Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 11 de 11
Filter
1.
Intestinal Research ; : 126-136, 2023.
Article in English | WPRIM | ID: wpr-967006

ABSTRACT

Background/Aims@#The usefulness of ultrasonography (US) in diseases of the gastrointestinal tract has been reported recently. This prospective study aimed to determine the features of US findings in immune-mediated colitis (IMC), an adverse event induced by immune checkpoint inhibitor, and examine the correlation between US findings, colonoscopy (CS) findings, and severity of colitis. @*Methods@#We studied patients examined using CS and US upon suspicion of IMC in Hokkaido University Hospital between April 2018 and February 2021. Endoscopic findings of IMC were assessed using the Ulcerative Colitis Endoscopic Index of Severity (UCEIS). The severity of US findings in IMC was evaluated using US grade, which is the ultrasonographic grading scale in ulcerative colitis. Bowel wall thickness and the intensity of the color Doppler signal were also analyzed. Severity of colitis was evaluated using Common Terminology Criteria for Adverse Events (CTCAE) grade version 5. @*Results@#Fourteen patients with IMC were enrolled. The US findings were bowel wall thickening, loss of stratification, ulceration and increased blood flow signal. The US grade was moderately correlated with the UCEIS (r=0.687, p=0.009) and CTCAE grade (r=0.628, p=0.035). Bowel wall thickness and UCEIS (r=0.628, p=0.020), as well as color Doppler signal grade and CTCAE grade (r=0.724, p=0.008), were significantly correlated. @*Conclusions@#US findings in IMC were mainly similar to those of ulcerative colitis, but there were some findings that were characteristic only of IMC. Significant correlation was found between US findings, CS findings, and severity of colitis. Hence, US could be useful for the evaluation of IMC.

2.
Intestinal Research ; : 78-89, 2022.
Article in English | WPRIM | ID: wpr-914742

ABSTRACT

Background/Aims@#Inflammatory bowel disease (IBD) patients frequently have zinc deficiency. IBD patients with zinc deficiency have higher risks of IBD-related hospitalization, complications, and requiring surgery. This study aimed to examine the effectiveness of zinc acetate hydrate (ZAH; Nobelzin) in IBD patients with zinc deficiency. @*Methods@#IBD patients with zinc deficiency who received ZAH from March 2017 to April 2020 were registered in this two-center, retrospective, observational study. Changes in serum zinc levels and disease activity (Crohn’s Disease Activity Index [CDAI]) before and after ZAH administration were analyzed. @*Results@#Fifty-one patients with Crohn’s disease (CD, n = 40) or ulcerative colitis (UC, n = 11) were registered. Median serum zinc level and median CDAI scores significantly improved (55.5–91.0 μg/dL, P< 0.001; 171.5–129, P< 0.001, respectively) in CD patients 4 weeks after starting ZAH administration. Similarly, median serum zinc levels and CDAI scores significantly improved (57.0–81.0 μg/dL, P< 0.001; 177–148, P= 0.012, respectively) 20 weeks after starting ZAH administration. Similar investigations were conducted in groups where no treatment change, other than ZAH administration, was implemented; significant improvements were observed in both serum zinc level and CDAI scores. Median serum zinc levels in UC patients 4 weeks after starting ZAH administration significantly improved from 63.0 to 94.0 μg/dL (P= 0.002), but no significant changes in disease activity were observed. One patient experienced side effects of abdominal discomfort and nausea. @*Conclusions@#ZAH administration is effective in improving zinc deficiency and may contribute to improving disease activity in IBD.

