Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
1.
Full dent. sci ; 6(21): 103-111, dez. 2014. tab, ilus
Article in Portuguese | LILACS, BBO | ID: lil-750189

ABSTRACT

O objetivo do presente estudo foi analisar a rela‡Æo entre os m‚todos utilizados na obten‡Æo da cor dental e acuidade visual. O estudo foi realizado em 43 acadˆmicos do quinto ano do curso de Odontologia - UNOESC - Joa‡aba. Cada entrevistado avaliou a cor dental com o guia de cores Vita 3-D Master e com a escala Vitapan Cl ssica. Um aparelho espectrofot“metro (EasyShade©) foi utilizado como padrÆo para avaliar a escolha da cor pelos entrevistados. O resultado obtido foi avaliado antes e ap¢s os mesmos receberem um treinamento sobre sele‡Æo de cores. Os dados obtidos foram submetidos aos testes estat¡sticos Exato de Fisher e Qui-quadrado, ao n¡vel de significƒncia de 5%. Utilizando-se a escala Vita 3D Master constatou-se que antes do treinamento 4,65% dos entrevistados apresentaram resultado coincidente com oEasyShadee ap¢s o treinamento 39,5% dos entrevistados mostraram coincidˆncia. O aumento da concordƒncia foi significativo (p <0,001). Com a utiliza‡Æo da escala Vitapan Cl ssica, antes do treinamento, 20,9% apresentaram coincidˆncia e ap¢s o treinamento 41,9% apresentaram coincidˆncia entre as escalas e o espectrofot“metro, sendo este resultado significativo (p = 0,037). Os resultados tamb‚m mostraram que seguindo a t‚cnica correta nÆo houve aumento do tempo gasto para sele‡Æo de cor e nem houveram diferen‡as significativas de resultado em rela‡Æo ao sexo masculino e feminino. Ao serem utilizadas de maneira correta, ambas as escalas apresentaram uma quantidade semelhante de acertos na escolha da cor.


The aim of the current study was to analyze the relation between the applied methods and visual acuity on the obtainment of the dental color. The study was carried out with 43 students from the fifth year of the Dentistry Course (UNOESC – Joa‡aba). Each one of them evaluated the dental color with the scale Vita 3-D and the scale Vitapan Cl ssica. A spectro photometer device (EasyShade©) was used as a pattern to evaluate the color chosen by the students. The obtained result was assessed before and after they received training on selection of colors. The obtained data were submitted to the Fisher’s exact test and Chi-square test, signification level of 5%. Using Vita 3D scale it was observed that, before training 4.65% of the students obtained results in accordance to EasyShade while after treatment this number increased to 39.5%. The increase of the accordance was significant (p <0.001). For Vitapan Classical Scale the results in line with EasyShade were of 20.9% before training and 41.9% after training, with significant difference (p = 0.037). The results also showed that using proper technique there was no increase in the time spent on color selection, nor significant differences regarding the gender of the patients. When properly used, both scales presented accuracy on the choice of the color.(au)


Subject(s)
Humans , Male , Female , Color , Color Perception , Patient Satisfaction , Visual Acuity , Chi-Square Distribution , Spectrophotometry
2.
Int. j. odontostomatol. (Print) ; 8(1): 161-165, Apr. 2014. ilus
Article in Spanish | LILACS | ID: lil-711562

ABSTRACT

El objetivo de esta investigación es identificar las tensiones presentes en tornillos de osteosíntesis utilizados en la fijación de la osteotomía sagital de rama mandibular (OSRM). Se utilizaron dos modelos de OSRM realizados con resina fotoelástica donde el grupo 1 presentaba una osteotomía basilar recta mientras que el grupo 2 presentaba una osteotomía basilar angulada; en ambos se utilizo el sistema de L invertido para la osteosíntesis con tornillos 2.0 de 13 mm de longitud. Posteriormente el sistema fue instalado en un pilar sobre la maquina Instrom, donde se aplico una carga vertical de 1 mm/minuto hasta conseguir el desplazamiento de 3 mm; el punto de carga estuvo en la fosa central del primer molar. La distribución de franjas mostro mayor tensión en el tornillo mas próximo de la osteotomía en ambos grupos; en el grupo 2 se produjo una diseminación de fuerzas levemente hacia la basilar y en el grupo 1 se mantuvo la diseminación a través de la línea oblicua. Se puede concluir que ambas osteotomías mandibulares son eficientes en la distribución de cargas y que no se observan diferencias cualitativas entre tornillos en términos de cantidad de diseminación de energía


