Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add filters








Main subject
Language
Year range
1.
Rev. MED ; 23(2): 71-77, jul.-dic. 2015. ilus, tab
Article in Spanish | LILACS | ID: biblio-829641

ABSTRACT

Introducción: La sangre de cordón umbilical (SCU) ha sido reconocida como una fuente de células madre hematopoyéticas. Múltiples estudios han sido realizados con el propósito de determinar variables maternas y neonatales que afecten el volumen, el recuento total de células nucleadas y de células CD34+. El presente estudio correlaciona variables maternas y neonatales con el recuento total de células nucleadas y de CD34+ medidas en μL (microlitro). Materiales y Métodos: Estudio correlacional en el que se analizaron 50 muestras de sangre de cordón umbilical de gestantes atendidas en dos IPS, una de Bogotá y otra de Ubaté, (Cundinamarca), durante un período de 7 meses del año 2013. La selección de estas muestras fue basada en un muestreo no probabilístico. Se calculó el coeficiente de correlación de Pearson con su respectiva significancia estadística entre las variables cuantitativas de la madre y del neonato, y el volumen, el recuento de células CD34+ y el recuento total de células nucleadas por μL. Resultados: Se encontró correlación positiva entre la longitud del cordón y el recuento total de células nucleadas. Así mismo entre el volumen inicial de la muestra y el recuento total de células nucleadas y el recuento de células CD34+ en μL y en mL (mililitro). Discusión: Múltiples estudios se han desarrollado entorno a la búsqueda de variables maternas y neonatales que afectan la calidad de la muestra. En Colombia no se habían descrito las correlaciones encontradas en el presente estudio. Es por ello, que el desarrollo de nuevos estudios con diseños analíticos será enriquecedor.


Background: The cord blood has been recognized as a source of hematopoietic stem. Multiple studies have been conducted in order to determine maternal and neonatal variables that affect the volume, total nucleated cell count and CD34+ cells. This study correlated maternal and neonatal variables with the total nucleated cell count and CD34+ cells measured by μL. Materials and methods: Correlational study in which 50 samples of umbilical cord blood were analyzed of pregnant women at two health institutions, one at Bogotá and the other one at Ubaté, Cundinamarca, for a period of seven months of 2013. The selection of these samples was based on a non-probability sample. The Pearson correlation coefficient was calculated with their respective statistical significance between quantitative variables of mother and newborn, and the volume, the count of CD34+ cells and the total nucleated cell count measured by μL. Results: Positive correlation between the length of the umbilical cord and the total nucleated cell count was found. Similarly, correlation between total nucleated cell count with the initial volume and count of CD34+ cells in μL and mL was found. Discussion: Several studies have been conducted around to look maternal and neonatal variables that affect the sample quality, however, the Colombian literature has not described the correlation found in this study, so it requires the development of new research with designs of analytical studies to establish associations between the variables described.


Introdução: O sangue do cordão umbilical (SCU) tem sido reconhecido como uma fonte de células-tronco hematopoiéticas. Vários estudos têm sido realizados com a finalidade de determinar as variáveis maternas e neonatais que afetam o volume e a contagem total de células nucleadas e células CD34+. O presente estudo correlaciona as variáveis maternas e neonatais com a contagem total das células nucleadas e células CD34+ medidas em μL (microlitro). Materiais e métodos: Estudo correlacional no que 50 amostras de sangue do cordão umbilical de mulheres grávidas atendidas em dois IPs foram analisadas, uma em Bogota e outra em Ubaté (Cundinamarca), durante um período de 7 meses do ano 2013. A seleção destas amostras foi baseada em uma amostragem não probabilística. O coeficiente de correlação de Pearson foi calculado com a respectiva significância estatística entre variáveis quantitativas da mãe e do recém-nascido, assim como o volume, a contagem de células CD34 + e contagem total de células nucleadas por μL. Resultados: Correlação positiva foi encontrada entre o comprimento do cordão e a contagem total de células nucleadas. Também entre o volume da amostra inicial e contagem total de células nucleadas e contagem de células CD34+ em μL e em mL (mililitro). Discussão: Vários estudos têm sido desenvolvidos em torno da busca de variáveis maternas e neonatais que afetam a qualidade da amostra. Na Colômbia não tinham sido descritas as correlações encontradas no presente estudo. É por esta razão que será gratificante o desenvolvimento de novos estudos com desenhos analíticos.


Subject(s)
Humans , Pregnancy , Stem Cells , Risk Factors , Colombia , Antigens, CD34 , Fetal Blood
SELECTION OF CITATIONS
SEARCH DETAIL