Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
Arq. bras. oftalmol ; 76(3): 152-154, maio-jun. 2013. ilus
Article in English | LILACS | ID: lil-681846

ABSTRACT

PURPOSE: To describe an adjustable suture (AS) experimental model that allows for tightening, loosening and retightening of the suture tension in trabeculectomy. METHODS: Standard trabeculectomy was performed in fifteen pig eyeballs. All pig eyes were tested twice: one test with conventional suture in both flap's corners (conventional suture group) and another test with a conventional suture at one corner and an adjustable suture in the other corner (AS group). The order in which each test was performed was defined by randomization. Intraocular pressure was measured at three time points: T1) when the knots were tightened; T2) when the AS was loosened or the conventional knot was removed; and T3) when the AS was retightened in the AS group or five minutes after the knot removal in the conventional suture group. RESULTS: The mean Intraocular pressure was similar between the two groups at time point 1 (p=0.97). However, significant Intraocular pressure differences were found between eyes in the conventional and adjustable suture groups at time points 2 (12.6 ± 4.2 vs 16.3 ± 2.3 cmH2O, respectively, p=0.006) and 3 (12.2 ± 4.0 vs 26.4 ± 1.7cmH2O, respectively; p=0.001). While the conventional technique allowed only Intraocular pressure reduction (following the knot removal; T2 and T3), the AS technique allowed both Intraocular pressure reduction (T2) and elevation (T3) through the management (loosening and retightening) of the suture. CONCLUSION: This experimental model provides an effective noninvasive postoperative mechanism of suture tension adjustment.


OBJETIVO: Descrever uma nova técnica de sutura ajustável para o "flap" da trabeculectomia (TREC), que permite apertar e folgar a sutura no pós-operatório. MÉTODOS: Foram realizadas trabeculectoomia em 15 olhos de porco. Todos os olhos de porco foram testados duas vezes; um teste com sutura convencional nas duas extremidades do "flap"(grupo sutura convencional), outro teste com sutura convencional em uma das extremidades e na outra extremidade a sutura ajustável proposta por esse trabalho (grupo sutura ajustável). A ordem de qual teste seria realizado primeiro em cada olho foi definida por sorteio. A pressão intraocular foi medida de forma direta em três momentos: T1) Todas as suturas apertadas; T2) Após lise de uma sutura convencional ou de afrouxar a sutura ajustável; T3) Após apertar novamente a sutura ajustável ou no caso do teste com as duas suturas convencionais após 5 minutos da lise de uma das suturas. RESULTADOS: No primeiro momento de medida da pressão intraocular (T1) as pressões médias foram similares entre os dois grupos (p=0.97). No entanto, diferenças significativas em relação a pressão intraocular foram encontradas entre os grupos de sutura convencional e ajustável nos tempos 2 (12,6 ± 4,2 vs 16,3 ± 2,3 cmH2O, respectivamente; p=0,006) e 3 (12,2 ± 4,0 vs 26,4 ± 1.7cmH2O, respectivamente; p=0,001). Enquanto a técnica convencional permitiu somente a redução da pressão intraocular após a remoção da sutura (T2 e T3), a técnica de sutura ajustável permitiu tanto a redução (T2) quanto a elevação da pressão intraocular (T3) através do manejo da sutura. CONCLUSÃO: Esse modelo experimental demonstrou a eficácia de uma possível técnica não-invasiva para ajuste da tensão da sutura do "flap"no pós-operatório da trabeculectomia.


Subject(s)
Animals , Suture Techniques , Trabeculectomy/methods , Intraocular Pressure , Models, Animal , Postoperative Period , Reference Values , Reproducibility of Results , Surgical Flaps , Swine , Sclera/surgery , Time Factors
3.
Arq. bras. oftalmol ; 74(5): 326-329, set.-out. 2011. ilus, tab
Article in English | LILACS | ID: lil-608402

ABSTRACT

Purpose: To evaluate the ophthalmic artery hemodynamics in patients with chronic heart failure. Methods: Doppler parameters of ophthalmic artery of 18 patients with chronic heart failure in different stages of the disease were compared with 21 healthy volunteers (control group). These parameters were also correlated with echocardiographic assessments and clinical cardiologic status. Results: Mean diastolic velocity was 5.14 ± 2.4 cm/s in the chronic heart failure group and 7.44 ± 3.5 cm/s in the control group (p=0.007). Mean resistance index of the ophthalmic artery was 0.76 ± 0.08 in the chronic heart failure group and 0.70 ± 0.08 in the control group (p=0.04). Mean systolic velocity of the ophthalmic artery was 22.03 ± 7.7 cm/s in the chronic heart failure group and 25.32 ± 9.2 cm/s in the control group (p=0.24). There was a negative correlation between the resistance index of the ophthalmic artery and systemic blood pressure of patients with chronic heart failure (r= -0.47, p=0.007). Diastolic velocity of the ophthalmic artery correlated positively with systemic blood pressure (r=0.44, p=0.02). Conclusion: Lower diastolic velocity and higher resistance index were observed in the ophthalmic artery of chronic heart failure patients when compared to the control group, which probably reflects the presence of orbital vasoconstriction in response to low cardiac output. Therefore, the influence of these findings on the structure and function of the optic nerve head deserves investigation.


