Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 50
Filter
1.
Yonsei Medical Journal ; : 19-26, 2024.
Article in English | WPRIM | ID: wpr-1045620

ABSTRACT

Purpose@#There are few studies in the literature on the dosage of statin that equivalently reduces low-density lipoprotein cholesterol (LDL-C) compared to an ezetimibe combination and whether such regimens have differences in safety. We compared the lipidmodifying efficacy and safety of 5 mg rosuvastatin/10 mg ezetimibe to those of 20 mg rosuvastatin. @*Materials and Methods@#A literature search was conducted using the PubMed, EMBASE, Cochrane, Web of Sciences, and SCOPUS databases up to December 2021. Human studies investigating the two aforementioned regimens with a randomized controlled design were selected. Outcome variables included the percentage reduction in LDL-C and other lipid parameters and rates of composite adverse events (AEs), including muscle-related symptoms. A random-effects meta-analysis was performed after heterogeneity testing between studies. @*Results@#Seven studies were included in this meta-analysis. The percentage LDL-C reduction did not differ between the combination and monotherapy groups [standardized mean difference (SMD) 0.08; 95% confidence interval (CI) -0.09 to 0.26; p=0.35]. The risk of composite AEs (odds ratio 0.50; 95% CI 0.15 to 1.72; p=0.27) of the combination was not different compared to the monotherapy group. The percentage of total cholesterol reduction was greater in the combination group (SMD 0.22; p=0.02), whereas that of triglyceride reduction and high-density lipoprotein cholesterol elevation did not differ between the two groups. @*Conclusion@#This meta-analysis showed that 5 mg rosuvastatin/10 mg ezetimibe had largely comparable lipid-modifying efficacy and tolerability as 20 mg rosuvastatin.

2.
Yonsei Medical Journal ; : 342-348, 2022.
Article in English | WPRIM | ID: wpr-927133

ABSTRACT

Purpose@#Angiotensin-converting enzyme inhibitors (ACEIs) are medications generally prescribed for patients with high cardiovascular risk; however, they are suboptimally used due to frequent adverse events (AEs). The present study aimed to identify and replicate the genetic variants associated with ACEI-related AEs in the Korean population. @*Materials and Methods@#A two-stage approach employing genome-wide association study (GWAS)-based discovery and replication through target sequencing was used. In total, 1300 individuals received ACEIs from 2001 to 2007; among these, 228 were selected for GWAS. An additional 336 patients were selected for replication after screening 1186 subjects treated from 2008 to 2018.Candidate genes for target sequencing were selected based on the present GWAS, previous GWASs, and data from the PharmGKB database. Furthermore, association analyses were performed between no AE and AE or cough groups after target sequencing. @*Results@#Five genes, namely CRIM1, NELL1, CACNA1D, VOPP1, and MYBPC1, were identified near variants associated with ACEIrelated AEs. During target sequencing of 34 candidate genes, six single-nucleotide polymorphisms (SNPs; rs5224, rs8176786, rs10766756, rs561868018, rs4974539, and rs10946364) were replicated for association with all ACEI-related AEs. Four of these SNPs and rs147912715 exhibited associations with ACEI-related cough, whereas four SNPs (rs5224, rs81767786, rs10766756, and rs4974539 near BDKRB2, NELL1, NELL1 intron, and CPN2, respectively) were significantly associated with both categories of AEs. @*Conclusion@#Several variants, including novel and known variants, were successfully replicated and found to have associations with ACEI-related AEs. These results provide rare and clinically relevant information for safer use of ACEIs.

3.
Article in English | WPRIM | ID: wpr-997476

ABSTRACT

The dramatic spread of Coronavirus Disease 2019 (COVID-19) has profound impacts on every continent and life. Due to humanto-human transmission of COVID-19, nuclear medicine staffs also cannot escape the risk of infection from workplaces. Everystaff in the nuclear medicine department must prepare for and respond to COVID-19 pandemic which tailored to the characteristicsof our profession. This article provided the guidance prepared by the Korean Society of Nuclear Medicine (KSNM) incooperation with the Korean Society of Infectious Disease (KSID) and Korean Society for Healthcare-Associated InfectionControl and Prevention (KOSHIC) in managing the COVID-19 pandemic for the nuclear medicine department.We hope that thisguidance will support every practice in nuclear medicine during this chaotic period.

