ABSTRACT
Objective:To investigate the post-traumatic growth status of tumor patients receiving radiotherapy and analyze its influencing factors, aiming to provide theoretical basis for clinical doctors and nurses to formulate targeted intervention strategies.Methods:A cross-sectional survey of 170 tumor patients receiving radiotherapy admitted to Department of Radiotherapy of Sun Yat-sen Memorial Hospital was conducted by convenience sampling method, general information questionnaire and a post-traumatic growth inventory (PTGI).Results:The average PTGI score of 170 patients was 83.11±16.74, and 141 cases of them had significant post-traumatic growth, accounting for 82.9%(score ≥71). Logistic regression analysis showed that personality type, work status, and the times of hospitalization were the influencing factors of post-traumatic growth (all P<0.05). Conclusions:Tumor patients undergoing radiotherapy obtain a high level of post-traumatic growth. Medical staff should make full use of the patients’ potential for post-traumatic growth and implement interventions as soon as possible to promote the physical and mental health of tumor patients undergoing radiotherapy.
ABSTRACT
Objective To preliminarily investigate the difference of position fixation accuracy between polyurethane styrofoam and vacuum negative pressure pad in intensity-modulated radiation therapy (IMRT) after radical mastectomy for breast cancer.Methods Forty breast cancer patients,who received breast-conserving surgery followed by hyper-fractionated IMRT of the whole breast (42.56 Gy for 16 times) in our hospital between 2017 and 2018 were recruited and randomly divided into the polyurethane styrofoam group and vacuum negative pressure pad group.Before IMRT treatment,the anterior and lateral films of patients were taken with kilovoltage digital radiographs (KVDRs) by Varian Trilogy machine-borne OBI KV image verification system.The KVDRs images were matched with the DRR images reconstructed by the planned system to obtain the setup errors in the left and right,head and foot,and ventral and back directions between two groups.Each patient was verified for 10 times to obtain 400 sets of data.The independent sample t-test was adopted to analyze the setup errors between two groups.The external expansion value of graded setup errors from clinical target volume (CTV) and planned target volume (PTV) was calculated.Results The setup errors in the left and right,head and foot,ventral and back directions between the styrofoam fixation and vacuum pad groups were (1.63± 1.29) mm and (1.83 ± 1.61) mm (P=0.18),(1.46t1.51) mm and (2.26±2.03) mm (P=0.00),and (1.30±1.35) mm and (1.91±1.67) mm (P=0.00),respectively.The external expansion values of setup errors from CTV to PTV were 2.19 mm,2.51 mm,1.57 mm and 2.40 mm,3.97 mm and 2.63 mm,respectively.Conclusion Both two fixation methods meet the clinical requirements.However,the setup accuracy and reproducibility in the polyurethane styrofoam group are better than those in the vacuum negative pressure pad group.
ABSTRACT
Objective@#To preliminarily investigate the difference of position fixation accuracy between polyurethane styrofoam and vacuum negative pressure pad in intensity-modulated radiation therapy (IMRT) after radical mastectomy for breast cancer.@*Methods@#Forty breast cancer patients, who received breast-conserving surgery followed by hyper-fractionated IMRT of the whole breast (42.56 Gy for 16 times) in our hospital between 2017 and 2018 were recruited and randomly divided into the polyurethane styrofoam group and vacuum negative pressure pad group. Before IMRT treatment, the anterior and lateral films of patients were taken with kilovoltage digital radiographs (KVDRs) by Varian Trilogy machine-borne OBI KV image verification system. The KVDRs images were matched with the DRR images reconstructed by the planned system to obtain the setup errors in the left and right, head and foot, and ventral and back directions between two groups. Each patient was verified for 10 times to obtain 400 sets of data. The independent sample t-test was adopted to analyze the setup errors between two groups. The external expansion value of graded setup errors from clinical target volume (CTV) and planned target volume (PTV) was calculated.@*Results@#The setup errors in the left and right, head and foot, ventral and back directions between the styrofoam fixation and vacuum pad groups were (1.63±1.29) mm and (1.83 ±1.61) mm (P=0.18), (1.46±1.51) mm and (2.26±2.03) mm (P=0.00), and (1.30±1.35) mm and (1.91±1.67) mm (P=0.00), respectively. The external expansion values of setup errors from CTV to PTV were 2.19 mm, 2.51 mm, 1.57 mm and 2.40 mm, 3.97 mm and 2.63 mm, respectively.@*Conclusion@#Both two fixation methods meet the clinical requirements. However, the setup accuracy and reproducibility in the polyurethane styrofoam group are better than those in the vacuum negative pressure pad group.
ABSTRACT
Objective@#In order to investigate the clinical features and influence factors for incidence in patients with radiation-induced external auditory canal carcinoma (RIEACC).@*Methods@#The nasopharyngeal carcinoma (NPC) 16 patients who were diagnosised RIEACC after radiotherapy in the Sun Yat-Sen Memorial Hospital of Sun Yat-Sen University from January 1990 to December 2017 were retrospectively analysis. The influence factors analysis were used Logistic regression analysis.@*Results@#Univariate analysis showed that age, somking history, family history of cancer and NPC stage were the influencing factors. Multi-factor logistic regression analysis showed that age, family history of cancer and NPC stage were independent risk factors.@*Conclusions@#RIEACC is rare complication of NPC patients received radiotherapy, which is also a multifactorial outcome. Age, family history of cancer and NPC stage is preliminary the main influencing factor. Although RIEACC has a low incidence, its malignancy should be highly vigilant.