The aim of this research was to analyzed the tension in osteosynthesis screw used for fixation of sagittal split ramus osteotomy (SSRS). Was used two model of SSRS made in photoelastic resin; in one of them was include a basilar osteotomy and the another one only SSRS without basilar osteotomy; for both system was used inverted L osteosynthesis with 13 mm screw of 2.0 system. Posteriorly, the hemimandible was installed in Instrom machine with a vertical load of 1 mm/min until the displacement of 3 mm; the load point was on first molar. The fringe distribution show more tension in the screw close to osteotomy in both groups; when SSRS was united to basilar osteotomy was produced a inferior distribution of force and in the SSRS without basilar osteotomy group was maintained a distribution into the oblique line. It's was conclude that both mandibular osteotomies was efficient in load distribution and was not observed important differences between screw related to distribution of load


Subject(s)
Humans , Bone Screws , Dental Stress Analysis/methods , Osteotomy, Sagittal Split Ramus/methods , Stress, Mechanical , Materials Testing , Internal Fixators , Elasticity , Models, Biological
3.
RGO (Porto Alegre) ; 61(supl.1): 485-489, jul.-dez. 2013.
Article in Portuguese | LILACS-Express | LILACS | ID: lil-702847

ABSTRACT

A odontogeriatria é um ramo que cada vez mais vem tomando espaço na odontologia. Este segmento vem acompanhado de uma maior conscientização, tanto de profissionais quanto de pacientes, que passam a ter maiores preocupações com a saúde bucal, chegando à terceira idade com um maior número de dentes do que as gerações anteriores. Dessa forma, o cirurgião-dentista deve estar preparado para qualquer tipo de procedimento necessário para manter os seus pacientes com uma boa qualidade de saúde bucal. A endodontia, que em décadas passadas era muito pouco realizada em pacientes idosos, tem apresentado um crescente número de casos. Baseado nesse aumento de demanda, o presente trabalho realizou uma revisão da literatura quanto aos aspectos histológicos da polpa dental senil, do tratamento endodôntico propriamente dito e de aspectos sistêmicos que podem alterar o tratamento convencional, com o intuito de orientar o profissional que se dispõe a realizar estes procedimentos na prática diária.


Geriatric dentistry is in continuous diffusion in dentistry. It is followed by professionals conscious raising and by the patients preoccupations about oral health quality, keeping into their elderly which more teeth than the past generations. In this way the professional should be prepared to do any necessary procedure to patients keep their oral health quality. The endodontics, which few decades ago were rarely done in elderly is showing a considerable arouse in number of cases. Based on that increment on endodontics procedures the present paper reviewed the literature about the histological aspects of the elderly dental pulp, the endodontic procedure itself and some systemic aspects that may interfere anyhow in comparison with the conventional treatment, to guide the professional about these procedures in the daily practice.