4.
Article in English | WPRIM | ID: wpr-997503

ABSTRACT

Purpose@#Single-photon emission computed tomography/computed tomography (SPECT/CT) is an advanced hybrid nuclear medicine technology that generates both functional and anatomical images in a single study. As utilization of SPECT/CT in Korea has been increasing, the purpose of this study was to survey its application of cardiac and skeletal SPECT/CT imaging for protocol optimization. @*Methods@#We surveyed CT protocols established for cardiac and skeletal SPECT/CT. We searched the guidelines for the CT protocols for SPECT/CT and reviewed the literature recently published. @*Results@#Among 36 hybrid SPECT scanners equipped with four or more multi-channel detector CTs (MDCTs), 18 scanners were used to perform cardiac studies at both very low current CT (30–80 mA; 11.1%) and ultra-low current CT (13–30 mA; 88.9%). Among the 33 canners, very low current (≤ 80 mA) CT or low current CT (80–130 mA) was used in 23.5%, and 41.8% for spine disorders, and in 36.4% or 30.3% for foot/ankle disorders, respectively. In the CT reconstructions, slice thickness of 5 mm for cardiac studies was most commonly used (94.4%); thinner slices (0.6–1.0 mm) for spine and foot/ankle studies were used in 24.2% and 45.5%, respectively. We also reviewed the international guidelines. @*Conclusions@#The results and current recommendations will be helpful for optimizing CT protocols for SPECT/CT. Optimization of SPECT/CT protocols will be required for generating the proper strategy for the specific lesions and clinical purpose.

5.
Article in English | WPRIM | ID: wpr-997515

ABSTRACT

Purpose@#This study aimed to construct a database of the effective doses (ED) from F-18 fluorodeoxyglucose (FDG) torso positron emission tomography/computed tomography (PET/CT) in Korea to provide data that supports the reduction of the CT dose of PET/CT and optimization of PET/CT protocols in Korea. @*Methods@#We investigated data of ED and CT parameters of FDG PET/CT. The data were analyzed by body weight groups. @*Results@#A total of 31 hospitals participated in the survey (99 adults). The mean total EDs (± SD) were 8.77 ± 2.76, 10.93 ± 3.14, and 12.57 ± 3.79 mSv for the 55-, 70-, and 85-kg groups, respectively. The FDG EDs were 4.80 ± 0.98, 6.05 ± 1.15, and 6.89 ± 1.52 mSv, and the CT EDs were 4.00 ± 2.12, 4.88 ± 2.51, and 5.68 ± 2.89 mSv, respectively. Of the enrolled hospitals, 54.5% used ultra-low-dose CT protocols, and their CT ED was significantly lower than low-dose CT group in all groups (2.9 ± 1.0, 3.2 ± 1.1, and 3.3 ± 1.0 mSv vs. 6.6 ± 1.6, 7.2 ± 2.1, and 7.9 ± 2.2 mSv, all p < 0.001, respectively). In the ultra-low-dose CT group, the CT ED with the iterative reconstruction was significantly lower than that of CT without iterative reconstruction in the 55-kg group (2.4 ± 0.9 vs. 3.3 ± 0.9, p = 0.04). @*Conclusions@#These results and current recommendations can be helpful for optimizing PET/CT diagnostic reference level (DRL) and reducing unnecessary PET/CT radiation exposure.

6.
Article in English | WPRIM | ID: wpr-786987

ABSTRACT

PURPOSE: A low-iodine diet is necessary in patients about to undergo radioiodine therapy for thyroid cancer to decrease the competitive absorption of ingested nonradioactive iodine. This study aimed to assess the iodine concentrations in salts and basic Korean sauces, and to provide fundamental data for guidelines on a low-iodine diet before radioiodine therapy.METHODS: The iodine contents of refined salts, solar sea salts, fish sauces, and commonly used Korean sauces with added refined salt were determined by ICP-MS.RESULTS: The iodine content of refined salts was found to be very low (0.033 ± 0.05 µg/100 g) compared with that of solar sea salts (434 ± 73.6 µg/100 g). The iodine contents of Korean soy sauce, Korean soybean paste, Gochujang seasoned with refined salt were also very low (0.010, 0.044, 0.002 µg/100 g, respectively). However, the mean iodine contents of the shrimp and fish Jeots analyzed in this study were found to be 41.3 ± 4.2 and 24.8 ± 4.5 µg/100 g, respectively.CONCLUSION: This study is the first to investigate the iodine contents of the salts and basic sauces used in Korea. The results show that refined salts and Korean traditional sauces seasoned with them can be safely used in low-iodine diets before radioiodine therapy.


Subject(s)
Humans , Absorption , Diet , Education , Iodine , Korea , Salts , Seasons , Soy Foods , Glycine max , Thyroid Gland , Thyroid Neoplasms
7.
Article in English | WPRIM | ID: wpr-997381

ABSTRACT

PURPOSE@#A low-iodine diet is necessary in patients about to undergo radioiodine therapy for thyroid cancer to decrease the competitive absorption of ingested nonradioactive iodine. This study aimed to assess the iodine concentrations in salts and basic Korean sauces, and to provide fundamental data for guidelines on a low-iodine diet before radioiodine therapy.@*METHODS@#The iodine contents of refined salts, solar sea salts, fish sauces, and commonly used Korean sauces with added refined salt were determined by ICP-MS.@*RESULTS@#The iodine content of refined salts was found to be very low (0.033 ± 0.05 µg/100 g) compared with that of solar sea salts (434 ± 73.6 µg/100 g). The iodine contents of Korean soy sauce, Korean soybean paste, Gochujang seasoned with refined salt were also very low (0.010, 0.044, 0.002 µg/100 g, respectively). However, the mean iodine contents of the shrimp and fish Jeots analyzed in this study were found to be 41.3 ± 4.2 and 24.8 ± 4.5 µg/100 g, respectively.@*CONCLUSION@#This study is the first to investigate the iodine contents of the salts and basic sauces used in Korea. The results show that refined salts and Korean traditional sauces seasoned with them can be safely used in low-iodine diets before radioiodine therapy.

