Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add filters








Year range
1.
Radiol. bras ; 39(3): 167-174, maio-jun. 2006. tab, ilus
Article in Portuguese | LILACS | ID: lil-455877

ABSTRACT

OBJETIVO: Comparar os aparelhos de ressonância magnética de baixo campo e de alto campo para estudo da cartilagem articular da patela. MATERIAIS E MÉTODOS: Foi realizado estudo usando as seqüências GRE 2D, GRE 3D, FSE T2 e STIR (baixo campo) e TSE T2 SPIR. Cada seqüência foi analisada separadamente para o estudo da cartilagem, sem o conhecimento dos dados do paciente e do resultado das outras seqüências, sendo atribuído grau de lesão de 0 a 3 e descrita a sua localização. Os resultados de concordância e discordância foram analisados pelos testes de Kappa e McNemar. RESULTADOS: Na faceta medial houve baixas concordâncias e as discordâncias mostraram significativa superestimação. Na faceta lateral houve boas concordâncias e as discordâncias não foram significativas. No ápice houve boas concordâncias e as discordâncias mostraram significativa subestimação. CONCLUSÃO: A seqüência STIR teve a melhor concordância com a seqüência TSE T2 SPIR. Lesões de alto grau são mais bem caracterizadas pelas seqüências do aparelho de baixo campo. Areas de aumento de sinal dificultam o estudo da cartilagem da faceta medial da patela no aparelho de baixo campo.


OBJECTIVE: To compare the performance of low-field-strength and high-field-strength magnetic resonance imaging equipments for evaluation of the patella articular cartilage. MATERIALS AND METHODS: The study was developed using GRE 2D, GRE 3D, FSE T2, STIR sequences (low-field) and TSE T2 SPIR sequence. Each sequence has been separately analyzed for evaluation of the cartilage without knowledge of other sequences results or any patients data; the lesion was assigned a grade from 0 to 3 and had its location defined. Agreement and disagreement results were analyzed by Kappa and McNemar tests. RESULTS: Medial facet has presented low agreement index and disagreements showed to be significantly overestimated. Lateral facet has presented a reasonable agreement index and disagreement index was not significant. Medial ridge has presented a reasonable agreement index and disagreement index has showed to be underestimated. CONCLUSION: The STIR sequence versus TSE T2 SPIR sequence has presented the higher agreement index. High grade lesions are better characterized by low-field-strength magnetic resonance imaging equipment sequences. Areas of increased signal intensity make difficult the study of the patella medial facet cartilage in low-field-strength equipment.


Subject(s)
Humans , Male , Female , Adolescent , Adult , Middle Aged , Chondromalacia Patellae/diagnosis , Chondromalacia Patellae/pathology , Equipment and Supplies , Magnetic Resonance Imaging , Comparative Study , Magnetic Resonance Imaging/trends , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL