ABSTRACT
Abstract Background: Posterior subcapsular cataract is a tissue reaction commonly found among professionals exposed to ionizing radiation. Objective: To assess the prevalence of cataract in professionals working in hemodynamics in Brazil. Methods: Professionals exposed to ionizing radiation (group 1, G1) underwent slit lamp examination with a biomicroscope for lens examination and compared with non-exposed subjects (group 2, G2). Ophthalmologic findings were described and classified by opacity degree and localization using the Lens Opacities Classification System III. Both groups answered a questionnaire on work and health conditions to investigate the presence of risk factors for cataract. The level of significance was set at 5% (p < 0.05). Results: A total of 112 volunteers of G1, mean age of 44.95 (±10.23) years, and 88 volunteers of G2, mean age of 48.07 (±12.18) years were evaluated; 75.2% of G1 and 85.2% of G2 were physicians. Statistical analysis between G1 and G2 showed a prevalence of posterior subcapsular cataract of 13% and 2% in G1 and G2, respectively (0.0081). Considering physicians only, 38% of G1 and 15% of G2 had cataract, with the prevalence of posterior subcapsular cataract of 13% and 3%, respectively (p = 0.0176). Among non-physicians, no difference was found in the prevalence of cataract (by types). Conclusions: Cataract was more prevalent in professionals exposed to ionizing radiation, with posterior subcapsular cataract the most frequent finding.
Resumo Fundamento: A catarata subcapsular posterior é uma reação tecidual encontrada com frequência nos profissionais expostos à radiação ionizante. Objetivo: Avaliar a prevalência de catarata nos profissionais que atuam na área de hemodinâmica no Brasil. Métodos: Profissionais expostos à radiação ionizante (grupo 1, G1) foram submetidos ao exame biomicroscópico com lâmpada de fenda para avaliação do cristalino, e comparados aos não expostos (grupo 2, G2). Os achados foram descritos e classificados quanto ao grau de opacidade e localização por meio do Lens opacities classification system III. Ambos os grupos responderam questionário sobre condições de trabalho e de saúde para afastar fatores de risco para catarata, e foram comparados quanto aos achados. Foi utilizado um nível de significância de 5% (p < 0,05). Resultados: Foram avaliados 112 voluntários (G1) com média de idade 44,95 (±10,23) anos e 88 voluntários (G2) com média de 48,07 (±12,18) anos. Desses, 75,2% (G1) e 85,2% (G2) eram médicos. A análise estatística entre os grupos G1 e G2 mostrou uma prevalência da catarata no grupo G1 de 33% comparada ao G2 de 16% (p = 0,0058), sendo a catarata subcapsular posterior presente em 13% no G1 e 2% no G2 (p = 0,0081). Considerando apenas os médicos, 38% no G1 e 15% no G2 (p = 0,0011) apresentaram catarata, sendo a subcapsular posterior 13% e 3% (p = 0,0176), respectivamente. No grupo dos profissionais não médicos, não houve diferença estatisticamente significativa na prevalência dos achados oftalmológicos. Conclusões: A catarata esteve mais presente no grupo de profissionais expostos à radiação ionizante, sendo que a catarata subcapsular posterior foi o dano tecidual mais encontrado.
Subject(s)
Humans , Male , Female , Adult , Middle Aged , Aged , Cataract/epidemiology , Radiation Exposure/adverse effects , Cardiologists/statistics & numerical data , Lens, Crystalline/radiation effects , Occupational Diseases/epidemiology , Radiation, Ionizing , Cataract/etiology , Brazil/epidemiology , Prevalence , Risk Factors , Occupational Exposure/adverse effects , Statistics, Nonparametric , Radiation Exposure/statistics & numerical data , Eye Protective Devices/statistics & numerical data , Hemodynamics , Occupational Diseases/etiologyABSTRACT
Abstract Objective: To study the influence that the scan percentage tool used in partial k-space acquisition has on the quality of images obtained with magnetic resonance imaging equipment. Materials and Methods: A Philips 1.5 T magnetic resonance imaging scanner was used in order to obtain phantom images for quality control tests and images of the knee of an adult male. Results: There were no significant variations in the uniformity and signal-to-noise ratios with the phantom images. However, analysis of the high-contrast spatial resolution revealed significant degradation when scan percentages of 70% and 85% were used in the acquisition of T1- and T2-weighted images, respectively. There was significant degradation when a scan percentage of 25% was used in T1- and T2-weighted in vivo images (p ≤ 0.01 for both). Conclusion: The use of tools that limit the k-space is not recommended without knowledge of their effect on image quality.
