Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Braz. j. phys. ther. (Impr.) ; 17(3): 227-235, jun. 2013. tab, graf
Article in English | LILACS | ID: lil-680657

ABSTRACT

BACKGROUND: the assessment of functional capacity in patients with chronic obstructive pulmonary disease (COPD) has been performed by simple and easy to apply methods that mimic everyday activities, such as the Chester step test (TChester). OBJECTIVES: to investigate whether TChester is able to differentiate functional capacity and the magnitude of cardiorespiratory response of patients with COPD from healthy subjects; and to compare it with the cardiorespiratory response induced by shuttle test (TShuttle) and six-minute walk test (6MWT). METHOD: 10 patients with COPD (64±10 years, and forced expiratory volume at the first second - FEV1 38.1±11.8% predicted) and 10 healthy subjects (63±7 years, and FEV1 of 95.8±18.0% predicted) underwent evaluation of pulmonary function, functional status and capacity (6MWT, TShuttle and TChester). RESULTS: COPD patients had worst performance in all tests, when compared to healthy subjects (TChester 2,1±0,9 vs. 4,1±1,1 completed levels; TC6min: 435±105,1 vs. 593±87,3 m; TShuttle 251±84,6 vs. 436±55,4 m; p<0.05). TChester correlated with TShuttle and 6MWT (r =0.67 and 0.83, respectively, p<0.05). There were no differences in heart rate and dyspnea in TChester levels between groups (p>0.05). SpO2 was lower in COPD patients since the first TChester level (p<0.05). CONCLUSION: TChester is valid in the assessment of functional capacity of COPD patients, being able to distinguish them from healthy subjects, inducing similar cardiovascular demand and greater desaturation in COPD patients. .


CONTEXTUALIZAÇÃO: A avaliação da capacidade funcional em pacientes com doença pulmonar obstrutiva crônica (DPOC) tem sido realizada por métodos simples, de fácil aplicação e que mimetizam as atividades cotidianas, como o teste step Chester (TChester). OBJETIVOS: Investigar se o TChester é capaz de diferenciar a capacidade funcional e a magnitude da resposta cardiorrespiratória de pacientes com DPOC e de indivíduos saudáveis e comparar com a resposta cardiorrespiratória induzida pelos testes de caminhada de seis minutos (TC6min) e Shuttle (TShuttle). MÉTODO: Participaram dez pacientes com DPOC (64±10 anos, volume expiratório forçado no primeiro segundo - VEF1 de 38,1±11,8% do predito) e dez saudáveis (63±7 anos, IMC de 24,5±3,1 e VEF1 de 95,8±18,0% do predito) que realizaram avaliação da função pulmonar, estado e capacidade funcional. RESULTADOS: O grupo DPOC obteve pior desempenho nos três testes, quando comparado ao controle (TChester 2,1±0,9 vs 4,1±1,1 níveis completos; TC6min: 435±105,1 vs 593±87,3 m; TShuttle 251±84,6 vs 436±55,4 m; p<0,05). O TChester correlacionou-se com o TShuttle e com o TC6min (r=0,67 e 0,83, respectivamente; p<0,05). Não se observaram diferenças na frequência cardíaca (FC) e dispneia nos níveis do TChester entre os grupos (p>0,05). A SpO2 apresentou-se mais reduzida no grupo DPOC já no primeiro nível do TChester (p<0,05). CONCLUSÃO: O TChester é válido na avaliação da capacidade funcional de pacientes com DPOC, sendo capaz de diferenciá-los de indivíduos saudáveis, induzindo similar demanda cardiovascular e maior dessaturação nos pacientes ...


