ABSTRACT
STUDY DESIGN: Retrospective study. PURPOSE: The study aims to assess the effectiveness and safety of radiofrequency (RF) kyphoplasty in the treatment of vertebral compression fractures (VCFs) in osteoporotic patients. OVERVIEW OF LITERATURE: Vertebroplasty and balloon kyphoplasty are established procedures for the treatment of osteoporotic VCFs. However, RF kyphoplasty is a new method which controls cement viscosity. METHODS: We reviewed the results of 41 consecutive patients with 23 thoracic and 38 lumbar VCFs who underwent RF kyphoplasty. The study population included 14 males (34%) and 27 females (66%). The mean patients age was 78 years (range, 51–89 years), and the follow-up period was 1 year. Clinical and radiographic analyses were performed during follow-up at 6 weeks, 6 months, and 1 year. All patients were assessed clinically pre- and postoperative using the Visual Analog Scale (VAS) and Oswestry Disability Index (ODI). Radiological assessment with X-ray in two views preoperatively, postoperatively, and during follow-up visits. RESULTS: The mean preoperative VAS was 8.7 (range, 5–10; standard deviation [SD], 1.2). Postoperatively, VAS decreased by 3.3 (range, 2–5; SD, 0.9). At the end of the follow-up, VAS decreased by 1.22 (range, 0–7; SD, 1.6). The mean preoperative ODI score was 85.9, decreasing to 9.6 postoperatively and improving to 18.4 during the 1-year follow-up. The mean local kyphotic angle was 9.04° before the procedure and decreased by a mean of 6.16° after the operation and at the end of the follow-up. The mean increase in vertebral body height was 3.3 mm postoperatively and after 1-year follow-up. The rate of cement leakage was 8% (five out of 61 levels of fracture). CONCLUSIONS: RF kyphoplasty is a safe and effective augmentation technique with an advantage of controlling the cement viscosity to minimize the risk of cement leakage. It also shortens operation time.