Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Acta Anatomica Sinica ; (6): 244-248, 2023.
Article in Chinese | WPRIM | ID: wpr-1015231

ABSTRACT

Objective To design and validate a novel surgical guide for retrieval of foreign body in jaw. Methods Firstly, a surgical guide based on cone beam computed tomography and trephine technique was designed to remove broken dental instrument fragments. Its feasibility and accuracy were assessed by removing broken dental instrument in goat mandible, and then it was successfully applied in clinical cases. The linear and angular discrepancies between actual and planned columnar bone with imaginary fragment was analyzed. The euclidean distance was measured at the hex and apex of the columnar bone and the angle of axis deviation was also calculated. We obtained seven parameters (cdh, cda, hdh, hda, vdh, vda, and ad) to describe deviations. Results Mean central deviation at the hex and apex was (0.51 ± 0.14) mm and (0.62 ± 0.19) mm, respectively. Accompanying mean values were as follow: horizontal deviation at the hex was (0.48 ± 0.16) mm, horizontal deviation at the apex was (0.52 ± 0.22) mm, vertical deviation at the hex was (0.17 ± 0.09) mm, vertical deviation at the apex was (0.29 ± 0.13) mm, and angular deviation of (5.38 ± 3.43) degrees. In a clinical case, the guide successfully located and removed the fracture file. Conclusion This study reveals that this kind novel surgical guide could aid to locate and remove the foreign body in jaw.

2.
West China Journal of Stomatology ; (6): 532-538, 2018.
Article in Chinese | WPRIM | ID: wpr-772463

ABSTRACT

OBJECTIVE@#This work aims to analyze the mechanical properties and biocompatibility of porous titanium (Ti) implants fabricated by selective laser sintering (SLS) and investigate the promotion of osseointegration by porous titanium implant combined with chitosan (CS)/hydroxyapatite(HA) composite coating.@*METHODS@#Ti6Al4V specimens were prepared, and CS/HA composite coating was fabricated on the surface of a portion of the specimens. The mechanical properties of the samples were observed by scanning electron microscope. MC3T3-E1 cells were cultured in vitro, and their biological properties in vitro were analyzed using live and dead viability cell staining method, methyl thiazolyl tetrazolium (MTT) staining, and alkaline phosphatase (ALP) level detection. The thread implant specimens were implanted in the femoral condyle of rabbits, and biological performance was evaluated in vivo.@*RESULTS@#Quasi-elastic gradient of porous specimens decreased with increasing porosity, and the quasi-elastic gradient were close to cortical and cancellous bone when the porosities were 30% and 70%. The specimens showed good biocompatibility. Combined with CS/HA coating, the implants promoted the proliferation and differentiation of MC3T3-E1 cells and facilitated the entry of bone tissue into pores and good osteogenesis.@*CONCLUSIONS@#The porous titanium implant exhibited favorable mechanical properties and biocompatibility. Combined with CS/HA coating, the implant exhibited bone inducibility, which leads to stable osteogenesis.


Subject(s)
Animals , Rabbits , Durapatite , Lasers , Materials Testing , Microscopy, Electron, Scanning , Osseointegration , Porosity , Prostheses and Implants , Surface Properties , Titanium
SELECTION OF CITATIONS
SEARCH DETAIL