Resumo Objetivo: Estudar a influência da ferramenta scan percentage, usada para a aquisição parcial do espaço K na qualidade de imagens obtidas por ressonância magnética. Materiais e Métodos: Foi usado um equipamento de ressonância magnética Philips de 1,5 T para obter imagens de um objeto simulador e imagens in vivo do joelho de um adulto do sexo masculino. Resultados: Com o objeto simulador, não ocorreram variações significativas quanto à avaliação da uniformidade e razão sinal-ruído. Entretanto, na análise da resolução espacial de alto contraste, houve significativa degradação nas imagens quando adotada a scan percentage a 70% e 85% em T1 e T2, respectivamente. Nas imagens in vivo comprovou-se a degradação somente quando adotada a scan percentage a 25% (p ≤ 0,01) em T1 e T2. Conclusão: Não é aconselhável adotar ferramentas que limitem o espaço K sem que haja conhecimento sobre sua influência na qualidade da imagem clinicamente gerada.
ABSTRACT
AbstractObjective:To assess the reduction of estimated radiation dose in abdominal computed tomography following the implementation of new scan protocols on the basis of clinical suspicion and of adjusted images acquisition parameters.Materials and Methods:Retrospective and prospective review of reports on radiation dose from abdominal CT scans performed three months before (group A – 551 studies) and three months after (group B – 788 studies) implementation of new scan protocols proposed as a function of clinical indications. Also, the images acquisition parameters were adjusted to reduce the radiation dose at each scan phase. The groups were compared for mean number of acquisition phases, mean CTDIvol per phase, mean DLP per phase, and mean DLP per scan.Results:A significant reduction was observed for group B as regards all the analyzed aspects, as follows: 33.9%, 25.0%, 27.0% and 52.5%, respectively for number of acquisition phases, CTDIvol per phase, DLP per phase and DLP per scan (p < 0.001).Conclusion:The rational use of abdominal computed tomography scan phases based on the clinical suspicion in conjunction with the adjusted images acquisition parameters allows for a 50% reduction in the radiation dose from abdominal computed tomography scans.
ResumoObjetivo:Quantificar a redução da dose estimada de radiação em exames de tomografia computadorizada de abdome após a implementação de novos protocolos dirigidos para a suspeita clínica e ajuste nos parâmetros técnicos de aquisição.Materiais e Métodos:Foram avaliados, de forma retrospectiva e prospectiva, os relatórios de dose de exames de tomografia computadorizada de abdome realizados três meses antes (grupo A – 511 exames) e três meses após (grupo B – 788 exames) a implementação de novos protocolos de exame propostos em função das indicações clínicas. Contemporaneamente, os parâmetros de aquisição das imagens foram ajustados de modo a reduzir a exposição em cada fase do exame. Os grupos foram comparados quanto ao número médio de fases de aquisição, valores de CTDIvol por fase, DLP por fase e DLP por exame.Resultados:O grupo B apresentou redução significativa em todos os aspectos analisados: número de fases, CTDIvol por fase, DLP por fase e DLP por exame mostraram reduções de 33,9%, 25,0%, 27,0% e 52,5%, respectivamente (p < 0,001).Conclusão:O uso racional das fases de aquisição dirigidas para a suspeita clínica, em conjunto com adequação nos aspectos técnicos, permite reduzir pela metade a dose de radiação por exame de tomografia computadorizada de abdome.
ABSTRACT
Objective: To evaluate the necessity of the non contrast-enhanced phase in abdominal computed tomography scans. Materials and Methods: A retrospective, cross-sectional, observational study was developed, evaluating 244 consecutive abdominal computed tomography scans both with and without contrast injection. Initially, the contrast-enhanced images were analyzed (first analysis). Subsequently, the observers had access to the non-contrast-enhanced images for a second analysis. The primary and secondary diagnoses were established as a function of the clinical indications for each study (such as tumor staging, acute abdomen, investigation for abdominal collection and hepatocellular carcinoma, among others). Finally, the changes in the diagnoses resulting from the addition of the non-contrast-enhanced phase were evaluated. Results: Only one (0.4%; p > 0.999; non-statistically significant) out of the 244 reviewed cases had the diagnosis changed after the reading of non-contrast-enhanced images. As the secondary diagnoses are considered, 35 (14%) cases presented changes after the second analysis, as follows: nephrolithiasis (10%), steatosis (3%), adrenal nodule (0.7%) and cholelithiasis (0.3%). Conclusion: For the clinical indications of tumor staging, acute abdomen, investigation of abdominal collections and hepatocellular carcinoma, the non-contrast-enhanced phase can be excluded from abdominal computed tomography studies with no significant impact on the diagnosis. .