4.
J. appl. oral sci ; 20(5): 517-521, Sept.-Oct. 2012. ilus, graf, tab
Article in English | LILACS | ID: lil-654914

ABSTRACT

OBJECTIVE: The aim of this study was to test a new portable vibrator for plaster pouring (developed for this purpose), comparing the effect of its use on the accuracy of working cast of implant-supported restorations to the conventional vibrator. MATERIAL AND METHODS: From a master cast with 2 implants, 30 transfer moldings were made randomly and divided into three groups: Group I (GI): pouring performed in an outsourced dental laboratory with conventional plaster vibrator (10 casts), Group II (GII): pouring performed in the laboratory of the Federal University of Santa Catarina (UFSC) with conventional plaster vibrator (10 casts) and Group III (GIII): pouring performed with the portable vibrator fabricated for this study (10 casts). The position of the analogue and marginal adaptation of the infrastructure were verified by testing the single screw on the master model and on the working model. The measurement of misfit was blindly performed with a precision microscope and analyzing unit, Quadra-Check 200. The data were statistically analyzed by analysis of variance (ANOVA) and the Holm-Sidak test (α=0.05). RESULTS: Means±standard deviations were as follows: GI: 19.19±4.73 µm; GII: 21.72±5.41 µm; GIII: 13.5±2.39 µm (P<0.05), with GIII significantly lower as compared to the other groups. CONCLUSION: Within the limitations of this study, it was concluded that a greater accuracy of working cast was achieved when a portable vibrator was used for casting molds.


Subject(s)
Dental Abutments , Dental Marginal Adaptation , Models, Dental , Dental Casting Technique/instrumentation , Dental Prosthesis, Implant-Supported/instrumentation , Vibration , Calcium Sulfate , Dental Impression Materials , Dental Impression Technique , Dental Prosthesis, Implant-Supported/methods , Equipment Design , Materials Testing , Random Allocation , Reproducibility of Results , Toothbrushing/instrumentation
5.
RFO UPF ; 16(1)jan.-abr. 2011.
Article in Portuguese | LILACS | ID: lil-593678

ABSTRACT

Objetivo: Este estudo teve por objetivo avaliar a precisão de três técnicas de preenchimento do molde com gesso para obtenção de modelos de trabalho a partir de um modelo mestre simulando uma situação clínica de uma prótese fixa implanto-retida de três elementos. Materiais e métodos: Foram obtidos trinta modelos (n = 10) a partir do modelo mestre, por meio de três técnicas de preenchimento do molde com gesso. Assim, o Grupo 1 foi obtido pela técnica de preenchimento único (PU); o Grupo 2, pelo preenchimento do molde com gesso em duas porções (DP); o Grupo 3, utilizando-se a técnica do cilindro de latex (CL). Sobre a matriz metálica foi obtida uma infraestrutura fundida em titânio comer-cialmente puro simulando uma prótese fixa implanto-retida de três elementos, utilizada como referência para a avaliação de desajustes verticais em cada modelo. O desajuste vertical foi avaliado segundo a técnica do parafuso único. Para a análise dos resultados foi aplicada a análise de variância, seguida do teste de Tukey. Resultados: De acordo com os resultados obtidos, observou-se maior valor médio entre as amostras do grupo em que o molde foi preenchido com gesso pela técnica do preenchimento único (média = 0,14), ao passo que as amostras dos grupos 2 e 3 apresentaram os mesmos valores médios (média = 0,10). Porém, de acordo com o teste de Tukey, não houve diferença estatística entre os três diferentes grupos de tratamento. Conclusão: Assim, pode-se afirmar que as três técnicas foram eficientes, sendo, de acordo com a praticidade, a mais indicada a técnica de preenchimento único.

6.
RFO UPF ; 14(1): 47-50, jan.-abr. 2009. ilus, graf
Article in Portuguese | LILACS, BBO | ID: lil-516899

ABSTRACT

A indução de tensões ao implante e ao tecido ósseo peri-implantar pode ser responsável pela reabsorção tecidual e pela perda do implante. Próteses com o mínimo desajuste marginal são desejadas, acreditando-se na geração de menores valores de tensão às fixações .No entanto, não se tem certeza desta correlação, uma vez que a literatura não apresenta resultados confiáveis que venham a elucidar tal aspecto. Assim, o objetivo deste trabalho foi verificar se existe correlação entre os valores de desajuste marginal e de tensão gerados às fixações pelo parafusamento de infraestruturas implanto-retidas. Foram obtidas dez infraestruturas em titânio fundido, utilizando-se matriz metálica contendo dois implantes conectados a pilares cônicos para construções múltiplas. As infraestruturas foram aleatoriamente avaliadas quanto aos desajustes marginais mediante o teste do parafuso único e observação em microscópio ótico(120X). As tensões nas fixações foram avaliadas por extensometria. A média de desajuste marginal foi 118,07(58,61) μm e a média de tensão, 580,06 (253,93) gf.O teste de Pearson foi utilizado, mostrando não haver correlação entre desajuste marginal e tensão (-0,072),com p = 0,842. A presença e a intensidade do desajuste marginal, por si só, não são indicadores seguros no prognóstico da geração de tensões às fixações