3.
Intestinal Research ; : 274-277, 2022.
Article in English | WPRIM | ID: wpr-925126

ABSTRACT

X-linked inhibitor of apoptosis (XIAP) deficiency is a rare primary immunodeficiency and gastrointestinal (GI) lesions in XIAP deficiency are similar to Crohn’s disease. For patients with Crohn’s disease, endoscopic balloon dilation (EBD) is known to be a standard procedure for intestinal strictures including upper GI tract. However, there are no articles which mention the efficacy of EBDs for the strictures in upper GI tract in patients with XIAP deficiency. Herein, we describe an 18-year-old male with XIAP deficiency in whom EBDs for the rectum, ileocecal valve (ICV), and duodenum were performed. Before hematopoietic stem cell transplantation (HSCT), GI endoscopy revealed strictures of the rectum, ICV and duodenum with active ulcers. Although these ulcers healed after HSCT, the strictures progressed. Therefore, we performed EBDs for the strictures of the rectum, ICV, and duodenum. In contrast studies, we did not find any other strictures in the small intestine. Throughout the patient’s clinical course, no complications of EBD occurred. He started eating after EBDs, but abdominal symptoms did not relapse without any dietary restrictions. Our case suggests that EBD could be an effective and safe procedure for intestinal strictures including upper GI tract after HSCT in patients with XIAP deficiency.

4.
Gastrointestinal Intervention ; : 34-35, 2018.
Article in English | WPRIM | ID: wpr-739759

ABSTRACT

A 69-year-old woman with jaundice was referred to our hospital. After a final diagnosis of pancreatic cancer with liver metastasis, we performed transpapillary biliary drainage with a covered self-expandable metal stent (SEMS). Three months later, we also placed an uncovered duodenal stent for duodenal stricture in a side-to-end fashion. Another month later, for biliary SEMS obstruction, we attempted a transpapillary approach. A duodenoscope was advanced and a guidewire was passed through the mesh of the duodenal stent into the bile duct with a flexible tip catheter, but the catheter was not. Thus, we exchanged the duodenoscope for a forward-viewing two-channel endoscope and used the left working channel with a flexible tip catheter. By adjusting the axis, we finally succeeded biliary cannulation and accomplished balloon cleaning for recanalization of the SEMS. This is the first case with successful biliary cannulation by combined use of a two-channel endoscope and a flexible tip catheter.


Subject(s)
Aged , Female , Humans , Bile Ducts , Catheterization , Catheters , Cholestasis , Constriction, Pathologic , Diagnosis , Drainage , Duodenoscopes , Endoscopes , Jaundice , Liver , Neoplasm Metastasis , Pancreatic Neoplasms , Stents
5.
Gut and Liver ; : 353-359, 2018.
Article in English | WPRIM | ID: wpr-714661

ABSTRACT

BACKGROUND/AIMS: Although the risk of bleeding after endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) is low, the safety of EUS-FNA in patients prescribed antithrom-botic agents is unclear. Therefore, this study evaluated the incidence of bleeding after EUS-FNA in those patients. METHODS: Between September 2012 and September 2015, patients who were prescribed antithrombotic agents underwent EUS-FNA at 13 institutions in Japan were prospectively enrolled in the study. The antithrombotic agents were managed according to the guidelines of the Japanese Gastrointestinal Endoscopy Society. The rate of bleeding events, thromboembolic events and other complications within 2 weeks after EUS-FNA were analyzed. RESULTS: Of the 2,629 patients who underwent EUS-FNA during the study period, 85 (62 males; median age, 74 years) patients were included in this stduy. Two patients (2.4%; 95% confidence interval [CI], 0.6% to 8.3%) experienced bleeding events. One patient required surgical intervention for hemothorax 5 hours after EUS-FNA, and the other experienced melena 8 days after EUS-FNA and required red blood cell transfusions. No thromboembolic events occurred (0%; 95% CI, 0.0% to 4.4%). Three patients (3.5%; 95% CI, 1.2% to 10.0%) experienced peri-puncture abscess formation. CONCLUSIONS: The rate of bleeding after EUS-FNA in patients prescribed antithrombotic agents might be considerable.