Objetivo: Avaliar a necessidade da fase sem contraste nos exames de tomografia computadorizada de abdome. Materiais e Métodos: Foi realizado estudo retrospectivo, transversal e observacional, no qual foram avaliados 244 exames consecutivos de tomografia computadorizada de abdome realizados sem e com a injeção do meio de contraste. Procurou-se estabelecer, mediante análise das fases com o uso do meio de contraste (primeira análise), e posteriormente com o acréscimo da avaliação da fase sem meio de contraste (segunda análise), o diagnóstico principal e os secundários em função da indicação clínica do exame (estadiamento tumoral, abdome agudo, pesquisa de coleção abdominal e hepatocarcinoma, entre outros). Foram medidas as mudanças nos diagnósticos principais e secundários, decorrentes do acréscimo da fase sem meio de contraste. Resultados: Dos 244 casos avaliados, apenas um (0,4%; p > 0,999; não significante) teve o seu diagnóstico modificado após a leitura da fase sem meio de contraste. Com relação aos diagnósticos secundários, 35 exames (14%) foram modificados após a segunda análise, sendo: nefrolitíase (10%), esteatose (3%), nódulo de adrenal (0,7%) e colelitíase (0,3%). Conclusão: Para as indicações clínicas de estadiamento tumoral, abdome agudo, pesquisa de coleção abdominal e carcinoma hepatocelular, a supressão da fase sem meio de contraste não apresentou impacto diagnóstico expressivo. .
ABSTRACT
Objective To develop procedures to ensure consistency of printing quality of digital images, by means of hardcopy quantitative analysis based on a standard image. Materials and Methods Characteristics of mammography DI-ML and general purpose DI-HL films were studied through the QC-Test utilizing different processing techniques in a FujiFilm®-DryPix4000 printer. A software was developed for sensitometric evaluation, generating a digital image including a gray scale and a bar pattern to evaluate contrast and spatial resolution. Results Mammography films showed maximum optical density of 4.11 and general purpose films, 3.22. The digital image was developed with a 33-step wedge scale and a high-contrast bar pattern (1 to 30 lp/cm) for spatial resolution evaluation. Conclusion Mammographic films presented higher values for maximum optical density and contrast resolution as compared with general purpose films. The utilized digital processing technique could only change the image pixels matrix values and did not affect the printing standard. The proposed digital image standard allows greater control of the relationship between pixels values and optical density obtained in the analysis of films quality and printing systems. .
Objetivo Desenvolver procedimentos que garantam a constância e qualidade de impressão das imagens digitais, mediante análise quantitativa das imagens impressas utilizando um padrão de imagem. Materiais e Métodos Foram estudadas as características dos filmes mamográficos (DI-ML) e de uso geral (DI-HL) por meio do teste QC-Test sob diferentes processamentos utilizando a impressora FujiFilm®-DryPix4000. Foi criado um software para avaliação sensitométrica que gera uma imagem digital contendo uma escala de níveis de cinza e um padrão de barras para avaliação das resoluções de contraste e espacial. Resultados Filmes mamográficos apresentaram valores de densidade óptica máxima 4,11, enquanto os comuns apresentaram valores 3,22. A imagem digital foi desenvolvida com 33 passos de enegrecimento e um padrão de barras de alto contraste (1 a 30 pl/cm) para avaliação da resolução espacial. Conclusão Verificou-se que o filme mamográfico apresenta um maior valor de densidade máxima e maior índice de contraste, comparado ao filme de uso geral. O processamento digital utilizado apenas alterou os valores da matriz de pixels da imagem e não influenciou o padrão de impressão. O padrão de imagem digital proposto permite maior controle da relação entre os valores de pixel e densidade ótica obtida na verificação da qualidade dos filmes e do sistema de impressão. .
