Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
1.
Afr. j. lab. med. (Print) ; 11(1): 1-9, 2022. tables, figures
Article in English | AIM | ID: biblio-1379112

ABSTRACT

Background: The Northern Cape is South Africa's largest province with an HIV prevalence of 7.1% versus a 13.5% national prevalence. CD4 testing is provided at three of five National Health Laboratory Service district laboratories, each covering a 250 km precinct radius. Districts without a local service report prolonged CD4 turn-around times (TAT).Objective: This study documented the impact of a new CD4 laboratory in Tshwaragano in the remote John Taolo Gaetsewe district of the Northern Cape, South Africa.Methods: CD4 test volumes and TAT (total, pre-analytical, analytical, and post-analytical) data for the Northern Cape province were extracted for June 2018 to October 2019. The percentage of CD4 results within the stipulated 40-h TAT cut-off and the median and 75th percentiles of all TAT parameters were calculated. Pre-implementation, samples collected at Tshwaragano were referred to Kimberley or Upington, Northern Cape, South Africa.Results: Pre-implementation, 95.4% of samples at Tshwaragano were referred to Kimberley for CD4 testing (36.3% of Kimberley's test volumes). Only 7.5% of Tshwaragano's total samples were referred post-implementation. The Tshwaragano laboratory's CD4 median total TAT decreased from 24.7 h pre-implementation to 12 h post-implementation (p = 0.003), with >95.0% of results reported within 40 h. The Kimberley laboratory workload decreased by 29.0%, and testing time significantly decreased from 10 h to 4.3 h.Conclusion: The new Tshwaragano CD4 service significantly decreased local TAT. Upgrading existing community laboratories to include CD4 testing can alleviate provincial service load and improve local access, TAT and efficiency in the centralised reference laboratory


Subject(s)
Humans , Male , Female , CD4 Antigens , HIV , Allergy and Immunology , Exercise Test , Hospitals, District , Laboratories , Operations Research
2.
Article in English | AIM | ID: biblio-1272208

ABSTRACT

Background: Panel tests are a predetermined group of tests commonly requested together to provide a comprehensive and conclusive diagnosis; for example; liver function test (LFT). South African HIV antiretroviral treatment (ART) guidelines recommend individual tests for toxicity monitoring over panel tests. In 2008; the National Health Laboratory Services (NHLS) request form was redesigned to list individual tests instead of panel tests and removed the 'other tests' box option to facilitate efficient ART laboratory monitoring.Objectives: This study aimed to demonstrate changes in laboratory expenditure; for individual and panel tests; for ART toxicity monitoring.Method: NHLS Corporate Data Warehouse (CDW) data were extracted for HIV conditional grant accounts to assess ART toxicity monitoring laboratory expenditure between 2010/2011 and 2014/2015. Data were classified based on the tests requested; as either panel (LFT or urea and electrolytes) or individual (alanine transaminase or creatinine) tests.Results: Expenditure on panel tests reduced from R340 million in 2010/2011 to R140m by 2014/2015 (reduction of R204m) and individual test expenditure increased from R34m to R76m (twofold increase). A significant reduction in LFT panel expenditure was noted; reducing from R322m in 2010/2011 to R130m in 2014/2015 (60% reduction).Conclusion: Changes in toxicity monitoring guidelines and the re-engineering of the NHLS request form successfully reduced expenditure on panel tests relative to individual tests. The introduction of order entry systems could further reduce unnecessary laboratory expenditure


Subject(s)
Compliance , HIV Infections/therapy , Health Expenditures , Laboratories
3.
Article in English | AIM | ID: biblio-1257336

ABSTRACT

Background: Prostate cancer (PCa) is a leading male neoplasm in South Africa.Objective: The aim of our study was to describe PCa using Systemized Nomenclature of Medicine (SNOMED) clinical terms codes, which have the potential to generate more timely data.Methods: The retrospective study design was used to analyse prostate biopsy data from our laboratories using SNOMED morphology (M) and topography (T) codes where the term 'prostate' was captured in the narrative report. Using M code descriptions, the diagnosis, sub-diagnosis, sub-result and International Classification of Diseases for Oncology (ICD-O-3) codes were assigned using a lookup table. Topography code descriptions identified biopsies of prostatic origin. Lookup tables were prepared using Microsoft Excel and combined with the data extracts using Access. Contingency tables reported M and T codes, diagnosis and sub-diagnosis frequencies.Results: An M and T code was reported for 88% (n = 22 009) of biopsies. Of these, 20 551 (93.37%) were of prostatic origin. A benign diagnosis (ICD-O-3:8000/0) was reported for 10 441 biopsies (50.81%) and 45.26% had a malignant diagnosis (n = 9302). An adenocarcinoma (8140/3) sub-diagnosis was reported for 88.16% of malignant biopsies (n = 8201). An atypia diagnosis was reported for 760 biopsies (3.7%). Inflammation (39.03%) and hyperplasia (20.82%) were the predominant benign sub-diagnoses.Conclusion: Our study demonstrated the feasibility of generating PCa data using SNOMED codes from national laboratory data. This highlights the need for extending the results of our study to a national level to deliver timeous monitoring of PCa trends


Subject(s)
Adenocarcinoma , Biopsy , Prostate , Prostatic Neoplasms , South Africa , Topography, Medical
SELECTION OF CITATIONS
SEARCH DETAIL