Subject(s)
Dental Prosthesis , Dental Implants , Tensile Strength
7.
Rev. odonto ciênc ; 23(3): 268-272, jul.-set. 2008. ilus, graf, tab
Article in Portuguese | LILACS, BBO | ID: lil-494948

ABSTRACT

Objetivo: Este estudo teve por objetivo avaliar se alterações de densidade e contraste em radiografias, causadas pela degradação das soluções processadoras, podem ser visualmente identificadas. Metodologia: Foram obtidas 60 radiografias periapicais utilizado uma escala de densidades ou um phantom, processadas em uma caixa portátil com líquidos revelador e fixador em progressiva degradação ao longo de 30 dias do experimento. Os filmes da escala de densidades foram usados para avaliar a diminuição percentual de densidade e contraste, e os expostos com o phantom, para a avaliação visual. Nesta última, 18 cirurgiões-dentistas atribuíram notas às radiografias de acordo com a possibilidade de interpretação das imagens. Resultados: Constatou-se que só foram consideradas impróprias para diagnóstico as radiografias que apresentaram perdas médias de 45% de densidade e 62% de contraste. Conclusão: Concluiu-se que a avaliação clínica visual é inadequada para ser executada como um programa único de controle de qualidade de radiografias dentais.


Purpose: The objective of this study was to evaluate whether changes of density and contrast in dental radiographs caused by degradation of processing solutions can be visually identified. Methods: Sixty periapical radiographs were taken using a density scale and a phantom, and were processed in a portable dark room using processing solutions in progressive degradation over 30 days of the study. The films of the density scale were used to evaluate the percentage of density and contrast decrease, and the exposed films with the phantom were used for visual evaluation. Eighteen dentists scored the radiographs according to the possibility of image interpretation. Results: Only radiographs with 45% average loss of density and 62% of contrast were considered inappropriate for diagnostic purposes. Conclusion: It was concluded that the visual clinical evaluation is inadequate to be used as a single program of quality control in Dental Radiology.


Subject(s)
Quality Control , Radiography, Dental/standards
8.
RPG rev. pos-grad ; 15(3): 186-190, jul. -set. 2008. tab, ilus, graf
Article in Portuguese | LILACS, BBO | ID: lil-543741

ABSTRACT

Tensões ao implante e ao tecido ósseo peri-implantar podem causar reabsorção e perda de componentes. A magnitude das tensões pode variar com o uso pilares intermediários entre a prótese e os implantes. Assim, o objetivo deste trabalho foi verificar as tensões induzidas aos implantes quando submetidos ao torqueamento de infraestruturas protéicas com e sem o uso de pilar intermediário. Vinte infraestruturas em titâneo (n=10) foram obtidas por fundição a partir de matriz metálica contendo dois implantes, simulando prótese fixa de três elementos. Dez peças foram confeccionadas utilizando copings calcináveis tipo UCLA diretamente sobre os implantes. Outras dez foram confeccionadas sobre pilares cônicos intermediários para construções múltiplas. As tensões foram aferidas após o torqueamento de cada estrutura mediante o uso de extensômetros calibrados. A média de tensão no grupo UCLA foi 665,35 (173,99) gf e no grupo minipilar cônico foi 580,06 (253,93) gf. O teste t de Student foi utilizado para a comparação intergrupos. Não houve diferença estatística para os valores de tensão entre os dois grupos (p > 0,3924). O uso do pilar intermediário em infraestruturas de três elementos em Ti c.p. fundido não reduziu as tensões induzidas aos implantes.


Subject(s)
Dental Prosthesis , Dental Implants , Prosthesis Failure , Bone Screws , Dental Stress Analysis , Denture, Partial, Fixed , Tensile Strength
SELECTION OF CITATIONS
SEARCH DETAIL