Objetivo: Avaliar o fluxo sanguíneo da artéria oftálmica em pacientes com insuficiência cardíaca crônica. Métodos: Parâmetros da ultrassonografia Doppler em cores da artéria oftálmica de 18 pacientes com insuficiência cardíaca crônica em diferentes estágios da doença foram comparados com 21 voluntários saudáveis (grupo controle). Estes parâmetros foram também correlacionados com avaliação ecocardiográfica e quadro clínico cardiológico. Resultados: A média da velocidade diastólica foi 5,14 ± 2,4 cm/s no grupo insuficiência cardíaca crônica e 7,44 ± 3,5 cm/s no grupo controle (p=0,007). O índice de resistência da artéria oftálmica foi de 0,76 ± 0,08 no grupo insuficiência cardíaca crônica e 0,70 ± 0,08 no grupo controle (p=0,04). A média de velocidade sistólica da artéria oftálmica foi 22,03 ± 7,7 cm/s no grupo insuficiência cardíaca crônica e 25,32 ± 9,2 cm/s no grupo controle (p=0,24). A pressão arterial sistêmica dos pacientes com insuficiência cardíaca crônica correlacionou-se negativamente com o índice de resistência da artéria oftálmica (r= -0,47, p=0,007) e positivamente com a velocidade diastólica da artéria oftálmica (r=0,44, p=0,02). Conclusão: Velocidade diastólica mais baixa e índice de resistência mais alto foram observados na artéria oftálmica de pacientes com insuficiência cardíaca crônica quando comparados ao grupo controle, o que provavelmente reflete a presença de vasoconstrição orbital em resposta ao baixo débito cardíaco. Portanto, a influência desses achados sobre a estrutura e função da cabeça do nervo óptico merece ser investigada.


Subject(s)
Female , Humans , Male , Middle Aged , Heart Failure/physiopathology , Ophthalmic Artery , Blood Flow Velocity/physiology , Case-Control Studies , Chronic Disease , Cross-Sectional Studies , Ophthalmic Artery/physiopathology , Severity of Illness Index , Ultrasonography, Doppler, Color , Vascular Resistance/physiology
4.
Arq. bras. oftalmol ; 73(4): 354-357, July-Aug. 2010. ilus, tab
Article in English | LILACS | ID: lil-560610

ABSTRACT

PURPOSE: To determine factors associated with the test-retest variability of optic nerve head (ONH) topography measurements with confocal scanning laser ophthalmoscopy (CSLO) in newly diagnosed glaucomatous patients. METHODS: Consecutive patients with newly diagnosed primary open-angle glaucoma were prospectively enrolled. Patients presenting with any ocular disease other than glaucoma were excluded. All patients underwent CSLO using the Heidelberg Retina Tomograph III (HRT-III) in one randomly selected eye (three consecutive scans; performed by the same examiner). For each Heidelberg Retina Tomograph III parameter, repeatability was assessed using within subject standard deviation (Sw) and coefficient of variation (CVw), repeatability coefficient (RC) and intraclass correlation coefficient (ICC). Scatter plots and regression lines were constructed to identify which factors influenced test-retest measurement variability. RESULTS: A total of 32 patients were included (mean age, 65.4 ± 13.8 years). Most patients were female (65 percent) and white (50 percent). Among all Heidelberg Retina Tomograph III parameters evaluated, rim area and mean cup depth had the best measurement repeatability. Vertical cup-to-disc ratio (CDR, as determined by optic disc stereophotograph examination) was significantly associated (R²=0.21, p<0.01) with test-retest measurement variability. Eyes with larger CDR showed less variable measurements. Other factors, including age, disc area, central corneal thickness and intraocular pressure were not significant (p>0.14). CONCLUSION: Heidelberg Retina Tomograph III showed good test-retest repeatability for all ONH topographic measurements, mainly for rim area and mean cup depth. Test-retest repeatability seemed to improve with increasing CDR. These findings suggest that HRT-III topographic measurements should be cautiously interpreted when evaluating longitudinally glaucoma patients with early structural damage (small CDR).


