetos de UCI que contaran con escala de categorización kinesiológica (ECK) al ingreso y egreso de la unidad. La ECK contemplo 3 item de evaluación: Función ventilatoria, manejod e secreciones, grado de cooperación y nivel de actividad. El registro de la ECK se planteó de manera retrospectiva para los periodos Julio-agosto 2018 (prepandemia) y Julio - Agosto 2020 (pandemia). Se utilizó estadística descriptiva, utilizando porcentaje y/o promedio para cada variable según corresponda. Resultados. Al observar la función ventilatoria, el requerimiento de soporte ventilatorio varió de un 64% a un 16% pre ­ pandemia, y de un 100% a un 88% durante la pandemia. Respecto al manejo de secreciones, se observó que los sujetos con tos efectiva varío desde un 60% a un 22% en el periodo pandemia Por otra parte, los pacientes que requirieron succión traqueal de manera constante en pandemia, se mantuvo. entre un 88% a un 92% durante la estadía en UCI. En relación al grado de cooperación, un 78% de los pacientes con COVID-19 ingresó con una dependencia severa o nula cooperación, y al momento del egreso de UCI un 54% se mantenía en la misma condición. Respecto al nivel de actividad, durante el periodo pandemia, un 100% de los ingresos y un 96% de los egresos presentó dependencia total. Conclusión. La pandemia causada por SARS-CoV-2 ha influido directamente en el perfil de ingreso y egreso de pacientes UCI, lo cual enfrentó al personal de salud a un aumento considerable en la carga de trabajo.


Introduction. The coronavirus led to a modification and a building of new intensive care units (ICU). In addition, there was a change in the profile of patients admitted and discharged from these units. Objetive. Assess the impact of this pandemy on the admission and discharge profile of patients in the ICU according to a kinesiological categorization scale of the unit. Methods. Descriptive observational study that included 50 ICU subjects who had a Kinesiology Categorization Scale (ECK) at admission and discharge from the unit. The ECK contemplates 3 evaluation elements: ventilatory function, management and secretions, degree of cooperation and level of activity. The ECK registry was considered retrospectively for the periods July-August 2018 (pre-pandemy) and July-August 2020 (pandemy). Descriptive statistics was developed, using percentage and/or average for each variable as appropriate. Results: Looking at ventilatory function, the requirement for ventilatory support varied from 64% to 16% pre-pandemic, and from 100% to 88% during the pandemic. Regarding the management of secretions, it was shown that the subjects with effective cough varied from 60% to 22% in the pandemic period. On the other hand, the patients who required tracheal suctioning constantly in the pandemic were maintained. between 88% and 92% during the ICU stay. Regarding the degree of cooperation, 78% of the patients with COVID-19 were admitted with a severe dependency or no cooperation, and at the time of discharge from the ICU, 54% were pressed in the same condition. Regarding the level of activity, during the pandemic period, 100% of income and 96% of expenses presented total dependency. Conclusion. The pandemy caused by SARS-CoV-2 has directly influenced the admission and discharge profile of ICU patients, which confronted health personnel with a considerable increase in workload.

SELECTION OF CITATIONS
SEARCH DETAIL