8.
Article in English | WPRIM | ID: wpr-721719

ABSTRACT

Prognosis has not been known for patients with fever of unknown origin (FUO) whose ¹⁸fluoro-deoxyglucose (¹⁸F-FDG) positron emission tomography/computerized tomography (PET/CT) finding is non-diagnostic. A total of eight patients with FUO that underwent ¹⁸F-FDG PET/CT were retrospectively identified January 2016 - June 2017 in a tertiary hospital in Korea. Of these, two patients were diagnosed with microscopic polyangitis and Kikuchi's disease and one patient was transferred to another hospital. Of five patients whose diagnoses were not confirmed, four patients received non-steroidal anti-inflammatory drug and/or low dose steroid and symptoms disappeared. Our study suggests that outcome of patients with FUO whose ¹⁸F-FDG PET/CT finding is non-diagnostic would be favorable.


Subject(s)
Humans , Diagnosis , Electrons , Fever of Unknown Origin , Fever , Histiocytic Necrotizing Lymphadenitis , Korea , Positron Emission Tomography Computed Tomography , Prognosis , Retrospective Studies , Tertiary Care Centers
9.
Article in English | WPRIM | ID: wpr-722224

ABSTRACT

Prognosis has not been known for patients with fever of unknown origin (FUO) whose ¹⁸fluoro-deoxyglucose (¹⁸F-FDG) positron emission tomography/computerized tomography (PET/CT) finding is non-diagnostic. A total of eight patients with FUO that underwent ¹⁸F-FDG PET/CT were retrospectively identified January 2016 - June 2017 in a tertiary hospital in Korea. Of these, two patients were diagnosed with microscopic polyangitis and Kikuchi's disease and one patient was transferred to another hospital. Of five patients whose diagnoses were not confirmed, four patients received non-steroidal anti-inflammatory drug and/or low dose steroid and symptoms disappeared. Our study suggests that outcome of patients with FUO whose ¹⁸F-FDG PET/CT finding is non-diagnostic would be favorable.


Subject(s)
Humans , Diagnosis , Electrons , Fever of Unknown Origin , Fever , Histiocytic Necrotizing Lymphadenitis , Korea , Positron Emission Tomography Computed Tomography , Prognosis , Retrospective Studies , Tertiary Care Centers
10.
Article in English | WPRIM | ID: wpr-66651

ABSTRACT

OBJECTIVES: The purpose of this study was to compare lymph node (LN) staging using ¹⁸F-fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) with contrast-enhancement (CE) PET/CT and contrast-enhanced neck CT (neck CT) in patients with thyroid cancer with level-by-level comparison with various factors. METHODS: This was a retrospective multicenter study. A total of 85 patients were enrolled. Patients who underwent a preoperative evaluation by CE PET/CT and neck CT for thyroid cancer were enrolled. The gold standard for LN was the combination of surgical pathology and clinical follow-up. We compared CE PET/CT with neck CT using a level-by-level method. Factors, including age, sex, camera, arm position, tumor size, extra-thyroidal extension, tumor location, number of primary tumors, primary tumor maximum standardized uptake value, and the interval from scan to operation were also analyzed. RESULTS: Overall accuracy was 81.2% for CE PET/CT and 68.2% for neck CT. CE PET/CT was more sensitive than neck CT (65.8% vs. 44.7%). Also, CE PET/CT showed higher negative predictive value (77.2% vs. 66.1%). CE PET/CT showed good agreement with the gold standard (weighted kappa [κ], 0.7) for differentiating N0, N1a, and N1b, whereas neck CT showed moderate agreement (weighted κ, 0.5). CE PET/CT showed better agreement for the number of levels involved with the gold standard (weighted κ, 0.7) than that of neck CT with the gold standard (weighted κ, 0.5). The accuracies for differentiating N0, N1a, and N1b were 81.2% for CE PET/CT and 68.2% for neck CT. Level-by-level analysis showed that CE PET/CT was more sensitive and has higher negative predictive value for detecting ipsilateral level IV and level VI LNs than neck CT. Other analyzed factors were not related to accuracies of both modalities. CONCLUSION: CE PET/CT was more sensitive and reliable than neck CT for preoperative LN staging in patients with thyroid cancer.


Subject(s)
Humans , Arm , Electrons , Fluorodeoxyglucose F18 , Follow-Up Studies , Lymph Nodes , Methods , Neck , Pathology, Surgical , Positron-Emission Tomography , Positron Emission Tomography Computed Tomography , Retrospective Studies , Thyroid Gland , Thyroid Neoplasms
SELECTION OF CITATIONS
SEARCH DETAIL