Subject(s)
Humans , Male , Abscess , Asian People , Endoscopic Ultrasound-Guided Fine Needle Aspiration , Endoscopy, Gastrointestinal , Erythrocyte Transfusion , Fibrinolytic Agents , Hemorrhage , Hemothorax , Incidence , Japan , Melena , Prospective Studies
7.
Journal of Gastric Cancer ; : 177-181, 2016.
Article in English | WPRIM | ID: wpr-216433

ABSTRACT

PURPOSE: The International Organization for Standardization-5fluorouracil (FU) 10 trial found that bolus 5-FU and l-leucovorin was not inferior to S-1 in the treatment of gastric cancer (GC). Continuous 5-FU and the rapid injection of 5-FU have different anti-cancer effects. Thus, bolus 5-FU and l-leucovorin treatment might be useful for oral FU-resistant GC. MATERIALS AND METHODS: We retrospectively analyzed the medical records of all patients with S-1 or capecitabine-resistant, unresectable, or recurrent GC treated with bolus 5-FU and l-leucovorin between January 2010 and December 2015 at Hokkaido University Hospital. The bolus 5-FU and l-leucovorin regimen consisted of intravenous l-leucovorin (250 mg/m²/2 h) and bolus 5-FU (600 mg/m²) administered once weekly followed by a 2-week rest period; each cycle was repeated every 8 weeks. RESULTS: A total of 14 patients were identified. The disease control rate was 35.7%. The median progression-free survival was 1.6 months (95% confidence interval [CI], 1.3~2.0 months), and the median overall survival was 6.3 months (95% CI, 4.7~7.9 months). No patient died from treatment-related causes. The most common severe adverse event associated with bolus 5-FU and l-leucovorin was neutropenia, which occurred in 21.4% of patients. CONCLUSIONS: Bolus 5-FU and l-leucovorin treatment might be useful for oral FU-resistant GC. We are planning a multi-center prospective phase II trial to evaluate the efficacy and safety of bolus 5-FU and l-leucovorin treatment for pre-treated unresectable or recurrent GC to confirm the results of this limited, retrospective study.


Subject(s)
Humans , Disease-Free Survival , Drug Therapy , Fluorouracil , Leucovorin , Medical Records , Neutropenia , Prospective Studies , Retrospective Studies , Stomach Neoplasms
8.
Chinese Journal of Traumatology ; (6): 360-362, 2015.
Article in English | WPRIM | ID: wpr-235800

ABSTRACT

Most mediastinal abscesses result from infections after thoracotomy, esophageal perforation or pene- trating chest trauma. This disease is rarely caused by closed blunt chest trauma. All previously reported such cases after closed blunt chest trauma presented with hematoma and sternal osteomyelitis resulting from sternal fracture. Here we report a 15-year-old sumo wrestler who presented with an anterior mediastinal abscess without any mediastinal fracture. The mediastinal abscess resulted from the hematogenous spread of Staphylococcus aureus to a hematoma that might have been caused by a closed blunt chest trauma incurred during sumo wrestling exercises.


Subject(s)
Adolescent , Humans , Male , Abscess , Diagnosis , Microbiology , Therapeutics , Anti-Bacterial Agents , Therapeutic Uses , Combined Modality Therapy , Debridement , Diagnosis, Differential , Drainage , Magnetic Resonance Imaging , Mediastinal Diseases , Diagnosis , Microbiology , Therapeutics , Staphylococcal Infections , Diagnosis , Microbiology , Therapeutics , Thoracic Injuries , Diagnosis , Microbiology , Therapeutics , Tomography, X-Ray Computed , Wounds, Nonpenetrating , Diagnosis , Microbiology , Therapeutics , Wrestling , Wounds and Injuries
9.
Gut and Liver ; : 251-252, 2015.
Article in English | WPRIM | ID: wpr-190723

ABSTRACT

A 72-year-old man with jaundice by ampullary adenocarcinoma was treated at our hospital. For biliary decompression, a transpapillary, fully covered, self-expandable metal stent (FCSEMS) was deployed. Four days later, the patient developed acute cholangitis. Endoscopic carbon dioxide cholangiography revealed kinking of the common bile duct above the proximal end of the FCSEMS. A 7-F double-pigtail plastic stent was therefore placed through the FCSEMS to correct the kink, straightening the common bile duct (CBD) and improving cholangitis. This is the first report of a unique use of a double-pigtail plastic stent to correct CBD kinking. The placement of a double-pigtail plastic stent can correct CBD kinking, without requiring replacement or addition of a FCSEMS, and can lead to cost savings.