Subject(s)
Female , Humans , Male , Middle Aged , Exercise Tolerance , Exercise Test/methods , Heart/physiopathology , Pulmonary Disease, Chronic Obstructive/physiopathology , Respiration
2.
Braz. j. phys. ther. (Impr.) ; 15(6): 467-473, Nov.-Dec. 2011.
Article in English | LILACS | ID: lil-611338

ABSTRACT

BACKGROUND: The Glittre ADL (TGlittre) test is a specifically designed to assess functional limitation in chronic obstructive pulmonary disease (COPD) patients. However, it is not known if it can differentiate the performance of these patients from healthy subjects. OBJECTIVES: To investigate whether the Glittre ADL test is able to differentiate the functional capacity of COPD patients from that of healthy subjects and to compare the cardiorespiratory response between Glittre ADL and the six-minute walk test (6MWT). METHODS: The study included 10 patients with COPD (GOLD 2 to 4) and 10 healthy subjects matched by age who performed the following: spirometry pre-and post-bronchodilator, a Glittre ADL test and two 6MWT on two consecutive days. RESULTS: The performance of COPD (FEV1 percentpred= 38.1±11.8, age=64±10 years, BMI=23.7±5.2 kg/ m²) was worse than the control group on TGlittre (5.26±2.9 min, 3.3±0.3 min, p<0.05) and 6MWT (434.97±105.18 m vs. 593.25±87.36 m, p<0.05). TGlittre correlated with the physical activity domain of the London Chest Activity of Daily Living (LCADL) scale (r=0.67, p<0.05) and with 6MWT when the total sample was analyzed (r=-0.64, p<0.05). The COPD group had a statistically higher (p<0.05) increase in dyspnea (Borg scale) than the control group for both TGlittre and 6MWT, with a similar heart rate and peripheral oxygen saturation variation in both groups (p>0.05). CONCLUSIONS: The performance of COPD patients is worse than that of healthy subjects on the Glittre ADL test, with a greater increase in dyspnea and similar heart rates.


CONTEXTUALIZAÇÃO: O teste de AVD Glittre (TGlittre) é um teste específico desenvolvido para avaliar a limitação funcional em pacientes com doença pulmonar obstrutiva crônica (DPOC), no entanto não se sabe qual sua capacidade de diferenciar o desempenho de doentes do de indivíduos saudáveis. OBJETIVOS: Investigar se o TGlittre é capaz de diferenciar a capacidade funcional de pacientes com DPOC da de indivíduos normais, além de comparar a resposta cardiorrespiratória induzida pelo TGlittre com a do teste de caminhada de seis minutos (TC6min). MÉTODOS: Participaram do estudo dez indivíduos com DPOC (GOLD 2 a 4) e dez indivíduos saudáveis de mesma faixa etária, realizando as seguintes avaliações: espirometria pré e pós-broncodilatador; um TGlittre e dois TC6min em dois dias consecutivos. RESULTADOS: O grupo DPOC (VEF1 por centoprev = 38,1±11,8, idade = 64±10 anos) apresentou pior desempenho que o grupo controle no TGlittre (5,26±2,9 min vs. 3,3±0,3 min, p<0,05) e no TC6min (434,97±105,18 m vs. 593,25±87,36 m, p<0,05). O TGlittre correlacionou-se com o domínio atividade física da escala London Chest Activity of Daily Living (LCADL) (r=0,67, p<0,05) no grupo DPOC e com o TC6min na amostra total (r=-0,64; p<0,05). Tanto no TGlittre como no TC6min, o grupo DPOC registrou aumento da dispneia (Borg) estatisticamente maior (p<0,05) que no grupo controle, com frequência cardíaca e saturação periférica de oxigênio similares (p>0,05). CONCLUSÕES: Pacientes com DPOC têm pior desempenho que indivíduos saudáveis no TGlittre, com maior dispneia e frequência cardíaca similar.


Subject(s)
Female , Humans , Male , Middle Aged , Activities of Daily Living , Exercise Test/methods , Pulmonary Disease, Chronic Obstructive/physiopathology , Cross-Sectional Studies , Diagnosis, Differential , Pulmonary Disease, Chronic Obstructive/diagnosis
SELECTION OF CITATIONS
SEARCH DETAIL