ABSTRACT
Objective@#To develop a simple radiotherapy information system for the developments of multiple hospital areas.@*Methods@#Using C/S+ B/S dual technology architecture, Visual Studio 2015+ C#+ HTML5+ JavaScript+ PostgreSQL9.5 were utilized as the programming tools selected for development. The two-dimensional barcode, intelligent IC card, identity card recognition, face recognition, speech synthesis and other technologies were integrated and applied in the radiotherapy process management. The normal business processes were designed by default automatic processing. Previous multi-step operation was simplified to single-key operation.@*Results@#System development was completed and implemented at the end of 2017, which connected the south and north hospital areas. The system not only resolved the problem that required the doctors to manually input or make telephone call for consulting patients’ data, but also achieved paperless business process in different departments. The outstanding advantage was reflected in the aspects of intelligence and optimization. Approximately 95% of the normal flows could be completed by single-key automatic processing, and the remaining 5% requiring special operations (such as, modification or deletion, etc.) were prompted and restricted to ensure data security and system stability.@*Conclusion@#The application of this system improves the level of information management in the departments and saves the cost of supplies and human resources.
ABSTRACT
Objective To investigate the difference of styrofoam and breast carrier in postposition fixation of intensity-modulated radiotherapy after breast conservative surgery for breast cancer patients.Methods From February 2018 to August 2018,tweenty-four patients with breast cancer in Sun Yet-Sen Memorial Hospital of Sun Yet-sen University were selected for this study,who underwent hypofactionationed radiotherapy after breast conservative surgery with total dose 42.56 Gy/16Fractions.They were randomized into styrofoam test group and breastcarrier control group.Cone beam CT as used to record the positioning error under the directions of left and right (x),head and foot (y),abdomen and back (y) within two groups at the first,third,fifth,seventh,eleventh time before irradiation.Furthermore,the PTV extension margin was calculated and the positioning time of two groups was recorded.Two sets of pendulum errors were analyzed by independent sample T-test,and the outspread value of inter-fractional set up error of the PTV was calculated.Results The errors of the test group and the control group in the direction of x,y,z were as follows:(2.36±1.89) and (2.56±2.05) mm (P=0.49),(1.76± 1.78) and (3.28±2.79) mm (P<0.05),(1.47± 1.49) and (1.73± 1.81) mm (P=0.28).The extension values of inter-fractional set up error of CTV to PTV were 2.97,2.92,2.21 mm and 3.41,4.09,2.59 mm respectively.The time of single positioning was (3.4± 1.1) and (5.5 ± 3.1) min respectively (P=0.01).Conclusion Styrofoam has better positioning accuracy and efficiency compared with breast carrier.
ABSTRACT
Objective In order to investigate the clinical features and influence factors for incidence in patients with radiation-induced external auditory canal carcinoma (RIEACC).Methods The nasopharyngeal carcinoma (NPC) 16 patients who were diagnosised RIEACC after radiotherapy in the Sun Yat-Sen Memorial Hospital of Sun Yat-Sen University from January 1990 to December 2017 were retrospectively analysis.The influence factors analysis were used Logistic regression analysis.Results Univariate analysis showed that age,somking history,family history of cancer and NPC stage were the influencing factors.Multi-factor logistic regression analysis showed that age,family history of cancer and NPC stage were independent risk factors.Conclusions RIEACC is rare complication of NPC patients received radiotherapy,which is also a multifactorial outcome.Age,family history of cancer and NPC stage is preliminary the main influencing factor.Although RIEACC has a low incidence,its malignancy should be highly vigilant.
ABSTRACT
Objective To develop a simple radiotherapy information system for the developments of multiple hospital areas.Methods Using C/S+B/S dual technology architecture,Visual Studio 2015+C#+HTML5+JavaScript+PostgreSQL9.5 were utilized as the programming tools selected for development.The two-dimensional barcode,intelligent IC card,identity card recognition,face recognition,speech synthesis and other technologies were integrated and applied in the radiotherapy process management.The normal business processes were designed by default automatic processing.Previous multi-step operation was simplified to single-key operation.Results System development was completed and implemented at the end of 2017,which connected the south and north hospital areas.The system not only resolved the problem that required the doctors to manually input or make telephone call for consulting patients' data,but also achieved paperless business process in different departments.The outstanding advantage was reflected in the aspects of intelligence and optimization.Approximately 95% of the normal flows could be completed by single-key automatic processing,and the remaining 5% requiring special operations (such as,modification or deletion,etc.) were prompted and restricted to ensure data security and system stability.Conclusion The application of this system improves the level of information management in the departments and saves the cost of supplies and human resources.