Subject(s)
Aged , Humans , Male , Common Bile Duct/injuries , Constriction, Pathologic/surgery , Decompression, Surgical/instrumentation , Self Expandable Metallic Stents/adverse effects , Stents , Torsion Abnormality/surgery
10.
Gut and Liver ; : 329-332, 2014.
Article in English | WPRIM | ID: wpr-163232

ABSTRACT

Endoscopic ultrasound (EUS) and endoscopic retrograde cholangiopancreatography (ERCP) are essential for diagnosing and treating pancreatobiliary diseases. Single-session EUS and ERCP are considered to be essential in reducing the duration of hospital stays; however, complications are a primary concern. The aim of this study was to evaluate the safety and efficacy of single-session EUS and ERCP. Sixty-eight patients underwent single-session EUS and ERCP at a tertiary referral center between June 2008 and December 2012. We retrospectively reviewed patient data from a prospectively maintained EUS-ERCP database and evaluated the procedural characteristics and complications. Thirty-eight patients (56%) underwent diagnostic EUS, and 30 patients (44%) underwent EUS fine-needle aspiration, which had an overall accuracy of 100%. Sixty patients (89%) underwent therapeutic ERCP, whereas the remaining eight procedures were diagnostic. Thirteen patients underwent biliary stone extraction, and 48 underwent biliary drainage. The median total procedural time was 75 minutes. Complications were observed in seven patients (10%). Six complications were post-ERCP pancreatitis, which were resolved using conservative management. One patient developed Mallory-Weiss syndrome, which required endoscopic hemostasis. No sedation-related cardiopulmonary complications were observed. Single-session EUS and ERCP provided accurate diagnosis and effective management with a minimal complication rate.


Subject(s)
Aged , Female , Humans , Male , Middle Aged , Biliary Tract Diseases/diagnosis , Cholangiopancreatography, Endoscopic Retrograde/methods , Endosonography/methods , Pancreatic Diseases/diagnosis , Patient Safety , Prospective Studies , Retrospective Studies
11.
Gut and Liver ; : 341-355, 2014.
Article in English | WPRIM | ID: wpr-175287

ABSTRACT

Endoscopic drainage for pancreatic and peripancreatic fluid collections (PFCs) has been increasingly used as a minimally invasive alternative to surgical or percutaneous drainage. Recently, endoscopic ultrasound-guided transluminal drainage (EUS-TD) has become the standard of care and a safe procedure for nonsurgical PFC treatment. EUS-TD ensures a safe puncture, avoiding intervening blood vessels. Single or multiple plastic stents (combined with a nasocystic catheter) were used for the treatment of PFCs for EUS-TD. More recently, the use of covered self-expandable metallic stents (CSEMSs) has provided a safer and more efficient approach route for internal drainage. We focused our review on the best approach and stent to use in endoscopic drainage for PFCs. We reviewed studies of EUS-TD for PFCs based on the original Atlanta Classification, including case reports, case series, and previous review articles. Data on clinical outcomes and adverse events were collected retrospectively. A total of 93 patients underwent EUS-TD of pancreatic pseudocysts using CSEMSs. The treatment success and adverse event rates were 94.6% and 21.1%, respectively. The majority of complications were of mild severity and resolved with conservative therapy. A total of 56 patients underwent EUS-TD using CSEMSs for pancreatic abscesses or infected walled-off necroses. The treatment success and adverse event rates were 87.8% and 9.5%, respectively. EUS-TD can be performed safely and efficiently for PFC treatment. Larger diameter CSEMSs without additional fistula tract dilation for the passage of a standard scope are needed to access and drain for PFCs with solid debris.


Subject(s)
Humans , Abdominal Abscess/surgery , Drainage/methods , Endosonography/methods , Necrosis/surgery , Pancreas/pathology , Pancreatic Diseases/surgery , Pancreatic Pseudocyst/surgery , Stents , Surgery, Computer-Assisted/methods , Ultrasonography, Interventional/methods
SELECTION OF CITATIONS
SEARCH DETAIL