ABSTRACT
OBJETIVO: Avaliar o impacto sobre o treinamento de residentes utilizando uma ferramenta computacional dedicada à avaliação do desempenho da leitura de imagens radiológicas convencionais e digitais. MATERIAIS E MÉTODOS: O treinamento foi realizado no Laboratório de Qualificação de Imagens Médicas (QualIM). Os residentes de radiologia efetuaram cerca de 1.000 leituras de um total de 60 imagens obtidas de um simulador estatístico (Alvim®) que apresenta fibras e microcalcificações de dimensões variadas. O desempenhodos residentes na detecção dessas estruturas foi avaliado por meio de parâmetros estatísticos. RESULTADOS:Os resultados da probabilidade de detectabilidade foram de 0,789 e 0,818 para os sistemas convencional e digital, respectivamente. As taxas de falso-positivos foram de 8% e 6% e os valores de verdadeiro- -positivos, de 66% e 70%, respectivamente. O valor de kappa total foi 0,553 para as leituras em negatoscópio e 0,615 em monitor. A área sob a curva ROC foi de 0,716 para leitura em filme e 0,810 para monitor.CONCLUSÃO: O treinamento proposto mostrou ser efetivo e apresentou impacto positivo sobre o desempenhodos residentes, constituindo-se em interessante ferramenta pedagógica. Os resultados sugerem que o método de treinamento baseado na leitura de simuladores pode produzir um melhor desempenho dos profissionais na interpretação das imagens mamográficas.
OBJECTIVE: The present study was aimed at evaluating the performance of residents trained in the reading of conventional and digital mammography images with a specific computational tool. MATERIALS AND METHODS: The training was accomplished in the Laboratory of Medical Images Qualification (QualIM û Laboratório de Qualificação de Imagens Médicas). Residents in radiology performed approximately 1,000 readings of a set of 60 images acquired from a statistical phantom (Alvim®) presenting microcalcifications and fibers with different sizes. The analysis of the residents' performance in the detection of these structures was based on statistical parameters. RESULTS: Values for detection probability were respectively 0.789 and 0.818 for conventional and digital systems. False-positive rates were 8% and 6%, and true-positive rates, 66% and 70% respectively. The total kappa value was 0.553 for readings on the negatoscope (hard-copy readings), and 0.615 on the monitor (soft-copy readings). The area under the ROC curve was 0.716 forhard-copy readings and 0.810 for soft-copy readings. CONCLUSION: The training has showed to be effective,with a positive impact on the residents' performance, representing an interesting educational tool. The resultsof the present study suggest that this method of training based on the reading of images from phantoms can improve the practitioners' performance in the interpretation of mammographic images.
Subject(s)
Humans , Computer-Assisted Instruction , Diagnosis, Computer-Assisted/methods , Mammography/methods , Radiographic Image Interpretation, Computer-Assisted , Software , Teaching Materials , Radiography/methodsABSTRACT
OBJETIVO: Foi desenvolvido um software denominado QualIM® - Qualificação de Imagens Médicas para treinamento de profissionais na interpretação de exames digitais de mamografias utilizando ferramentas de manipulação de imagens, em monitores específicos, classificadas em BI-RADS®. MATERIAIS E MÉTODOS: O sistema, desenvolvido em Delphi 7, armazena as respostas da interpretação de imagens mamográficas durante o treinamento e compara aos dados inseridos denominados "padrão-ouro". O sistema contém imagens de computed radiography, direct radiography e digitalizadas. O software converte as imagens do computed radiography e direct radiography para o formato TIFF, mantendo as resoluções espacial e de contraste originais. Profissionais em treinamento manipulam o realce da imagem utilizando ferramentas de software (zoom, inversão, réguas digitais, outras). Dependendo da complexidade, são apresentadas até oito incidências mamográficas, seis imagens de ultra-som e duas de anatomopatológico. RESULTADOS: O treinamento iniciou em 2007 e atualmente faz parte do programa de residência em radiologia. O software compõe o texto, de forma automática, das informações inseridas pelo profissional, baseado nas categorias BI-RADS, e compara com a base de dados. CONCLUSÃO: O software QualIM é uma ferramenta digital de ensino que auxilia profissionais no reconhecimento de padrões visuais de uma imagem mamográfica, bem como na interpretação de exames mamográficos, utilizando a classificação BI-RADS.
