China Medical Equipment ; (12): 129-132, 2024.
Article in Chinese | WPRIM | ID: wpr-1026539

ABSTRACT

Objective:To compare the testing effects of different testing methods in the functional inspection of precision surgical scissors and needle holders.Methods:By consulting relevant literature and professional books,three testing methods and materials for precision surgical scissors and needle holders were selected.The cutting performance of the precision surgical scissors were tested by gauze cloth,cotton wool,and silicone film method in the Interlock surgical instrument testing set.The clamping performance of precision needle holder was tested by using light,needle clips,and thread clamping method in the Interlock surgical instrument testing set.100 pieces of precision surgical scissors and needle holders which were qualified for cleaning and disinfection in the hospital were selected for effectiveness testing,and a self-made satisfaction questionnaire to investigate the satisfaction of surgeons with the use of instruments.Results:After 100 precision surgical scissors tested using three methods of gauze,cotton wool,and silicone film,the qualified number of cutting performance was 94,76,and 58,respectively,the difference was statistically significant(x2=36.526,P<0.05).The satisfaction rate of surgeons with the use of precision surgical scissors passed the silicone film test was the highest at 100%,followed by cotton wool cloth at 82.0%,and the gauze method at the worst at 67.0%,the difference was statistically significant(x2=48.439,P<0.05).After 100 precision needle holders were tested by using three methods of light irradiation,needle clamping,and wire clamping,the qualified number of clamping performance was 96,78,and 62,respectively,the difference was statistically significant(x2=38.160,P<0.05).The satisfaction rate of surgeons with the precision needle holders passed the clamp line test was the highest at 100.0%,followed by the clamp needle at 79.0%,and the worst under light at 62.0%,the difference was statistically significant(x2=57.705,P<0.05).Conclusion:The function and quality of precision surgical scissors and needle holders tested by the test objects in Interlock Surgical Instrument Test Suite can objectively and accurately reflect the functional status of surgical scissors and needle holders,provide reference for regular maintenance and upkeep of instruments,and ensure safe use of instruments.

2.
Article in Chinese | WPRIM | ID: wpr-552835

ABSTRACT

[Objective] To observe the clinical effect of digestive ulcer treated with TCM simple somatotype combined with Pantoprazole. [Method] Divide 160 cases into 2 groups;the treatment group 80 cases took TCM simple somatotype combined with Pantoprazole, the control one 80 cases only Pantopra-zole. Both groups had 2 courses, 4w as a course. [Result] Comparing both groups cure effects, the total effective rate was 96.3% for treatment one, and 88.8% for control one, their difference had statistical meaning. [Conclusion] Combination of TCM and WM treating digestive ulcer can improve clinical cure rate and total effective rate, as wel as gastroscope cure rate.

SELECTION OF CITATIONS
SEARCH DETAIL