OBJETIVO: Determinar os fatores associados à variabilidade (teste-reteste) das medidas topográficas da cabeça do nervo óptico (CNO) utilizando a oftalmoscopia confocal de varredura a laser (CSLO) em pacientes com glaucoma recém-diagnosticados. MÉTODOS: Neste estudo, pacientes com glaucoma primário de ângulo aberto recém-diagnosticados foram prospectivamente incluídos. Aqueles que apresentassem outras doenças oculares (exceto glaucoma) foram excluídos. Todos os pacientes incluídos no estudo foram submetidos à CSLO usando o aparelho Heidelberg Retina Tomograph III (HRT-III) em um olho aleatoriamente selecionado (três exames consecutivos realizados pelo mesmo examinador). Para cada parâmetro do Heidelberg Retina Tomograph III, a repetibilidade foi avaliada através dos seguintes indicadores: desvio padrão (DP) e coeficiente de variação (CV) individual, coeficiente de repetibilidade (CR) e coeficiente de correlação intraclasse (CCI). Diagramas de dispersão e linhas de regressão foram construídos para identificar quais fatores poderiam influenciar a variabilidade das medidas. RESULTADOS: Trinta e dois pacientes foram incluídos no estudo (idade média, 65,4 ± 13,8 anos). A maior parte era composta por mulheres (65 por cento) e pacientes brancos (50 por cento). Dentre os parâmetros de Heidelberg Retina Tomograph III avaliados, a área da rima e a profundidade média da escavação apresentaram os melhores valores de repetibilidade. A relação escavação/disco (E/D) vertical (baseada na análise de estereofotografia do disco óptico), foi significativamente associada (R²=0.21, p<0.01) com a variabilidade teste-reteste. Pacientes com relação E/D maiores apresentaram medidas menos variáveis. Outros fatores como idade, área do disco, espessura corneana central e pressão intraocular não foram significativas (p>0,14). CONCLUSÃO: O Heidelberg Retina Tomograph III mostrou boa repetibilidade (teste-reteste) para todos os parâmetros topográficos da CNO avaliados, principalmente em relação à área da rima e à profundidade média da escavação. A repetibilidade teste-reteste apresentou melhores resultados com o aumento da relação E/D. Esses achados sugerem que as medidas topográficas do Heidelberg Retina Tomograph III devem ser interpretadas com cautela quando avaliarmos longitudinalmente pacientes glaucomatosos com dano estrutural inicial (relação E/D menor).


Subject(s)
Aged , Female , Humans , Male , Middle Aged , Glaucoma, Open-Angle/diagnosis , Ophthalmoscopy/methods , Optic Disk/anatomy & histology , Tomography/methods , Age Factors , Cross-Sectional Studies , Microscopy, Confocal , Ophthalmoscopes/standards , Optic Nerve Diseases/diagnosis , Reproducibility of Results , Sex Factors
5.
Arq. bras. oftalmol ; 72(6): 832-835, Nov.-Dec. 2009. ilus
Article in English | LILACS | ID: lil-536782

ABSTRACT

The optical coherence tomography (OCT) and indocyanine green angiography (ICGA) findings of a 58-year-old male with acute syphilitic posterior placoid chorioretinitis are reported herein. Best-corrected visual acuity was 20/150 in the right eye (OD) and 20/30 in the left eye (OS) at presentation. On funduscopy, there was a central subretinal placoid yellowish lesion in OD. VDRL and serum FTA-ABS were positive. OCT showed increased reflectance and thickening of the subfoveal RPE-choriocapillaris complex corresponding to the lesion in OD. ICGA revealed a hypofluorescent spot corresponding to the lesion in OD and confluent small dots extending to periphery, without any correspondence in fundus examination. The same dots were also seen in OS, even though no lesions could be observed clinically. Intravenous ceftriaxone 2 g daily was given for 10 days. One month after the first visit, visual acuity improved to 20/30 and marked improvement of the lesion was seen. OCT was normal in both eyes at the final visit.


Relatamos aqui os achados da tomografia de coerência óptica (OCT) e angiografia com indocianina verde (ICGA) de um paciente masculino de 58 anos com a coroidopatia placóide posterior aguda sifilítica. A acuidade visual corrigida na apresentação foi de 20/150 no olho direito (OD) e 20/30 no olho esquerdo (OE). A fundoscopia evidenciou lesão sub-retiniana placóide amarelada central no OD. As sorologias VDRL e FTA-ABS foram positivas. OCT evidenciou aumento de refletividade subfoveal e espessamento do complexo EPR-coriocapilar correspondente à lesão do OD. ICGA revelou hipofluorescência local correspondente à lesão do OD e pequenos pontos confluentes que se estendiam para a periferia, sem qualquer correspondência na fundoscopia. O mesmo também foi visto no OE, embora nenhuma lesão pode ser observada clinicamente. Ceftriaxona 2 g intravenosa diária foi administrada durante 10 dias. Um mês após a primeira visita, a acuidade visual do OD foi 20/30 e melhora acentuada da lesão foi observada. Na última visita, o OCT foi normal em ambos os olhos.


Subject(s)
Humans , Male , Middle Aged , Chorioretinitis/pathology , Syphilis/complications , Coloring Agents , Fluorescein Angiography/methods , Indocyanine Green , Tomography, Optical Coherence/methods
SELECTION OF CITATIONS