OBJECTIVE: A software called QualIM® - Qualificação de Imagens Médicas was developed for training of practitioners in the interpretation of digital mammograms classified according to BI-RADS® categories, utilizing images manipulation tools on state-of-the-art displays. MATERIALS ANDMETHODS: A Delphi 7-based system stores data resulting from mammographic findings interpretation during the training, comparing them with a golden-standard data set. The database includes computed radiography, direct radiography and digitized images. The software converts computed radiography and direct radiography images into TIFF format, preserving their original spatial and contrast resolution. During the training, the images are manipulated with the aid of the software tools (zoom, inversion, digital rulers and others). Depending on the image complexity, up to eight mammographic views, six ultrasonography images and two anatomopathological images can be displayed. RESULTS: The training was initiated in 2007 and is currently included in the radiology residency program. Based on data entered by the practitioner, the software automatically generates a BI-RADS compliant text that is compared with a database. CONCLUSION: The QualIM software is a digital educational tool aimed at assisting practitioners in the recognition of visual patterns on mammographic images as well as in the interpretation of mammograms based on the BI-RADS classification.
Subject(s)
Humans , Diagnostic Imaging , Education , Image Interpretation, Computer-Assisted , Mammography/instrumentation , Decision Making, Computer-Assisted , Teaching MaterialsSubject(s)
Humans , Early Detection of Cancer , Mammography , Mentoring , Quality Control , Sensitivity and SpecificityABSTRACT
Gestantes podem precisar ser submetidas a exames radiológicos para um diagnóstico preciso e conduta correta. Nestes casos a exposição à radiação ionizante e seus efeitos sobre o feto são motivo de preocupação para a paciente e o seu médico. Na verdade, a maioria destes exames é segura e não oferece risco significativo ao feto. No entanto, é importante que o radiologista conheça estes riscos potenciais para poder orientar adequadamente todos os envolvidos no atendimento.
X-ray examinations may be necessary during pregnancy for an accurate diagnosis and adequate treatment administration. In these cases, the exposure to ionizing radiation and its effects on the fetus are a major concern to the patient and to the clinician. In fact, most of these examinations are safe and do not represent a significant risk to the fetus. However, the radiologist must know the potential risks to be able to instruct all personnel involved in the care of the patient.
Subject(s)
Humans , Female , Pregnancy , Pregnancy/radiation effects , Radiation , Radiation Exposure , Diagnostic Imaging/adverse effects , Radiation Dosage , Radiation, Ionizing , Radiation Tolerance/radiation effectsABSTRACT
OBJETIVO: Avaliar a precisão das doses de radiação absorvidas na terapia de transplantes de medula óssea durante a técnica de irradiação de corpo inteiro. MATERIAIS E MÉTODOS: Utilizaram-se 200 pastilhas de sulfato de cálcio com disprósio compactado com teflon (CaSO4 + teflon), calibradas no ar e no "phantom", selecionadas aleatoriamente e dispostas em grupos de cinco no corpo dos pacientes. As leituras dosimétricas foram efetuadas pela leitora Harshaw 4000A. Nove pacientes foram irradiados no corpo inteiro em paralelos e em opostos laterais, utilizando-se unidade de cobalto-60, modelo Alcion II, com taxa de dose de 0,80 Gy/min a 80,5 cm, {campo (10 × 10) cm²}. A dosimetria dessa unidade foi realizada com dosímetro Victoreen 500. Para a determinação da dose média em cada ponto avaliado usaram-se os fatores individuais de calibração das pastilhas no ar e no "phantom", colocando-se um "build up" de 2 mm para superficializar a dose à distância de 300 cm. RESULTADOS: Em 70 por cento dos pacientes obteve-se variação de dose menor que 5 por cento e em 30 por cento dos pacientes essa variação foi inferior a 10 por cento, quando comparados os valores medidos com aqueles calculados em cada ponto. Na cabeça ocorre absorção, em média, de 14 por cento da dose administrada, e nos pulmões, acréscimo de 2 por cento na dose administrada. Nos pacientes com distância látero-lateral maior que 35 cm as variações entre as doses calculadas e medidas podem chegar a 30 por cento da dose desejada, sem o uso de filtros compensadores. CONCLUSÃO: Os valores medidos das doses absorvidas nos diversos pontos anatômicos, comparados aos valores desejados (teóricos), apresentam tolerância de ±10 por cento, considerando-se as diferenças anatômicas existentes, quando utilizados os fatores de calibração individuais das pastilhas.
