Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add filters








Language
Year range
1.
Univ. odontol ; 27(59): 15-22, ene.-dec. 2008. ilus
Article in Spanish | LILACS | ID: lil-587050

ABSTRACT

ANTECEDENTES: Se ha establecido que las lámparas LED no son viables para el fotopolimerizado de resinas que presentan fotoiniciadores diferentes a canforoquinona, debido a las diferencias entre el espectro de emisión de las lámparas y el espectro de absorción del fotoiniciador. OBJETIVO: Determinar la profundidad de curado de resinas con fotoiniciadores diferentes utilizando lámparas LED. METODOS: Se realizó un diseño experimental in vitro; 120 muestras de resina de 2x8mm y 4x8mm se fabricaron y se dividieron en 12 grupos de 10 muestras. Se utilizó la resina Point 4 XL1 (Kerr) con fenilpropanodiona y Z100 A3 (3M ESPE) con canforoquinona. Las lámparas utilizadas fueron Elipar Freelight 2 (3M ESPE), Bluephase (IVOCLAR) y Elipar 2500 (3M ESPE). Se determinó la profundidad de curado con el durímetro de Vickers. El análisis estadístico se realizó mediante la prueba de ANOVA factorial de tres vías y la prueba H de Kruskall Wallis. RESULTADOS: No se encontraron diferencias significativas en la profundidad de curado obtenida con las tres lámparas (p?0.05). En muestras de 2x8mm con fenilpropanodiona se obtuvo una profundidad de curado promedio de 0.3986 y 0.4027 para la parte superior e inferior respectivamente y 0.3917 y 0.3999 para muestras de 4x8mm. En muestras de 2x8mm con canforoquinona el promedio fue de 0.2801 y 0.2815 para la parte superior e inferior respectivamente y 0.3261 y 0.3264 para muestras de 4x8mm. CONCLUSIONES: No se encontraron diferencias significativas en la profundidad de curado que se obtuvieron con las tres lámparas.


BACKGROUND: It has been stablished that LED lamps are not suitable to cure resins that present photoinitiators other than camphorquinone because of the differences between the specral emission of the lamp and the absorption spectrum of the initiator. OBJECTIVE: Determine the depth of cure of resins with different photoinitiators using LED lamps. METHODS: An experimental in vitro study was carried out. 120 samples of composite resin of 2x8mm and 4x8mm were fabricated and divided into 12 groups of 10 samples each. The composites were Point 4 XL1 (KERR) with phenylpropanedione and Z100 A3 (3M ESPE) with camphorquinone. The curing units used were Elipar Freelight 2 (3M ESPE), Bluephase (IVOCLAR)and Elipar 2500 (3M ESPE). The depth of cure was determined with a Vickers indenter. Statistical analysis was carried out using a three-way ANOVA and the Kruskall-Wallis H test RESULTS: There were no significant differences in the depth of cure obtained with the three curing units (p>0.05). The mean depth of cure in samples of 2x8mm with phenylpropanedione was 0.3986 y 0.4027 respectively for the upper and lower parts of the samples, and 0.3917 y 0.3999 for samples of 4x8mm. For samples of 2x8mm with camphorquinone the mean values were 0.2801 and 0.2815 for the upper and lower parts respectively and 0.3261 y 0.3264 for samples of 4x8mm. CONCLUSIONS: No significant differences were found in the depth of cure obtained with the three curing units.


Subject(s)
Laboratories, Dental , Dental Materials , Resins, Synthetic
SELECTION OF CITATIONS
SEARCH DETAIL