Subject(s)
Humans , Male , Female , Bone Marrow Transplantation , Thermoluminescent Dosimetry/adverse effects , Radiation Dosimeters/analysis , Leukemia/radiotherapy , Thermoluminescent Dosimetry , Whole-Body IrradiationABSTRACT
OBJETIVO: Disponibilizar aos profissionais da radiologia um "software" para treinamento na interpretação de imagens mamográficas em sistemas digitais. MATERIAIS E MÉTODOS: Foi desenvolvido um "software" em Delphi associado a uma base de dados em Interbase, com a finalidade de armazenar imagens de exames mamográficos associados aos seus laudos em categorias BI-RADS®. As imagens foram previamente qualificadas e digitalizadas em "scanner" a laser Lumiscan 75. O treinamento se faz com imagens apresentadas em monitores comerciais de 17 polegadas, no tamanho 18 Î 24 cm. O "software" permite visualizar cada projeção das mamas individualmente, médio-lateral oblíqua e crânio-caudal, ou as quatro imagens simultaneamente. Permite acessar as imagens e os laudos existentes ou interpretar as imagens utilizando o sistema de categorias BI-RADS®, em que o "software" compara o laudo do usuário com as informações do banco de dados, apontando acertos e erros da interpretação. RESULTADOS: O usuário adquire familiaridade com sistemas digitais, laudos em categorias BI-RADS® e aspectos de qualidade do processo gerador das imagens relativo à detecção de fibras e microcalcificações. CONCLUSÃO: O "software" disponível na intranet da Universidade Federal de São Paulo é ferramenta valiosa para os profissionais interessados em sistemas digitais.
OBJECTIVE: To make a software available for training professionals in the interpretation of mammography images on digital systems. MATERIALS AND METHODS: The software was developed in Delphi and linked to a Interbase database to store mammographic images in association with the BI-RADS® category results. Images were previously qualified and digitized using a Lumiscan 75 laser scanner. Training is done on 18 × 24 cm images displayed on a 172 commercial monitor. The software allows displaying of each breast view individually, medial-lateral oblique and cranial-caudal views, or four images simultaneously. The user selects an exam from the database and makes a diagnosis classifying the image into BI-RADS® categories. At the end of the process, the software compares the user's interpretation with the data stored in the database and than yields scores. RESULTS: The user becomes familiar with digital systems, images interpretation using BI-RADS® categories and with the quality of the image generating process regarding the detection of fibers and microcalcifications. CONCLUSION: The software is available at "Universidade Federal de São Paulo", São Paulo, Brazil, intranet and is a valuable tool for training professionals interested in digital systems.
Subject(s)
Diagnostic Imaging/classification , Mammography , Radiographic Image Interpretation, Computer-Assisted , Software , Information Systems , Quality Control , Radiographic Image Interpretation, Computer-AssistedABSTRACT
Considerando a natureza sutil dos achados mamográficos, é importante conhecermos como a detectabilidade de pequenos objetos, como fibras e microcalcificações, normalmente presentes em imagens mamográficas, pode ser influenciada pela intensidade luminosa do negatoscópio utilizado nas leituras. Nosso objetivo foi verificar como a luminância pode alterar a detectabilidade de objetos simulados. Foram feitas sete imagens com diferentes intensidades de exposição em duas condições técnicas usando um simulador que permite avaliações estatísticas. Os resultados foram computados usando uma escala de cinco níveis de confiança (100 se o especialista tem certeza da presença do objeto; 75 se provável a presença do objeto; 50 se incerta; 25 se improvável; zero se definitivamente ausente). As imagens foram interpretadas por especialistas que utilizaram negatoscópios "padrões" e específicos para imagens mamográficas. As detectabilidades foram estatisticamente comparadas entre si para cada tipo de negatoscópio por meio do teste do qui-quadrado de Pearson (p < 0,05). A detectabilidade variou de 0,79 a 0,87. Pudemos concluir que a detectabilidade dos objetos, determinada por meio de objetos simulados, é superior para os negatoscópios específicos para mamografias quando comparada aos negatoscópios "padrões" amplamente utilizados na radiologia geral
Considering the subtle findings observed in mammography images, it is relevant to know how detectability of fibers and microcalcifications can be influenced by the luminance of the viewing boxes. Our goal was to determine the influence of the luminance on the detectability of tiny simulated objects. We obtained seven images with different exposure levels using a phantom that allows statistical analysis. The results were computed using a five point scale to report the confidence levels (100 if the evaluator was sure that the object is present; 75 if likely; 50 if uncertain; 25 if not likely; zero if definitely absent). The images were analyzed by specialists using a "standard" and a specific viewing box for mammography. The detectability was compared using the Pearson chi-square test (p < 0.05). The values varied from 0.79 to 0.87. We concluded that the detectability determined from simulated objects through readings on the specific viewing boxes is higher when compared with the readings using standard viewing boxes.
Subject(s)
Mammography/instrumentation , Mammography/standards , Technology, Radiologic , Contrast Sensitivity , Diagnostic Imaging , Quality Control , Sensitivity and SpecificityABSTRACT
Resumo: Foram determinadas as doses absorvidas na pele de pacientes submetidos a exames de urografia excretora, utilizando-se dosímetros termoluminescentes de CaSO4: Dy. Os valores de dose foram associados aos dados obtidos no programa de controle de qualidade dos equipamentos radiológicos e, dessa forma, foi proposta uma equaçäo para a dose absorvida em funçäo da fraçäo de dose relativa ao rendimento do feixe de raios X (mC/Kg.mAs). Esta equaçäo permite o cálculo da dose em exames de urografia excretora em qualquercentro radiológico que possua um programa de controle de qualidade dos equipos capaz de identificar como comparáveis as condiçöes tecnológicas empregadas às utilizadas neste estudo
Subject(s)
Humans , Radiation Control , Radiometry , Radiometry/adverse effects , Urography/radiation effectsABSTRACT
O estudo sensitométrico de filmes radiológicos permite extrair informaçöes importantes sobre suas características intrínsecas responsáveis pelo seu desempenho. Sabe-se que a resposta sensitométrica desejada pode ser obtida ajustando-se as condiçöes de processamento. Este estudo pretende identificar as condiçöes de processamento nas quais pode-se obter respostas semelhantes de três tipos de filmes radiológicos dos fabricantes DuPont, IBF, Kodak e Fuji, utilizados em exames de mamografia, radiologia convencional e tomografia computadorizada, medicina nuclear e ultra-som. Os filmes foram sensibilizados e relevados na processadora M7A-Kodak, variando-se a temperatura a cada 0, 5ºC para o intervalo entre 30, 0ºC e 38, 5ºC.Foram utilizados os químicos IBF e Kodak. Os parâmetros extraídos das curvas sensitométricas foram: gradiente médio, velocidade relativa, base + véu e densidade máxima. A análise estatística foi aplicada, para comparar a influência da temperatura, químicos e filmes, para cada um dos parâmetros. A análise de variância mostrou interaçöes significantes entre filmes , temperaturas e químicos.
Subject(s)
Evaluation Study , Image Processing, Computer-Assisted , /instrumentationSubject(s)
Humans , History, 19th Century , History, 20th Century , Radiation Protection , Radiography/history , X-RaysABSTRACT
Avaliamos as doses de radiação absorvidas na pele, utilizando a dosimetria termoluminescente, em pacientes submetidos a exames radiológicos de torax, seios da face e coluna lombar, em condições técnico-operacionais variadas. Os resultados mostraram diferenças relevantes na dose absorvida para as alternativas técnicas estudadas.
Subject(s)
Humans , Process Optimization , Thermoluminescent Dosimetry , Radiation Dosage , Radiation ProtectionABSTRACT
Avaliamos a dose absorvida na pele de pacientes submetidos a exames radiológicos de tórax, seios da face e coluna lombar, através da dosimetria termoluminescente, em condições técnico-operacionais variadas. Os resultados mostraram diferenças relevantes na dose absorvida para as alternativas técnicas empregadas.
Subject(s)
Humans , Skin/radiation effects , Spine/radiation effects , Thermoluminescent Dosimetry , Face/radiation effects , Radiation Dosage , Thorax/radiation effectsABSTRACT
Este trabalho caracteriza dosímetros termoluminescentes de CaSO(4): Dy de diferentes espessuras (0,2 a 0,8mm) e com diferentes porcentagens de grafite (0; 0,5; 3; 5; 10 e 20 por cento em massa), indicados como alternativos para a avaliação de dose absorvida em campos mistos (fótons e beta). Previamente foram apresentados os resultados relacionados às aplicações na dosimetria beta; neste trabalho são estudados sensibilidade e dependência energética dos mesmos resultados obtidos nas avaliações destes dosímetros para fótons.